907 resultados para Multifactor performance measurement
Resumo:
The Natural History of Human Papillomavirus (HPV) Infection in Men: The HIM Study is a prospective multi-center cohort study that, among other factors, analyzes participants` diet. A parallel cross-sectional study was designed to evaluate the validity and reproducibility of the quantitative food frequency questionnaire (QFFQ) used in the Brazilian center from the HIM Study. For this, a convenience subsample of 98 men aged 18 to 70 years from the HIM Study in Brazil answered three 54-item QFFQ and three 24-hour recall interviews, with 6-month intervals between them (data collection January to September 2007). A Bland-Altman analysis indicated that the difference between instruments was dependent on the magnitude of the intake for energy and most nutrients included in the validity analysis, with the exception of carbohydrates, fiber, polyunsaturated fat, vitamin C, and vitamin E. The correlation between the QFFQ and the 24-hour recall for the deattenuated and energy-adjusted data ranged from 0.05 (total fat) to 0.57 (calcium). For the energy and nutrients consumption included in the validity analysis, 33.5% of participants on average were correctly classified into quartiles, and the average value of 0.26 for weighted kappa shows a reasonable agreement. The intraclass correlation coefficients for all nutrients were greater than 0.40 in the reproducibility analysis. The QFFQ demonstrated good reproducibility and acceptable validity. The results support the use of this instrument in the HIM Study. J Am Diet Assoc. 2011;111:1045-1051.
Resumo:
Background: Oxidative modification of low-density lipoprotein (LDL) plays a key role in the pathogenesis of atherosclerosis. LDL(-) is present in blood plasma of healthy subjects and at higher concentrations in diseases with high cardiovascular risk, such as familial hypercholesterolemia or diabetes. Methods: We developed and validated a sandwich ELISA for LDL(-) in human plasma using two monoclonal antibodies against LDL(-) that do not bind to native LDL, extensively copper-oxidized LDL or malondialdehyde-modified LDL. The characteristics of assay performance, such as limits of detection and quantification, accuracy, inter- and intra-assay precision were evaluated. The linearity, interferences and stability tests were also performed. Results: The calibration range of the assay is 0.625-20.0 mU/L at 1: 2000 sample dilution. ELISA validation showed intra- and inter- assay precision and recovery within the required limits for immunoassays. The limits of detection and quantification were 0.423 mU/L and 0.517 mU/L LDL(-), respectively. The intra- and inter- assay coefficient of variation ranged from 9.5% to 11.5% and from 11.3% to 18.9%, respectively. Recovery of LDL(-) ranged from 92.8% to 105.1%. Conclusions: This ELISA represents a very practical tool for measuring LDL(-) in human blood for widespread research and clinical sample use. Clin Chem Lab Med 2008; 46: 1769-75.
Resumo:
This paper presents the use of a multiprocessor architecture for the performance improvement of tomographic image reconstruction. Image reconstruction in computed tomography (CT) is an intensive task for single-processor systems. We investigate the filtered image reconstruction suitability based on DSPs organized for parallel processing and its comparison with the Message Passing Interface (MPI) library. The experimental results show that the speedups observed for both platforms were increased in the same direction of the image resolution. In addition, the execution time to communication time ratios (Rt/Rc) as a function of the sample size have shown a narrow variation for the DSP platform in comparison with the MPI platform, which indicates its better performance for parallel image reconstruction.
Resumo:
The purpose of the work is to develop a cost effective semistationary CPC concentrator for a string PV-module. A novel method of using annual irradiation distribution diagram projected in a north-south vertical plane is developed. This method allows us easily to determine the optimum acceptance angle of the concentrator and the required number of annual tilts. Concentration ranges of 2-5x are investigated with corresponding acceptance angles between 5 and 15°. The concentrator should be tilted 2-6 times per year. Experiments has been performed on a string module of 10 cells connected in a series and equipped with a compound parabolic concentrator with C = 3.3X. Measurement show that the output will increase with a factor of 2-2.5 for the concentrator module, compared to a reference module without concentrator. If very cheap aluminium reflectors are used the costs for the PV-module can be decreased nearly by a factor of two.
