622 resultados para Removable dentures


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents a simple, fast and low cost technique for fabrication new conventional dentures from the duplication of old prosthesis in use by the patient. Colorless acrylic resin was poured into the moulds obtained by duplication of prosthesis. With the replicas obtained a functional impressions using polyether should be performed and they are stabilized with occlusal registration in acrylic resin. The molds need to be castings and mounted on an semi-adjustable articulator. The artificial teeth are positioned with the assistance of a guide made condensation silicone to reproduce the positioning of the teeth of the old prosthesis and fixed with wax 7. After approval of the teeth on the trial in wax, without adjustment of the planes, the prosthesis may be processed in the laboratory. After occlusal adjustment in the articulator the same can be installed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Visto que indicadores de prognóstico são uma ferramenta importante para a seleção de pacientes a serem tratados com prótese total, este estudo investigou a influência da forma e da resiliência do rebordo alveolar mandibular sobre a retenção e estabilidade de próteses totais convencionais. Noventa e três pacientes desdentados portadores de próteses totais superior e inferior compuseram a amostra. Os dados foram coletados quanto a forma e resiliência do rebordo mandibular. As próteses foram avaliadas para a retenção e estabilidade utilizando-se uma ferramenta objetiva e reproduzível. As associações entre as características clínicas do rebordo alveolar mandibular e retenção e estabilidade das próteses foram analisados por meio dos testes qui-quadrado e exato de Fisher (α = 0.05). Observou-se associação significativa entre a forma do rebordo e a estabilidade da prótese (p <0,05), enquanto que a resiliência foi associada significativamente com a retenção (p <0,001). Baseando-se nos resultados, a resiliência e forma do rebordo mandibular influenciaram, respectivamente, a retenção e estabilidade de próteses totais convencionais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Buscar na literatura evidências científicas que suportem os benefícios da individualização da curva de compensação em prótese total, pela técnica do desgaste de Paterson, em relação à curva de compensação não individualizada. Metodologia: Realizou-se, em Dezembro de 2009, uma revisão sistemática da literatura nas bases de dados MEDLINE, LILACS e BBO com os termos “prótese total” e “oclusão”. Para abranger uma maior quantidade de dados, realizou-se uma busca manual através das referências dos artigos inicialmente selecionados. Resultados: Obteve-se 1273 referências na base dados MEDLINE, 64 na LILACS e 103 na BBO, num total de 1440 referências. Dessas, apenas 24 tratavam do assunto “curva de compensação”, as quais somaram-se mais 13 artigos selecionados manualmente. Conclusão: A partir dos resultados obtidos, conclui-se que não existem dados suficientes que comprovem clinicamente os benefícios da individualização da curva de compensação em relação às próteses totais com curva de compensação não individualizada. Ensaios clínicos controlados e randomizados são necessários para que se possa determinar qual o procedimento mais adequado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Buscar na literatura evidências científicas que suportem os benefícios da individualização da curva de compensação em prótese total, pela técnica do desgaste de Paterson, em relação à curva de compensação não individualizada. Metodologia: Realizou-se, em Dezembro de 2009, uma revisão sistemática da literatura nas bases de dados MEDLINE, LILACS e BBO com os termos “prótese total” e “oclusão”. Para abranger uma maior quantidade de dados, realizou-se uma busca manual através das referências dos artigos inicialmente selecionados. Resultados: Obteve-se 1273 referências na base dados MEDLINE, 64 na LILACS e 103 na BBO, num total de 1440 referências. Dessas, apenas 24 tratavam do assunto “curva de compensação”, as quais somaram-se mais 13 artigos selecionados manualmente. Conclusão: A partir dos resultados obtidos, conclui-se que não existem dados suficientes que comprovem clinicamente os benefícios da individualização da curva de compensação em relação às próteses totais com curva de compensação não individualizada. Ensaios clínicos controlados e randomizados são necessários para que se possa determinar qual o procedimento mais adequado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The maintenance of masticatory function is especially important for patients wearing complete dentures due to their limitations. Thus, the bilateral balanced occlusal concept is used to achieve greater masticatory efficiency. However, a critical review of the literature reveals that there is not sufficient scientific evidence to support bilateral balanced occlusion as the most appropriate occlusal concept in complete dentures. Therefore, the aim of this study was to evaluate the masticatory efficiency in complete dentures wearers with bilateral balanced occlusion and canine guidance. A double-blinded controlled crossover clinical trial was conducted. The sample was composed by 24 edentulous