980 resultados para SPECTROMETER


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Depletion of highly abundant proteins is an approved step in blood plasma analysis by mass spectrometry (MS). In this study, we explored a precipitation and differential protein solubility approach as a fractionation strategy for abundant protein removal from plasma. Total proteins from plasma were precipitated with 90% saturated ammonium sulfate, followed by differential solubilization in 55% and 35% saturated ammonium sulfate solutions. Using a four hour liquid chromatography (LC) gradient and an LTQ-Orbitrap XL mass spectrometer, a total of 167 and 224 proteins were identified from the 55% and 35% ammonium sulfate fractions, whereas 235 proteins were found in the remaining protein fractions with at least two unique peptides. SDS-PAGE and exclusive total spectrum counts from LC-MS/MS analyses clearly showed that majority of the abundant plasma proteins were solubilized in 55% and 35% ammonium sulfate solutions, indicating that the remaining protein fraction is of potential interest for identification of less abundant plasma proteins. Serum albumin, serotransferrin, alpha-1-antitrypsin and transthyretin were the abundant proteins that were highly enriched in 55% ammonium sulfate fractions. Immunoglobulins, complement system proteins, and apolipoproteins were among other abundant plasma proteins that were enriched in 35% ammonium sulfate fractions. In the remaining protein fractions a total of 40 unique proteins were identified of which, 32 proteins were identified with at least 10 exclusive spectrum counts. According to PeptideAtlas, 9 of these 32 proteins were estimated to be present at low μg ml(-1) (0.12-1.9 μg ml(-1)) concentrations in the plasma, and 17 at low ng ml(-1) (0.1-55 ng ml(-1)) range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context. The detection and measurement of gamma-ray lines from the decaychain of 56Ni provides unique information about the explosionin supernovae. SN2014J at 3.3 Mpc is a sufficiently-nearby supernova oftype Ia so that such measurements have been feasible with the gamma-rayspectrometer SPI on ESA's INTEGRAL gamma-ray observatory.

Aims:The 56Ni freshly produced in the supernova is understood topower the optical light curve, because it emits gamma rays upon itsradioactive decay first to 56Co and then to 56Fe.Gamma-ray lines from 56Co decay are expected to becomedirectly visible through the white dwarf material several weeks afterthe explosion, as they progressively penetrate the overlying material ofthe supernova envelope, which is diluted as it expands. The lines areexpected to be Doppler-shifted or broadened from the kinematics of the56Ni ejecta. We aim to exploit high-resolution gamma-rayspectroscopy with the SPI spectrometer on INTEGRAL toward constrainingthe 56Ni distribution and kinematics in this supernova.

Methods: We use the observations with the SPI spectrometer onINTEGRAL, together with an improved instrumental background method.

Results: We detect the two main lines from 56Co decay at847 and 1238 keV, which are significantly Doppler-broadened, and atintensities (3.65 ± 1.21) × 10-4 and (2.27± 0.69) × 10-4 ph cm-2s-1, respectively, at their brightness maximum. We measuretheir rise toward a maximum after about 60-100 days and a declinethereafter. The intensity ratio of the two lines is found to beconsistent with expectations from 56Co decay (0.62 ±0.28 at brightness maximum, the expected ratio is 0.68). We find thatthe broad lines seen in the late, gamma-ray transparent phase are notrepresentative of the early gamma-ray emission, and notice instead thatthe emission spectrum is complex and irregular until the supernova isfully transparent to gamma rays, with progressive uncovering of the bulkof 56Ni. We infer that the explosion morphology is notspherically symmetric, both in the distribution of 56Ni andin the unburnt material which occults the 56Co emission.After we compare light curves from different plausible models, theresulting 56Ni mass is determined to be 0.49 ± 0.09M⊙.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper presents the calibration of Fuji BAS-TR image plate (IP) response to high energy carbon ions of different charge states by employing an intense laser-driven ion source, which allowed access to carbon energies up to 270 MeV. The calibration method consists of employing a Thomson parabola spectrometer to separate and spectrally resolve different ion species, and a slotted CR-39 solid state detector overlayed onto an image plate for an absolute calibration of the IP signal. An empirical response function was obtained which can be reasonably extrapolated to higher ion energies. The experimental data also show that the IP response is independent of ion charge states.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Evidence that persistent environmental pollutants may target the male reproductive system is increasing. The male reproductive system is regulated by secretion of testosterone by testicular Leydig cells, and perturbation of Leydig cell function may have ultimate consequences. 