946 resultados para Non invasive methods


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: With the potential to address evaporative dry eye, a novel spray has been developed in which phospholipid liposomes are delivered to the tear film via the surface of the closed eyelid. This study evaluated the short-term effects of liposomal spray application on the lipid and stability characteristics of the pre-ocular tear film in normal eyes. Methods: Twenty-two subjects (12M, 10F) aged 35.1 ± 7.1 years participated in this prospective, randomised, double-masked investigation in which the liposomal spray was applied to one eye, and an equal volume of saline spray (control) applied to the contralateral eye. Lipid layer grade (LLG), non-invasive tear film stability (NIBUT) and tear meniscus height (TMH) were evaluated at baseline, and at 30, 60, 90 and 135 minutes post-application. Subjective reports of comfort were also compared. Results: Treated and control eyes were not significantly different at baseline (p>0.05). Post-application, LLG increased significantly, at 30 and 60 minutes, only in the treated eyes (p=0.005). NIBUT also increased significantly in the treated eyes only (p<0.001), at 30, 60 and 90 minutes. TMH did not alter significantly (p>0.05). Comfort improved relative to baseline in 46% of treated and 18% of control eyes, respectively, at 30 minutes post-application. Of those expressing a preference in comfort between the eyes, 68% preferred the liposomal spray. Conclusions: Consistent with subjective reports of improved comfort, statistically and clinically significant improvements in lipid layer thickness and tear film stability are observed in normal eyes for at least an hour after a single application of a phospholipid liposomal spray.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Much research is currently centred on the detection of damage in structures using vibrational data. The work presented here examined several areas of interest in support of a practical technique for identifying and locating damage within bridge structures using apparent changes in their vibrational response to known excitation. The proposed goals of such a technique included the need for the measurement system to be operated on site by a minimum number of staff and that the procedure should be as non-invasive to the bridge traffic-flow as possible. Initially the research investigated changes in the vibrational bending characteristics of two series of large-scale model bridge-beams in the laboratory and these included ordinary-reinforced and post-tensioned, prestressed designs. Each beam was progressively damaged at predetermined positions and its vibrational response to impact excitation was analysed. For the load-regime utilised the results suggested that the infuced damage manifested itself as a function of the span of a beam rather than a localised area. A power-law relating apparent damage with the applied loading and prestress levels was then proposed, together with a qualitative vibrational measure of structural damage. In parallel with the laboratory experiments a series of tests were undertaken at the sites of a number of highway bridges. The bridges selected had differing types of construction and geometric design including composite-concrete, concrete slab-and-beam, concrete-slab with supporting steel-troughing constructions together with regular-rectangular, skewed and heavily-skewed geometries. Initial investigations were made of the feasibility and reliability of various methods of structure excitation including traffic and impulse methods. It was found that localised impact using a sledge-hammer was ideal for the purposes of this work and that a cartridge `bolt-gun' could be used in some specific cases.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This thesis documents the design, manufacture and testing of a passive and non-invasive micro-scale planar particle-from-fluid filter for segregating cell types from a homogeneous suspension. The microfluidics system can be used to separate spermatogenic cells from testis biopsy samples, providing a mechanism for filtrate retrieval for assisted reproduction therapy. The system can also be used for point-of-service diagnostics applications for hospitals, lab-on-a-chip pre-processing and field applications such as clinical testing in the third world. Various design concepts are developed and manufactured, and are assessed based on etched structure morphology, robustness to variations in the manufacturing process, and design impacts on fluid flow and particle separation characteristics. Segregation was measured using image processing algorithms that demonstrate efficiency is more than 55% for 1 µl volumes at populations exceeding 1 x 107. the technique supports a significant reduction in time over conventional processing, in the separation and identification of particle groups, offering a potential reduction in the associated cost of the targeted procedure. The thesis has developed a model of