1000 resultados para Operação de sistemas de distribuição


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work resulted from a study about coolant filtration systems in industries with metalworking process in large scale. The filtration and element filter world markets move billions of Reais per year and have a promissory future considering that with the global requirements of sustainable economic development, many companies invest in new filtering technology. Either known as coolant or cutting fluid, it is used to lubricate e cool parts during machining and is necessary due to the high volume demanded in the several machining operations and to the high cost of the product. Therefore, there is the need for recycling the product after its use. The work shows the technology and fundamentals of filtration as well as different filtering elements, filtration systems and scale contamination used in the industry. Also, there is a differentiation between filtration of the surface type (cake) and depth filtration and shows the basic theory of filtration by mathematic models in different operational conditions. Ultimately, project criteria for a coolant filtration system selection is shown followed by technical-operational details of a real vacuum filtration system and a case study aiming the operational cost reduction of the system

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ce document présente l'analyse de la qualité de l'énergie dans une centrale solaire photovoltaïque - avec une capacité installée de 1 MWpico, relié au réseau de distribution d’électricité en 11,9 kV, qui a comme but connaître et également de comparer à la norme nationale actuelle, les effets de la qualité de l'énergie électrique résultant de l'utilisation de cette type matrice génératrice. Le rapport a été basé sur des niveaux spécifiés dans le module 8 des Procédures de distribution d'électricité dans le réseau national d'électricité - PRODIST, qui précise les directrices sur la question de la qualité de l'énergie électrique sur le territoire brésilien. Il a été considéré aussi les recommandations internationales 929 et 1547, qui proposent des pratiques recommandées concernant des systèmes de génération de l'énergie solaire PV (photovoltaïque), et également des normes pour le raccordement de ces types de sources au réseau de distributions d'électricité, tous deux établis par l'Institut des ingénieurs électriciens et électroniciens, largement connu comme IEEE. Le développement et le travail sur le terrain a eu lieu de manière continué, et non dans des moments spécifiques, assurant de cette manière, la fiabilité des données obtenues

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Distribution networks are formed by long lines that carry electricity substations to homes and industries. These lines have associated impedance and depending on operating conditions of the network these impedances may vary. This paper provides a detailed analysis of the effects observed in studies of voltage drop, short circuit and electrical losses, when considered the drivers sequence impedances used in primary distribution network at different temperatures. Therefore, it is initially presented a calculation methodology and details the factors that influence the final values. The methodology presented tackles in a practical way the main factors that directly or indirectly influence the values of the impedances as an emblematic example and will be properly dealt with throughout the paper is the effect of temperature on the values of the sequence impedances. More specifically is dealt with the case of XLPE cables protected, by having a higher maximum operating temperature than the operating temperature of the network. The effects observed in the power flow generated when considering the impedance values at both temperatures were analyzed. The impedance drivers tend to increase with increasing temperature. Thus the impedance of the conductor XLPE protected will tend to be greater for the maximum operating temperature for which the operating temperature of the network, resulting in greater voltage drop and higher electrical losses

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This monograph aims to contribute to the understanding and analysis of extreme events and its correlation with anthropogenic actions, in order to understand the levels of human interference in the environment and to identify potential social and environmental damage that such events may result in Ubatuba, located on the northern coast of São Paulo state. Therefore, two strategies were established, on one hand, episodic analysis of extreme weather events, and on the other, the analysis of the impact of atmospheric phenomena in everyday society. In this case we gave greater emphasis to analysis years that had higher total rainfall. In this sense, the research was based on the standard deviation technique and percentages, which supported to characterize the exceptional rainy years, in addition, use of rhythm analysis technique that has helped to identify the active atmospheric systems. From a qualitative point of view, field works were carried out in order to make use of news by the local press and civil defense for years considered extreme (positive standard deviation). From this, it was analyzed how the extreme episodes of rainfall trigger repercussions in geographic space. Also the spatial distribution of rainfall were carried out by means of quantitative analysis of six rain gauges. It was found that the highest occurrences of impacts, are located in the central areas of the city, as well as the highest rainfall totals. In fact, Ubatuba/SP suffers from very high rainfall totals and has a singularity on the climate...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

No Brasil os acidentes por picada de escorpião são considerados um problema para saúde pública, uma vez que este agravo pode levar ao óbito caso não haja um tratamento adequado. Assim, no município de Presidente Prudente/SP o órgão responsável pelo combate aos escorpiões é o Centro de Controle de Zoonoses (CCZ), que tem por finalidade notificar a aparição de escorpiões no município, promovendo portanto, as devidas informações à população com finalidade de evitar acidentes. Desse modo, com o uso dos Sistemas de Informações Geográficas (SIGs) aplicados à técnicas de estatística espacial, foi possível elaborar mapas de distribuição das notificações de escorpiões referente aos anos de 2012 e 2013, por meio dos métodos da geocodificação de endereços; estimador de intensidade de Kernel; índice de Moran função (LISA); quantidade de notificações por setor censitário e interpolação por vizinho mais próximo. Como resultado desta análise, o trabalho fornece informações ao CCZ sobre a distribuição de tal fenômeno para que fosse possível um controle direcionado os locais mais infestados, economizando tempo e recursos financeiros, visando o bem estar da população

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Proteção de Plantas) - FCA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work aimed to evaluate some aspects of construction and operation of full-scale best management practices and their effects on infiltration loading rate. Two systems were studied: i) filter-swale-trench (FST) and ii) infiltration well (IW). In these units, field essays and full-scale measurements were made in order to assess the soil permeability. Further, the fine particles transportation and the geotextile blanket permeability were determined before and after operation. The results pointed out that there were soil transportation to inside the FST and IW systems, despite of the installed protections, and that these material were responsible for diminishing the geotextile (reduction from 30 to 90% for FST and 40 to 70% for IW) and the full-scale infiltration loading rates (varying from 4,7 x 10-6 to 10-5 m.s-1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS