789 resultados para One-trial tolerance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rice (Oryza sativa L.) plants are susceptible to low temperature during the young microspore stage, which occurs 10-12 days before heading. Low temperature at this time increases spikelet sterility which can cause massive yield loss. Increasing the cold tolerance of cultivars can reduce yield variability in temperate rice-growing environments. Two experiments were conducted in cold air screenings and two were conducted in cold water screenings to examine genotypic variation for cold tolerance, explore flowering traits related to spikelet sterility, and investigate whether the results reflect the level of cold tolerance determined previously in the field. Cold air screenings imposed day/night temperatures of 27 degrees C/13 degrees C, 25 degrees C/15 degrees C and 32 degrees C/25 degrees C following particle initiation until 50% heading, while cold water screenings maintained a relatively constant 19 degrees C. The variation in the commencement of low air temperature treatment did not have an effect on the level of spikelet sterility, indicating that exposure to low temperature during the young microspore stage was more important than the duration of exposure. Spikelet sterility of common cultivars showed a significant correlation between cold air and cold water screenings (r(2) = 0.63, p < 0.01), cold air and field screenings (r(2) = 0.52, p < 0.01) and cold water and field screenings (r(2) = 0.53, p < 0.01), indicating that cold air and cold water can be used for screening genotypes for low temperature tolerance. HSC55, M 103 and Jyoudeki were identified as cold tolerant and Doongara, Sasanishiki and Nipponbare as susceptible cultivars. There was a significant negative relationship between spikelet sterility and both the number of engorged pollen grains per anther and anther area only after imposing cold air and cold water treatment hence, it was concluded that these flowering traits were facultative in nature. In addition, cultivars originating from Australia and California were inefficient at producing filled grain with similar sized anthers containing a similar number of engorged pollen grains as cultivars from other origins. One suggested reason for this poor conversion to filled grain of cultivars from Australia and California may be associated with their small stigma area, particularly when exposed to low temperature conditions. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A randomized double-blind Phase I Trial was conducted to evaluate safety, tolerability, and immunogenicity of a yellow fever (YF)-dengue 2 (DEN2) chimera (ChimeriVax™-DEN2) in comparison to that of YF vaccine (YF-VAX®). Forty-two healthy YF naïve adults randomly received a single dose of either ChimeriVax™-DEN2 (high dose, 5 log plaque forming units [PFU] or low dose, 3 log PFU) or YF-VAXâ by the subcutaneous route (SC). To determine the effect of YF pre-immunity on the ChimeriVaxTM-DEN2 vaccine, 14 subjects previously vaccinated against YF received a high dose of ChimeriVax™-DEN2 as an open-label vaccine. Most adverse events were similar to YF-VAX® and of mild to moderate intensity, with no serious side-effects. One hundred percent and 92.3% of YF naïve subjects inoculated with 5.0 and 3.0 log10 PFU of ChimeriVaxTM-DEN2, respectively, seroconverted to wt DEN2 (strain 16681); 92% of subjects inoculated with YF-VAX® seroconverted to YF 17D virus but none of YF naïve subjects inoculated with ChimeriVax-DEN2 seroconverted to YF 17D virus. Low seroconversion rates to heterologous DEN serotypes 1, 3, and 4 were observed in YF naïve subjects inoculated with either ChimeriVax™-DEN2 or YF-VAX®. In contrast, 100% of YF immune subjects inoculated with ChimeriVax™-DEN2 seroconverted to all 4 DEN serotypes. Surprisingly, levels of neutralizing antibodies to DEN 1, 2, and 3 viruses in YF immune subjects persisted after 1 year. These data demonstrated that 1) the safety and immunogenicity profile of the ChimeriVax™-DEN2 vaccine is consistent with that of YF-VAX®, and 2) pre-immunity to YF virus does not interfere with ChimeriVaxTM-DEN2 immunization, but induces a long lasting and cross neutralizing antibody response to all 4 DEN serotypes. The latter observation can have practical implications toward development of a dengue vaccine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Most individuals with lung cancer have symptoms for several months before presenting to their GP. Earlier consulting may improve survival. Aim: To evaluate whether a theory-based primary care intervention increased timely consulting of individuals with symptoms of lung cancer. Design and setting: Open randomised controlled trial comparing intervention with usual care in two general practices in north-east Scotland. Method: Smokers and ex-smokers aged ≥55 years were randomised to receive a behavioural intervention or usual care. The intervention comprised a single nurse consultation at participants' general practice