646 resultados para OWSC, CFD, OpenFOAM, WEC


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study is to identify the optimal designs of converging-diverging supersonic and hypersonic nozzles that perform at maximum uniformity of thermodynamic and flow-field properties with respect to their average values at the nozzle exit. Since this is a multi-objective design optimization problem, the design variables used are parameters defining the shape of the nozzle. This work presents how variation of such parameters can influence the nozzle exit flow non-uniformities. A Computational Fluid Dynamics (CFD) software package, ANSYS FLUENT, was used to simulate the compressible, viscous gas flow-field in forty nozzle shapes, including the heat transfer analysis. The results of two turbulence models, k-e and k-ω, were computed and compared. With the analysis results obtained, the Response Surface Methodology (RSM) was applied for the purpose of performing a multi-objective optimization. The optimization was performed with ModeFrontier software package using Kriging and Radial Basis Functions (RBF) response surfaces. Final Pareto optimal nozzle shapes were then analyzed with ANSYS FLUENT to confirm the accuracy of the optimization process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents a computational parametric analysis of DME steam reforming in a large scale Circulating Fluidized Bed (CFB) reactor. The Computational Fluid Dynamic (CFD) model used, which is based on Eulerian-Eulerian dispersed flow, has been developed and validated in Part I of this study [1]. The effect of the reactor inlet configuration, gas residence time, inlet temperature and steam to DME ratio on the overall reactor performance and products have all been investigated. The results have shown that the use of double sided solid feeding system remarkable improvement in the flow uniformity, but with limited effect on the reactions and products. The temperature has been found to play a dominant role in increasing the DME conversion and the hydrogen yield. According to the parametric analysis, it is recommended to run the CFB reactor at around 300 °C inlet temperature, 5.5 steam to DME molar ratio, 4 s gas residence time and 37,104 ml gcat -1 h-1 space velocity. At these conditions, the DME conversion and hydrogen molar concentration in the product gas were both found to be around 80%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An anastomosis is a surgical procedure that consists of the re-connection of two parts of an organ and is commonly required in cases of colorectal cancer. Approximately 80% of the patients diagnosed with this problem require surgery. The malignant tissue located on the gastrointestinal track must be resected and the most common procedure adopted is the anastomosis. Studies made with 2,980 patients that had this procedure, show that the leakage through the anastomosis was 5.1%. This paper discusses the dynamic behavior of N2O gas through different sized leakages as detected by an Infra-Red gas sensor and how the sensors response time changes depending on the leakage size. Different sized holes were made in the rigid tube to simulate an anastomostic leakage. N2O gas was injected into the tube through a pipe and the leakage rate measured by the infra-red gas sensor. Tests were also made experimentally also using a CFD (Computational Fluid Dynamics) package called FloWorks. The results will be compared and discussed in this paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Ph.D, Mechanical and Materials Engineering) -- Queen's University, 2016-08-31 09:37:50.239

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The wave energy industry is entering a new phase of pre-commercial and commercial deployments of full-scale devices, so better understanding of seaway variability is critical to the successful operation of devices. The response of Wave Energy Converters to incident waves govern their operational performance and for many devices, this is highly dependent on spectral shape due to their resonant properties. Various methods of wave measurement are presented, along with analysis techniques and empirical models. Resource assessments, device performance predictions and monitoring of operational devices will often be based on summary statistics and assume a standard spectral shape such as Pierson-Moskowitz or JONSWAP. Furthermore, these are typically derived from the closest available wave data, frequently separated from the site on scales in the order of 1km. Therefore, variability of seaways from standard spectral shapes and spatial inconsistency between the measurement point and the device site will cause inaccuracies in the performance assessment. This thesis categorises time and frequency domain analysis techniques that can be used to identify changes in a sea state from record to record. Device specific issues such as dimensional scaling of sea states and power output are discussed along with potential differences that arise in estimated and actual output power of a WEC due to spectral shape variation. This is investigated using