979 resultados para Stern-Volmer
Resumo:
The rehabilitation of a patient with advanced tooth wear by means of Procera ZrO2 ceramic crowns is described. A healthy, 60 year old patient complained about front teeth esthetics and impaired function due to reduced tooth height. He was aware of bruxism and wished full mouth rehabilitation. The clinical examination showed that tooth wear was generalized, but most teeth could be maintained in both jaws. A staged procedure was planned, starting with a splint therapy and a provisional fixed prosthesis to reestablish correct vertical dimension of occlusion (VDO) and stable occlusal contacts. The new ZrO2 material with the Procera technique was chosen to restore all teeth in both jaws, except the mandible front teeth. In the second treatment phase, crown lengthening of the maxillary front teeth was performed and one implant placed to replace a maxillary premolar. After final tooth preparation, impression taking and bite registration the ZrO2 crown-copings were scanned, processed and completed by veneering. A flat occlusal scheme with stable front teeth guidance was established. The advantage of the presented treatment is the esthetic result in combination with a material of high mechanical and biological quality.
Resumo:
There is increasing evidence that air pollution particularly affects infants and small preschool children. However, detecting air pollution effects on lung function in small children is technically difficult and requires non-invasive methods that can assess lung function and inflammatory markers in larger cohorts. This review discusses the principles, usefulness and shortcomings of various lung function techniques used to detect pollution effects in small children. The majority of these techniques have been used to detect effects of the dominant indoor pollutant, tobacco exposure. However there is increasing evidence that non-invasive lung function techniques can also detect the effects of outdoor air pollution.
Resumo:
Copper (Cu) and its alloys are used extensively in domestic and industrial applications. Cu is also an essential element in mammalian nutrition. Since both copper deficiency and copper excess produce adverse health effects, the dose-response curve is U-shaped, although the precise form has not yet been well characterized. Many animal and human studies were conducted on copper to provide a rich database from which data suitable for modeling the dose-response relationship for copper may be extracted. Possible dose-response modeling strategies are considered in this review, including those based on the benchmark dose and categorical regression. The usefulness of biologically based dose-response modeling techniques in understanding copper toxicity was difficult to assess at this time since the mechanisms underlying copper-induced toxicity have yet to be fully elucidated. A dose-response modeling strategy for copper toxicity was proposed associated with both deficiency and excess. This modeling strategy was applied to multiple studies of copper-induced toxicity, standardized with respect to severity of adverse health outcomes and selected on the basis of criteria reflecting the quality and relevance of individual studies. The use of a comprehensive database on copper-induced toxicity is essential for dose-response modeling since there is insufficient information in any single study to adequately characterize copper dose-response relationships. The dose-response modeling strategy envisioned here is designed to determine whether the existing toxicity data for copper excess or deficiency may be effectively utilized in defining the limits of the homeostatic range in humans and other species. By considering alternative techniques for determining a point of departure and low-dose extrapolation (including categorical regression, the benchmark dose, and identification of observed no-effect levels) this strategy will identify which techniques are most suitable for this purpose. This analysis also serves to identify areas in which additional data are needed to better define the characteristics of dose-response relationships for copper-induced toxicity in relation to excess or deficiency.
Platformswitching - Methodik zum Erhalt des periimplantären crestalen Knochens: Mythos oder Realität
Resumo:
This case series reports on the use of nonsilica-based high-strength full ceramics for different prosthetic indications. Fifty-two consecutive patients received tooth- or implant-supported zirconia reconstructions during a 2-year period. The observation period for reexamination was 12 to 30 months. The most frequent indications were single crowns and short-span fixed partial dentures. A few implant superstructures were screw-retained, whereas all remaining restorations were cemented on natural teeth or zirconia implant abutments. Clinical examination included biologic (probing depths, bleeding on probing) and esthetic (Papilla Index) parameters, as well as technical complications. No implant was lost or caused any problems, but two teeth were lost after horizontal fracture. Overall, the periodontal parameters were favorable. Fractures of frameworks or implant abutments were not observed. Abutment-screw loosening occurred once for one premolar single crown. Furthermore, five implant crowns in the posterior region exhibited chipping of the porcelain veneering material. With regard to esthetics, no reconstructions were considered unacceptable, but three crowns were remade shortly after delivery. In this short-term study, it was observed that biologic, esthetic, and mechanical properties of zirconia were favorable, and the material could be used in various prosthetic indications on teeth or implants.
