968 resultados para Respiratory and olfactory epithelia


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Weekly report of the Iowa Influenza Surveillance Network produced by the Iowa Department of Public Health.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Weekly report of the Iowa Influenza Surveillance Network produced by the Iowa Department of Public Health.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mortality of the acute respiratory distress syndrome (ARDS) remains extremely high and only few evidence-based specific treatments are currently available. Protective mechanical ventilation has emerged as the comer stone of the management of ARDS to avoid the occurrence of ventilation-induced lung injuries (VILI). Mechanical ventilation in the prone position has often been considered as a rescue therapy reserved to refractory hypoxemia. Since the publication of the PROSEVA study in 2013, early prone positioning for mechanical ventilation should be recommended to improve survival of patients with severe ARDS. In this article, both the theoretical and practical aspects of mechanical ventilation in prone position are reviewed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Recent findings suggest an association between exposure to cleaning products and respiratory dysfunctions including asthma. However, little information is available about quantitative airborne exposures of professional cleaners to volatile organic compounds deriving from cleaning products. During the first phases of the study, a systematic review of cleaning products was performed. Safety data sheets were reviewed to assess the most frequently added volatile organic compounds. It was found that professional cleaning products are complex mixtures of different components (compounds in cleaning products: 3.5 ± 2.8), and more than 130 chemical substances listed in the safety data sheets were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%), skin (50%) and by ingestion (60%) were the most reported. Monoethanolamine, a strong irritant and known to be involved in sensitizing mechanisms as well as allergic reactions, is frequently added to cleaning products. Monoethanolamine determination in air has traditionally been difficult and air sampling and analysis methods available were little adapted for personal occupational air concentration assessments. A convenient method was developed with air sampling on impregnated glass fiber filters followed by one step desorption, gas chromatography and nitrogen phosphorous selective detection. An exposure assessment was conducted in the cleaning sector, to determine airborne concentrations of monoethanolamine, glycol ethers, and benzyl alcohol during different cleaning tasks performed by professional cleaning workers in different companies, and to determine background air concentrations of formaldehyde, a known indoor air contaminant. The occupational exposure study was carried out in 12 cleaning companies, and personal air samples were collected for monoethanolamine (n=68), glycol ethers (n=79), benzyl alcohol (n=15) and formaldehyde (n=45). All but ethylene glycol mono-n-butyl ether air concentrations measured were far below (<1/10) of the Swiss eight hours occupational exposure limits, except for butoxypropanol and benzyl alcohol, where no occupational exposure limits were available. Although only detected once, ethylene glycol mono-n-butyl ether air concentrations (n=4) were high (49.5 mg/m3 to 58.7 mg/m3), hovering at the Swiss occupational exposure limit (49 mg/m3). Background air concentrations showed no presence of monoethanolamine, while the glycol ethers were often present, and formaldehyde was universally detected. Exposures were influenced by the amount of monoethanolamine in the cleaning product, cross ventilation and spraying. The collected data was used to test an already existing exposure modeling tool during the last phases of the study. The exposure estimation of the so called Bayesian tool converged with the measured range of exposure the more air concentrations of measured exposure were added. This was best described by an inverse 2nd order equation. The results suggest that the Bayesian tool is not adapted to predict low exposures. The Bayesian tool should be tested also with other datasets describing higher exposures. Low exposures to different chemical sensitizers and irritants should be further investigated to better understand the development of respiratory disorders in cleaning workers. Prevention measures should especially focus on incorrect use of cleaning products, to avoid high air concentrations at the exposure limits. - De récentes études montrent l'existence d'un lien entre l'exposition aux produits de nettoyages et les maladies respiratoires telles que l'asthme. En revanche, encore peu d'informations sont disponibles concernant la quantité d'exposition des professionnels du secteur du nettoyage aux composants organiques volatiles provenant des produits qu'ils utilisent. Pendant la première phase de cette étude, un recueil systématique des produits professionnels utilisés dans le secteur du nettoyage a été effectué. Les fiches de données de sécurité de ces produits ont ensuite été analysées, afin de répertorier les composés organiques volatiles les plus souvent utilisés. Il a été mis en évidence que les produits de nettoyage professionnels sont des