and a self-help manual. The main outcomes were consultations within target times for individuals with new chest symptoms (≤3 days haemoptysis, ≤3 weeks other symptoms) in the year after the intervention commenced, and intentions about consulting with chest symptoms at 1 and 6 months. Results: Two hundred and twelve participants were randomised and 206 completed the trial. The consultation rate for new chest symptoms in the intervention group was 1.19 (95% confidence interval [CI] = 0.92 to 1.53; P = 0.18) times higher than in the usual-care group and the proportion of consultations within the target time was 1.11 (95% CI = 0.41 to 3.03; P = 0.83) times higher. One month after the intervention commenced, the intervention group reported intending to consult with chest symptoms 31 days (95% CI = 7 to 54; P = 0.012) earlier than the usual care group, and at 6 months this was 25 days (95% CI = 1.5 to 48; P = 0.037) earlier. Conclusion: Behavioural intervention in primary care shortened the time individuals at high risk of lung disease intended to take before consulting with new chest symptoms (the secondary outcome of the study), but increases in consultation rates and the proportions of consultations within target times were not statistically significant. © British Journal of General Practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To assess whether blood pressure control in primary care could be improved with the use of patient held targets and self monitoring in a practice setting, and to assess the impact of these on health behaviours, anxiety, prescribed antihypertensive drugs, patients' preferences, and costs. DESIGN: Randomised controlled trial. SETTING: Eight general practices in south Birmingham. PARTICIPANTS: 441 people receiving treatment in primary care for hypertension but not controlled below the target of < 140/85 mm Hg. INTERVENTIONS: Patients in the intervention group received treatment targets along with facilities to measure their own blood pressure at their general practice; they were also asked to visit their general practitioner or practice nurse if their blood pressure was repeatedly above the target level. Patients in the control group received usual care (blood pressure monitoring by their practice). MAIN OUTCOME MEASURES: Primary outcome: change in systolic blood pressure at six months and one year in both intervention and control groups. Secondary outcomes: change in health behaviours, anxiety, prescribed antihypertensive drugs, patients' preferences of method of blood pressure monitoring, and costs. RESULTS: 400 (91%) patients attended follow up at one year. Systolic blood pressure in the intervention group had significantly reduced after six months (mean difference 4.3 mm Hg (95% confidence interval 0.8 mm Hg to 7.9 mm Hg)) but not after one year (mean difference 2.7 mm Hg (- 1.2 mm Hg to 6.6 mm Hg)). No overall difference was found in diastolic blood pressure, anxiety, health behaviours, or number of prescribed drugs. Patients who self monitored lost more weight than controls (as evidenced by a drop in body mass index), rated self monitoring above monitoring by a doctor or nurse, and consulted less often. Overall, self monitoring did not cost significantly more than usual care (251 pounds sterling (437 dollars; 364 euros) (95% confidence interval 233 pounds sterling to 275 pounds sterling) versus 240 pounds sterling (217 pounds sterling to 263 pounds sterling). CONCLUSIONS: Practice based self monitoring resulted in small but significant improvements of blood pressure at six months, which were not sustained after a year. Self monitoring was well received by patients, anxiety did not increase, and there was no appreciable additional cost. Practice based self monitoring is feasible and results in blood pressure control that is similar to that in usual care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context: Subclinical hypothyroidism (SCH) and cognitive dysfunction are both common in the elderly and have been linked. It is important to determine whether T4 replacement therapy in SCH confers cognitive benefit. Objective: Our objective was to determine whether administration of T4 replacement to achieve biochemical euthyroidism in subjects with SCH improves cognitive function. Design and Setting: We conducted a double-blind placebo-controlled randomized controlled trial in the context of United Kingdom primary care. Patients: Ninety-four subjects aged 65 yr and over (57 females, 37 males) with SCH were recruited from a population of 147 identified by screening. Intervention: T4 or placebo was given at an initial dosage of one tablet of either placebo or 25 µg T4 per day for 12 months. Thyroid function tests were performed at 8-weekly intervals with dosage adjusted in one-tablet increments to achieve TSH within the reference range for subjects in treatment arm. Fifty-two subjects received T4 (31 females, 21 males; mean age 73.5 yr, range 65–94 yr); 42 subjects received placebo (26 females, 16 males; mean age 