3-Methylsulfonyl-DDE (3-MeSO2-DDE) is a potent adrenal toxicants formed from the persistent insecticide DDT. Although studies have revealed the endocrine disruptive effect of 3-MeSO2-DDE, the underlying mechanisms at cellular level in steroidogenic Leydig cells remains to be established. The current study addresses the effect of 3-MeSO2-DDE on viability, hormone production and proteome response of primary neonatal porcine Leydig cells. The AlamarBlue™ assay was used to evaluate cell viability. Solid phase radioimmunoassay was used to measure concentration of hormones produced by both unstimulated and Luteinizing hormone (LH)-stimulated Leydig cells following 48h exposure. Protein samples from Leydig cells exposed to a non-cytotoxic concentration of 3-MeSO2-DDE (10μM) were subjected to nano-LC-MS/MS and analyzed on a Q Exactive mass spectrometer and quantified using label-free quantitative algorithm. Gene Ontology (GO) and Ingenuity Pathway Analysis (IPA) were carried out for functional annotation and identification of protein interaction networks. 3-MeSO2-DDE regulated Leydig cell steroidogenesis differentially depending on cell culture condition. Whereas its effect on testosterone secretion at basal condition was stimulatory, the effect on LH-stimulated cells was inhibitory. From triplicate experiments, a total of 6804 proteins were identified in which the abundance of 86 proteins in unstimulated Leydig cells and 145 proteins in LH-stimulated Leydig cells was found to be significantly regulated in response to 3-MeSO2-DDE exposure. These proteins not only are the first reported in relation to 3-MeSO2-DDE exposure, but also display small number of proteins shared between culture conditions, suggesting the action of 3-MeSO2-DDE on several targeted pathways, including mitochondrial dysfunction, oxidative phosphorylation, EIF2-signaling, and glutathione-mediated detoxification. Further identification and characterization of these proteins and pathways may build our understanding to the molecular basis of 3-MeSO2-DDE induced endocrine disruption in Leydig cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has previously been reported that the a-defensins, found in the granules of polymorphonuclear leukocytes (neutrophils/ PMNs), are cytolytic for human tumour cells in vitro. Objective: To identify and quantify the a- defensins, HNP-1, HNP-2 and HNP-3 in healthy and tumour tissue from patients with oral squamous cell carcinoma using HPLC, mass spectrometry and amino acid sequencing. Methods: All patients (n=5) were diagnosed with oral squamous cell carcinoma of the tongue.Biopsy tissue from the site of the tumour (n=5) and a non-affected region of the tongue (n=5) was snap frozen and subsequently stored at -70 ºC until analysed. Peptides were extracted from the 10 tissue biopsies using acidified ethanol. Peptide extracts were separated by reverse-phase HPLC . All tumour and control tissue samples were individually analysed under identical conditions with a flow rate of l ml/min, ambient column temperature and absorbance detection at 214 and 280 nm. Fractions (1ml) were collected automatically. HPLC fractions were analysed by MALDI-MS using a linear time-of-flight Voyager DE-mass spectrometer (PerSeptive Biosystems, UK). Using this system the detection limit was 10 fmol. Peptides with molecular masses corresponding to those reported for the a-defensins were deemed of interest and were further subject to complete structural analysis by automated Edman degradation using an Applied Biosystems 491 Procise microsequencer. Results: MALDI-MS revealed a triad of peptides of molecular masses 3442 Da, 3371 Da and 3486 Da in both healthy and tumour tissue. Full length sequence data were obtained for the three a-defensins, unequivocally identifying their presence in both tumour and healthy tissue. Analysis of the MALDI-MS and sequence data indicated that the a-defensins were overexpressed (up to 12 fold) in tumour tissue. Conclusion: This study demonstrates the feasibility of screening tumour tissue for novel peptides/proteins using HPLC and MALDI-MS.The role of a-defensins in oral squamous cell carcinoma of the tongue requires further investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulsed beams of energetic x-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and x-ray beam generation. Measurements and Monte Carlo radiation transport simulations show that neutron yield is increased by a factor ∼2 when a 1 mm copper foil is placed behind a 2 mm lithium foil, compared to using a 2 cm block of lithium only. We explore x-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using >1 ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte Carlo code. We also demonstrate the unique capability of laser-driven x-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10 ps drive pulse is presented for the first time, demonstrating that features of 200 μm size are resolved when projected at high magnification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate the potential use of line ratio diagnostics to evaluate electron temperature in either helium or helium seeded argon plasmas. Plasmas are produced in a helicon plasma source. A rf compensated Langmuir probe is used to measure both the electron temperature and plasma density while a spectrometer is used to measure He I line intensities from the plasma. For all plasma densities where