989 resultados para Radionuclide Angiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prenatal heart valve interventions aiming at the early and systematic correction of congenital cardiac malformations represent a promising treatment option in maternal-fetal care. However, definite fetal valve replacements require growing implants adaptive to fetal and postnatal development. The presented study investigates the fetal implantation of prenatally engineered living autologous cell-based heart valves. Autologous amniotic fluid cells (AFCs) were isolated from pregnant sheep between 122 and 128 days of gestation via transuterine sonographic sampling. Stented trileaflet heart valves were fabricated from biodegradable PGA-P4HB composite matrices (n = 9) and seeded with AFCs in vitro. Within the same intervention, tissue engineered heart valves (TEHVs) and unseeded controls were implanted orthotopically into the pulmonary position using an in-utero closed-heart hybrid approach. The transapical valve deployments were successful in all animals with acute survival of 77.8% of fetuses. TEHV in-vivo functionality was assessed using echocardiography as well as angiography. Fetuses were harvested up to 1 week after implantation representing a birth-relevant gestational age. TEHVs showed in vivo functionality with intact valvular integrity and absence of thrombus formation. The presented approach may serve as an experimental basis for future human prenatal cardiac interventions using fully biodegradable autologous cell-based living materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Myocardial infarction is rare in children, if it occurs, findings are almost similar to adults. In Ouchenne muscular dystrophy (OMO), ST segment displacement associated with typical chest pain can occur. We report the case of a young boy with OMO presenting symptoms suggestive of myocardial ischemia. Case report: 7 year old boy, diagnosed with OMO, eoming to the emergency department with complaints of acute chest pain, dyspnoea and anxiety the night before. Clinical examination was not remarkable, with exception of findings of the OMO. ECG showed important ST-segment elevation in right precordial leads. Major increase in troponin 1 42.33 mcg/(normal, <0.04 mcg/I) was found. Echocardiography revealed slight yskinesia of postero-septal wall without decrease in ventricular function. As acute pain had happened more han 12 hours before referral and as the child was asymptomatic, he received anti-platelets therapy. The serum level of troponin 1 declined and the ECG normalised in a few days. Cardiac catheterization did not show any coronary anomaly or eardiac dysfunction. Cardiac biopsy revealed myocardial cell damaged compatible with OMO cardiomyopathy. Tc99m myocardial single-photon emission computed tomography (SPECT) did not show any radionuclide uptake defect. Conclusions: ln this particular context of children with OMO, the classical signs of myocardial ischemia could be misleading, standard investigation failed to demonstrate the cause of chest pain and inerease of troponin l, there was also no evidence of myocarditis. Role of late enhancement (LE) signal in eontrast-enhanced MRI in the understanding of the occurring process has to be evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies in adults have shown that late gadolinium enhanced cardiac magnetic resonance is a safe and noninvasive diagnostic tool which allows one to differentiate myocardial infarction from myocarditis. We believe that it may also be highly useful in the paediatric population for the same purpose.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The neuropsychological records of 56 patients operated for clipping were studied. Almost every patient remained autonomous and without invalidating motor defect. The present study was aimed at specifying the type and frequency of neuropsychological sequelae and, to a lesser extent, the role of various pathophysiological factors. A main concern was to examine to what extent and at what post-operative interval the neuropsychological assessment can predict the intellectual and socioprofessional outcome of each individual patient. The neuropsychological assessment performed beyond the acute phase showed evidence of intellectual sequelae in about two thirds of the patients. Only one case of permanent anterograde amnesia was observed, probably due to unavoidable inclusion of a hypothalamic artery in the clip during surgery. Transient anterograde amnesia and confabulations were occasionally observed, generally for less than three weeks. A common finding was impaired performance on memory and/or executive tests. In a minority of patients, language disorders, visuoperceptive and visuoconstructive disabilities were found, probably in relation with hemodynamic changes at distance from the aneurysm. Global impairment of intellectual function was not uncommon in the acute post-operative phase but it evolved in most cases towards a more selective impairment, for instance restricted to executive and memory functions, in the chronic phase. The neuropsychological investigation carried out 4 to 15 weeks post-operatively provided satisfactory information about possible long-lasting intellectual disturbances and professional resumption. In particular, persistent global intellectual impairment, persistent amnesia and confabulations 4-15 weeks post-operative were associated with cessation of professional activity; executive and memory impairment, behavioral disturbances such as those encountered in patients with frontal lobe damage were associated with a decreased probability of full-time employment. Pre- and post-operative angiography were not good predictors of long-term cognitive outcome: normal angiography was not necessarily followed by normal neuropsychological outcome, conversely abnormal angiography could be found together with normal neuropsychological outcome. By contrast, there was a relationship between left-lateralised abnormalities on post-operative angiography and occurrence of language disorders; similarly, there was a relationship between side of craniotomy and type of deficits, that is language disorders versus visuoperceptive-visuoconstructive impairments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report a case with anterior and posterior nodules associated with systemic sarcoidosis. METHODS: A patient with decreased vision underwent complete ophthalmologic examination, ultrasound biomicroscopy, fluorescein and indocyanine green (ICG) angiography. RESULTS: The patient presented a nodule of the iris of the OS and of the optic nerves of both eyes. Chest computed tomography and tissue biopsy established the diagnosis. CONCLUSIONS: Fluorescein and ICG angiography are the only objective exams to demonstrate the extent of ocular involvement in a patient with sarcoidosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Navigator-gated and corrected 3D coronary MR angiography (MRA) allows submillimeter image acquisition during free breathing. However, cranial diaphragmatic drift and relative phase shifts of chest-wall motion are limiting factors for image quality and scanning duration. We hypothesized that image acquisition in the prone position would minimize artifacts related to chest-wall motion and suppress diaphragmatic drift. Twelve patients with radiographically-confirmed coronary artery disease and six healthy adult volunteers were studied in both the prone and the supine position during free-breathing navigator-gated and corrected 3D coronary MRA. Image quality and the diaphragmatic positions were objectively compared. In the prone position, there was a 36% improvement in signal-to-noise ratio (SNR; 15.5 +/- 2.7 vs. 11.4 +/- 2.6; P < 0.01) and a 34% improvement in CNR (12.5 +/- 3.3 vs. 9.3 +/- 2.5, P < 0.01). The prone position also resulted in a 17% improvement in coronary vessel definition (P < 0.01). Cranial end-expiratory diaphragmatic drift occurred less frequently in the prone position (23% +/- 17% vs. 40% +/- 26% supine; P <0.05), and navigator efficiency was higher. Prone coronary MRA results in improved SNR and CNR with enhanced coronary vessel definition. Cranial end-expiratory diaphragmatic drift also was reduced, and navigator efficiency was enhanced. When feasible, prone imaging is recommended for free-breathing coronary MRA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Cx40 is a gap junction protein important for cell-cell communication in the endothelium. Polymorphisms in the promoter region of the human Cx40 gene, -44G>A and +71A>G, were shown to reduce Cx40 transcription by half. As mice with an endothelial-specific deletion of Cx40 are more susceptible to atherosclerosis, this study was designed to discover a correlation between these polymorphisms and atherosclerosis in European populations.¦METHODS AND RESULTS: 803 patients referred to the Geneva University Hospitals for elective coronary angiography were divided according to the number of significantly stenosed vessels (from 0 to 3) and were genotyped for the Cx40 polymorphisms. Genotype distribution in the control group was -44GG/+71AA=59.8%, -44AG/+71AG=35.1% and -44AA/+71GG=5.2%. Surprisingly, this distribution was similar in the CAD group, with -44GG/+71AA=58.5%, -44AG/+71AG=37.6% and -44AA/+71GG=3.8% (p=0.67). Moreover, no significant association between histological carotid plaque composition of culprit lesions and Cx40 polymorphisms could be detected in 583 Dutch patients of the Athero-Express study.¦CONCLUSIONS: Despite a clear antiatherogenic role of Cx40 in mice, our study could not detect an association of Cx40 promoter polymorphisms and CAD in human. Moreover, a correlation with atherosclerotic plaque stability or hypertension could not be demonstrated either. Connexin polymorphisms affecting channel function may be of greater importance for cardiovascular disease than polymorphisms affecting the expression level of the protein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To compare autofluorescence (AF) images obtained with the confocal scanning laser ophthalmoscope (using the Heidelberg retina angiograph; HRA) and the modified Topcon fundus camera, in a routine clinical setting. A prospective comparative study conducted at the Jules-Gonin Eye Hospital. Fifty-six patients from the medical retina clinic. All patients had complete ophthalmic slit-lamp and fundus examinations, colour and red-free fundus photography, AF imaging with both instruments, and fluorescein angiography. Cataract and fixation were graded clinically. AF patterns were analyzed for healthy and pathological features. Differences of image noise were analyzed by cataract grading and fixation. A total of 105 eyes were included. AF patterns discovered