Resumo:
Different types of titanium-alloys instead of CoCr-alloys have been tested as material for the framework of removable partial dentures (RPD). Adequate casting and processing techniques have been developed which enable to fabricate frameworks of complex designs and the problem limits porosity. This opened new possibilities for the use of titanium-alloys with improved properties (E-module). The aim of this study was to summarise the use of titanium in removable prosthodontics and to evaluate prospectively the use of the Ti6A17Nb-alloy for RPDs in a small group of patients. Two identically designed RPDs from CoCr-alloy (remanium GM 800+) and Ti6A17Nb-alloy (girotan L) were produced for ten patients. They had to wear each RPD during six months, first the CoCr-RPD and then the Ti6A17Nb-RPD. A questionnaire (visual analogue scale = VAS) was completed by the patients after one, three and six months of function for each RPD. Prosthetic complications and service needed were recorded. After the end of the entire observation period of twelve months, the patients remained with the Ti6A17Nb-RPD and answered the questionnaire after another six months. All parameters regarding the design of the RPDs were positively estimated by the dentist. Minimal, not significant differences were noted by the patients concerning comfort, stability and retention (VAS). Clinically, no differences in technical aspects or regarding biological complications were observed after six-months periods. The Ti6A17Nb-alloy (girotan L) for the framework of RPDs was judged by patients and professionals to be equivalent to RPDs made from CoCr-alloy. No differences in material aspects could objectively be observed. The Ti6A17Nb-alloy can be beneficial for patients with allergies or incompatibility with one or several components of the CoCr-alloy.
Resumo:
The present paper deals with the double crown technique in removable prosthodontics. New ceramic materials like zirconia are increasingly used in combination with CAD/CAM technologies for framework fabrication of fixed prosthesis, tooth- or implant-supported. However, zirconia is also a newly accepted material in removable prosthodontics. It replaces gold alloys for the fabrication of primary telescopic crowns. The Galvanoforming technology is preferably used to fabricate the secondary crowns. The combination of both techniques and materials results in a prosthetic reconstruction of high quality, optimum fit and good biocompatibility.
Resumo:
BACKGROUND: There is evidence for the superiority of two-implant overdentures over complete dentures in the mandible. Various anchorage devices were used to provide stability to overdentures. The aim of the present study was to compare two designs of a rigid bar connecting two mandibular implants. MATERIALS AND METHODS: Completely edentulous patients received a new denture in the maxilla and an implant-supported overdenture in the mandible. They were randomly allocated to two groups (A or B) with regard to the bar design. A standard U-shaped bar (Dolder bar) was used connecting the two implants in a straight line. For comparison, precision attachments were soldered distal to the bar copings. Group A started the study with the standard bar (S-bar), while group B started with the attachment-bar (A-bar). After 3 months, they had to answer a questionnaire (visual analogue scale [VAS]); then the bar design was changed in both groups. After a period of another 3 months, the patients had to answer the same questions; then they had the choice to keep their preferred bar. Now the study period was extended to another year of observation, and the patients answered again the same questionnaire. In vivo force measurements were carried out with both bar types at the end of the test periods. The prosthetic maintenance service carried out during the 6-month period was recorded for both bar types in both groups. Statistical analysis as performed with the SPSS statistical package (SPSS Inc., Chicago, IL, USA). RESULTS: Satisfaction was high in both groups. Group B, who had entered the study with the attachment bar, gave slightly better ratings to this type for four items, while in group A, no differences were found. At the end of the 6-month comparison period, all but one patient wished to continue to wear the attachment bar. Prosthetic service was equal in groups A and B, but the total number of interventions is significantly higher in the attachment bar. Force patterns of maximum biting were similar in both bar designs, but exhibited significantly higher axial forces in the attachment bar. CONCLUSIONS: Both bar designs provide good retention and functional comfort. High stability appears to be an important factor for the patients' satisfaction and oral comfort. Rigid retention results in a higher force impact and appears to evoke the need for the retightening of occlusal screws, resulting in more maintenance service.