900 resultados para Repertory grid
Resumo:
Power system policies are broadly on track to escalate the use of renewable energy resources in electric power generation. Integration of dispersed generation to the utility network not only intensifies the benefits of renewable generation but also introduces further advantages such as power quality enhancement and freedom of power generation for the consumers. However, issues arise from the integration of distributed generators to the existing utility grid are as significant as its benefits. The issues are aggravated as the number of grid-connected distributed generators increases. Therefore, power quality demands become stricter to ensure a safe and proper advancement towards the emerging smart grid. In this regard, system protection is the area that is highly affected as the grid-connected distributed generation share in electricity generation increases. Islanding detection, amongst all protection issues, is the most important concern for a power system with high penetration of distributed sources. Islanding occurs when a portion of the distribution network which includes one or more distributed generation units and local loads is disconnected from the remaining portion of the grid. Upon formation of a power island, it remains energized due to the presence of one or more distributed sources. This thesis introduces a new islanding detection technique based on an enhanced multi-layer scheme that shows superior performance over the existing techniques. It provides improved solutions for safety and protection of power systems and distributed sources that are capable of operating in grid-connected mode. The proposed active method offers negligible non-detection zone. It is applicable to micro-grids with a number of distributed generation sources without sacrificing the dynamic response of the system. In addition, the information obtained from the proposed scheme allows for smooth transition to stand-alone operation if required. The proposed technique paves the path towards a comprehensive protection solution for future power networks. The proposed method is converter-resident and all power conversion systems that are operating based on power electronics converters can benefit from this method. The theoretical analysis is presented, and extensive simulation results confirm the validity of the analytical work.
Resumo:
By-catch and discards are a common problem to all fisheries. Recent studies of the Portuguese crustacean-trawl fishery show that discards average 70% of the total catch. This situation poses a threat not only to the management of target and commercial fish by-catch species stocks, but also in terms of the ecosystem impact of the discarded species whose survival is generally low. Previous attempts to address this problem by using oblique separator mesh panels associated with square-mesh windows, or square-mesh windows alone, provided encouraging results, but these are unlikely to have commercial applicability at present. Therefore, we tested the efficiency of a modified Nordmore grid in excluding some of the most captured non-commercial by-catch species, such as the blue whiting, Micromesistius poutassou, and the boarfish, Capros aper, evaluating simultaneously the losses of the crustacean target species (rose shrimp, Parapenaeus longirostris, Norway lobster, Nephrops norvegicus and red shrimp, Aristeus antennatus) and commercially valuable fish by-catch. A total of 41 valid hauls were carried out during 2001, and 15 in 2002 on board the R/V "Noruega". Results from both years varied considerably, with higher by-catch exclusion rates, in weight, registered in the second survey (73-74 and 48-63% for blue whiting and boarfish, respectively). The corresponding percentage reduction for target species was 8-15% for the Norway lobster, 4-9% for rose shrimp and 7-10% for red shrimp. The level of exclusion of the non-commercial by-catch is encouraging, although short-term loss of Norway lobster, where the escapees comprised larger individuals, raises some concern with regards to fishers' acceptance of mandatory use of grids. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
This paper focuses on tests of photovoltaic systems in order to address two case studies with silicon monocrystalline and silicon polycrystalline panels, respectively. The first case is an identification of the three parameters of the single-diode equivalent circuit for modelling photovoltaic systems with conclusion about the inevitably age degradation. A comparison between experimental observed and computed I-V and V-P characteristics curves is carried out at standard test conditions. The second case is an experimental observation on a photovoltaic system connected to an electric grid in what regards the quality of the energy injected into the grid. A measuring of the harmonic content in the voltage and in the current waveforms at the terminals of the photovoltaic system is carried out in order to conclude about the conformity with the Standard EN 50160 and the IEEE 519-1992, respectively.
Resumo:
This paper focuses on technology state of the art for the charge/discharge of electric energy storage supported by vanadium redox flow battery linked to the electric grid. Properties of vanadium, the main configuration and the reaction of charge/discharge of a vanadium redox flow battery are addressed. The vanadium redox flow battery has the highest cell voltage among the other redox flow battery, implying higher power and energy density which favours application at power plants. This electric energy storage is viewed as a promising contribution to be integrated in power system due to a reasonably bulky size and to successful applications currently allowing storage of energy at power plants or at electrical grids. For instances, allowing storage of energy as an economic improvement providing spin reserve to avoid penalty for imbalances between the energy delivered and energy contracted at closing of electricity market or as an economic improvement to diminish the cost of electricity usage of a consumer. The vanadium redox flow battery has the advantages of scalability customized to meet requirements for power and energy capacity and of excellent combination of energy efficiency, capital cost and life cycle costs compared with other technology.