quasi-steady wetting flow within the micro channel and identifies the forces across the system during post-wetting equalisation. The model and its underlying assumptions are validated empirically in microfabricated test structures through a novel Micro-Particle Image Velocimetry technique. The prototype devices do not require ancillary equipment nor additional filtration media, and therefore offer fewer opportunities for sample contamination over conventional processing methods. The devices are disposable with minimal reagent volumes and process waste. Optimal processing parameters and production methods are identified with any improvements that could be made to enhance their performance in a number of identified potential applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Azidoprofen {2-(4-azidophenyl)propionic acid; AZP}, an azido-substituted arylalkanoic acid, was investigated as a model soft drug candidate for a potential topical non-steroidal anti-inflammatory agent (NSAIA). Reversed-phase high performance liquid chromatography (HPLC) methods were developed for the assay of AZP, a series of ester analogues and their· degradation products. 1H-NMR spectroscopy was also employed as an analytical method in selected cases. Reduction of the azido-group to the corresponding amine has been proposed as a potential detoxification mechanism for compounds bearing this substituent. An in vitro assay to measure the susceptibility of azides towards reduction was developed using dithiothreitol as a model reducing agent. The rate of reduction of AZP was found to be base-dependent, hence supporting the postulated mechanism of thiol-mediated reduction via nucleophilic attack by the thiolate anion. Prodrugs may enhance topical bioavailability through the manipulation of physico-chemical properties of the parent drug. A series of ester derivatives of AZP were investigated for their susceptibility to chemical and enzymatic hydrolysis, which regenerates the parent acid. Use of alcoholic cosolvents with differing alkyl functions to that of the ester resulted in transesterification reactions, which were found to be enzyme-mediated. The skin penetration of AZP was assessed using an in vitro hairless mouse skin model, and silastic membrane in some cases. The rate of permeation of AZP was found to be a similar magnitude to that of the well established NSAIA ibuprofen. Penetration rates were dependent on the vehicle pH and drug concentration when solutions were employed. In contrast, flux was independent of pH when suspension formulations were used. Pretreatment of the skin with various enhancer regimes, including oleic acid and azone in propylene glycol, promoted the penetration of AZP. An intense IR absorption due to the azide group serves as a highly diagnostic marker, enabling azido compounds to be detected in the outer layers of the· stratum corneum following their application to skin, using attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR). This novel application enabled a non-invasive examination of the percutaneous penetration enhancement of a model azido compound in vivo in man, in the presence of the enhancer oleic acid.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The Nidek F-10 is a scanning laser ophthalmoscope that is capable of a novel fundus imaging technique, so-called ‘retro-mode’ imaging. The standard method of imaging drusen in age-related macular degeneration (AMD) is by fundus photography. The aim of the study was to assess drusen quantification using retro-mode imaging. Methods: Stereoscopic fundus photographs and retro-mode images were captured in 31 eyes of 20 patients with varying stages of AMD. Two experienced masked retinal graders independently assessed images for the number and size of drusen, using purpose-designed software. Drusen were further assessed in a subset of eight patients using optical coherence tomography (OCT) imaging. Results: Drusen observed by fundus photography (mean 33.5) were significantly fewer in number than subretinal deposits seen in retro-mode (mean 81.6; p < 0.001). The predominant deposit diameter was on average 5 µm smaller in retro-mode imaging than in fundus photography (p = 0.004). Agreement between graders for both types of imaging was substantial for number of deposits (weighted ? = 0.69) and moderate for size of deposits (weighted ? = 0.42). Retro-mode deposits corresponded to drusen on OCT imaging in all eight patients. Conclusion: The subretinal deposits detected by retro-mode imaging were consistent with the appearance of drusen on OCT imaging; however, a larger longitudinal study would be required to confirm this finding. Retro-mode imaging detected significantly more deposits than conventional colour fundus photography. Retro-mode imaging provides a rapid non-invasive technique, useful in monitoring subtle changes and progression of AMD, which may be useful in monitoring the response of drusen to future therapeutic interventions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Diabetic retinopathy (DR) remains the leading cause of blindness among working-age individuals in developed countries. Current treatments for DR are indicated in advanced stages of the disease and are associated with significant adverse effects. Therefore, new pharmacological treatments for the early stages of DR are needed. DR has been classically considered to be a microcirculatory disease of the retina. However, there is growing evidence to suggest that retinal neurodegeneration is an early event in the pathogenesis of DR, which participates in the microcirculatory abnormalities that occur in DR. Therefore, the study of the underlying mechanisms that lead to neurodegeneration will be essential for identifying new therapeutic targets. From the clinical point of view, the identification of those patients in whom retinal neurodegeneration appears will be crucial for implementing early treatment based on neuroprotective drugs. When the early stages of DR are the therapeutic target, it would be inconceivable to recommend an aggressive treatment such as intravitreous injections. By contrast, topical administration of neuroprotective drugs by using eye drops is a possible option. However, clinical trials to determine the safety and effectiveness of this non-invasive route, as well as a standardisation of the methods for monitoring neurodegeneration, are needed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To investigate the dynamics of communication within the primary somatosensory neuronal network. Methods: Multichannel EEG responses evoked by median nerve stimulation were recorded from six healthy participants. We investigated the directional connectivity of the evoked responses by assessing the Partial Directed Coherence (PDC) among five neuronal nodes (brainstem, thalamus and three in the primary sensorimotor cortex), which had been identified by using the Functional Source Separation (FSS) algorithm. We analyzed directional connectivity separately in the low (1-200. Hz, LF) and high (450-750. Hz, HF) frequency ranges. Results: LF forward connectivity showed peaks at 16, 20, 30 and 50. ms post-stimulus. An estimate of the strength of connectivity was modulated by feedback involving cortical and subcortical nodes. In HF, forward connectivity showed peaks at 20, 30 and 50. ms, with no apparent feedback-related strength changes. Conclusions: In this first non-invasive study in humans, we documented directional connectivity across subcortical and cortical somatosensory pathway, discriminating transmission properties within LF and HF ranges. Significance: The combined use of FSS and PDC in a simple protocol such as median nerve stimulation sheds light on how high and low frequency components of the somatosensory evoked response are functionally interrelated in sustaining somatosensory perception in healthy individuals. Thus, these components may potentially be explored as biomarkers of pathological conditions. © 2012 International Federation of Clinical Neurophysiology.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper analyses the effect of corruption on Multinational Enterprises' (MNEs) incentives to undertake FDI in a particular country. We contribute to the existing literature by modelling the relationship between corruption and FDI using both parametric and non-parametric methods. We report that the impact of corruption on FDI stock is different for the different quantiles of the FDI stock distribution. This is a characteristic that could not be captured in previous studies which used only parametric methods. After controlling for the location selection process of MNEs and other host country characteristics, the result from both parametric and non-parametric analyses offer some support for the ‘helping-hand’ role of corruption.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: to evaluate changes in tear metrics and ocular signs induced by six months of silicone-hydrogel contact lens wear and the difference in baseline characteristics between those who successfully continued in contact lens wear compared to those that did not. Methods: Non-invasive Keratograph, Tearscope and fluorescein tear break-up times (TBUTs), tear meniscus height, bulbar and limbal hyperaemia, lid-parallel conjunctival folds (LIPCOF), phenol red thread, fluorescein and lissamine-green staining, and lid wiper epitheliopathy were measured on 60 new contact lens wearers fitted with monthly silicone-hydrogels (average age 36 ± 14 years, 40 females). Symptoms were evaluated by the Ocular Surface Disease Index (OSDI). After six months full time contact lens wear the above metrics were re-measured on those patients still in contact lens wear (n= 33). The initial measurements were also compared between the group still wearing lenses after six months and those who had ceased lens wear (n= 27). Results: There were significant changes in tear meniscus height (p= 0.031), bulbar hyperaemia (p= 0.011), fluorescein TBUT (p= 0.027), corneal (p= 0.007) and conjunctival (p= 0.009) staining, LIPCOF (p= 0.011) and lid wiper epitheliopathy (p= 0.002) after six months of silicone-hydrogel wear. Successful wearers had a higher non-invasive (17.0 ± 8.2. s vs 12.0 ± 5.6. s; p= 0.001) and fluorescein (10.7 ± 6.4. s vs 7.5 ± 4.7. s; p= 0.001) TBUT than drop-outs, although OSDI (cut-off 4.2) was also a strong predictor of success. Conclusion: Silicone-hydrogel lenses induced significant changes in the tear film and ocular surface as well as lid margin staining. Wettability of the ocular surface is the main factor affecting contact lens drop-out. © 2013 British Contact Lens Association.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

