987 resultados para NONPLANAR DISTORTION


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dispersion compensation characteristics of the chirped fiber grating (CFG) for different dispersion compensation positions are analyzed in externally modulated cable television (CATV) lightwave system and the analytic expression of the composite second order (CSO) distortion is derived. The analyses give a reasonable explanation for the position-dependent effect of CFG dispersion compensator, which was found in practical systems. Moreover, the theoretical result is also verified by an experiment. It is believed that the theory will be helpful in designing optical CATV fiber links with nodes at proper positions both for intensity amplification and dispersion compensation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis is a study of nonlinear phenomena in the propagation of electromagnetic waves in a weakly ionized gas externally biased with a magnetostatic field. The present study is restricted to the nonlinear phenomena rising from the interaction of electromagnetic waves in the ionized gas. The important effects of nonlinearity are wave-form distortion leads to cross modulation of one wave by a second amplitude-modulated wave.

The nonlinear effects are assumed to be small so that a perturbation method can be used. Boltzmann’s kinetic equation with an appropriate expression for the collision term is solved by expanding the electron distribution function into spherical harmonics in velocity space. In turn, the electron convection current density and the conductivity tensors of the nonlinear ionized gas are found from the distribution function. Finally, the expression for the current density and Maxwell’s equations are employed to investigate the effects of nonlinearity on the propagation of electromagnetic waves in the ionized gas, and also on the reflection of waves from an ionized gas of semi-infinite extent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tratamento restaurador atraumático tornou-se uma opção real para o tratamento da cárie dentária em saúde pública no Brasil. O presente estudo teve como objetivo avaliar durabilidade, resistência e eficácia de 70 restaurações em 31 alunos (entre 6 a 12 anos de idade na Escola Municipal Rotary, RJ - Brasil). Depois de CPO-D e ceo-exame de acordo com critérios da OMS, todos os alunos com selecionados receberam TRA com VITRO MOLAR - DFL, juntamente com instruções de saúde bucal. Os critérios de exclusão foram a presença de cavidades muito profundas e exposição pulpar, casos em que os alunos foram encaminhados para o Postos de Saúde Municipal. In vitro avaliou-se a influência do tempo de entrada em serviço e do tipo de cobertura protetora utilizada na resistência coesiva do Cimento de Ionômero de Vidro utilizado, por meio de ensaios de tração diametral. Confeccionou-se para o teste de tração diametral 6 espécimes para cada variante, 72 no total, com dimensões de 4 mm de diâmetro por 8 mm de comprimento, divididos entre os grupos: grupo1 sem protetor (controle); grupo2 vaselina sólida; grupo3 verniz para unhas. Realizou-se ensaios mecânicos em uma máquina universal de ensaios EMIC DL 500 MF, após a confecção e estocagem individual dos espécimes em potes plásticos contendo 5 ml de água deionizada, que formaram os subgrupos descritos a seguir: a - 20 minutos; b - 2 horas; c - 24 horas; d - 7 dias. Os dados obtidos foram tratados por ANOVA e por Student Newman-Keuls (p<0,05). Ao se avaliar a influência dos diferentes protetores de superfície no CIV utilizado no presente trabalho observou-se que, os protetores de superfície tiveram influência no comportamento do material (p=0,000), com o verniz para unhas mostrando um desempenho superior ao da vaselina sólida. Quanto ao tempo, não foi possível verificar ruptura do material no prazo de 20 minutos, pois os corpos de prova sofriam deformação elástica catastrófica não sendo adequado para a finalidade desejada. Os tempos de 24 horas e sete dias foram semelhantes entre si e diferentes do tempo de duas horas. As restaurações foram clinicamente avaliadas depois de 6, 12, e 24 meses após sua alocação. No total 72 restaurações foram realizadas em 31 escolares. Depois de seis meses, 5 restaurações fraturaram e 3 perderam algum material. Após 12 meses, oito restaurações foram perdidas e apenas 1 fraturou. Na avaliação após 24 meses, mais 12 restaurações foram perdidas e 3 perderam material. Não foram registradas lesões cariosas secundarias após esse período, mesmo quando as restaurações foram parcialmente perdidas. Clinicamente conclui-se que quando a técnica do TRA é bem indicada e aplicada corretamente pode haver uma redução significativa no número de dentes perdidos por lesões de cárie nos indivíduos que participaram do nosso estudo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Presented in the first part of this thesis is work performed on the ionizing energy beam induced adhesion enhancement of thin (~ 500 Angstrom) Au films on GaAs substrates. The ionizing beam, employed in the present thesis, is the MeV ions (i.e., 16O, 19F, and 35Cl), with energies between 1 and 20 MeV. Using the "Scratch" test for adhesion measurement, and ESCA for chemical analysis of the film-substrate interface, the native oxide layer at the interface is shown to play an important role in the adhesion enhancement by the ionizing radiation. A model is discussed which explains the experimental data on the the dependence of adhesion enhancement on the energy which was deposited into electronic processes at the interface. The ESCA data indicate that the chemical bonds (or compounds), which are responsible for the increase in the thin film adherence, are hydroxides rather than oxides.