mélanges complexes de composants chimiques (composants chimiques dans les produits de nettoyage : 3.5 ± 2.8). Ainsi, plus de 130 substances listées dans les fiches de données de sécurité ont été retrouvées dans les 105 produits répertoriés. Les principales classes de substances chimiques identifiées étaient les parfums, les éthers de glycol, les agents de surface et les solvants; dans une moindre mesure, les phosphates, les sels, les détergents, les régulateurs de pH, les acides et les bases ont été identifiés. Plus de 75% des produits répertoriés contenaient des substances décrites comme irritantes (Xi), 64% nuisibles (Xn) et 28% corrosives (C). Les risques pour les yeux (59%), la peau (50%) et par ingestion (60%) était les plus mentionnés. La monoéthanolamine, un fort irritant connu pour être impliqué dans les mécanismes de sensibilisation tels que les réactions allergiques, est fréquemment ajouté aux produits de nettoyage. L'analyse de la monoéthanolamine dans l'air a été habituellement difficile et les échantillons d'air ainsi que les méthodes d'analyse déjà disponibles étaient peu adaptées à l'évaluation de la concentration individuelle d'air aux postes de travail. Une nouvelle méthode plus efficace a donc été développée en captant les échantillons d'air sur des filtres de fibre de verre imprégnés, suivi par une étape de désorption, puis une Chromatographie des gaz et enfin une détection sélective des composants d'azote. Une évaluation de l'exposition des professionnels a été réalisée dans le secteur du nettoyage afin de déterminer la concentration atmosphérique en monoéthanolamine, en éthers de glycol et en alcool benzylique au cours des différentes tâches de nettoyage effectuées par les professionnels du nettoyage dans différentes entreprises, ainsi que pour déterminer les concentrations atmosphériques de fond en formaldéhyde, un polluant de l'air intérieur bien connu. L'étude de l'exposition professionnelle a été effectuée dans 12 compagnies de nettoyage et les échantillons d'air individuels ont été collectés pour l'éthanolamine (n=68), les éthers de glycol (n=79), l'alcool benzylique (n=15) et le formaldéhyde (n=45). Toutes les substances mesurées dans l'air, excepté le 2-butoxyéthanol, étaient en-dessous (<1/10) de la valeur moyenne d'exposition aux postes de travail en Suisse (8 heures), excepté pour le butoxypropanol et l'alcool benzylique, pour lesquels aucune valeur limite d'exposition n'était disponible. Bien que détecté qu'une seule fois, les concentrations d'air de 2-butoxyéthanol (n=4) étaient élevées (49,5 mg/m3 à 58,7 mg/m3), se situant au-dessus de la frontière des valeurs limites d'exposition aux postes de travail en Suisse (49 mg/m3). Les concentrations d'air de fond n'ont montré aucune présence de monoéthanolamine, alors que les éthers de glycol étaient souvent présents et les formaldéhydes quasiment toujours détectés. L'exposition des professionnels a été influencée par la quantité de monoéthanolamine présente dans les produits de nettoyage utilisés, par la ventilation extérieure et par l'emploie de sprays. Durant la dernière phase de l'étude, les informations collectées ont été utilisées pour tester un outil de modélisation de l'exposition déjà existant, l'outil de Bayesian. L'estimation de l'exposition de cet outil convergeait avec l'exposition mesurée. Cela a été le mieux décrit par une équation du second degré inversée. Les résultats suggèrent que l'outil de Bayesian n'est pas adapté pour mettre en évidence les taux d'expositions faibles. Cet outil devrait également être testé avec d'autres ensembles de données décrivant des taux d'expositions plus élevés. L'exposition répétée à des substances chimiques ayant des propriétés irritatives et sensibilisantes devrait être investiguée d'avantage, afin de mieux comprendre l'apparition de maladies respiratoires chez les professionnels du nettoyage. Des mesures de prévention devraient tout particulièrement être orientées sur l'utilisation correcte des produits de nettoyage, afin d'éviter les concentrations d'air élevées se situant à la valeur limite d'exposition acceptée.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Invasive studies suggest that healthy children living at high altitude display pulmonary hypertension, but the data to support this assumption are sparse. Nitric oxide (NO) synthesized by the respiratory epithelium regulates pulmonary artery pressure, and its synthesis was reported to be increased in Aymara high-altitude dwellers. We hypothesized that pulmonary artery pressure will be lower in Aymara children than in children of European ancestry at high altitude, and that this will be related to increased respiratory NO. We therefore compared pulmonary artery pressure and exhaled NO (a marker of respiratory epithelial NO synthesis) between large groups of healthy children of Aymara (n = 200; mean +/- SD age, 9.5 +/- 3.6 years) and European ancestry (n = 77) living at high altitude (3,600 to 4,000 m). We also studied a group of European children (n = 29) living at low altitude. The systolic right ventricular to right atrial pressure gradient in the Aymara children was normal, even though significantly higher than the gradient measured in European children at low altitude (22.5 +/- 6.1 mm Hg vs 17.7 +/- 3.1 mm Hg, p < 0.001). In children of European ancestry studied at high altitude, the pressure gradient was 33% higher