the electron temperature remains at 5 ± 1 eV, three He line ratios are measured. Each experimental ratio is compared with the prediction of three different collisional radiative models. One of these models makes uses of recent R-matrix with pseudo-states calculations for collisional rate coefficients. A discussion related to the different observations and model predictions is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have measured mass spectra for positive ions for low-energy electron impact on thymine using a reflectron time-of-flight mass spectrometer. Using computer controlled data acquisition, mass spectra have been acquired for electron impact energies up to 100 eV in steps of 0.5 eV. Ion yield curves for most of the fragment ions have been determined by fitting groups of adjacent peaks in the mass spectra with sequences of normalized Gaussians. The ion yield curves have been normalized by comparing the sum of the ion yields to the average of calculated total ionization cross sections. Appearance energies have been determined. The nearly equal appearance energies of 83 u and 55 u observed in the present work strongly indicate that near threshold the 55 u ion is formed directly by the breakage of two bonds in the ring, rather than from a successive loss of HNCO and CO from the parent ion. Likewise 54 u is not formed by CO loss from 82 u. The appearance energies are in a number of cases consistent with the loss of one or more hydrogen atoms from a heavier fragment, but 70 u is not formed by hydrogen loss from 71 u.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado, Qualidade em Análises, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a novel data analysis strategy which combined with subcellular fractionation and liquid chromatography-mass spectrometry (LC-MS) based proteomics provides a simple and effective workflow for global drug profiling. Five subcellular fractions were obtained by differential centrifugation followed by high resolution LC-MS and complete functional regulation analysis. The methodology combines functional regulation and enrichment analysis into a single visual summary. The workflow enables improved insight into perturbations caused by drugs. We provide a statistical argument to demonstrate that even crude subcellular fractions leads to improved functional characterization. We demonstrate this data analysis strategy on data obtained in a MS-based global drug profiling study. However, this strategy can also be performed on other types of large scale biological data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multiclass analysis method was optimized in order to analyze pesticides traces by gas chromatography with ion-trap and tandem mass spectrometry (GC-MS/MS). The influence of some analytical parameters on pesticide signal response was explored. Five ion trap mass spectrometry (IT-MS) operating parameters, including isolation time (IT), excitation voltage (EV), excitation time (ET),maximum excitation energy or “q” value (q), and isolationmass window (IMW) were numerically tested in order to maximize the instrument analytical signal response. For this, multiple linear regression was used in data analysis to evaluate the influence of the five parameters on the analytical response in the ion trap mass spectrometer and to predict its response. The assessment of the five parameters based on the regression equations substantially increased the sensitivity of IT-MS/MS in the MS/MS mode. The results obtained show that for most of the pesticides, these parameters have a strong influence on both signal response and detection limit.Using the optimized method, a multiclass pesticide analysis was performed for 46 pesticides in a strawberry matrix. Levels higher than the limit established for strawberries by the European Union were found in some samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Certain materials used and produced in a wide range of non-nuclear industries contain enhanced activity concentrations of natural radionuclides. In particular, electricity production from coal is one of the major sources of increased human exposure to naturally occurring radioactive materials. A methodology was developed to assess the radiological impact due to natural radiation background. The developed research was applied to a specific case study, the Sines coal-fired power plant, located in the southwest coastline of Portugal. Gamma radiation measurements were carried out with two different instruments: a sodium iodide scintillation detector counter (SPP2 NF, Saphymo) and a gamma ray spectrometer with energy discrimination (Falcon 5000, Canberra). Two circular survey areas were defined within 20 km of the power plant. Forty relevant measurements points were established within the sampling area: 15 urban and 25 suburban locations. Additionally, ten more measurements points were defined, mostly at the 20-km area. The registered gamma radiation varies from 20 to 98.33 counts per seconds (c.p.s.) corresponding to an external gamma exposure rate variable between 87.70 and 431.19 nGy/h. The highest values were measured at locations near the power plant and those located in an area within the 6 and 20 km from the stacks. In situ gamma radiation measurements