802 resultados para Photographic lenses.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

To eye care practitioners, citation metrics may seem to be a somewhat esoteric and irrelevant concept, far removed from the realities or real world, day-to-day clinical practice. However, quantitative analysis of the published literature is becoming increasingly important, and a beautiful example of this is presented in this issue of the Journal of Optometry. My former PhD student, Genís Cardona, has teamed up with Joan Sanz to undertake a thorough and telling analysis of current worldwide publishing trends in the contact lens field. When held in the mirror, this work reflects the growing contributions from Spanish researchers to the field...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is a comprehensive study of a large range of biometric and optical parameters in people with type 1 diabetes. The parameters of 74 people with type 1 diabetes and an age matched control group were assessed. Most of the people with diabetes had low levels of neuropathy, retinopathy and nephropathy. Marginal or no significant differences were found between groups for corneal shape, corneal thickness, pupil size, and pupil decentrations. Relative to the control group, the diabetes group demonstrated smaller anterior chamber depths, more curved lenses, greater lens thickness and lower lens equivalent refractive index. While the optics of diabetic eyes make them appear as older eyes than those of people of the same age without diabetes, the differences did not increase significantly with age. Age-related changes in the optics of the eyes of people with diabetes need not be accelerated if the diabetes is well controlled.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To document contact lens prescribing patterns in the United States between 2002 and 2014. Methods A survey of contact lens prescribing trends was conducted each year between 2002 and 2014, inclusive. Randomly selected contact lens practitioners were asked to provide information relating to 10 consecutive contact lens fits between January and March each year. Results Over the 13-year survey period, 1650 survey forms were received from US practitioners representing details of 7702 contact lens fits. The mean (±SD) age of lens wearers was 33.6 (±15.2) years, of whom 65.2% were female. Rigid lens new fits decreased from 13.0% in 2002 to 9.4% in 2014. Across this period, silicone hydrogels have replaced mid water contact lens hydrogels as the soft lens material of choice. Toric lenses represented about 25 to 30% of all soft lens fits. Multifocal soft lenses are generally preferred to monovision. Daily disposable lens fits have recently increased, and in 2014, they represented 27.1% of all soft lens fits. Most lenses are prescribed on 1 to 2 weekly or monthly lens replacement regimen. Extended wear remains a minority lens wearing modality. The vast majority of those wearing reusable lenses use multipurpose lens care solutions. Lenses are mostly worn 7 d/wk. Conclusions This survey has revealed prescribing trends and preferences in the United States over the past 13 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have been collecting data on worldwide contact lens prescribing habits for almost 20 years. Over this time period, we have amassed prospective information about 315,000 contact lens fits in 59 countries. This article marks our 15th report in Contact Lens Spectrum and features a breakdown of more than 23,000 contact lens fits in 34 markets. As in previous years, our international network of coordinators distributed survey forms to eyecare practitioners in their market who then recorded generic information about the first 10 patients fit with contact lenses after receipt. Information is gathered about patient age and gender; whether the contact lenses are prescribed as a new fit or a refit; contact lens material, design, and replacement frequency; number of intended days per week of use; wearing modality; and care system. Contact lens fits are weighted to reflect the number of fits undertaken by each eyecare practitioner. The study data were entered and processed at the University of Manchester and at the University of Waterloo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Non-invasive measurements of the age dependence of refractive index distribution in human eye lenses in vitro using a novel X-ray Talbot Interferometry method. In their paper, the authors make frequent reference to our own work in which we employed magnetic resonance imaging (MRI) to make similar non-invasive measurements of the refractive index distribution in the human eye lens [2, 3]. Prior to the current work, ours was the only method for making such measurements both non-invasively and without prior assumptions about the shape of the refractive index distribution. For this reason, the latest work is to be welcomed. However at several points in the paper, Pierscionek et al. [1] make statements about our technique which are factually incorrect...