885 resultados para Polymer-based
Resumo:
Contact friction plays a critical role in all the major thermoforming processes for polymers. However, these effects are very difficult to measure in practice and, as a result, have received little scientific investigation. In this work, two independently developed test methods for the measurement of elevated temperature polymer-to-polymer contact friction are presented, and their results are compared in detail for the first time. One is based on a modified moving sled friction test, whereas the other uses a rotational rheometer. In each case, friction tests were conducted between two plug and two sheet materials. The results show that broadly similar coefficients of friction were obtained from the two test methods. The measured values were quite low (<0.3) at lower temperatures and typically were higher for polypropylene (PP) sheet than for polystyrene (PS). On approaching the glass transition temperature for PS (95°C) and the crystalline melting point for PP (165°C), the friction coefficients rose very sharply, and both test techniques became increasingly unreliable. It was concluded that despite their physical differences, both test techniques were able to capture the highly temperature sensitive nature of friction between polymer materials used in thermoforming.
Resumo:
UC781 is a potent and poorly water-soluble nonnucleoside reverse transcriptase inhibitor being investi- gated as a potential microbicide for preventing sexual transmission of HIV-1. This study was designed to evaluate the in vivo release and pharmacokinetics of UC781 delivered from matrix-type intravaginal ring segments in rabbits. Three polymer matrices (polyurethane, ethylene vinyl acetate copolymer, and silicone elastomer) and two drug loadings (5 and 15 mg/segment) were evaluated in at least one of two independent studies for up to 28 days in vivo. Inter-study comparison of in vivo release, vaginal tissue, and plasma concentrations for similar formulations demonstrated good reproducibility of the animal model. Mean estimates for a 28-day in vivo release ranged from 0.35 to 3.17 mg UC781 per segment. Mean proximal vaginal tissue levels (adjacent to the IVR segment) were 8– 410 ng/g and did not change significantly with time for most formulations. Distal vaginal tissue levels of UC781 were 6- to 49-fold lower than proximal tissue levels. Mean UC781 plasma levels were low for all formulations, at 0.09–0.58 ng/mL. All formulations resulted in similar UC781 concentrations in vaginal tissue and plasma, except the low loading polyurethane group which provided significantly lower levels. Loading dependent release and pharmacokinetics were only clearly observed for the polyurethane matrix. Based on these results, intravaginal ring segments loaded with UC781 led to vaginal tissue concen- trations ranging from below to approximately two orders of magnitude higher than UC781’s EC50 under in vitro conditions (2.8 ng/mL), with little influence by polymer matrix or UC781 loading. Moreover, these findings support the use of rabbit vaginal pharmacokinetic studies in preclinical testing of microbicide intravaginal rings.
Resumo:
In polymer extrusion, delivery of a melt which is homogenous in composition and temperature is important for good product quality. However, the process is inherently prone to temperature fluctuations which are difficult to monitor and control via single point based conventional thermo- couples. In this work, the die melt temperature profile was monitored by a thermocouple mesh and the data obtained was used to generate a model to predict the die melt temperature profile. A novel nonlinear model was then proposed which was demonstrated to be in good agreement with training and unseen data. Furthermore, the proposed model was used to select optimum process settings to achieve the desired average melt temperature across the die while improving the temperature homogeneity. The simulation results indicate a reduction in melt temperature variations of up to 60%.
Resumo:
The present investigation deals with development and characteriza- tion of the liposomes-based freeze-dried rods for the vaginal delivery of gp140 antigen in mice. Positively charged, negatively charged and neutral liposomes were prepared and characterized for various parameters e.g. morphology, size, polydispersity index, zeta potential and antigen encapsulation efficiency. To further improve the efficacy of vaccine delivery, antigen encapsulated liposomes were formulated as polymer gel-based freeze-dried rods, which were then characterized for moisture content. The redispersibility of the liposomes-based freeze- dried rods was determined in simulated vaginal fluid and liposome gel was investigated for mucoadhesion. The developed liposome-based freeze-dried rods systems could offer potential as stable and practical dosage form for the mucosal immunization against HIV-1 infection.