patients who wore sets of complete dentures with both occlusal concepts during equal periods of 3 months. Objective data were collected through the masticatory efficiency test performed by the colorimetric method with the beads, in which capsules of a synthetic material enclosing fuchsine-containing granules were used. Subjective data were recorded by patient's ratings of their chewing function. No significant statistical difference was found for masticatory efficiency (p=0.095) between the two occlusal concepts studied. The results suggest that bilateral balanced occlusion does not improve the masticatory efficiency in complete denture wearers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The maintenance of masticatory function is especially important for patients wearing complete dentures due to their limitations. Thus, the bilateral balanced occlusal concept is used to achieve greater masticatory efficiency. However, a critical review of the literature reveals that there is not sufficient scientific evidence to support bilateral balanced occlusion as the most appropriate occlusal concept in complete dentures. Therefore, the aim of this study was to evaluate the masticatory efficiency in complete dentures wearers with bilateral balanced occlusion and canine guidance. A double-blinded controlled crossover clinical trial was conducted. The sample was composed by 24 edentulous patients who wore sets of complete dentures with both occlusal concepts during equal periods of 3 months. Objective data were collected through the masticatory efficiency test performed by the colorimetric method with the beads, in which capsules of a synthetic material enclosing fuchsine-containing granules were used. Subjective data were recorded by patient's ratings of their chewing function. No significant statistical difference was found for masticatory efficiency (p=0.095) between the two occlusal concepts studied. The results suggest that bilateral balanced occlusion does not improve the masticatory efficiency in complete denture wearers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gingiva, part of the masticatory mucosa tissue that covers the alveolar process and surrounds the cervical portion of teeth, has a definitive shape and texture associated with the eruption of teeth. Therefore, it must be included in rehabilitative planning, as the absence of papillae induces problems with esthetics, phonetics and food-impaction. The purpose of the present study was to approach the indications, limitations and techniques for making a removable artificial gingiva made of acrylic resin, by reporting on a clinical case. The patient, a 29-year-old woman, with the sequelae of periodontal disease, presented loss of interdental papilla causing “black holes”. She was dissatisfied with the esthetic appearance of her teeth, and also complained of long teeth and air escaping when she spoke. As treatment, prosthetic reconstruction was proposed, by means of a removable artificial gingiva (gingival epithesis) to simulate the presence of interdental papillae, providing better esthetics and phonetics. Gingival epithesis is an easily made, inserted and hygienically cleaned appliance that provides a simple and safe alternative solution for cases in which surgical techniques are limited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gingiva, part of the masticatory mucosa tissue that covers the alveolar process and surrounds the cervical portion of teeth, has a definitive shape and texture associated with the eruption of teeth. Therefore, it must be included in rehabilitative planning, as the absence of papillae induces problems with esthetics, phonetics and food-impaction. The purpose of the present study was to approach the indications, limitations and techniques for making a removable artificial gingiva made of acrylic resin, by reporting on a clinical case. The patient, a 29-year-old woman, with the sequelae of periodontal disease, presented loss of interdental papilla causing “black holes”. She was dissatisfied with the esthetic appearance of her teeth, and also complained of long teeth and air escaping when she spoke. As treatment, prosthetic reconstruction was proposed, by means of a removable artificial gingiva (gingival epithesis) to simulate the presence of interdental papillae, providing better esthetics and phonetics. Gingival epithesis is an easily made, inserted and hygienically cleaned appliance that provides a simple and safe alternative solution for cases in which surgical techniques are limited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to properties such as excellent biocompatibility, high resistance to corrosion and low specific weight, titanium has been considered a material of great interest for Dentistry. It has been widely used in implants and orthognathic surgeries. Recently, titanium has been seen as a feasible alternative for the fabrication of removable partial denture frameworks, either in pure titanium (99.75%) or in titanium alloy forms (Ti-6Al-4V; Ti-6A1-7Nb). Based on a review of the literature, this work studied the use of titanium for the fabrication of removable partial denture frameworks, focusing on its advantages and disadvantages as well as its characteristics. It was concluded