To investigate if Magnetoencephalography (MEG) can add non-redundant information to guide implantation sites for intracranial recordings (IR). The contribution of MEG to intracranial recording planning was evaluated in 12 consecutive patients assessed pre-surgically with MEG followed by IR. Primary outcome measures were the identification of focal seizure onset in IR and favorable surgical outcome. Outcome measures were compared to those of 12 patients matched for implantation type in whom non-invasive pre-surgical assessment suggested clear hypotheses for implantation (non-MEG group). In the MEG group, non-invasive assessment without MEG was inconclusive, and MEG was then used to further help identify implantation sites. In all MEG patients, at least one virtual MEG electrode generated suitable hypotheses for the location of implantations. No differences in outcome measures were found between non-MEG and MEG groups. Although the MEG group included more complex patients, it showed similar percentage of successful implantations as the non-MEG group. This suggests that MEG can contribute to identify implantation sites where standard methods failed. © 2013 Springer Science+Business Media New York.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Polyvinyl alcohol (PVA) is a successful tear film stabiliser and is widely used in comfort drops and some soft contact lens materials. A PVA-containing lens, nelfilcon A has been modified to include additional (non-functional) PVA in order to provide improved comfort. This study aims to examine the clinical performance of this nelfilcon A lens with AquaRelease™ (AquaRelease). Methods: Two contralateral, investigator masked, open label, subjective and objective evaluations were conducted. The first examined the effect of adding increased molecular weight PVA to nelfilcon A (n = 5), and the second compared this AquaRelease lens to ocufilcon B (n = 34). The principal measures were non-invasive break-up time (NIBUT) and subjective comfort, which were assessed at the beginning and end of a week of daily wear, and three times throughout 1 day at 8, 12 and 16 h. Results: All subjects successfully completed the daily wearing schedule of 16 h. On initial insertion, subjective comfort and NIBUT improved for AquaRelease than original nelfilcon A lenses (p < 0.05). Initial comfort was better for AquaRelease compared to ocufilcon B lenses (p = 0.01); however, NIBUT was not statistically different (11.7 ± 15.6 s versus 8.4 ± 6.8 s; p = 0.26). Subjective comfort decreased with time (p < 0.001), but there was no significant difference between AquaRelease and ocufilcon B lenses (p = 0.16). NIBUT was not significantly affected by time (p = 0.56) or between lenses (p = 0.33). At the end of a weeks' wear, subjective initial, end-of-day, overall comfort and vision were rated significantly better with AquaRelease than ocufilcon B (p < 0.01). Conclusions: Release of additional non-functionalised PVA from the nelfilcon A lenses appears to enhance comfortable contact lens wear. © 2006 British Contact Lens Association.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose - To generate a reflectance model of the fundus that allows an accurate non-invasive quantification of blood and pigments. Methods - A Monte Carlo simulation was used to produce a mathematical model of light interaction with the fundus at different wavelengths. The model predictions were compared with fundus images from normal volunteers in several spectral bands (peaks at 507, 525, 552, 585, 596 and 611nm). Th e model was then used to calculate the concentration and distribution of the known absorbing components of the fundus. Results - The shape of the statistical distribution of the image data generally corresponded to that of the model data; the model however appears to overestimate the reflectance of the fundus in the longer wavelength region.As the absorption by xanthophyll has no significant eff ect on light transport above 534nm, its distribution in the fundus was quantified: the wavelengths where both shape and distribution of image and model data matched (<553nm) were used to train a neural network which was then applied to every point in the image data. The xanthophyll distribution thus found was in agreement with published literature data in normal subjects. Conclusion - We have developed a method for optimising multi-spectral imaging of the fundus and a computer image analysis capable of estimating information about the structure and properties of the fundus. Th e technique successfully calculates the distribution of xanthophyll in the fundus of healthy volunteers. Further improvement of the model is required to allow the deduction of other parameters from images; investigations in known pathology models are also necessary to establish if this method is of clinical use in detecting early chroido-retinopathies, hence providing a useful screening and diagnostic tool.