In the second part of the thesis we present a research performed on the radiation damage in GaAs crystals produced by MeV ions. Lattice parameter dilatation in the surface layers of the GaAs crystals becomes saturated after a high dose bombardment at room temperature. The strain produced by nuclear collisions is shown to relax partially due to electronic excitation (with a functional dependence on the nuclear and electronic stopping power of bombarding ions). Data on the GaAs and GaP crystals suggest that low temperature recovery stage defects produce major crystal distortion. The x-ray rocking curve technique with a dynamical diffraction theory analysis provides the depth distribution of the strain and damage in the MeV ion bombarded crystals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

理论分析和讨论了基于频域相位共轭技术的交叉相位调制所致信号失真的复原和补偿机理,数值模拟了在交叉相位调制作用下,高斯脉冲在中距相位共轭光纤系统中的传输演化过程.结果表明,频域相位共轭技术能够抑制交叉相位调制对光纤系统中传输信号的损害,复原其所导致的信号失真,并能够同步补偿群速度色散和自相位调制非线性效应所导致的信号失真.合适的初始脉冲时延和初始脉冲啁啾有利于频域相位共轭技术对交叉相位调制所致信号失真的抑制.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

光学相位共轭(OPC)技术能够同时且高效地补偿光纤传输过程中色散及非线性效应所导致的信号失真,且该技术同脉冲调制方式无关。从理论上分析了在自陡峭效应(SS)作用下高斯脉冲信号在中距相位共轭系统中的传输演化特性,数值模拟了在其作用下超短飞秒高斯脉冲的动态传输过程,讨论了自陡峭效应对中距相位共轭系统复原性能的影响。结果表明自陡峭效应将导致高斯脉冲信号发生峰值漂移和脉冲后沿变陡,相位共轭系统不能补偿由此导致的脉冲失真和畸变。引入合适的色散可以减小这种信号失真,并使得相位共轭系统能够同时补偿由于色散、自相位调制和