measured data from various phases of device development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper presents an investigation of fix-referenced and self-referenced wave energy converters and a comparison of their corresponding wave energy conversion capacities from real seas. For conducting the comparisons, two popular wave energy converters, point absorber and oscillating water column, and their power conversion capacities in the fixed-referenced and self-referenced forms have been numerically studied and compared. In the numerical models, the deviceâ s power extractions from seas are maximized using the correspondingly optimized power take-offs in different sea states, thus their power conversion capacities can be calculated and compared. From the comparisons and analyses, it is shown that the energy conversion capacities of the self-referenced devices can be significantly increased if the motions of the device itself can be utilized for wave energy conversion; and the self-referenced devices can be possibly designed to be compliant in long waves, which could be a very beneficial factor for device survivability in the extreme wave conditions (normally long waves). In this regards, the self-referenced WECs (wave energy converters) may be better options in terms of wave energy conversion from the targeted waves in seas (frequently the most occurred), and in terms of the device survivability, especially in the extreme waves when compared to the fix-referenced counterparts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sweet potato is an important strategic agricultural crop grown in many countries around the world. The roots and aerial vine components of the crop are used for both human consumption and, to some extent as a cheap source of animal feed. In spite of its economic value and growing contribution to health and nutrition, harvested sweet potato roots and aerial vine components has limited shelf-life and is easily susceptible to post-harvest losses. Although post-harvest losses of both sweet potato roots and aerial vine components is significant, there is no information available that will support the design and development of appropriate storage and preservation systems. In this context, the present study was initiated to improve scientific knowledge about sweet potato post-harvest handling. Additionally, the study also seeks to develop a PV ventilated mud storehouse for storage of sweet potato roots under tropical conditions. In study one, airflow resistance of sweet potato aerial vine components was investigated. The influence of different operating parameters such as airflow rate, moisture content and bulk depth at different levels on airflow resistance was analyzed. All the operating parameters were observed to have significant (P < 0.01) effect on airflow resistance. Prediction models were developed and were found to adequately describe the experimental pressure drop data. In study two, the resistance of airflow through unwashed and clean sweet potato roots was investigated. The effect of sweet potato roots shape factor, surface roughness, orientation to airflow, and presence of soil fraction on airflow resistance was also assessed. The pressure drop through unwashed and clean sweet potato roots was observed to increase with higher airflow, bed depth, root grade composition, and presence of soil fraction. The physical properties of the roots were incorporated into a modified Ergun model and compared with a modified Shedd’s model. The modified Ergun model provided the best fit to the experimental data when compared with the modified Shedd’s model. In study three, the effect of sweet potato root size (medium and large), different air velocity and temperature on the cooling/or heating rate and time of individual sweet potato roots were investigated. Also, a simulation model which is based on the fundamental solution of the transient equations was proposed for estimating the cooling and heating time at the centre of sweet potato roots. The results showed that increasing air velocity during cooling and heating significantly (P < 0.05) affects the cooling and heating times. Furthermore, the cooling and heating times were significantly different (P < 0.05) among medium and large size sweet potato roots. Comparison of the simulation results with experimental data confirmed that the transient simulation model can be used to accurately estimate the cooling and heating times of whole sweet potato roots under forced convection conditions. In study four, the performance of charcoal evaporative cooling pad configurations for integration into sweet potato roots storage systems was investigated. The experiments were carried out at different levels of air velocity, water flow rates, and three pad configurations: single layer pad (SLP), double layers pad (DLP) and triple layers pad (TLP) made out of small and large size charcoal particles. The results showed that higher air velocity has tremendous effect on pressure drop. Increasing the water flow rate above the range tested had no practical benefits in terms of cooling. It