than in the Aymara children (30.0 +/- 5.3 mm Hg vs 22.5 +/- 6.1 mm Hg, p < 0.0001). In contrast to what was expected, exhaled NO tended to be lower in Aymara children than in European children living at the same altitude (12.4 +/- 8.8 parts per billion [ppb] vs 16.1 +/- 11.1 ppb, p = 0.06) and was not related to pulmonary artery pressure in either group. Aymara children are protected from hypoxic pulmonary hypertension at high altitude. This protection does not appear to be related to increased respiratory NO synthesis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The new Swiss Chronic Obstructive Pulmonary Disease (COPD) Guidelines are based on a previous version, which was published 10 years ago. The Swiss Respiratory Society felt the need to update the previous document due to new knowledge and novel therapeutic developments about this prevalent and important disease. The recommendations and statements are based on the available literature, on other national guidelines and, in particular, on the GOLD (Global Initiative for Chronic Obstructive Lung Disease) report. Our aim is to advise pulmonary physicians, general practitioners and other health care workers on the early detection and diagnosis, prevention, best symptomatic control, and avoidance of COPD as well as its complications and deterioration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To assess the outcome in patients with olfactory neuroblastoma (ONB). Methods and Materials: Seventy-seven patients treated for nonmetastatic ONB between 1971 and 2004 were included. According to Kadish classification, there were 11 patients with Stage A, 29 with Stage B, and 37 with Stage C. T-classification included 9 patients with T1, 26 with T2, 16 with T3, 15 with T4a, and 11 with T4b tumors. Sixty-eight patients presented with N0 (88%) disease. Results: Most of the patients (n = 56, 73 %) benefited from surgery (S), and total excision was possible in 44 patients (R0 in 32, R1 in 13, R2 in 11). All but five patients benefited from RT, and chemotherapy was given in 21(27%). Median follow-up period was 72 months (range, 6-315). The 5-year overall survival (OS), disease-free survival (DES), locoregional control, and local control were 64%, 57%, 62%, and 70%, respectively. In univariate analyses, favorable factors were Kadish A or B disease, T1 T3 tumors, no nodal involvement, curative surgery, R0/R1 resection, and RT-dose 54 Gy or higher. Multivariate analysis revealed that the best independent factors predicting the outcome were T1 T3, N0, R0/R1 resection, and total RT dose (54 Gy or higher). Conclusion: In this multicenter retrospective study, patients with ONB treated with R0 or R1 surgical resection followed by at least 54-Gy postoperative RT had the best outcome. Novel strategies including concomitant chemotherapy and/or higher dose RT should be prospectively investigated in this rare disease for which local failure remains a problem.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Lung transplant recipients are frequently exposed to respiratory viruses and are particularly at risk for severe complications. The aim of this study was to assess the association among the presence of a respiratory virus detected by molecular assays in bronchoalveolar lavage (BAL) fluid, respiratory symptoms, and acute rejection in adult lung transplant recipients. Methods: Upper (nasopharyngeal swab) and lower (BAL) respiratory tract specimens from 77 lung transplant recipients enrolled in a cohort study and undergoing bronchoscopy with BAL and transbronchial biopsies were screened using 17 different polymerase chain reaction-based assays. Result: BAL fluid and biopsy specimens from 343 bronchoscopic procedures performed in 77 patients were analyzed. We also compared paired nasopharyngeal and BAL fluid specimens collected in a subgroup of 283 cases. The overall viral positivity rate was 29.3% in the upper respiratory tract specimens and 17.2% in the BAL samples (). We observed a significant association P < .001 between the presence of respiratory symptoms and positive viral detection in the lower respiratory tract (Pp. 012). Conversely, acute rejection was not associated with the presence of viral infection (odds ratio, 0.41; 95% confidence interval, 0.20-0.88). The recovery of lung function was significantly slower when acute rejection and viral infection were both present. Conclusions: A temporal relationship exists between acute respiratory symptoms and positive viral nucleic acid detection in BAL fluid from lung transplant recipients. We provide evidence suggesting that respiratory viruses are not associated with acute graft rejection during the acute phase of infection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: Before a patient can be connected to a mechanical ventilator, the controls of the apparatus need to be set up appropriately. Today, this is done by the intensive care professional. With the advent of closed loop controlled mechanical ventilation, methods will be needed to select appropriate start up settings automatically. The objective of our study was to test such a computerized method which could eventually be used as a start-up procedure (first 5-10 minutes of ventilation) for closed-loop controlled ventilation. DESIGN: Prospective Study. SETTINGS: ICU's in two adult and one children's hospital. PATIENTS: 25 critically ill adult patients (age > or = 15 y) and 17 critically ill children selected at random were studied. INTERVENTIONS: To stimulate 'initial connection', the patients were disconnected from their ventilator and transiently connected to a modified Hamilton AMADEUS ventilator for maximally one minute. During that time they were ventilated with a fixed and standardized breath pattern (Test Breaths) based on pressure controlled synchronized intermittent mandatory ventilation (PCSIMV). MEASUREMENTS AND MAIN RESULTS: Measurements of airway flow, airway pressure and instantaneous CO2 concentration using a mainstream CO2 analyzer were made at the mouth during application of the Test-Breaths. Test-Breaths were analyzed in terms of tidal volume, expiratory time constant and series dead space. Using this data an initial ventilation pattern consisting of respiratory frequency and tidal volume was calculated. This ventilation pattern was compared to the one measured prior to the onset of the study using a two-tailed paired t-test. Additionally, it was compared to a conventional method for setting up ventilators. The computer-proposed ventilation pattern did not differ significantly from the actual pattern (p > 0.05), while the conventional method did. However the scatter was large and in 6 cases deviations in the minute ventilation of more than 50% were observed. CONCLUSIONS: The analysis of standardized Test Breaths allows automatic determination of an initial ventilation pattern for intubated ICU patients. While this pattern does not seem to be superior to the one chosen by the conventional method, it is derived fully automatically and without need for manual patient data entry such as weight or height. This makes the method potentially useful as a start up procedure for closed-loop controlled ventilation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Results from cohort studies evaluating the severity of respiratory viral co-infections are conflicting. We conducted a systematic review and meta-analysis to assess the clinical severity of viral co-infections as compared to single viral respiratory infections. METHODS: We searched electronic databases and other sources for studies published up to January 28, 2013. We included observational studies on inpatients with respiratory illnesses comparing the clinical severity of viral co-infections to single viral infections as detected by molecular assays. The primary outcome reflecting clinical disease severity was length of hospital stay (LOS). A random-effects model was used to conduct the meta-analyses. RESULTS: Twenty-one studies involving 4,280 patients were included. The overall quality of evidence applying the GRADE approach ranged from moderate for oxygen requirements to low for all other outcomes. No significant differences in length of hospital stay (LOS) (mean difference (MD) -0.20 days, 95% CI -0.94, 0.53, p = 0.59), or mortality (RR 2.44, 95% CI 0.86, 6.91, p = 0.09) were documented in subjects with viral co-infections compared to those with a single viral infection. There was no evidence for differences in effects across age subgroups in post hoc analyses with the exception of the higher mortality in preschool children (RR 9.82, 95% CI 3.09, 31.20, p<0.001) with viral co-infection as compared to other age groups (I2 for subgroup analysis 64%, p = 0.04). CONCLUSIONS: No differences in clinical disease severity between viral co-infections and single respiratory infections were documented. The suggested increased risk of mortality observed amongst children with viral co-infections requires further investigation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives To prospectively assess respiratory health in wastewater workers and garbage collectors over 5 years. Methods Exposure, respiratory symptoms and conditions, spirometry and lung-specific proteins were assessed yearly in a cohort of 304 controls, 247 wastewater workers and 52 garbage collectors. Results were analysed with random coefficient models and linear regression taking into account several potential confounders. Results Symptoms, spirometry and lung-specific proteins were not affected by occupational exposure. Conclusions In this population no effects of occupational exposure to bioaerosols were found, probably because of good working conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Odor detection and discrimination by olfactory systems in vertebrates and invertebrates depend both on the selective expression of individual olfactory receptor genes in subpopulations of olfactory sensory neurons, and on the targeting of the encoded proteins to the exposed, ciliated endings of sensory dendrites. Techniques to visualize the expression and localization of olfactory receptor gene products in vivo have been essential to reveal the molecular logic of peripheral odor coding and to permit investigation of the developmental and cellular neurobiology of this sensory system. Here, we describe methods for detection of olfactory receptor transcripts and proteins in the antennal olfactory organ of the fruit fly, Drosophila melanogaster, an important genetic model organism. We include protocols both for antennal cryosections and whole-mount antennae. These methods can be adapted for detection of receptor expression in other olfactory and gustatory tissues in Drosophila, as well as in the chemosensory systems of other insects.