with energy discrimination identified natural emitting nuclides as well as their decay products (Pb-212, Pb-2142, Ra-226, Th-232, Ac-228, Th-234, Pa-234, U- 235, etc.). According to the results, an influence from the stacks emissions has been identified both qualitatively and quantitatively. The developed methodology accomplished the lack of data in what concerns to radiation rate in the vicinity of Sines coal-fired power plant and consequently the resulting exposure to the nearby population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Certain materials used and produced in a wide range of non-nuclear industries contain enhanced activity concentrations of natural radionuclides. In particular, electricity production from coal is one of the major sources of increased exposure to man from enhanced naturally occurring materials. Over the past decades there has been some discussion about the elevated natural background radiation in the area near coal-fired power plants due to high uranium and thorium content present in coal. This work describes the methodology developed to assess the radiological impact due to natural radiation background increasing levels, potentially originated by a coal-fired power plant’s operation. Gamma radiation measurements have been done with two different instruments: a scintillometer (SPP2 NF, Saphymo) and a gamma ray spectrometer with energy discrimination (Falcon 5000, Canberra). A total of 40 relevant sampling points were established at locations within 20 km from the power plant: 15 urban and 25 suburban measured stations. The highest values were measured at the sampling points near to the power plant and those located in the area within the 6 and 20 km from the stacks. This may be explained by the presence of a huge coal pile (1.3 million tons) located near the stacks contributing to the dispersion of unburned coal and, on the other hand, the height of the stacks (225 m) which may influence ash’s dispersion up to a distance of 20 km. In situ gamma radiation measurements with energy discrimination identified natural emitting nuclides as well as their decay products (212Pb, 214Pb, 226Ra 232Th, 228Ac, 234Th 234Pa, 235U, etc.). This work has been primarily done to in order to assess the impact of a coal-fired power plant operation on the background radiation level in the surrounding area. According to the results, an increase or at least an influence has been identified both qualitatively and quantitatively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper aims to survey metal concentrations in soils in the vicinity of a coal-firedpower plant located in southwest of Portugal. Two annual sampling campaigns were carried out to measure a hypothetical soil contamination around the coal plant. The sampling area was divided into two subareas, both centered in the emission source, delimited by two concentric circles with radius of 6 km and 20 km. About 40 samplings points were defined in the influence area. Metals measurements were performed with a portable analytical X-ray dispersive energy fluorescence spectrometer identifying about 20 different elements in each sampling point. The most relevant elements measured included As, Cu, Fe, Hg, Pb, Ti and Zn in both sampling areas. Considering the results obtained in the first sampling campaign, arsenic is predominantly higher within the 6-20 km sampling area. The second sampling campaign showed that both sampling areas presented relatively similar metal concentrations except for Fe, Mn, Sr and Zn which concentration is higher within the 6-20 km sampling area. Also, As, Fe, Mn and Ti concentrations decreased significantly from the first to the second sampling campaign and their concentration were predominately higher in the NE-E and E-SE directions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho consistiu no desenvolvimento e caracterização de sensores potenciométricos com base em polímeros de impressão molecular para a determinação de um antibiótico, a norfloxacina, em aquacultura. A simplicidade, o baixo custo e a interação rápida e reversível dos sensores potenciométricos com os analitos fizeram com que este fosse o tipo de sensor escolhido. O material sensor foi obtido por tecnologia de impressão molecular, baseada em polimerização em bulk, em que a NOR foi a molécula molde e foram utilizados como monómeros para autoconstrução dos sensores o pirrol, isoladamente, ou em conjunto com partículas de sílica gel funcionalizadas com 3-aminopropil. Também foi obtido material sensor, para controlo, em que a molécula molde NOR não estava presente (NIP). As características dos materiais sensores foram sujeitas a análise de microscopia eletrónica SEM e análise por espectrómetro de infravermelhos com transformada de Fourier. Os materiais sensores foram incluídos em membranas poliméricas, que seriam incorporadas em elétrodos. A avaliação do desempenho dos elétrodos foi feita através de curvas de calibração em diferentes meios (PBS, MES e HEPES). Também foi efetuada com sucesso a análise da sensibilidade dos elétrodos em água dopada. As diversas avaliações e análises efetuadas levaram a concluir que o MIP de pirrol com aditivo aniónico, foi o material sensor testado que permitiu obter melhores propriedades de resposta.