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The three-dimensional coupled wave theory is extended to systematically investigate the diffraction properties of finite-sized anisotropic volume holographic gratings (VHGs) under ultrashort pulsed beam (UPB) readout. The effects of the grating geometrical size and the polarizations of the recording and readout beams on the diffraction properties are presented, in particular under the influence of grating material dispersion. The wavelength selectivity of the finite-sized VHG is analyzed. The wavelength selectivity determines the intensity distributions of the transmitted and diffracted pulsed beams along the output face of the VHG. The distortion and widening of the diffracted pulsed beams are different for different points on the output face, as is numerically shown for a VHG recorded in a LiNbO3 crystal. The beam quality is analyzed, and the variations of the total diffraction efficiency are shown in relation to the geometrical size of the grating and the temporal width of the readout UPB. In addition, the diffraction properties of the finite-sized and one-dimensional VHG for pulsed and continuous-wave readout are compared. The study shows the potential application of VHGs in controlling spatial and temporal features of UPBs simultaneously. (C) 2007 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we propose a novel method for measuring the coma aberrations of lithographic projection optics based on relative image displacements at multiple illumination settings. The measurement accuracy of coma can be improved because the phase-shifting gratings are more sensitive to the aberrations than the binary gratings used in the TAMIS technique, and the impact of distortion on displacements of aerial image can be eliminated when the relative image displacements are measured. The PROLITH simulation results show that, the measurement accuracy of coma increases by more than 25% under conventional illumination, and the measurement accuracy of primary coma increases by more than 20% under annular illumination, compared with the TAMIS technique. (c) 2007 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dispersion compensation effect of the chirped fiber grating (CFG) is analyzed theoretically, and analytic expressions are derived for composite second-order (CSO) distortion in analog modulated sub-carrier multiplexed (AM-SCM) cable television (CATV) systems with externally and directly modulated transmitters. Simulations are given for the two kinds of modulations and for standard single mode fiber and non-zero dispersion shift fiber (NZDSF) systems. The results show that CFG could be used as a dispersion compensator in directly modulated systems, but its dispersion coefficient should be adjusted much more precisely than the externally modulated system. The requirements for the NZDSF system could be loosened much. It is proposed that directly modulated source may be used as a transmitter in CATV systems combined with tunable CFG dispersion compensator being adjusted precisely, which may be more cost-effective than externally modulation technology. (c) 2006 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper comprehensively analyzes the distortions of a circular wedge prism with 400 mm diameter in a scanner by method of optical-mechanical-thermal integrating analysis. The structure and intensity of the prism assembly is verified and checked, and the surface deformations of the prism under gravity load, as well as the thermo-elastic distortions of the prism, are analyzed in detail and evaluated, which is finally contrasted with the measured values of Zygo Mark interferometer. The results show: the maximal distortion of the prism assembly is 10 nm magnitude and the maximal stress is 0.441 Mpa, which has much tolerance to the precision requirement of structure and the admissible stress of material; the influence of heat effect on the surface deformations of prism is proved to be far greater than the influence of gravity load, so some strict temperature-controlled measures are to be considered when the scanner is used. (c) 2006 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A technique is developed for the design of lenses for transitioning TEM waves between conical and/or cylindrical transmission lines, ideally with no reflection or distortion of the waves. These lenses utilize isotropic but inhomogeneous media and are based on a solution of Maxwell's equations instead of just geometrical optics. The technique employs the expression of the constitutive parameters, ɛ and μ, plus Maxwell's equations, in a general orthogonal curvilinear coordinate system in tensor form, giving what we term as formal quantities. Solving the problem for certain types of formal constitutive parameters, these are transformed to give ɛ and μ as functions of position. Several examples of such lenses are considered in detail.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As hepatites crônicas por vírus são as mais frequentes, destacando-se os vírus das hepatites B (VHB) e C (VHC). O estudo anatomopatológico da biópsia hepática é considerado o padrão ouro para avaliar com precisão a distorção arquitetural e o grau de fibrose do parênquima do fígado, importantes fatores prognósticos para os pacientes portadores de hepatites crônicas virais. Na avaliação histopatológica atual, em adição aos relatos subjetivos das alterações histológicas, escores semiquantitativos que correlacionam achados morfológicos com graus numéricos são usados, tais como os reconhecidos escores de Ishak e METAVIR. Entretanto, em todos estes sistemas há a desvantagem da subjetividade do examinador e da incorporação de alterações categóricas, sem referências às mudanças quantitativas do colágeno hepático. Técnicas de análise de imagens digitais (AID) que fornecem quantificação objetiva dos graus de fibrose em amostras histológicas têm sido desenvolvidas. Todavia, o alto custo e dificuldade ao acesso das tecnologias descritas restringem seu uso a poucos centros especializados. Este estudo visa o desenvolvimento de uma técnica de custo acessível para a análise de imagens digitais da fibrose hepática em hepatites crônicas virais. Foram estudadas 304 biópsias de pacientes com hepatite crônica por vírus B e C, obtidas através de agulhas Menghini. Todas as amostras tinham pelo menos 15 mm de comprimento ou cinco espaços-porta completos e foram coradas pelo método Tricrômico de Masson. O estadiamento foi feito por um único hepatopatologista experiente, sem o conhecimento dos dados clínicos dos pacientes. Os escores de Ishak e METAVIR foram aplicados. As imagens microscópicas foram digitalizadas. Os índices de fibrose foram determinados de forma automatizada, em técnica desenvolvida no programa Adobe Photoshop. Para o escore de Ishak, observamos os seguintes índices de Fibrose (IF) médios: 0,8% 0,0 (estágio 0), 2.4% 0,6 (estágio 1), 4,7% 1,6 (estágio 2), 7,4% 1,4 (estágio 3), 14,9% 3,7 (estágio 4), 23,4% 2,9 (estágio 5) e 34,5% 1,5 (estágio 6). Para a classificação METAVIR: 0,8% 0,1 (estágio F0), 3,8% 1,8 (estágio F1), 7,4% 1,4 (estágio F2), 20,4% 5,2 (estágio F3) e 34,5% 1,5 (estágio F4). Observamos uma excelente correlação entre os índices de fibrose da AID e os escores de Ishak (r=0,94; p<0,001) e METAVIR (r=0,92; p<0,001). Em relação à indicação de tratamento antiviral, foi observado IF médio de 16,4%. Em relação ao diagnóstico de cirrose, foi observado IF médio de 26,9%, para o escore de Ishak, e 34,5% para a classificação METAVIR. A reprodutibilidade intra-observador foi excelente. Este novo método de análise de imagens digitais para a quantificação de fibrose hepática tem custo acessível e foi desenvolvido com tecnologia que está disponível em todo o mundo, permitindo identificar com precisão todos os estágios de fibrose, com excelente reprodutibilidade intra-observador.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray diffraction measurements and subsequent data analyses have been carried out on liquid argon at five states in the density range of 0.91 to 1.135 gm/cc and temperature range of 127 to 143°K. Duplicate measurements were made on all states. These data yielded radial distribution and direct correlation functions which were then used to compute the pair potential using the Percus-Yevick equation. The potential minima are in the range of -105 to -120°K and appear to substantiate current theoretical estimates of the effective pair potential in the presence of a weak three-body force.