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Methods: Thirty-nine subjects (22.1. ±. 3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16. h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Results: Lens fit assessments were not different between brands (P > 0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12. h (P <. 0.05), but remained stable from 12 to 16. h (P > 0.05). Movement-on-blink was unaffected by wear-time (F = 0.403, P = 0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r = -0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P > 0.01). Conclusions: Among the lenses tested, objective lens fit changed between 8. h and 12. h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Remote, non-invasive and objective tests that can be used to support expert diagnosis for Parkinson's disease (PD) are lacking. Methods: Participants underwent baseline in-clinic assessments, including the Unified Parkinson's Disease Rating Scale (UPDRS), and were provided smartphones with an Android operating system that contained a smartphone application that assessed voice, posture, gait, finger tapping, and response time. Participants then took the smart phones home to perform the five tasks four times a day for a month. Once a week participants had a remote (telemedicine) visit with a Parkinson disease specialist in which a modified (excluding assessments of rigidity and balance) UPDRS performed. Using statistical analyses of the five tasks recorded using the smartphone from 10 individuals with PD and 10 controls, we sought to: (1) discriminate whether the participant had PD and (2) predict the modified motor portion of the UPDRS. Results: Twenty participants performed an average of 2.7 tests per day (68.9% adherence) for the study duration (average of 34.4 days) in a home and community setting. The analyses of the five tasks differed between those with Parkinson disease and those without. In discriminating participants with PD from controls, the mean sensitivity was 96.2% (SD 2%) and mean specificity was 96.9% (SD 1.9%). The mean error in predicting the modified motor component of the UPDRS (range 11-34) was 1.26 UPDRS points (SD 0.16). Conclusion: Measuring PD symptoms via a smartphone is feasible and has potential value as a diagnostic support tool.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To test the practicality and effectiveness of cheap, ubiquitous, consumer-grade smartphones to discriminate Parkinson’s disease (PD) subjects from healthy controls, using self-administered tests of gait and postural sway. Background: Existing tests for the diagnosis of PD are based on subjective neurological examinations, performed in-clinic. Objective movement symptom severity data, collected using widely-accessible technologies such as smartphones, would enable the remote characterization of PD symptoms based on self-administered, behavioral tests. Smartphones, when backed up by interviews using web-based videoconferencing, could make it feasible for expert neurologists to perform diagnostic testing on large numbers of individuals at low cost. However, to date, the compliance rate of testing using smart-phones has not been assessed. Methods: We conducted a one-month controlled study with twenty participants, comprising 10 PD subjects and 10 controls. All participants were provided identical LG Optimus S smartphones, capable of recording tri-axial acceleration. Using these smartphones, patients conducted self-administered, short (less than 5 minute) controlled gait and postural sway tests. We analyzed a wide range of summary measures of gait and postural sway from the accelerometry data. Using statistical machine learning techniques, we identified discriminating patterns in the summary measures in order to distinguish PD subjects from controls. Results: Compliance was high all 20 participants performed an average of 3.1 tests per day for the duration of the study. Using this test data, we demonstrated cross-validated sensitivity of 98% and specificity of 98% in discriminating PD subjects from healthy controls. Conclusions: Using consumer-grade smartphone accelerometers, it is possible to distinguish PD from healthy controls with high accuracy. Since these smartphones are inexpensive (around $30 each) and easily available, and the tests are highly non-invasive and objective, we envisage that this kind of smartphone-based testing could radically increase the reach and effectiveness of experts in diagnosing PD.