that the use of titanium is a convenient option for partially edentulous arches rehabilitation with quite satisfactory and promising clinical results. However, the need for highly-equipped laboratories increases the cost, preventing its large scale use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to properties such as excellent biocompatibility, high resistance to corrosion and low specific weight, titanium has been considered a material of great interest for Dentistry. It has been widely used in implants and orthognathic surgeries. Recently, titanium has been seen as a feasible alternative for the fabrication of removable partial denture frameworks, either in pure titanium (99.75%) or in titanium alloy forms (Ti-6Al-4V; Ti-6A1-7Nb). Based on a review of the literature, this work studied the use of titanium for the fabrication of removable partial denture frameworks, focusing on its advantages and disadvantages as well as its characteristics. It was concluded that the use of titanium is a convenient option for partially edentulous arches rehabilitation with quite satisfactory and promising clinical results. However, the need for highly-equipped laboratories increases the cost, preventing its large scale use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: A number of methods have been described for the fabrication of complete dentures. There are 2 common ways to make conventional complete dentures: a traditional method and a simplified method. PURPOSE: The purpose of this study was to conduct a systematic review to compare the efficiency of simplified and traditional methods for the fabrication of complete dentures. MATERIAL AND METHODS: The review was conducted by 3 independent reviewers and included articles published up to December 2013. Three electronic databases were searched: MEDLINE-PubMed, The Cochrane Library, and ISI Web of Science. A manual search also was performed to identify clinical trials of simplified versus traditional fabrication of complete dentures. RESULTS: Six articles were classified as randomized controlled clinical trials and were included in this review. The majority of the selected articles analyzed general satisfaction, denture stability, chewing ability and function, comfort, hygiene, esthetics, speech function, quality of life, cost, and fabrication time. CONCLUSIONS: Although the studies reviewed demonstrate some advantages of simplified over traditional prostheses, such as lower cost and clinical time, good chewing efficiency, and a positive effect on the quality of life, the reports related the use of different simplified methods for the fabrication of complete dentures. Additional randomized controlled trials that used similar simplified techniques for the fabrication of complete dentures should be performed with larger sample sizes and longer follow-up periods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditional methods for dentures fabrication require a wide clinical and laboratory procedures; however, there is no scientific evidence that these methods can produce better results when compared with simplified methods. Aim: To evaluate the effectiveness of a simplified methods for denture fabrication, comparing it to the traditional one through masticatory efficiency and prosthesis quality. Method: A randomized controlled trial was conducted with 50 patients, 25 rehabilitated with prosthesis produced by traditional technique and 25 rehabilitated by a simplified technique. The masticatory efficiency was evaluated by colorimetric method, using chewing capsules. The quality of prosthesis was obtained using a reliable and reproducible instrument. Statistical analysis of the masticatory efficiency and quality of the prosthesis was obtained by the Mann-Whitney test. Results: 39 patients completed the study, 18 on traditional group and 21 on simplified group. There was no difference between groups for the masticatory efficiency (p = 0.835) and the quality of the prosthesis (p = 0672). The evaluation of the overall quality of the prosthesis according to oral conditions, demonstrated significant difference on the height of the mandibular ridges (p = 0.010) and mandibular muscle attachments (p = 0.039). Conclusion: Complete dentures fabricated by simplified method were considered effective from the point of view of masticatory efficiency and quality of prosthetics, with results similar to those made by the traditional method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditional methods for dentures fabrication require a wide clinical and laboratory procedures; however, there is no scientific evidence that these methods can produce better results when compared with simplified methods. Aim: To evaluate the effectiveness of a simplified methods for denture fabrication, comparing it to the traditional one through masticatory efficiency and prosthesis quality. Method: A randomized controlled trial was conducted with 50 patients, 25 rehabilitated with prosthesis produced by traditional technique and 25 rehabilitated by a simplified technique. The masticatory efficiency was evaluated by colorimetric method, using chewing capsules. The quality of prosthesis was obtained using a reliable and reproducible instrument. Statistical analysis of the