Resumo:
The production of complex inorganic forms, based on naturally occurring scaffolds offers an exciting avenue for the construction of a new generation of ceramic-based bone substitute scaffolds. The following study reports an investigation into the architecture (porosity, pore size distribution, pore interconnectivity and permeability), mechanical properties and cytotoxic response of hydroxyapatite bone substitutes produced using synthetic polymer foam and natural marine sponge performs. Infiltration of polyurethane foam (60 pores/in2) using a high solid content (80wt %), low viscosity (0.126Pas) hydroxyapatite slurry yielded 84-91% porous replica scaffolds with pore sizes ranging from 50µm - 1000µm (average pore size 577µm), 99.99% pore interconnectivity and a permeability value of 46.4 x10-10m2. Infiltration of the natural marine sponge, Spongia agaricina, yielded scaffolds with 56- 61% porosity, with 40% of pores between 0-50µm, 60% of pores between 50-500µm (average pore size 349 µm), 99.9% pore interconnectivity and a permeability value of 16.8 x10-10m2. The average compressive strengths and compressive moduli of the natural polymer foam and marine sponge replicas were 2.46±1.43MPa/0.099±0.014GPa and 8.4±0.83MPa /0.16±0.016GPa respectively. Cytotoxic response proved encouraging for the HA Spongia agaricina scaffolds; after 7 days in culture medium the scaffolds exhibited endothelial cells (HUVEC and HDMEC) and osteoblast (MG63) attachment, proliferation on the scaffold surface and penetration into the pores. It is proposed that the use of Spongia agaricina as a precursor material allows for the reliable and repeatable production of ceramic-based 3-D tissue engineered scaffolds exhibiting the desired architectural and mechanical characteristics for use as a bone 3 scaffold material. Moreover, the Spongia agaricina scaffolds produced exhibit no adverse cytotoxic response.
Resumo:
The preparation and characterisation of a novel, UV-activated, solvent-based, colourimetric indicator for oxygen is described, comprising a redox dye (methylene blue, MB), semiconductor photocatalyst (Pt-TiO2), and a sacrificial electron donor (SED = glycerol), all dispersed/dissolved in a polymer medium (sulfonated polystyrene. SPS). Upon exposure to UVA light, the Pt-TiO2/MB/glycerol/SPS oxygen indicator is readily photobleached as the MB is converted into its oxygen-sensitive, leuco form, LMB. In contrast to its non-platinised TiO2 counterpart (TiO2/MB/glycerol/SPS oxygen indicator), the recovery of the original colour is faster (ca. 1.5 days cf. 5 days at 21 degrees C). This is due to the catalytic action of the 0.38 wt% platinum loaded onto the semiconductor photocatalyst. TiO2, on the oxidation of the photogenerated LMB by ambient O-2. Furthermore, by increasing the level of platinum loading, recovery times can be decreased further; e.g. a Pt-TiO2/MB/glycerol/SPS oxygen indicator with platinum level of 1.52 wt% recovers fully within 12 h. A study of the kinetics of recovery as a function of film thickness revealed the recovery step is not controlled by the diffusion of O-2 through the film, but instead dependent upon the slow rate of oxidation of LMB to MB by O-2 in the low dielectric polymer encapsulation medium. Other work showed this recovery is only moderately dependant upon temperatures above -10 degrees C and very sensitive to relative humidity above 30% RH. Potential uses of this UV light activated indicator are discussed briefly. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The preparation and characterisation of a novel, UV-activated solvent-based, colourimetric indicator for O-2 is described, comprising a redox dye (methylene blue, MB), semiconductor photocatalyst (TiO2), and a sacrificial electron donor (SED), all dispersed/dissolved in a polymer medium (sulfonated polystyrene, SPS). Upon exposure, the indicator is readily photobleached as the MB is converted into its oxygen-sensitive, leuco form, LMB. Unlike its water-based counterpart, the recovery of the original colour is very slow (ca. 5 days cf. 6 min), probably due to the largely hydrophobic nature of the polymer encapsulation medium. The kinetics of film photobleaching appear to fit very well, in terms of: irradiance, [TiO2] and [MB], to the usual Langmuir-Hinshelwood type equation associated with a photocatalytic process. The glycerol appears not only to function as a SED, but also a plasticizer and medium for dye dissolution. The kinetics of colour recovery of the photobleached film appear directly dependent upon the ambient level of O-2 but shows a more complex dependence upon the relative humidity, RH. The photobleached film does not recover any of its colour over a 24 h period if the RH
Resumo:
A UVB specific dosimeter is described comprising: a redox dye (2,6-dichloroindophenol, DCIP), a semiconductor ( tin(IV) oxide, SnO2) and a sacrificial electron donor ( glycerol) dispersed in a polymer ( hydroxy ethyl cellulose, HEC) film. The dosimeter is blue in the absence of UVB light but rapidly loses colour on exposure to UVB light. The spectral characteristics of a typical UVB dosimeter film and the mechanism by which the colour change occurs are detailed. DCIP UVB dosimeter films exhibit a response that is related to the irradiance level and duration of UVB exposure, the level of SnO2 present and to a lesser extent the level of glycerol present. The response of the dosimeter appears to be independent of dye concentration and film thickness. Furthermore, DCIP UVB dosimeter films respond to solar simulated light, exhibiting a colour loss that can be simply related to the Minimal Erythemal Dose (MED) exposure for skin type II. As a consequence, such indicators have potential for measuring solar radiation exposure and providing an early warning of erythema for most Caucasian skin (i.e. skin type II).
Resumo:
Nanocrystalline SnO2, ncSnO(2), is used as a photosensitiser in a colourimetric O-2 indicator that comprises a sacrificial electron donor, glycerol, a redox dye, methylene blue (MB), and an encapsulating polymer, hydroxyethyl cellulose (HEC). Upon exposure to a burst of UVB light the indicator is activated (photo-bleached) as the MB is photoreduced by the ncSnO(2) particles. In the absence of oxygen, the film stays bleached, but recovers its original colour upon exposure to oxygen. Unlike its TiO2-based predecessor, the HEC/glycerol/MB/ncSnO(2) O-2 indicator is not activated by UVA light from white fluorescent lamps, but is by UVB light. This feature provides much greater control in the activation of the indicator. Other work shows the rate of activation depends upon I-0.75, where I is the UVB irradiance, indicating a partial dependence upon the electron-hole recombination process. The half-life of the recovery of the original colour of a UV-activated film, t(50), is directly proportional to the ambient level of oxygen. The advantages of using this indicator in modified atmosphere packaging as a possible quality assurance indicator are discussed briefly. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
A novel UV dosimeter is described comprising a tetrazolium dye, neotetrazolium chloride (NTC), dissolved in a film of polymer, polyvinyl alcohol (PVA). The dosimeter is pale yellow/colourless in the absence of UV light, and turns red upon exposure to UV light. The spectral characteristics of a typical UV dosimeter film and the mechanism through which the colour change occurs are detailed. The NTC UV dosimeter films exhibit a response to UV light that is related to the intensity and duration of UV exposure, the level of dye present in the films and the thickness of the films themselves. The response of the dosimeter is temperature independent over the range 20-40 degrees C and, like most UV dosimeters, exhibits a cosine-like response dependence upon irradiance angle. The introduction of a layer of a UV-screening compound which slows the rate at which the dosimeter responds to UVR enables the dosimeter response to be tailored to different UV doses. The possible use of these novel dosimeters to measure solar UV exposure dose is discussed. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
A UV indicator/dosimeter based on benzyl viologen (BV2+) encapsulated in polyvinyl alcohol (PVA) is described. Upon exposure to UV light, the BV2+/PVA film turns a striking purple colour due to the formation of the cation radical, BV center dot+. The usual oxygen sensitivity of BV center dot+ is significantly reduced due to the very low oxygen permeability of the encapsulating polymer, PVA. Exposure of a typical BV2+/PVA film, for a set amount of time, to UVB light with different UV indices produces different levels of BV center dot+, as measured by the absorbance of the film at 550 nm. A plot of the change in absorbance at this wavelength, Delta Abs(550), as a function of UV index, UVI, produces a linear calibration curve which allows the film to be used as a UVB indicator, and a similar procedure could be employed to allow it to be used as a solar UVI indicator. A typical BV2+/PVA film generates a significant, semi-permanent (stable for > 24 h) saturated purple colour (absorbance similar to 0.8-0.9) upon exposure to sunlight equivalent to a minimal erythemal dose associated with Caucasian skin, i.e. skin type II. The current drawbacks of the film and the possible future use of the BV2+/PVA film as a personal solar UV dosimeter for all skin types are briefly discussed.