Resumo:
This paper is on modeling and simulation for an offshore wind system equipped with a semi-submersible floating platform, a wind turbine, a permanent magnet synchronous generator, a multiple point clamped four level or five level full-power converter, a submarine cable and a second order filter. The drive train is modeled by three mass model considering the resistant stiffness torque, structure and tower in deep water due to the moving surface elevation. The system control uses PWM by space vector modulation associated with sliding mode and proportional integral controllers. The electric energy is injected into the electric grid either by an alternated current link or by a direct current link. The model is intend to be a useful tool for unveil the behavior and performance of the offshore wind system, especially for the multiple point clamped full-power converter, under normal operation or under malfunctions.
Resumo:
The Smart Grid needs a large amount of information to be operated and day by day new information is required to improve the operation performance. It is also fundamental that the available information is reliable and accurate. Therefore, the role of metrology is crucial, especially if applied to the distribution grid monitoring and the electrical assets diagnostics. This dissertation aims at better understanding the sensors and the instrumentation employed by the power system operators in the above-mentioned applications and studying new solutions. Concerning the research on the measurement applied to the electrical asset diagnostics: an innovative drone-based measurement system is proposed for monitoring medium voltage surge arresters. This system is described, and its metrological characterization is presented. On the other hand, the research regarding the measurements applied to the grid monitoring consists of three parts. The first part concerns the metrological characterization of the electronic energy meters’ operation under off-nominal power conditions. Original test procedures have been designed for both frequency and harmonic distortion as influence quantities, aiming at defining realistic scenarios. The second part deals with medium voltage inductive current transformers. An in-depth investigation on their accuracy behavior in presence of harmonic distortion is carried out by applying realistic current waveforms. The accuracy has been evaluated by means of the composite error index and its approximated version. Based on the same test setup, a closed-form expression for the measured current total harmonic distortion uncertainty estimation has been experimentally validated. The metrological characterization of a virtual phasor measurement unit is the subject of the third and last part: first, a calibrator has been designed and the uncertainty associated with its steady-state reference phasor has been evaluated; then this calibrator acted as a reference, and it has been used to characterize the phasor measurement unit implemented within a real-time simulator.
Resumo:
The way we live has revealed a lot about the choices made in the last decades. These choices are mostly based on a predatory socioeconomic structure, based on the pillars of anthropocentrism and inconsistent with the principles of global sustainability. This structure based on fossil fuels degrades the environment and directly and indirectly impacts the biomes. According to The International Energy Agency (2020), the sector was responsible for more than a third of global energy consumption and 40% of total GHG emissions into the atmosphere (directly and indirectly). This thesis presents the main effects of climate change observed in the built environment and at the urban territorial scale, through a review of the state of the art of the subject in the last decade (2010-2021). The thesis breaks down the projectual process seeking to identify how the architect and urban planner can mitigate the effects of climate change, adapting existing structures or in projects, and also promoting the expansion of the resilience of these building systems.
Resumo:
The coastal ocean is a complex environment with extremely dynamic processes that require a high-resolution and cross-scale modeling approach in which all hydrodynamic fields and scales are considered integral parts of the overall system. In the last decade, unstructured-grid models have been used to advance in seamless modeling between scales. On the other hand, the data assimilation methodologies to improve the unstructured-grid models in the coastal seas have been developed only recently and need significant advancements. Here, we link the unstructured-grid ocean modeling to the variational data assimilation methods. In particular, we show results from the modeling system SANIFS based on SHYFEM fully-baroclinic unstructured-grid model interfaced with OceanVar, a state-of-art variational data assimilation scheme adopted for several systems based on a structured grid. OceanVar implements a 3DVar DA scheme. The combination of three linear operators models the background error covariance matrix. The vertical part is represented using multivariate EOFs for temperature, salinity, and sea level anomaly. The horizontal part is assumed to be Gaussian isotropic and is modeled using a first-order recursive filter algorithm designed for structured and regular grids. Here we introduced a novel recursive filter algorithm for unstructured grids. A local hydrostatic adjustment scheme models the rapidly evolving part of the background error covariance. We designed two data assimilation experiments using SANIFS implementation interfaced with OceanVar over the period 2017-2018, one with only temperature and salinity assimilation by Argo profiles and the second also including sea level anomaly. The results showed a successful implementation of the approach and the added value of the assimilation for the active tracer fields. While looking at the broad basin, no significant improvements are highlighted for the sea level, requiring future investigations. Furthermore, a Machine Learning methodology based on an LSTM network has been used to predict the model SST increments.