by the retina angiograph and the fundus camera images, respectively, were a dark optic disc in 72 % versus 15 %, a dark fovea in 92 % versus 4 %, sub- and intraretinal fluid visible as hyperautofluorescence on HRA images only, lipid exudates visible as hypoautofluorescence on HRA images only. The same autofluorescent pattern was found on both images for geographic atrophy, retinal pigment changes, drusen and haemorrhage. Image noise was significantly associated with the degree of cataract and/or poor fixation, favouring the fundus camera. Images acquired by the fundus camera before and after fluorescein angiography were identical. Fundus AF images differ according to the technical differences of the instruments used. Knowledge of these differences is important not only for correctly interpreting images, but also for selecting the most appropriate instrument for the clinical situation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the occurrence of macular edema (ME) after epiretinal membrane resection, managed either with simple vitrectomy or with combined vitrectomy and phacoemulsification. MATERIAL AND METHODS: Two groups of 12 patients had a vitrectomy for epiretinal membrane associated or not to a phacoemulsification. A fundus fluorescein angiography was performed pre and postoperatively and at least 3 months after the surgery. RESULTS: In the group of patients who had a simple vitrectomy, a ME was observed in 50% of the cases preoperatively and in 25% of the cases at the end of follow-up. In 3 cases, preoperative ME was worsened after the surgery. In the group of patients who were treated by a combined vitrectomy and phacoemulsification, a ME was observed in 25% of the cases preoperatively and in 50% of the cases at the end of follow-up. A de novo ME was observed in 3 cases. CONCLUSION: Combined vitrectomy and cataract surgery could allow a rapid recovery of visual acuity but might increase the occurrence of ME.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High-dose dobutamine magnetic resonance stress testing has been shown to be superior to dobutamine stress echocardiography for diagnosis of coronary artery disease (CAD). We determined the feasibility of quantitative myocardial tagging during low- and high-dose dobutamine stress and tested the ability of global systolic and diastolic quantitative parameters to identify patients with significant CAD. Twenty-five patients suspected of having significant CAD were examined with a standard high-dose dobutamine/atropine stress magnetic resonance protocol (1.5-T scanner, Philips). All patients underwent invasive coronary angiography as the standard of reference for the presence (n = 13) or absence (n = 12) of significant CAD. During low-dose dobutamine stress, systolic (circumferential shortening, systolic rotation, and systolic rotation velocity) and diastolic (velocity of circumferential lengthening and diastolic rotation velocity) parameters changed significantly in patients without CAD (all P < 0.05 vs. rest) but not in patients with CAD. Identification of patients without and with CAD during low-dose stress was possible using the diastolic parameter of "time to peak untwist." At high-dose stress, none of the global systolic or diastolic parameters showed the potential to identify the presence of significant CAD. With myocardial tagging, a quantitative analysis of systolic and diastolic function was feasible during low- and high-dose dobutamine stress. In our study, the diastolic parameter of time to peak untwist as assessed during low-dose dobutamine stress was the most promising global parameter for identification of patients with significant CAD. Thus quantitative myocardial tagging may become a tool that reduces the need for high-dose dobutamine stress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This randomized study compares the coronary perfusion rate in patients with acute myocardial infarction (AMI) treated with 2 different intravenous thrombolytic agents: streptokinase 1.5 million U given over 60 minutes and anisoylated human plasminogen streptokinase activator complex (anistreplase) administrated as a bolus of 30 U over 5 minutes. One hundred seventy-five patients (149 men and 26 women, mean age 54 years) have been included in this study. Eighty-nine patients were treated with anistreplase and 86 patients with streptokinase. AMI was inferior in 54 patients (61%) in the anistreplase group and in 54 patients (63%) in the streptokinase group. It was anterior in 35 (40%) and 32 (37%) patients, respectively. Coronary angiography and ventriculography were performed at a mean time (+/- SEM) of 207 +/- 11 minutes after the beginning of thrombolysis in 170 patients. A perfusion score grade of 2 or 3 according to the Thrombolysis in Myocardial Infarction trial was found in 63 patients (72%) in the anistreplase group and in 56 patients (68%) in the streptokinase group (p = NS). Severe bleeding occurred in 7 patients (8%) after anistreplase and in 6 patients (7%) after streptokinase. No cerebral hemorrhage occurred. Nine patients (5%) died during their hospital stay: 6 after anistreplase and 3 after streptokinase. It is concluded that intravenous administration of anistreplase or streptokinase is efficient and safe. Coronary patency 207 minutes after fibrinolysis, incidence of adverse events and mortality are similar in both groups.