was observed that DLP and TLD configurations with larger wet surface area for both types of pads provided high cooling efficiencies. In study five, CFD technique in the ANSYS Fluent software was used to simulate airflow distribution in a low-cost mud storehouse. By theoretically investigating different geometries of air inlet, plenum chamber, and outlet as well as its placement using ANSYS Fluent software, an acceptable geometry with uniform air distribution was selected and constructed. Experimental measurements validated the selected design. In study six, the performance of the developed PV ventilated system was investigated. Field measurements showed satisfactory results of the directly coupled PV ventilated system. Furthermore, the option of integrating a low-cost evaporative cooling system into the mud storage structure was also investigated. The results showed a reduction of ambient temperature inside the mud storehouse while relative humidity was enhanced. The ability of the developed storage system to provide and maintain airflow, temperature and relative humidity which are the key parameters for shelf-life extension of sweet potato roots highlight its ability to reduce post-harvest losses at the farmer level, particularly under tropical climate conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La compréhension de l'aérothermique d'un véhicule durant sa phase de développement est une question essentielle afin d'assurer, d'une part, un bon refroidissement et une bonne efficacité de ses composants et d'autre part de réduire la force de traînée et évidement le rejet des gaz à effet de serre ou la consommation d'essence. Cette thèse porte sur la simulation numérique et la validation expérimentale de l'aérothermique d'un véhicule à trois roues dont deux, en avant et une roue motrice en arrière. La simulation numérique est basée sur la résolution des équations de conservation de la masse, de la quantité de mouvement et de l'énergie en utilisant l'approche RANS (Reynolds-Averaged Navier-Stokes). Le rayonnement thermique est modélisé grâce à la méthode S2S (Surface to Surface) qui suppose que le milieu séparant les deux surfaces rayonnantes, ici de l'air, ne participe pas au processus du rayonnement. Les radiateurs sont considérés comme des milieux poreux orthotropes où la perte de pression est calculée en fonction de leurs propriétés inertielle et visqueuse; leur dissipation thermique est modélisée par la méthode Dual flow. Une première validation de l'aérodynamique est faite grâce à des essais en soufflerie. Ensuite, une deuxième validation de la thermique est faite grâce à des essais routiers. Un deuxième objectif de la thèse est consacré à la simulation numérique de l'aérodynamique en régime transitoire du véhicule. La simulation est faite à l'aide de l'approche Detached eddy simulation (DES). Une validation expérimentale est faite à partir d'étude en soufflerie grâce à des mesures locales de vitesse à l'aide de sondes cobra.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract : Recently, there is a great interest to study the flow characteristics of suspensions in different environmental and industrial applications, such as snow avalanches, debris flows, hydrotransport systems, and material casting processes. Regarding rheological aspects, the majority of these suspensions, such as fresh concrete, behave mostly as non-Newtonian fluids. Concrete is the most widely used construction material in the world. Due to the limitations that exist in terms of workability and formwork filling abilities of normal concrete, a new class of concrete that is able to flow under its own weight, especially through narrow gaps in the congested areas of the formwork was developed. Accordingly, self-consolidating concrete (SCC) is a novel construction material that is gaining market acceptance in various applications. Higher fluidity characteristics of SCC enable it to be used in a number of special applications, such as densely reinforced sections. However, higher flowability of SCC makes it more sensitive to segregation of coarse particles during flow (i.e., dynamic segregation) and thereafter at rest (i.e., static segregation). Dynamic segregation can increase when SCC flows over a long distance or in the presence of obstacles. Therefore, there is always a need to establish a trade-off between the flowability, passing ability, and stability properties of SCC suspensions. This should be taken into consideration to design the casting process and the mixture proportioning of SCC. This is called “workability design” of SCC. An efficient and non-expensive workability design approach consists of the prediction and optimization of the workability of the concrete mixtures for the selected construction processes, such as transportation, pumping, casting, compaction, and finishing. Indeed, the mixture proportioning of SCC should ensure the construction quality demands, such as demanded levels of flowability, passing ability, filling ability, and stability (dynamic and static). This is necessary to develop some theoretical tools to assess under what