Resumo:
L'elaborato descrive l'esperienza di tirocinio svolta nell'azienda Vertiv, dove è stato chiesto di realizzare un simulatore per il calcolo della degradazione delle batterie nella partecipazione al Grid Support. Nella prima parte viene illustrato il panorama energetico attuale, descrivendo il funzionamento generale di un sistema elettrico. Successivamente vengono descritti i gruppi di continuità e le loro modalità di funzionamento. A questo si collega la descrizione dei prodotti dell'azienda che verranno considerati nel simulatore. Vengono descritti i servizi di Grid Support che un cliente può scegliere al fine di ottenere un uso ottimale dell'energia elettrica, e quindi un risparmio, e quelli che aiutano la rete a bilanciare le variazioni di frequenza. Vi è inoltre una descrizione delle batterie, le loro caratteristiche e i parametri fondamentali di questa modalità di immagazzinamento dell'energia. Vengono riportate le principali tipologie delle batterie al Litio, essendo queste quelle utilizzate all'interno del simulatore. L'ultimo capitolo riguarda la descrizione del simulatore; vengono riportate le caratteristiche delle batterie considerate, divise a seconda del fornitore. Il simulatore è diviso in due parti, una chiamata "Frequency Regulation", l'altra "Peak Shaving". Nella prima vengono mostrati i dati di input che possono essere cambiati, la degradazione delle batterie collegata ai servizi FFR e FCR-D, i possibili guadagni che un cliente potrebbe ottenere nel momento in cui firma un contratto per partecipare ad un programma di variazione della frequenza, a seconda del mercato elettrico scelto. Nella seconda i dati di input, la degradazione delle batterie e i possibili risparmi associati al servizio Peak Shaving. Infine vengono riportati degli scenari di esempio per mostrare come un ipotetico cliente possa giocare con i dati di input e confrontare i risultati ottenuti allo scopo di ottenere la miglior soluzione possibile.
Resumo:
The idea of Grid Computing originated in the nineties and found its concrete applications in contexts like the SETI@home project where a lot of computers (offered by volunteers) cooperated, performing distributed computations, inside the Grid environment analyzing radio signals trying to find extraterrestrial life. The Grid was composed of traditional personal computers but, with the emergence of the first mobile devices like Personal Digital Assistants (PDAs), researchers started theorizing the inclusion of mobile devices into Grid Computing; although impressive theoretical work was done, the idea was discarded due to the limitations (mainly technological) of mobile devices available at the time. Decades have passed, and now mobile devices are extremely more performant and numerous than before, leaving a great amount of resources available on mobile devices, such as smartphones and tablets, untapped. Here we propose a solution for performing distributed computations over a Grid Computing environment that utilizes both desktop and mobile devices, exploiting the resources from day-to-day mobile users that alternatively would end up unused. The work starts with an introduction on what Grid Computing is, the evolution of mobile devices, the idea of integrating such devices into the Grid and how to convince device owners to participate in the Grid. Then, the tone becomes more technical, starting with an explanation on how Grid Computing actually works, followed by the technical challenges of integrating mobile devices into the Grid. Next, the model, which constitutes the solution offered by this study, is explained, followed by a chapter regarding the realization of a prototype that proves the feasibility of distributed computations over a Grid composed by both mobile and desktop devices. To conclude future developments and ideas to improve this project are presented.