74.2 yr, 66–84 yr). Main Outcome Measures: Mini-Mental State Examination, Middlesex Elderly Assessment of Mental State (covering orientation, learning, memory, numeracy, perception, attention, and language skills), and Trail-Making A and B were administered. Results: Eighty-two percent and 84% in the T4 group achieved euthyroidism at 6- and 12-month intervals, respectively. Cognitive function scores at baseline and 6 and 12 months were as follows: Mini-Mental State Examination T4 group, 28.26, 28.9, and 28.28, and placebo group, 28.17, 27.82, and 28.25 [not significant (NS)]; Middlesex Elderly Assessment of Mental State T4 group, 11.72, 11.67, and 11.78, and placebo group, 11.21, 11.47, and 11.44 (NS); Trail-Making A T4 group, 45.72, 47.65, and 44.52, and placebo group, 50.29, 49.00, and 46.97 (NS); and Trail-Making B T4 group, 110.57, 106.61, and 96.67, and placebo group, 131.46, 119.13, and 108.38 (NS). Linear mixed-model analysis demonstrated no significant changes in any of the measures of cognitive function over time and no between-group difference in cognitive scores at 6 and 12 months. Conclusions: This RCT provides no evidence for treating elderly subjects with SCH with T4 replacement therapy to improve cognitive function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background - Agitation in Alzheimer’s disease (AD) is common and associated with poor patient life-quality and carer distress. The best evidence-based pharmacological treatments are antipsychotics which have limited benefits with increased morbidity and mortality. There are no memantine trials in clinically significant agitation but post-hoc analyses in other populations found reduced agitation. We tested the primary hypothesis, memantine is superior to placebo for clinically significant agitation, in patients with moderate-to-severe AD. Methods and Findings - We recruited 153 participants with AD and clinically significant agitation from care-homes or hospitals for a double-blind randomised-controlled trial and 149 people started the trial of memantine versus placebo. The primary outcome was 6 weeks mixed model autoregressive analysis of Cohen-Mansfield Agitation Inventory (CMAI). Secondary outcomes were: 12 weeks CMAI; 6 and 12 weeks Neuropsychiatric symptoms (NPI), Clinical Global Impression Change (CGI-C), Standardised Mini Mental State Examination, Severe Impairment Battery. Using a mixed effects model we found no significant differences in the primary outcome, 6 weeks CMAI, between memantine and placebo (memantine lower -3.0; -8.3 to 2.2, p = 0.26); or 12 weeks CMAI; or CGI-C or adverse events at 6 or 12 weeks. NPI mean difference favoured memantine at weeks 6 (-6.9; -12.2 to -1.6; p = 0.012) and 12 (-9.6; -15.0 to -4.3 p = 0.0005). Memantine was significantly better than placebo for cognition. The main study limitation is that it still remains to be determined whether memantine has a role in milder agitation in AD. Conclusions - Memantine did not improve significant agitation in people with in moderate-to-severe AD. Future studies are urgently needed to test other pharmacological candidates in this group and memantine for neuropsychiatric symptoms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low-cost, high-capacity optical transmission systems are required for metropolitan area networks. Direct-detected multi-carrier systems are attractive candidates, but polarization mode dispersion (PMD) is one of the major impairments that limits their performance. In this paper, we report the first experimental analysis of the PMD tolerance of a 288Gbit/s NRZ-OOK Coherent Wavelength Division Multiplexing system. The results show that this impairment is determined primarily by the subcarrier baud rate. We confirm the robustness of the system to PMD by demonstrating error-free performance over an unrepeatered 124km field-installed single-mode fiber with a negligible penalty of 0.3dB compared to the back-to-back measurements. (C) 2010 Optical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Evaluating the impact of splitting toric power on patient tolerance to misorientation such as with intraocular lens rotation. Setting: University vision clinic. Methods: Healthy, non astigmats had +1.50D astigmatism induced with spectacle lenses at 90°, 135°, 180° and +3.00D at 90°. Two correcting cylindrical lenses of the opposite sign and half the power each were subsequently added to the trial frame misaligned by 0°, 5° or 10° in a random order and misorientated from the initial axis in a clockwise direction by up to 15° in 5° steps. A second group of adapted astigmats with between 1.00 and 3.00DC had their astigmatism corrected with two toric spectacle lenses of half the power separated by 0°, 5° or 10° and misorientated from the initial axis in both directions by up to 15° in 5° steps. Distance, high contrast visual acuity was measured using a computerised test chart at each lens misalignment and misorientation. Results: Misorientation of the split toric lenses caused a statistically