996 resultados para Pulmonary delivery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulmonary embolism (PE) is traditionally treated in hospital. Growing evidence from non randomized prospective studies suggests that a substantial proportion of patients with non-massive PE might be safely treated in the outpatient setting using low molecular weight heparins. Based on this evidence, professional societies started to recommend outpatient care for selected patients with non-massive PE. Despite these recommendations, outpatient treatment of non-massive PE appears to be uncommon in clinical practice. The major barriers to PE outpatient care are, firstly, the uncertainty as how to identify low risk patients with PE who are candidates for outpatient care and secondly the lack of high quality evidence from randomized trials demonstrating the safety of PE outpatient care compared to traditional inpatient management. Also, although clinical prognostic models, echocardiography and cardiac biomarkers accurately identify low risk patients with PE in prospective studies, the benefit of risk stratification strategies based on these instruments should be demonstrated in prospective management studies and clinical trials before they can be implemented as decision aids to guide PE outpatient treatment. Before high quality evidence documenting the safety of an outpatient treatment approach is published, outpatient management of non-massive PE cannot be generally recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Assisted reproductive technology (ART) involves the manipulation of early embryos at a time when they may be particularly vulnerable to external disturbances. Environmental influences during the embryonic and fetal development influence the individual's susceptibility to cardiovascular disease, raising concerns about the potential consequences of ART on the long-term health of the offspring. METHODS AND RESULTS: We assessed systemic (flow-mediated dilation of the brachial artery, pulse-wave velocity, and carotid intima-media thickness) and pulmonary (pulmonary artery pressure at high altitude by Doppler echocardiography) vascular function in 65 healthy children born after ART and 57 control children. Flow-mediated dilation of the brachial artery was 25% smaller in ART than in control children (6.7±1.6% versus 8.6±1.7%; P<0.0001), whereas endothelium-independent vasodilation was similar in the 2 groups. Carotid-femoral pulse-wave velocity was significantly (P<0.001) faster and carotid intima-media thickness was significantly (P<0.0001) greater in children conceived by ART than in control children. The systolic pulmonary artery pressure at high altitude (3450 m) was 30% higher (P<0.001) in ART than in control children. Vascular function was normal in children conceived naturally during hormonal stimulation of ovulation and in siblings of ART children who were conceived naturally. CONCLUSIONS: Healthy children conceived by ART display generalized vascular dysfunction. This problem does not appear to be related to parental factors but to the ART procedure itself. CLINICAL TRIAL REGISTRATION: URL: www.clinicaltrials.gov. Unique identifier: NCT00837642.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-altitude pulmonary edema is a life-threatening condition occurring in predisposed but otherwise healthy individuals. It therefore permits the study of underlying mechanisms of pulmonary edema in the absence of confounding factors such as coexisting cardiovascular or pulmonary disease, and/or drug therapy. There is evidence that some degree of asymptomatic alveolar fluid accumulation may represent a normal phenomenon in healthy humans shortly after arrival at high altitude. Two fundamental mechanisms then determine whether this fluid accumulation is cleared or whether it progresses to HAPE: the quantity of liquid escaping from the pulmonary vasculature and the rate of its clearance by the alveolar respiratory epithelium. The former is directly related to the degree of hypoxia-induced pulmonary hypertension, whereas the latter is determined by the alveolar epithelial sodium transport. Here, we will review evidence that, in HAPE-prone subjects, impaired pulmonary endothelial and epithelial NO synthesis and/or bioavailability may represent a central underlying defect predisposing to exaggerated hypoxic pulmonary vasoconstriction and, in turn, capillary stress failure and alveolar fluid flooding. We will then demonstrate that exaggerated pulmonary hypertension, although possibly a conditio sine qua non, may not always be sufficient to induce HAPE and how defective alveolar fluid clearance may represent a second important pathogenic mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Invasive studies suggest that healthy children living at high altitude display pulmonary hypertension, but the data to support this assumption are sparse. Nitric oxide (NO) synthesized by the respiratory epithelium regulates pulmonary artery pressure, and its synthesis was reported to be increased in Aymara high-altitude dwellers. We hypothesized that pulmonary artery pressure will be lower in Aymara children than in children of European ancestry at high altitude, and that this will be related to increased respiratory NO. We therefore compared pulmonary artery pressure and exhaled NO (a marker of respiratory epithelial NO synthesis) between large groups of healthy children of Aymara (n = 200; mean +/- SD age, 9.5 +/- 3.6 years) and European ancestry (n = 77) living at high altitude (3,600 to 4,000 m). We also studied a group of European children (n = 29) living at low altitude. The systolic right ventricular to right atrial pressure gradient in the Aymara children was