983 resultados para Software clones Detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Active infection by T. gondii was evaluated by immunoassay for soluble SAG-1 (p30), the major surface antigen from T. gondii, specific antibodies and immune complexes in human cerebrospinal fluid (CSF) samples. A total of 263 samples of CSF were collected from hospitalized patients presenting neurological disorders and analyzed for antibodies to HIV. Patients were divided into two groups: HIV positive (n = 96) or HIV negative (n =167). The results of the assays showed that 45% of all samples were positive for soluble SAG-1. Toxoplasma Ag/Ab immune complexes were detected in 19% of the CSF samples and 62% were positive for T. gondii- specific IgG. A combination of these assays in the presence of clinical findings consistent with active Toxoplasma infection may predict the presence of toxoplasmic encephalitis. Moreover, detection of soluble SAG-1 in the CSF of these individuals appears consistent with active infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neurocysticercosis (NC), the presence of Taenia solium metacestodes in tissues, is the most frequent and severe parasitic infection of the central nervous system. We investigated the presence of total IgE by an automated chemiluminescence assay in 53 paired cerebrospinal fluid (CSF) and serum samples from patients with NC (P) and in 40 CSF samples from individuals with other neurological disorders as the control group (C). Total IgE concentration ranged from 1.2 to 6.6 IU/ml (mean = 1.4 IU/ml, standard deviation-sd = 1.1 IU/ml) in 28.3% of CSF samples from the P group, a value significantly higher than for the C group (£1.0 IU/ml). The serum samples from the P group showed concentrations ranging from 1.0 to 2330.0 IU/ml (mean = 224.1 IU/ml, sd = 452.1 IU/ml), which were higher than the normal value cited by the manufacturer (<100.0 IU/ml) in 32.1% of the samples. A significant difference was observed in CSF samples from the P and C groups (p = 0.005) and in serum samples from the P group compared to the normal value (p = 0.005), with sera showing more frequent abnormal results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crescente expansão urbana e o incremento das exigências ambientais e financeiras promovem a implementação de abordagens sustentáveis para a gestão das infraestruturas sanitárias. Assim, o recurso a instrumentos de monitorização e à modelação matemática surge como o caminho para a racionalização do investimento e a otimização dos sistemas existentes. Neste contexto, a modelação dinâmica de sistemas de drenagem urbana assume relevância para o controlo e redução dos caudais em excesso e das descargas de poluentes nos meios recetores, resultantes de um incremento significativo de afluências pluviais indevidas, de problemas de sub-dimensionamento ou falta de operação e manutenção. O objetivo da presente dissertação consiste na modelação, calibração e diagnóstico do sistema intercetor de Lordelo utilizando o software Storm Water Management Model, através dos dados recolhidos a partir do projeto de Reabilitação dos intercetores de Lordelo, elaborado pela Noraqua. A modelação considera a avaliação das afluências de tempo seco e as afluências pluviais pelo software Sanitary Sewer Overflow Analysis and Planning Toolbox. Com efeito, a simulação dinâmica, permitiu um conhecimento mais detalhado do sistema, avaliando a capacidade hidráulica e localizando os pontos propícios a inundações. Assim, foi possível testar soluções de beneficiação do sistema, englobando a problemática das afluências pluviais indevidas calibradas. Apesar das dificuldades sentidas face à qualidade dos dados existentes, verificou-se que o SSOAP e o SWMM são ferramentas úteis na deteção, diagnóstico e redução dos caudais em excesso e que o procedimento utilizado pode ser aplicado a sistemas semelhantes, como forma de definir a melhor solução técnica e económica ao nível do planeamento, operação e reabilitação do sistema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crescente utilização de dispositivos móveis com diferentes finalidades é uma realidade. Com estes dispositivos, o utilizador tem a necessidade de aceder e usar dados em tempo real provenientes de diversas fontes. Uma tendência acentuada passa pela incorporação destes dispositivos móveis no vestuário, designados por dispositivos wearable. Segundo a empresa IMS Research, o mercado deste tipo de dispositivos irá aumentar de 14 milhões de unidades registadas no presente ano (2013), para cerca de 171 milhões em 2016, sendo esta previsão conservadora, segundo o analista da IMS Research, Theo Ahadome [15]. A maioria dos dispositivos portáteis está atualmente projetada para questões de saúde, como a monitorização do nível de glicose e batimento cardíaco. O objetivo deste trabalho passa por definir e implementar um dispositivo wearable para aplicações de saúde com um conjunto de funcionalidades para monitorização dos sinais vitais do utilizador. Posteriormente esta base pode ser aplicada em cenários de aplicação distintos, em que todos os dispositivos comunicam entre si, e fazem o reencaminhamento da informação para onde mais interessar. Foi desenhado e implementado hardware e software, para a construção de aplicações capazes de realizar a monitorização do batimento cardíaco, temperatura e humidade corporal, deteção de quedas, qualidade do sono, e chamadas de emergência. Este trabalho aborda os diferentes cenários e aplicações da utilização deste dispositivo, invocando as necessidades específicas de cada situação, sendo estas necessidades trabalhadas e transformadas em características e especificações do sistema. A plataforma de hardware e software permite criar um ecossistema de aplicações, permitindo usar todas as infraestruturas do sistema desenvolvido em futuros cenários de aplicação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility of detecting acute infection and immunity using body fluids that are easier to collect than blood, mainly in children, would facilitate the investigation and follow-up of outbreaks of hepatitis A (HAV). Our study was carried out to evaluate the detection of anti-HAV IgM, IgA and total antibodies in saliva using serum samples as reference. Forty three paired serum and saliva samples were analyzed. From this total, 24 