significant drop in visual acuity (F= 70.341; p< 0.001). Comparatively better acuities were observed around 180°, as anticipated (F= 3.775; p= 0.035). Misaligning the split toric power produced no benefit in visual acuity retention with axis misorientation when subjects had astigmatism induced with a low (F= 2.190, p= 0.129) or high cylinder (F= 0.491, p= 0.617) or in the adapted astigmats (F= 0.120, p= 0.887). Conclusion: Misalignment of toric lens power split across the front and back lens surfaces had no beneficial effect on distance visual acuity, but also no negative effect. © 2013 British Contact Lens Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Stroke prevention in atrial fibrillation (AF), most commonly with warfarin, requires maintenance of a narrow therapeutic target (INR 2.0 to 3.0) and is often poorly controlled in practice. Poor patient-understanding surrounding AF and its’ treatment may contribute to patient’s willingness to adhere to recommendations. Method: A theory-driven intervention, developed using patient interviews and focus groups, consisting of a one-off group session (1-6 patients) utilising an ‘expert-patient’ focussed DVD, educational booklet, self-monitoring diary and worksheet, was compared in a randomised controlled trial (ISRCTN93952605) against usual care, with patient postal follow-ups at 1, 2, 6, and 12-months. Ninety-seven warfarin-naïve AF patients were randomised to intervention (n=46, mean age (SD) 72.0 (8.2), 67.4% men), or usual care (n=51, mean age (SD) 73.7 (8.1), 62.7% men), stratified by age, sex, and recruitment centre. Primary endpoint was time within therapeutic range (TTR); secondary endpoints included knowledge, quality of life, anxiety/depression, beliefs about medication, and illness perceptions. Main findings: Intervention patients had significantly higher TTR than usual care at 6-months (76.2% vs. 71.3%; p=0.035); at 12-months these differences were not significant (76.0% vs. 70.0%; p=0.44). Knowledge increased significantly across time (F (3, 47) = 6.4; p<0.01), but there were no differences between groups (F (1, 47) = 3.3; p = 0.07). At 6-months, knowledge scores predicted TTR (r=0.245; p=0.04). Patients’ scores on subscales representing their perception of the general harm and overuse of medication, as well as the perceived necessity of their AF specific medications predicted TTR at 6- and 12-months. Conclusions: A theory-driven educational intervention significantly improves TTR in AF patients initiating warfarin during the first 6-months. Adverse clinical outcomes may potentially be reduced by improving patients’ understanding of the necessity of warfarin and reducing their perception of treatment harm. Improving education provision for AF patients is essential to ensure efficacious and safe treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Needleless connectors are being increasingly used for direct access to intravascular catheters. However, the potential for microbial contamination of these devices and subsequent infection risk is still widely debated. In this study the microbial contamination rate associated with three-way stopcock luers with standard caps attached was compared to those with Y-type extension set luers with Clearlink® needleless connectors attached. Fifty patients undergoing cardiothoracic surgery who required a central venous catheter (CVC) as part of their peri- and postoperative management were studied for microbial contamination of CVC luers following 72 hrs in situ. Each patient's CVC was randomly designated to have either the three-way stopcocks with caps (control patients) or Clearlink® Y-type extension sets (test patients). Prior to, and following each manipulation of the three-way stopcock luers or Clearlink® devices, a 70% (v/v) isopropyl alcohol swab was used for disinfection of the connections. The microbial contamination of 393 luers, 200 with standard caps and 193 with Clearlink® attached, was determined. The internal surfaces of 20 of 200 (10%) three-way stopcock luers with standard caps were contaminated with micro-organisms whereas only one of 193 (0.5%) luers with Clearlink® attached was contaminated (P < 0.0001). These results demonstrate that the use of the Clearlink® device with a dedicated disinfection regimen reduces the internal microbial contamination rate of CVC luers compared with standard caps. The use of such needle-free devices may therefore reduce the intraluminal risk of catheter-related bloodstream infection and thereby supplement current preventive guidelines. © 2006 The Hospital Infection Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Age-related macular disease is the leading cause of blind registration in the developed world. One aetiological hypothesis involves oxidation, and the intrinsic vulnerability of the retina to damage via this process. This has prompted interest in the role of antioxidants, particularly the carotenoids lutein and zeaxanthin, in the prevention and treatment of this eye disease. Methods: The aim of this randomised controlled trial is to determine the effect of a nutritional supplement containing lutein, vitamins A, C and E, zinc, and copper on measures of visual function in people with and without age-related macular disease. Outcome measures are distance and near visual acuity, contrast sensitivity, colour vision, macular visual field, glare recovery, and fundus photography. Randomisation is achieved via a random number generator, and masking achieved by third party coding of the active and placebo containers. Data collection will take place at nine and 18 months, and statistical analysis will employ Student's t test. Discussion: A paucity of treatment modalities for age-related macular disease has prompted research into the development of prevention strategies. A positive effect on normals may be indicative of a role of nutritional supplementation in preventing or delaying onset of the condition. An observed benefit in the age-related macular disease group may indicate a potential role of supplementation in prevention of progression, or even a degree reversal of the visual effects caused by this condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Service innovations in retailing have the potential to benefit consumers as well as retailers. This research models key factors associated with the trial and continuous use of a specific self-service technology (SST), the personal shopping assistant (PSA), and estimates retailer benefits from implementing that innovation. Based on theoretical insights from prior SST studies, diffusion of innovation literature, and the technology acceptance model (TAM), this study develops specific hypotheses and tests them on a sample of 104 actual users of the PSA and 345 nonusers who shopped at the retail store offering the PSA device. Results indicate that factors affecting initial trial are different from those affecting continuous use. More specifically, consumers' trust toward the retailer, novelty seeking, and market mavenism are positively related to trial, while technology anxiety hinders the likelihood of trying the PSA. Perceived ease of use of the device positively impacts continuous use while consumers' need for interaction in shopping environments reduces the likelihood of continuous use. Importantly, there is evidence on retailer benefits from introducing the innovation since consumers using the PSA tend to spend more during each shopping trip. However, given the high costs of technology, the payback period for recovery of investments in innovation depends largely upon continued use of the innovation by consumers. Important implications are provided for retailers considering investments in new in-store service innovations. Incorporation of technology within physical stores affords opportunities for the retailer to reduce costs, while enhancing service provided to consumers. Therefore, service innovations in retailing have the potential to benefit consumers as well as retailers. This research models key factors associated with the trial and continuous use of a specific SST in the retail context, the PSA, and estimates retailer benefits from implementing that innovation. In so doing, the study contributes to the nascent area of research on SSTs in the retail sector. Based on theoretical insights from prior SST studies, diffusion of innovation literature, and the TAM, this study develops specific hypotheses regarding the (1) antecedent effects of technological anxiety, novelty seeking, market mavenism, and trust in the retailer on trial of the service innovation; (2) the effects of ease of use, perceived waiting time, and need for interaction on continuous use of the innovation; and (3) the effect of use of innovation on consumer spending at the store. The hypotheses were tested on a sample of 104 actual users of the PSA and 345 nonusers who shopped at the retail store offering the PSA device, one of the early adopters of PSA in Germany. Data were analyzed using logistic regression (antecedents of trial), multiple regression (antecedents of continuous use), and propensity score matching (assessing retailer benefits). Results indicate that factors affecting initial trial are different from those affecting continuous use. More specifically, consumers' trust toward the retailer, novelty seeking, and market mavenism are positively related to trial, while technology anxiety hinders the likelihood of trying the PSA. Perceived ease of use of the device positively impacts continuous use, while consumers' need for interaction in shopping environments reduces the likelihood of continuous use. Importantly, there is evidence on retailer benefits from introducing the innovation since consumers using the PSA tend to spend more during each shopping trip. However, given the high costs of technology, the payback period for recovery of investments in innovation depends largely upon continued use of the innovation by consumers. Important implications are provided for retailers considering investments in new