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To explore the effect of small-aperture optics, designed to aid presbyopes by increasing ocular depth-of-focus, on measurements of the visual field. Methods Simple theoretical and ray-tracing models were used to predict the impact of different designs of small-aperture contact lenses or corneal inlays on the proportion of light passing through natural pupils of various diameters as a function of the direction in the visual field. The left eyes of five healthy volunteers were tested using three afocal, hand-painted opaque soft contact lenses (www.davidthomas.com). Two were opaque over a 10 mm diameter but had central clear circular apertures of 1.5 and 3.0 mm in diameter. The third had an annular opaque zone with inner and outer diameters of 1.5 and 4.0 mm, approximately simulating the geometry of the KAMRA inlay (www.acufocus.com). A fourth, clear lens was used for comparison purposes. Visual fields along the horizontal meridian were evaluated up to 50° eccentricity with static automated perimetry (Medmont M700, stimulus Goldmann-size III; www.medmont.com). Results According to ray-tracing, the two lenses with the circular apertures were expected to reduce the relative transmittance of the pupil to zero at specific field angles (around 60° for the conditions of the experimental measurements). In contrast, the annular stop had no effect on the absolute field but relative transmittance was reduced over the central area of the field, the exact effects depending upon the natural pupil diameter. Experimental results broadly agreed with these theoretical expectations. With the 1.5 and 3.0 mm pupils, only minor losses in sensitivity (around 2 dB) in comparison with the clear-lens case occurred across the central 10° radius of field. Beyond this angle, sensitivity losses increased, to reach about 7 dB at the edge of the measured field (50°). The field results with the annular stop showed at most only a slight loss in sensitivity (≤3 dB) across the measured field. Conclusion The present theoretical and experimental results support earlier clinical findings that KAMRA-type annular stops, unlike circular artificial pupils, have only minor effects on measurements of the visual field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Seven photographic reproductions of a white porcelain ceremonial drinking cup used circa 1715 by the local Chevra Kadisha (burial society) in Eisenstadt, Austria, with Hebrew text and depictions of a Jewish funeral around the circumference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A first order optical system is investigated in full generality within the context of wave optics. The problem is reduced to a study of the ray transfer matrices. The simplest such systems correspond to axially symmetric propagation. Realization of such systems by centrally located lenses separated by finite distances is studied. It is shown that, contrary to the commonly held view, the set of first order systems that can be realized using axially symmetric thin lenses exhausts the entire SL(2, R) group; at most three lenses are needed to realize any element of this group. In particular, the inverse of free propagation can be so realized. Among anisotropic systems it is again shown that every element of the lens group Sp(4, R) can be realized using a finite number of thin lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To quantify the influence of short-term wear of miniscleral contact lenses on the morphology of the corneo-scleral limbus, the conjunctiva, episclera and sclera. METHODS OCT images of the anterior eye were captured before, immediately following 3h of wear and then 3h after removal of a miniscleral contact lens for 10 young (27±5 years) healthy participants (neophyte rigid lens wearers). The region of analysis encompassed 1mm anterior, to 3.5mm posterior to the scleral spur. Natural diurnal variations in thickness were measured on a separate day and compensated for in subsequent analyses. RESULTS Following 3h of lens wear, statistically significant tissue thinning was observed across all quadrants, with a mean decrease in thickness of -24.1±3.6μm (p<0.001), which diminished, but did not return to baseline 3h after lens removal (-16.9±1.9μm, p<0.001). The largest tissue compression was observed in the superior quadrant (-49.9±8.5μm, p<0.01) and in the annular zone 1.5mm from the scleral spur (-48.2±5.7μm), corresponding to the approximate edge of the lens landing zone. Compression of the conjunctiva/episclera accounted for about 70% of the changes. CONCLUSIONS Optimal fitting miniscleral contact lenses worn for three hours resulted in significant tissue compression in young healthy eyes, with the greatest thinning observed superiorly, potentially due to the additional force of the eyelid, with a partial recovery of compression 3h after lens removal. Most of the morphological changes occur in the conjunctiva/episclera layers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The crystal and molecular structure of the title compound (1) has been determined by the heavy-atom method from 1038 observed three-dimensional photographic data. Crystals are orthorhombic, with a = 20.07 ± 0.02, b= 10.05 ± 0.02, c= 7.31 ± 0.01 Å, space group P212121, with Z= 4. The structure was refined by block diagonal leastsquares to R 0.099. The conformation of the norbornane moiety is discussed. The seven-membered ring portion of the molecule adopts an approximate chair conformation. The packing of the molecules in the crystal is mainly a consequence of van der Waals interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ten Percent Terror brings together leading creatives from the fields of contemporary theatre, contemporary dance, music theatre, circus and digital arts in the first collaboration of its kind. Commissioned by Brisbane Powerhouse, with support from the Anzac Centenary Arts and Culture Fund and in partnership with Dancenorth and Company 2, this is an inter-disciplinary work that combines theatrical narrative with eloquent physicality, through