normal, even though significantly higher than the gradient measured in European children at low altitude (22.5 +/- 6.1 mm Hg vs 17.7 +/- 3.1 mm Hg, p < 0.001). In children of European ancestry studied at high altitude, the pressure gradient was 33% higher than in the Aymara children (30.0 +/- 5.3 mm Hg vs 22.5 +/- 6.1 mm Hg, p < 0.0001). In contrast to what was expected, exhaled NO tended to be lower in Aymara children than in European children living at the same altitude (12.4 +/- 8.8 parts per billion [ppb] vs 16.1 +/- 11.1 ppb, p = 0.06) and was not related to pulmonary artery pressure in either group. Aymara children are protected from hypoxic pulmonary hypertension at high altitude. This protection does not appear to be related to increased respiratory NO synthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resting energy expenditure is frequently increased in chronic obstructive pulmonary disease (COPD), but it is unknown if this hypermetabolism holds true over 24 h. The aim of this study was to measure the actual 24-h energy expenditure (24-h EE) in patients with stable COPD. Energy expenditure was measured by indirect calorimetry, using a metabolic chamber for 24-h EE and a canopy for basal metabolic rate (BMR). Physical activity was detected in the chamber by a radar system, and its duration was quantified. Two groups matched for age and height were studied: 16 male ambulatory patients with stable COPD and 12 male normal subjects. Body weight was 92 +/- 12% of ideal body weight in the group with COPD and 108 +/- 11% in the control group (p = 0.01). BMR was 120 +/- 7% of predicted in the group with COPD and 108 +/- 12% in the control group (p < 0.01). However, 24-h EE was similar in the two groups, amounting to 1,935 +/- 259 kcal in patients with COPD and 2,046 +/- 253 kcal in the control group (NS). This corresponded to 145% and 137% of predicted BMR, and to 121% and 126% of measured BMR in patients with COPD and the control group, respectively (NS). Patients were allowed to pursue their usual treatment within the chamber, and a positive correlation existed between 24-h EE and the daily dose of inhaled beta 2-agonists (p < 0.03). During daytime, physical activity was lower in patients with COPD. This study shows that patients with stable COPD are characterized by a normal daily energy expenditure in controlled conditions in spite of an increased basal metabolic rate. They appear to save energy by reducing their spontaneous level of physical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficacy of an antisense oligonucleotide (ODN17) cationic nanoemulsion directed at VEGF-R2 to reduce neovascularization was evaluated using rat corneal neovascularization and retinopathy of prematurity (ROP) mouse models. Application of saline solution or scrambled ODN17 solution on eyes of rats led to the highest extent of corneal neovascularization. The groups treated with blank nanoemulsion or scrambled ODN17 nanoemulsion showed moderate inhibition in corneal neovascularization with no significant difference with the saline and scrambled ODN17 control solution groups, while the groups treated with ODN17 solution or Avastin® (positive ODN17 control) clearly elicited marked significant inhibition in corneal neovascularization confirming the results reported in the literature. The highest significant corneal neovascularization inhibition efficiency was noted in the groups treated with ODN17 nanoemulsion (topical and subconjunctivally). However, in the ROP mouse model, the ODN17 in PBS induced a 34% inhibition of retinal neovascularization when compared to the aqueous-vehicle-injected eyes. A significantly higher inhibition of vitreal neovascularization (64%) was observed in the group of eyes treated with ODN17 nanoemulsion. No difference in extent of neovascularization was observed between blank nanoemulsion, scrambled ODN17 nanoemulsion, vehicle or non-treated eyes. The overall results indicate that cationic nanoemulsion can be considered a promising potential ocular delivery system and an effective therapeutic tool of high clinical significance in the prevention and forthcoming treatment of ocular neovascular diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Similar to human chronic lymphocytic leukemia (CLL), the de novo New Zealand Black (NZB) mouse model has a genetically determined age-associated increase in malignant B-1 clones and decreased expression of microRNAs miR-15a and miR-16 in B-1 cells. In the present study, lentiviral vectors were employed in vivo to restore miR-15a/16, and both the short-term single injection and long-term multiple injection effects of this delivery were observed in NZB. Control lentivirus without the mir-15a/16 sequence was used for comparison. We found that in vivo lentiviral delivery of mir-15a/16 increased miR-15a/16 expression in cells that were transduced (detected by GFP expression) and in sera when compared with control lentivirus treatment. More importantly, mice treated with the miR-expressing lentivirus had decreased disease. The lentivirus had little systemic toxicity while preferentially targeting B-1 cells. Short-term effects on B-1 cells were direct effects, and only malignant B-1 cells transduced with miR-15a/16 lentivirus had decreased viability. In contrast, long-term studies suggested both direct and indirect effects resulting from miR-15a/16 lentivirus treatment. A decrease in B-1 cells was found in both the transduced and non-transduced populations. Our data support the potential use of systemic lentiviral delivery of miR-15a/16 to ameliorate disease manifestations of CLL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. The hypermetabolism frequently observed at rest in patients with chronic obstructive pulmonary disease has been attributed to a high cost of breathing. However, measurement of the cost of breathing by the usual hyperventilation procedure is fraught with methodological problems. The purpose of this study was to measure more directly the cost of breathing in a group of ambulatory patients with stable chronic obstructive pulmonary disease. 