conditions the construction quality demands are satisfied. Accordingly, this thesis is dedicated to carry out analytical and numerical simulations to predict flow performance of SCC under different casting processes, such as pumping and tremie applications, or casting using buckets. The L-Box and T-Box set-ups can evaluate flow performance properties of SCC (e.g., flowability, passing ability, filling ability, shear-induced and gravitational dynamic segregation) in casting process of wall and beam elements. The specific objective of the study consists of relating numerical results of flow simulation of SCC in L-Box and T-Box test set-ups, reported in this thesis, to the flow performance properties of SCC during casting. Accordingly, the SCC is modeled as a heterogeneous material. Furthermore, an analytical model is proposed to predict flow performance of SCC in L-Box set-up using the Dam Break Theory. On the other hand, results of the numerical simulation of SCC casting in a reinforced beam are verified by experimental free surface profiles. The results of numerical simulations of SCC casting (modeled as a single homogeneous fluid), are used to determine the critical zones corresponding to the higher risks of segregation and blocking. The effects of rheological parameters, density, particle contents, distribution of reinforcing bars, and particle-bar interactions on flow performance of SCC are evaluated using CFD simulations of SCC flow in L-Box and T-box test set-ups (modeled as a heterogeneous material). Two new approaches are proposed to classify the SCC mixtures based on filling ability and performability properties, as a contribution of flowability, passing ability, and dynamic stability of SCC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La tuberculosis TB es una de las principales causas de muerte en el mundo en individuos con infección por VIH. En Colombia esta coinfección soporta una carga importante en la población general convirtiéndose en un problema de salud pública. En estos pacientes las pruebas diagnósticas tienen sensibilidad inferior y la enfermedad evoluciona con mayor frecuencia hacia formas diseminadas y rápidamente progresivas y su diagnóstico oportuno representa un reto en Salud. El objetivo de este proyecto es evaluar el desempeño de las pruebas diagnósticas convencionales y moleculares, para la detección de TB latente y activa pacientes con VIH, en dos hospitales públicos de Bogotá. Para TB latente se evaluó la concordancia entre las pruebas QuantiFERON-TB (QTF) y Tuberculina (PPD), sugiriendo superioridad del QTF sobre la PPD. Se evaluaron tres pruebas diagnósticas por su sensibilidad y especificidad, baciloscopia (BK), GenoType®MTBDR plus (Genotype) y PCR IS6110 teniendo como estándar de oro el cultivo. Los resultados de sensibilidad (S) y especificidad (E) de cada prueba con una prevalencia del 19,4 % de TB pulmonar y extrapulmonar en los pacientes que participaron del estudio fue: BK S: 64% E: 99,1%; Genotype S: 77,8% E: 94,5%; PCRIS6110 S: 73% E: 95,5%, de la misma forma se determinaron los valores predictivos positivos y negativos (VPP y VPN) BK: 88,9% y 94,8%, Genotype S: 77,8% E: 94,5%; PCRIS6110 S: 90% y 95,7%. Se concluyó bajo análisis de curva ROC que las pruebas muestran un rendimiento diagnóstico similar por separado en el diagnóstico de TB en pacientes con VIH, aumentando su rendimiento diagnostico cuando se combinan

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluids are important because of their preponderance in our lives. Fluid mechanics touches almost every aspect of our daily lives, and it plays a central role in many branches of science and technology. Therefore, it is a challenging and exciting field of scientific activity due to the complexity of the subject studied and the breadth of the applications. The quest for advances in fluid mechanics, as in other scientific fields, emerge from analytical, computational (CFD) and experimental studies. The improvement in our ability to describe, predict and control the phenomena played (and plays) key roles in the technological breakthroughs. The present theme issue of “Fluid and Heat Flow: Simulation and Optimization” collects a selection of papers. selection of papers presented at Special Session “Fluid Flow, Energy Transfer and Design”

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il presente lavoro di tesi vuole focalizzare l’attenzione sull’impiego del GNL per la propulsione navale, analizzando aspetti legati alla sicurezza delle infrastrutture necessarie a tale scopo. Si sono considerati due diversi casi di studio: il primo riguarda un deposito costiero attrezzato per poter svolgere attività di rifornimento per imbarcazioni, mentre il secondo caso interessa una nave da trasporto passeggeri alimentata a GNL. È stata condotta un’analisi del rischio: l’identificazione dei pericoli ha seguito le linee guida proposte dalla metodologia MIMAH, oltre a sfruttare risultati di analisi HAZOP e HAZID. La stima delle frequenze di rilascio è stata effettuata con la tecnica della parts count, sulla base di valori ottenuti da database