circus and dance, to express certain truths of the soldiers' experience. This production will be a circus-narrative that uses the form and language of circus to express the key themes of risk, panic and brotherhood. Ten Percent Terror is intended to be a work of scale, yet also intimacy: of stillness and panic, inertia and chaos. Project partners, Dancenorth and Company 2, share the vision to use contemporary artistic disciplines to connect younger and modern audiences to the ANZAC legacy, perhaps offering a connection for those audiences that they may not find through more traditional art forms. The development process has included a community research project in Townsville, conducted by Shane Pike, which explored contemporary Australians’ stories through interviews with serving military personnel and the local community, as well as collecting photographic documentation and other artefacts from around Townsville. This was followed by an archival research project in Brisbane, where Pike reviewed letters, photographs and personal accounts of soldiers from WW1. The results of these projects will be used by the creative team to inform the development of Ten Percent Terror. Given Townsville’s reputation as Australia’s ‘garrison’ city, the project partners plan to deliver the world premiere performance of Ten Percent Terror in Townsville in late 2015. It is intended that Ten Percent Terror will receive its Brisbane premiere in November 2015 at Brisbane Powerhouse, as part of a four-performance season. This expert panel included discussion of the project and its place in analysing key aspects of Australia's wartime history.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The complex crystallizes in the space group P21/c with four formula units in a unit cell of dimensions a= 12.747, b= 7.416, c= 17.894 A and/3= 90.2 °. The structure has been solved by the symbolic addition procedure using three-dimensional photographic data and refined to an R value of 0.079 for 2019 observed reflexions. The pyramidal nature of the two hetero nitrogen atoms in the antipyrine molecule is inter:nediate between that observed in free antipyrine and in some of its metal complexes. The molecule is more polar than that in crystals of free antipyrine but less so compared with that in metal complexes. In the salicylic acid molecule, the hydroxyl group forms an internal hydrogen bond with one of the oxygen atoms in the carboxyl group. The association between the salicylic acid and the antipyrine molecules is achieved through an intermolecular hydrogen bond with the other carboxyl oxygen atom in the salicylic acid molecule as the proton donor and the carboxyl oxygen atom of the antipyrine molecule as the acceptor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Teachers working in regional, rural and remote areas of Western Australia often experience a strong sense of geographic and social isolation from peers, colleagues and appropriate support mechanisms due to the huge distances between towns and communities. The projects described here have focused on the use of technology to enhance both teacher and student learning; and assist with Indigenous education and teacher professional learning. Connecting and collaborating through technologies is emerging as a powerful tool for motivating and engaging both teachers and learners within schools. Coupled with the direction of the current Federal Government with the Digital Education Revolution and the Digital Regions initiatives, opportunities for better serving regional, rural and remote communities are discussed, as are some of the current issues and needs related to these schools in Western Australia. The scope of these projects has been such that three guiding principles have been implemented through contextual lenses of varying foci - at the level of an individual, a school, and a community.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Photography is now a highly automated activity where people enjoy phototaking by pointing and pressing a button. While this liberates people from having to interact with the processes of photography, e.g., controlling the parameters of the camera or printing images in the darkroom, we argue that an engagement with such processes can in fact enrich people's experience of phototaking. Drawing from fieldwork with members of a film-based photography club, we found that people who engage deeply with the various processes of phototaking experienced photography richly and meaningfully. Being able to participate fully in the entire process gave them a sense of achievement over the final result. Having the opportunity to engage with the process also allowed them to learn and hone their photographic skills. Through this understanding, we can imagine future technologies that enrich experiences of photography through providing the means to interact with photographic processes in new ways.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissatisfaction with, and discontinuation from, contact lens wear is a source of major frustration and inconvenience to users, and a problem that is thought to cost the contact lens industry hundreds of millions of dollars each year. By directly and non-invasively monitoring inflammatory cells in the tissues at the front of the eye in symptomatic and asymptomatic lens wearers, the candidate has been able to demonstrate an inflammatory basis for contact lens discomfort. This finding may pave the way towards the development of strategies to make contact lenses more safe and afford greater levels of comfort.