Resumo:
The quenching of the electronically-excited, lumophoric state of [Ru(bpy)(3)(2+)(Ph4B-)(2)] by oxygen is studied in a wide variety of neat plasticizers. The Stern-Volmer constant, K-SV, is found to be inversely dependent upon the viscosity of the quenching medium, although the natural lifetime of the electronically excited state of [RU(bPY)(3)(2+)(Ph4B-)(2)] is largely independent of medium. The least viscous of the plasticizers tested, triethyl phosphate, did not, however, produce highly sensitive optical oxygen sensors when used to plasticize [RU(bPY)(3)(2+)(Ph4B-)(2)]-containing cellulose acetate butyrate (CAB) and poly(methyl methacrylate) (PMMA) films, Instead, the compatibility of the polymer-plasticizer combination, as measured by the difference in the values of the solubility parameter of the two, appears to be a major factor in determining the overall oxygen sensitivity of the thin plastic films. For highly compatible polymer-plasticizer combinations, the plasticizer with the lowest viscosity produces films of the highest oxygen sensitivity. This situation arises because in the film the quenching process is partly diffusion-controlled and, as a result, the quenching rate constant is inversely proportional to the effective viscosity of the reaction medium.
Resumo:
A homologous family of dialkyl phthalates has been used to investigate the effect of plasticizer/polymer compatibility on the response characteristics of transparent, plastic, thin optical gas sensing films for CO2 and oxygen. Plasticizer/polymer compatibilities were determined through the value of the difference in solubility parameter, i.e. Delta delta, for the plasticizer and polymer with a Delta delta value of zero indicating high compatibility. A strong correlation was found between plasticizer/polymer compatibility and sensitivity in phenol red/ethyl cellulose CO2-sensitive films and this relationship extended to CO2-sensitive films based on other polymers such as polystyrene and poly(methyl methacrylate). It extended also to optical O-2-sensitive films implying that the relationship is general for thin-film optical sensors. Other results from the CO2-sensitive films in different polymers indicated that the film sensitivity is largely independent of the polymer matrix regardless of its inherent gas permeability, when a sufficient quantity of compatible plasticizer is present. (C) 1998 Elsevier Science B.V.
Resumo:
A general method of preparation of thin-film sensors for O-2, incorporating the dye ion-pair tris(4,7-diphenyl-1,10-phenanthroline) rutheninm(II) ditetraphenylborate, in a variety of different thin film polymer/plasticizer matrices is described, The sensitivity of the sensor depends upon the nature of the polymer matrix and plasticizer, A detailed study of one of these systems utilising the polymer poly(methyl methacrylate), PMMA, is reported. The sensitivity of this O-2 sensor depends markedly upon the plasticizer concentration and is largely independent of temperature (24,5-52.5 degrees C) and age (up to 30 d), When exposed to an alternating atmosphere of O-2 and N-2, a typical oxygen film sensor in PMMA exhibits a 0-90% response and recovery time of 0.4 and 4.5 s, respectively.