The data analysis procedure used was new and does not distinguish between the coherent and incoherent absorption factors for the cell scattering which were essentially equal. With this simplification, the argon scattering estimate was compared to the gas scattering estimate on the laboratory frame of reference and the two estimates coincided, indicating the data normalized. The argon scattering on the laboratory frame of reference was examined for the existence of the peaks in the structure factor and the existence of an observable third peak was considered doubtful.

Numerical studies of the effect of truncation, normalization, the subsidiary peak phenomenon in the radial distribution function, uncertainties in the low angle data relative to errors in the direct correlation function and the distortion phenomenon are presented.

The distortion phenomenon for this experiment explains why the Mikolaj-Pings argon data yielded pair potential well depths from the Percus-Yevick equation that were too shallow and an apparent slope with respect to density that was too steep compared to theoretical estimates.

The data presented for each measurement are: empty cell and cell plus argon intensity, absorption factors, argon intensity, smoothed argon intensity, smoothed argon intensity corrected for distortion, structure factor, radial distribution function, direct correlation function and the pair potential from the Percus-Yevick equation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

由于群速度失配的影响,飞秒光脉冲在感应到FONPS(级联五阶非线性相移)的同时,将不可避免地发生脉冲畸变.通过理论分析及数值模拟,提出了使级联五阶非线性过程运行在较大相位失配条件下的解决方案,成功地消除了脉冲畸变.并且借助于该过程中倍频效率的提高,有效地补偿由于相位失配量的增大所造成的FONPS的下降,实现飞秒基频光脉冲在感应到大的FONPS的同时无脉冲畸变发生.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

从放大器速率方程出发,分析了掺镱双包层光纤放大器的放大特性。模拟计算了无信号输入时放大器上能级粒子数、泵浦功率和放大自发辐射(ASE)在放大器中的稳态分布。分析了前向和后向泵浦时,高功率高斯脉冲放大时的脉冲波形畸变、上能级粒子数的时间特性、放大器存储能量和脉冲能量演化等动态特性。讨论了掺镱双包层光纤放大器输出脉冲能量随不同输入脉冲峰值功率和泵浦功率的关系。该模型和结论对高功率脉冲放大器的设计和优化具有一定的理论指导意义。