in-store service innovations. The study contributes to the literature through its (1) simultaneous examination of antecedents of trial and continuous usage of a specific SST, (2) the demonstration of economic benefits of SST introduction for the retailer, and (3) contribution to the stream of research on service innovation, as against product innovation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biomass pyrolysis to bio-oil is one of the promising sustainable fuels. In this work, relation between biomass feedstock element characteristic and crude bio-oil production yield and lower heating value was explored. The element characteristics considered in this study include moisture, ash, fix carbon, volatile matter, C, H, N, O, S, cellulose, hemicellulose, and lignin content. A semi-batch fixed bed reactor was used for biomass pyrolysis with heating rate of 30 °C/min from room temperature to 600 °C and the reactor was held at 600 °C for 1 h before cooling down. Constant nitrogen flow (1bar) was provided for anaerobic condition. Sago and Napier glass were used in the study to create different element characteristic of feedstock by altering mixing ratio. Comparison between each element characteristic to crude bio-oil yield and low heating value was conducted. The result suggested potential key element characteristic for pyrolysis and provide a platform to access the feedstock element acceptance range.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electric vehicles (EVs) and hybrid electric vehicles (HEVs) can reduce greenhouse gas emissions while switched reluctance motor (SRM) is one of the promising motor for such applications. This paper presents a novel SRM fault-diagnosis and fault-tolerance operation solution. Based on the traditional asymmetric half-bridge topology for the SRM driving, the central tapped winding of the SRM in modular half-bridge configuration are introduced to provide fault-diagnosis and fault-tolerance functions, which are set idle in normal conditions. The fault diagnosis can be achieved by detecting the characteristic of the excitation and demagnetization currents. An SRM fault-tolerance operation strategy is also realized by the proposed topology, which compensates for the missing phase torque under the open-circuit fault, and reduces the unbalanced phase current under the short-circuit fault due to the uncontrolled faulty phase. Furthermore, the current sensor placement strategy is also discussed to give two placement methods for low cost or modular structure. Simulation results in MATLAB/Simulink and experiments on a 750-W SRM validate the effectiveness of the proposed strategy, which may have significant implications and improve the reliability of EVs/HEVs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and aims: Glucagon-like peptide-1 (GLP-1) receptor agonists improve islet function and delay gastric emptying in subjects with type 2 diabetes mellitus. We evaluated 2-hour glucose, glucagon and insulin changes following a standardized mixed-meal tolerance test before and after 24 weeks of treatment with the once-daily prandial GLP-1 receptor agonist lixisenatide (approved for a therapeutic dose of 20 μg once daily) in six randomized, placebo-controlled studies within the lixisenatide Phase III GetGoal programme. In the studies, the mixed-meal test was conducted before and after: (1) lixisenatide treatment in patients insufficiently controlled despite diet and exercise (GetGoal-Mono), (2) lixisenatide treatment in combination with oral antidiabetic drugs (OADs) (GetGoal-M and GetGoal-S), or (3) lixisenatide treatment in combination with basal insulin ± OAD (GetGoal-Duo 1, GetGoal-L and GetGoal-L-Asia).Materials and methods: A meta-analysis was performed (lixisenatide n=1124 vs placebo n=707) combining ANCOVA least squares (LS) mean values using an inverse variance weighted analysis. Results: Lixisenatide significantly reduced 2-hour postprandial glucose from baseline (LS mean difference vs placebo: -4.9 mmol/L, p<0.0001, Figure) and glucose excursions (LS mean difference vs placebo: -4.5 mmol/L, p<0.0001). As measured in two studies, lixisenatide also reduced postprandial glucagon (LS mean difference vs placebo: -19.0 ng/L, p<0.0001) and insulin (LS mean difference vs placebo: -64.8 pmol/L, p<0.0001), although the glucagon/insulin ratio was increased (LS mean difference vs placebo: 0.15, p=0.02) compared with placebo. Conclusion: The results show that lixisenatide potently reduces the glucose excursion after meal ingestion in subjects with type 2 diabetes, in association with marked reductions in glucagon and insulin levels. It is suggested that diminished glucagon secretion and slower gastric emptying contribute to reduced hepatic glucose production and delayed glucose absorption, enabling postprandial glycaemia to be controlled with less demand on beta-cell insulin secretion. Clinical Trial Registration Number: NCT00688701; NCT00712673; NCT00713830; NCT00975286; NCT00715624; NCT00866658 Supported by: Sanofi