samples were obtained from children and 1 from one adult during the course of acute hepatitis A; an additional 18 samples were obtained from health professionals from Adolfo Lutz Institute. The sensitivity to detect anti-HAV IgM was 100% (95%CI: 79.1 to 100.0%), employing saliva as clinical samples. In detecting anti-HAV IgA, the sensitivity was 80.8% (95%CI: 60.0 to 92.7%) and for the total antibodies was 82.1% (95%CI: 62.4 to 93.2%). The specificity was 100% for each. The rate of agreement was high comparing the results of serum and saliva samples for detecting HAV antibodies. We conclude that saliva is an acceptable alternative specimen for diagnosing acute hepatitis A infection, and for screening individuals to receive hepatitis A vaccine or immunoglobulin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop a polymerase chain reaction (PCR) protocol for the detection of Salmonella in artificially contaminated chicken meat. Tests were performed with different dilutions of Salmonella Typhimurium or Salmonella Enteritidis cells (10-7, 10-8 or 10-9 CFU/mL) inoculated in chicken meat samples, in order to establish the limits of detection, incubation times (0, 6, 8 and 24 hours of pre-enrichment in PBW 1%) and three DNA extraction protocols (phenol-chloroform, thermal treatment and thermal treatment and Sephaglass). The assay was able to detect until 10-9 CFU/mL of initial dilution of Salmonella cells inoculated in chicken meat, which allows detection of Salmonella within 48 hours, including 24 hours of pre-enrichment and using the phenol-chloroform DNA extraction protocol. As the results are obtained in a shorter time period than that of microbiological culture, this procedure will be useful in the methodology for detection of Salmonella in chicken.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eighty-one cerebrospinal fluid (CSF) samples mainly from cases of aseptic meningitis and motor deficiency syndrome were sent to the Virology Section of Evandro Chagas Institute, Belém Pará, in the period of January 1995 to January 1996 in order to isolate viruses. All samples were inoculated onto HEp-2 cell culture and newborn mice, with negative results. The probability of isolating viruses by these methods is reduced because of the low concentration of viral particles in these specimens. In order to obtain more information about the etiology of these cases, a group of 23 samples were selected to be tested by a more sensitive technique than the virus isolation - the reverse transcription polymerase chain reaction (RT-PCR). Specific primers directed to conserved regions in the enterovirus genome were used, considering that this group of viruses is frequently associated with these neurological disorder. The age of the patients ranged from 1 to 55 years and nearly all of them lived in Belém, State of Pará, North of Brazil. Of 15 samples analyzed by RT PCR nine (60%) were positive; of these, 6 (66.6%) had motor deficiency and 3 (33.3%) developed aseptic meningitis. These results show that it is important to investigate enterovirus as cause of these syndromes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho enquadra-se na temática de segurança contra incêndio em edifícios e consiste num estudo de caso de projeto de deteção e extinção de incêndio num Data Center. Os objetivos deste trabalho resumem-se à realização de um estudo sobre o estado da arte da extinção e deteção automática de incêndio, ao desenvolvimento de uma ferramenta de software de apoio a projetos de extinção por agentes gasosos, como também à realização de um estudo e uma análise da proteção contra incêndios em Data Centers. Por último foi efetuado um estudo de caso. São abordados os conceitos de fogo e de incêndio, em que um estudo teórico à temática foi desenvolvido, descrevendo de que forma pode o fogo ser originado e respetivas consequências. Os regulamentos nacionais relativos à Segurança Contra Incêndios em Edifícios (SCIE) são igualmente abordados, com especial foco nos Sistemas Automáticos de Deteção de Incêndio (SADI) e nos Sistemas Automáticos de Extinção de Incêndio (SAEI), as normas nacionais e internacionais relativas a esta temática também são mencionadas. Pelo facto de serem muito relevantes para o desenvolvimento deste trabalho, os sistemas de deteção de incêndio são exaustivamente abordados, mencionando características de equipamentos de deteção, técnicas mais utilizadas como também quais os aspetos a ter em consideração no dimensionamento de um SADI. Quanto aos meios de extinção de incêndio foram mencionados quais os mais utilizados atualmente, as suas vantagens e a que tipo de fogo se aplicam, com especial destaque para os SAEI com utilização de gases inertes, em que foi descrito como deve ser dimensionado um sistema deste tipo. Foi também efetuada a caracterização dos Data Centers para que seja possível entender quais as suas funcionalidades, a importância da sua existência e os aspetos gerais de uma proteção contra incêndio nestas instalações. Por último, um estudo de caso foi desenvolvido, um SADI foi projetado juntamente com um SAEI que utiliza azoto como gás de extinção. As escolhas e os sistemas escolhidos foram devidamente justificados, tendo em conta os regulamentos e normas em vigor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DNA amplification by the polymerase chain reaction (PCR) was applied in the investigation of the presence of Leishmania (Kinetoplastida: Trypanosomatidae) parasites in single phlebotomine sandflies. Three phlebotomine/parasite pairs were used: Lutzomyia longipalpis/Leishmania chagasi, Lutzomyia migonei/Leishmania amazonensis and Lutzomyia migonei/Leishmania braziliensis, all of them incriminated in the transmission of visceral or cutaneous leishmaniasis. DNA extraction was performed with whole insects, with no need of previous digestive tract dissection or pooling specimens. The presence of either mouse blood in the digestive tract of the sandflies or the digestive tract itself did not interfere in the PCR. Infection by as few as 10 Leishmania sp. per individual were sufficient for DNA amplification with genus-specific primers. Using primers for L. braziliensis and L. mexicana complexes, respectively, it was possible to discriminate between L. braziliensis and L. amazonensis in experimentally infected vectors (L. migonei).