Resumo:
Chronic telogen effluvium (CTE), a poorly understood condition, can be confused with or may be a prodrome to female pattern hair loss (FPHL). The pathogenesis of both is related to follicle cycle shortening and possibly to blood supply changes. To analyze a number of histomorphometric and immunohistochemical findings through vascular endothelial growth factor (VEGF), Ki-67, and CD31 immunostaining in scalp biopsies of 20 patients with CTE, 17 patients with mild FPHL and 9 controls. Ki-67 index and VEGF optical density were analyzed at the follicular outer sheath using ImageJ software. CD31 microvessel density was assessed by a Chalkley grid. Significant follicle miniaturization and higher density of nonanagen follicles were found in FPHL, compared with patients with CTE and controls. Ki-67+ index correlated positively with FPHL histological features. The FPHL group showed the highest VEGF optical density, followed by the CTE and control groups. No differences were found in CD31 microvessel density between the three groups. Histomorphometric results establish CTE as a distinct disorder, separate from FPHL from its outset. Its pathogenic mechanisms are also distinct. These findings support the proposed mechanism of 'immediate telogen release' for CTE, leading to cycle synchronization. For FPHL, accelerated anagen follicular mitotic rates and, thus, higher Ki-67 and VEGF values, would leave less time for differentiation, resulting in hair miniaturization.
Resumo:
The objectives of this work was to estimate the number of soil subsamples considering the classical statistics and geostatistics and determine the spatial variability of soil fertility attributes of an Ultisol, with clay texture, in an area of regenerating natural vegetation in Alegre - ES. Soil samples were collected in a depth of 0.0-0.2 m, at the crossing points of a regular grid, comprising a total of 64 points located at 10 m-intervals. The area presented low fertility soil. Considering a variation of 5% around the mean in the classic statistics, it is necessary a larger number of samples in relation to geostatistics. All the chemical attributes showed moderate to high spatial dependence, except for the effective cation exchange capacity (CECe), which showed pure nugget effect. The spherical semivariogram model gave the best fit to the data. Isoline maps allowed visualizing the differentiated spatial distribution of the contents of soil chemical attributes.
Resumo:
One of the main referring subjects to the solar energy is how to compare it economically with other sources of energy, as much alternatives as with conventionals (like the electric grid). The purpose of this work was to develop a software which congregates the technical and economic main data to identify, through methods of microeconomic analysis, the commercial viability in the sizing of photovoltaic systems, besides considering the benefits proceeding from the proper energy generation. Considering the period of useful life of the components of the generation system of photovoltaic electricity, the costs of the energy proceeding from the conventional grid had been identified. For the comparison of the conventional sources, electric grid and diesel generation, three scenes of costs of photovoltaic panels and two for the factor of availability of diesel generation had been used. The results have shown that if the cost of the panels is low and the place of installation is more distant of the electric grid, the photovoltaic system becomes the best option.
Resumo:
This work was carried out with the objective of studying the spatial variability of the physical attributes of a Red-Yellow Ultisol under pasture and secondary vegetation in natural regeneration. Two areas were chosen in a hillside, with the soil sampling to the depth of 0-0.2 m, with the georeferenced points in a regular grid of 10x10 m, totalizing 64 points. In each point it was evaluated the total volume of porosity, macroporosity, microporosity, bulk density, soil penetration resistance and soil water content. The studied attributes in the pasture area present indicator of soil compaction for the animals' traffic, with moderate and strong structure of spatial dependence, except for the macroporosity and penetration resistance. In the area of secondary vegetation (VN) only the macroporosity does not present spatial dependence. The total volume of porosity and the bulk density present the same spatial standard in the area under pasture.
Resumo:
Relief influences soil texture variability, since it contributes to the time of exposition of the materials to weathering factors. Our work was carried out in the city of Gavião Peixoto (SP), with the objective of characterizing the spatial variability of texture of a dystrophic Red Latosol cultivated with citrus. The hillside was divided into three segments: top, stocking lean and inferior lean. Soil samples were collected in a grid with regular intervals of 50 m, at the depths of 0.0-0.2 m and 0.6-0.8 m, comprising a total of 332 points in an area of 83.5 ha. The data were submitted to descriptive and geostatistics analyses (semivariogram modeling and kriging maps). The spatial behavior of the texture of oxisols is directly related to the relief forms in this study, which controls the direction of surface and subsurface water flows. The concept of homogeneity of clay distribution in the Oxisol profile is a piece of information that can be adjusted by knowing the spatial pattern of this distribution in different relief forms.