Resumo:
Recent studies have shown that the optical properties of building exterior surfaces are important in terms of energy use and thermal comfort. While the majority of the studies are related to exterior surfaces, the radiation properties of interior surfaces are less thoroughly investigated. Development in the coil-coating industries has now made it possible to allocate different optical properties for both exterior and interior surfaces of steel-clad buildings. The aim of this thesis is to investigate the influence of surface radiation properties with the focus on the thermal emittance of the interior surfaces, the modeling approaches and their consequences in the context of the building energy performance and indoor thermal environment. The study consists of both numerical and experimental investigations. The experimental investigations include parallel field measurements on three similar test cabins with different interior and exterior surface radiation properties in Borlänge, Sweden, and two ice rink arenas with normal and low emissive ceiling in Luleå, Sweden. The numerical methods include comparative simulations by the use of dynamic heat flux models, Building Energy Simulation (BES), Computational Fluid Dynamics (CFD) and a coupled model for BES and CFD. Several parametric studies and thermal performance analyses were carried out in combination with the different numerical methods. The parallel field measurements on the test cabins include the air, surface and radiation temperatures and energy use during passive and active (heating and cooling) measurements. Both measurement and comparative simulation results indicate an improvement in the indoor thermal environment when the interior surfaces have low emittance. In the ice rink arenas, surface and radiation temperature measurements indicate a considerable reduction in the ceiling-to-ice radiation by the use of low emittance surfaces, in agreement with a ceiling-toice radiation model using schematic dynamic heat flux calculations. The measurements in the test cabins indicate that the use of low emittance surfaces can increase the vertical indoor air temperature gradients depending on the time of day and outdoor conditions. This is in agreement with the transient CFD simulations having the boundary condition assigned on the exterior surfaces. The sensitivity analyses have been performed under different outdoor conditions and surface thermal radiation properties. The spatially resolved simulations indicate an increase in the air and surface temperature gradients by the use of low emittance coatings. This can allow for lower air temperature at the occupied zone during the summer. The combined effect of interior and exterior reflective coatings in terms of energy use has been investigated by the use of building energy simulation for different climates and internal heat loads. The results indicate possible energy savings by the smart choice of optical properties on interior and exterior surfaces of the building. Overall, it is concluded that the interior reflective coatings can contribute to building energy savings and improvement of the indoor thermal environment. This can be numerically investigated by the choice of appropriate models with respect to the level of detail and computational load. This thesis includes comparative simulations at different levels of detail.
Resumo:
This thesis seeks to examine the difference between manufacturing and service firms with respect to the effects of knowledge on performance, and the influence of market turbulence in this relationship. Empirical data, resulting from a survey, was collected from more than 1,206 firms, involving several sectors. Two samples were analyzed, one with 334 manufacturing and other with 509 service firms. The findings indicate no significant difference in the importance of knowledge on performance between these sectors in the absence of market turbulence: knowledge development (KD) has a stronger effect than culture of competitiveness (CC) on firm performance. However, under market turbulence, manufacturers differ from service providers. The positive effect of KD is enhanced, while the positive effect of CC remains the same for manufacturing firms. On the other hand, the positive effect of KD is diminished, while the positive effect of CC is enhanced for service firms. This supports the argument concerning differences in the nature of manufacturing and service industries. From a managerial point of view, results confirm the importance of knowledge, irrespective of firm sector or market turbulence. However, while industrial firms should center efforts on KD, service firms must find a balance where knowledge development (e.g. norms, processes, routines) does not impair their culture of competitiveness (e.g. learning, innovation, action). The thesis contributes to existing literature by proposing that: (1) the positive effect of knowledge on performance is confirmed; (2) under turbulent markets manufacturing and service firms have different responses concerning the influence of knowledge on performance; (3) a multidimensional performance construct based on cost, profitability, and growth is an interesting way to evaluate firm sustained competitive advantage, rather than one-dimensional constructs; (4) the CC x KD interaction, found relevant for supply chains in previous studies, is not supported for firms; (5) differences in unit of analysis, e.g. from supply chains to firms, result in different effects of KD and CC on firm performance; (6) existing scales can be improved with the addition of more diverse indicators, capturing a wider range of concepts (e.g. information transfer measurement); and (7) results from previous studies are supported for Brazilian firms, contributing for theory generalization.