masticatory efficiency and quality of the prosthesis was obtained by the Mann-Whitney test. Results: 39 patients completed the study, 18 on traditional group and 21 on simplified group. There was no difference between groups for the masticatory efficiency (p = 0.835) and the quality of the prosthesis (p = 0672). The evaluation of the overall quality of the prosthesis according to oral conditions, demonstrated significant difference on the height of the mandibular ridges (p = 0.010) and mandibular muscle attachments (p = 0.039). Conclusion: Complete dentures fabricated by simplified method were considered effective from the point of view of masticatory efficiency and quality of prosthetics, with results similar to those made by the traditional method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A recently developed novel biomass fuel pellet, the Q’ Pellet, offers significant improvements over conventional white pellets, with characteristics comparable to those of coal. The Q’ Pellet was initially created at bench scale using a proprietary die and punch design, in which the biomass was torrefied in-situ¬ and then compressed. To bring the benefits of the Q’ Pellet to a commercial level, it must be capable of being produced in a continuous process at a competitive cost. A prototype machine was previously constructed in a first effort to assess continuous processing of the Q’ Pellet. The prototype torrefied biomass in a separate, ex-situ reactor and transported it into a rotary compression stage. Upon evaluation, parts of the prototype were found to be unsuccessful and required a redesign of the material transport method as well as the compression mechanism. A process was developed in which material was torrefied ex-situ and extruded in a pre-compression stage. The extruded biomass overcame multiple handling issues that had been experienced with un-densified biomass, facilitating efficient material transport. Biomass was extruded directly into a novel re-designed pelletizing die, which incorporated a removable cap, ejection pin and a die spring to accommodate a repeatable continuous process. Although after several uses the die required manual intervention due to minor design and manufacturing quality limitations, the system clearly demonstrated the capability of producing the Q’ Pellet in a continuous process. Q’ Pellets produced by the pre-compression method and pelletized in the re-designed die had an average dry basis gross calorific value of 22.04 MJ/kg, pellet durability index of 99.86% and dried to 6.2% of its initial mass following 24 hours submerged in water. This compares well with literature results of 21.29 MJ/kg, 100% pellet durability index and <5% mass increase in a water submersion test. These results indicate that the methods developed herein are capable of producing Q’ Pellets in a continuous process with fuel properties competitive with coal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents details of the design and development of novel tools and instruments for scanning tunneling microscopy (STM), and may be considered as a repository for several years' worth of development work. The author presents design goals and implementations for two microscopes. First, a novel Pan-type STM was built that could be operated in an ambient environment as a liquid-phase STM. Unique features of this microscope include a unibody frame, for increased microscope rigidity, a novel slider component with large Z-range, a unique wiring scheme and damping mechanism, and a removable liquid cell. The microscope exhibits a high level of mechanical isolation at the tunnel junction, and operates excellently as an ambient tool. Experiments in liquid are on-going. Simultaneously, the author worked on designs for a novel low temperature, ultra-high vacuum (LT-UHV) instrument, and these are presented as well. A novel stick-slip vertical coarse approach motor was designed and built. To gauge the performance of the motor, an in situ motion sensing apparatus was implemented, which could measure the step size of the motor to high precision. A new driving circuit for stick-slip inertial motors is also presented, that o ffers improved performance over our previous driving circuit, at a fraction of the cost. The circuit was shown to increase step size performance by 25%. Finally, a horizontal sample stage was implemented in this microscope. The build of this UHV instrument is currently being fi nalized. In conjunction with the above design projects, the author was involved in a collaborative project characterizing N-heterocyclic carbene (NHC) self-assembled monolayers (SAMs) on Au(111) films. STM was used to characterize Au substrate quality, for both commercial substrates and those manufactured via a unique atomic layer deposition (ALD) process by collaborators. Ambient and UHV STM was then also used to characterize the NHC/Au(111) films themselves, and several key properties of these films are discussed. During this study, the author discovered an unexpected surface contaminant, and details of this are also presented. Finally, two models are presented for the nature of the NHC-Au(111) surface interaction based on the observed film properties, and some preliminary theoretical work by collaborators is presented.