affidabilistici. La valutazione delle conseguenze è stata realizzata con il supporto del software DNV PHAST, utilizzando come riferimento i valori soglia proposti dal D.M. 9/5/2001. È stata infine impostata una modellazione fluidodinamica con lo scopo di valutare la possibilità di rottura catastrofica dei serbatoi di stoccaggio dovuta ad un’eccessiva pressurizzazione causata da una situazione di incendio esterno. Le simulazioni sono state condotte con il supporto del software CFD ANSYS® FLUENT® 17.2. Si è modellata una situazione di completo avvolgimento dalle fiamme considerando due geometrie di serbatoio diverse, nel caso di materiale isolante integro o danneggiato. I risultati ottenuti dall’analisi del rischio mostrano come i danni derivanti da un ipotetico scenario incidentale possano avere conseguenze anche significative, ma con valori di frequenze di accadimento tipici di situazioni rare. Lo studio fluidodinamico del comportamento di serbatoi di stoccaggio avvolti dalle fiamme ha evidenziato come questi siano capaci di resistere a condizioni gravose di incendio per tempi prolungati senza che si abbia una pressurizzazione tale da destare preoccupazione per l’integrità strutturale delle apparecchiature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nel panorama mondiale di contenimento delle emissioni inquinanti in atmosfera é divenuto sempre più importante limitare la parte derivante dai motori a combustione interna: l'utilizzo di motori GDI a carica stratificata e di ricircolo dei gas di scarico (EGR) sono esempi di tecnologie pensate proprio in tale ottica. Sia la presenza di un ambiente magro che di EGR nel cilindro, come anche l'aumento della pressione nel cilindro per l'incremento della pressione di sovralimentazione o del rapporto di compressione, hanno lo svantaggio di limitare la velocità di combustione e rendere più sfavorevoli le condizioni di accensione della miscela; in questo scenario diviene di fondamentale importanza il miglioramento dei sistemi di accensione, la creazione di modelli volti a simularli e la comprensione dei fenomeni che ne stanno alla base. Il seguente lavoro di tesi si inserisce proprio in questo contesto, indagando le varie fasi di cui si compone il fenomeno dell'accensione e le relazioni che legano le variabili di interesse fisico, verificate sulla base di evidenze sperimentali. Successivamente vengono analizzati i principali modelli d'accensione che sono stati proposti e implementati in codici computazionali fluidodinamici; l'analisi mette in luce le differenze, i punti di forza e le semplificazioni introdotte in ognuno di essi, in modo da poterli valutare criticamente. La suddetta analisi é anche utile per introdurre il modello frutto del lavoro del gruppo di ricerca dell'Università di Bologna; ci si concentra particolarmente su quest'ultimo poiché un obiettivo di questo lavoro di tesi é stato proprio l'implementazione e l'utilizzo del modello in un codice fluidodinamico tridimensionale quale CONVERGE CFD. L'implementazione é stata poi validata attraverso simulazioni su una geometria reale di un motore a combustione interna ad elevate prestazioni, confrontando i risultati ottenuti con il nuovo modello rispetto ai dati sperimentali sulla combustione.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La seguente tesi nasce dall’esigenza di ottimizzare, da un punto di vista acustico e prestazionale, un ventilatore centrifugo preesistente in azienda. Nei primi tre capitoli si è analizzato il problema da un punto di vista teorico, mentre nel terzo e quarto capitolo da un punto di vista computazionale sfruttando tecniche CFD. Nel primo capitolo è stata fatta una trattazione generale dei ventilatori centrifughi, concentrandosi sul tipo di problematiche a cui questi vanno incontro. Nel secondo capitolo è stata presentata la teoria che sta alla base di una rilevazione sperimentale e di un’analisi acustica. Unitamente a ciò sono stati riportati alcuni articoli che mostrano tecniche di ottimizzazione acustica in ventilatori centrifughi. Nel terzo capitolo è stata riassunta la teoria alla base della fluidodinamica e di uno studio fluidodinamico. Nel quarto capitolo viene spiegato come è stato creato il modello fluidodinamico. Si è optato per un’analisi del problema in stato stazionario, sfruttando il Moving Reference Frame, e considerando l’aria come incomprimibile, visto il ridotto numero di Mach. L’analisi acustica è stata effettuata nel post-processing sfruttando il modello di Proudman. Infine è stata dimostrata la correlazione che intercorre tra i tre punti della curva resistente del ventilatore di funzionamento reale, permettendo di estendere i risultati ricavati dalla analisi di uno di questi agli altri due. Nel quinto capitolo è stata effettuata un’analisi dei risultati ottenuti dalle simulazioni fluidodinamiche e sono state proposte diverse modifiche della geometria. La modifica scelta ha visto un miglioramento delle prestazioni e una minore rumorosità. Infine sono state proposte nelle conclusioni ulteriori possibili strade da percorre per un’indagine e ottimizzazione del ventilatore più accurata.