2. The cost of breathing was calculated as the difference in oxygen consumption measured by indirect calorimetry between spontaneous breathing and noninvasive mechanical ventilation. Inspiratory muscle rest was achieved by negative or positive pressure ventilation and assessed by the recording of surface electromyograms of the diaphragm and parasternal intercostal muscles. 3. Seven tests were performed in six ambulatory patients with stable chronic obstructive pulmonary disease, four tests using positive pressure ventilation and three with negative pressure ventilation. During mechanical ventilation, the electromyographic activity of the diaphragm decreased by 70 +/- 22%, while that of the parasternals was suppressed in four tests, and remained unchanged in three. However, oxygen consumption was only 1.6 +/- 6.2% lower during mechanical ventilation. 4. The cost of breathing measured in this study was therefore much lower than previously published values. Stress was not likely to influence the results, as both the heart rate and plasma catecholamines did not change between spontaneous breathing and mechanical ventilation. These results suggest that the cost of breathing in ambulatory patients with stable chronic obstructive pulmonary disease may be lower than previously estimated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In haemodynamically stable patients with acute symptomatic pulmonary embolism (PE), studies have not evaluated the usefulness of combining the measurement of cardiac troponin, transthoracic echocardiogram (TTE), and lower extremity complete compression ultrasound (CCUS) testing for predicting the risk of PE-related death. Methods: The study assessed the ability of three diagnostic tests (cardiac troponin I (cTnI), echocardiogram, and CCUS) to prognosticate the primary outcome of PE-related mortality during 30 days of follow-up after a diagnosis of PE by objective testing. Results: Of 591 normotensive patients diagnosed with PE, the primary outcome occurred in 37 patients (6.3%; 95% CI 4.3% to 8.2%). Patients with right ventricular dysfunction (RVD) by TTE and concomitant deep vein thrombosis (DVT) by CCUS had a PE-related mortality of 19.6%, compared with 17.1% of patients with elevated cTnI and concomitant DVT and 15.2% of patients with elevated cTnI and RVD. The use of any two-test strategy had a higher specificity and positive predictive value compared with the use of any test by itself. A combined three-test strategy did not further improve prognostication. For a subgroup analysis of high-risk patients, according to the pulmonary embolism severity index (classes IV and V), positive predictive values of the two-test strategies for PE-related mortality were 25.0%, 24.4% and 20.7%, respectively. Conclusions: In haemodynamically stable patients with acute symptomatic PE, a combination of echocardiography (or troponin testing) and CCUS improved prognostication compared with the use of any test by itself for the identification of those at high risk of PE-related death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate the effect of structured physical exercise programs during pregnancy on the course of labor and delivery. STUDY DESIGN: We conducted a systematic review and metaanalysis using the following data sources: Medline and The Cochrane Library. In our study, we used randomized controlled trials (RCT) that evaluated the effects of exercise programs during pregnancy on labor and delivery. The results are summarized as relative risks. RESULTS: In the 16 RCTs that were included there were 3359 women. Women in exercise groups had a significantly lower risk of cesarean delivery (relative risk, 0.85; 95% confidence interval [CI], 0.73-0.99). Birthweight was not significantly reduced in exercise groups. The risk of instrumental delivery was similar among groups (relative risk, 1.00; 95% CI, 0.82-1.22). Data on Apgar score, episiotomy, epidural anesthesia, perineal tear, length of labor, and induction of labor were insufficient to draw conclusions. With the use of data from 11 studies (1668 women), our analysis showed that women in the exercise groups gained significantly less weight than women in control groups (mean difference, -1.13 kg; 95% CI, -1.49 to -0.78). CONCLUSION: Structured physical exercise during pregnancy reduces the risk of cesarean delivery. This is an important finding to convince women to be active during their pregnancy and should lead the physician to recommend physical exercise to pregnant women, when this is not contraindicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The new Swiss Chronic Obstructive Pulmonary Disease (COPD) Guidelines are based on a previous version, which was published 10 years ago. The Swiss Respiratory Society felt the need to update the previous document due to new knowledge and novel therapeutic developments about this prevalent and important disease. The recommendations and statements are based on the available literature, on other national guidelines and, in particular, on the GOLD (Global Initiative for Chronic Obstructive Lung Disease) report. Our aim is to advise pulmonary physicians, general practitioners and other health care workers on the early detection and diagnosis, prevention, best symptomatic control, and avoidance of COPD as well as its complications and deterioration.