Resumo:
O objetivo deste trabalho é avaliar a persistência na performance de fundos de investimento imobiliário. Para isso, adotamos metodologia semelhante à de Carhart (1997): analisamos o desempenho, ao longo do tempo, de carteiras de fundos selecionados segundo seus percentis de retorno. Posteriormente, a performance desses fundos foi avaliada através de modelos multifatores. Para determinação desses modelos, foram criados índices baseados nas informações das ações do mercado brasileiro e do IBOVESPA. Os resultados sugerem que fundos de investimento imobiliário de retorno superior apresentam persistência em seus desempenhos. No caso dos modelos multifatores, conclui-se que os dados utilizados do mercado acionário não representam de forma satisfatória fundos de investimento imobiliário. No entanto, quando a modelagem é feita utilizando-se o IFIX, nota-se alfa positivo para os fundos mais rentáveis.
Resumo:
Este estudo avaliou o efeito da restrição alimentar e realimentação na reprodução de fêmeas e no crescimento inicial e sobrevivência de larvas de matrinxã, Brycon amazonicus. Matrizes distribuídas em 8 viveiros (15 peixes/tanque) foram alimentadas diariamente (em 4 tanques - G1) e alimentados em ciclos de 3 dias de alimentação seguidos de 2 dias de restrição (em 4 tanques - G2) por 6 meses antes da desova. Na indução à desova, 57% das fêmeas no G1 e 45% no G2 desovaram. Os pesos médios dos oócitos foram 208,1 g (G1) e 131,6 g (G2), sendo os oócitos G2 menores (1,017 ± 0,003 mm) que os oócitos de G1 (1,048 ± 0,002 mm). As taxas de fertilização (71,9 ± 12,6% e 61,2 ± 13,7%) e de eclosão (61,3 ± 33,9% e 67,5 ± 23,4%) entre os G1 e G2 não diferiram. Larvas foram coletadas na eclosão e às 24, 48 e 72 horas de incubação para medida do crescimento e as restantes transferidas para aquários e amostradas 1, 5, 9 e 15 dias depois. Na transferência, as larvas G1 e G2 tinham pesos similares (1,5 ± 0,15 e 1,46 ± 0,07 mg), mas o comprimento das larvas G2 era maior (6,2 ± 0,13 e 6,7 ± 0,14 mm). Ao 9° dia, quando é recomendada a transferência dos juvenis para tanques externos, os juvenis G2 tinham peso (13,6 ± 0,26 e 18,9 ± 0,07 mg) e comprimento (11,8 ± 0,09 e 14,5 ± 0,04 mm) maiores, mas no 15º dia os juvenis G1 eram maiores em peso (90,2 ± 1,19 e 68,6 ± 0,77 mg) e comprimento (18,8 ± 0,16 e 18,5 ± 0,04 mm). Aos 15 dias, a prole das fêmeas submetidas à restrição alimentar apresentou sobrevivência mais alta que a prole das fêmeas alimentadas diariamente (24,7 ± 2,07% e 19,2 ± 1,91%). A restrição alimentar imposta às fêmeas de matrinxã, apesar de reduzir o número de fêmeas que desovaram e a quantidade de oócitos extrusados, não afetou a fertilização e eclosão das larvas e melhorou a sobrevivência final das larvas.
Resumo:
A quantificação da evaporação do solo é requerida em estudos de balanço hídrico de culturas e em aplicações que visam a aumentar a eficiência do uso da água pelos cultivos. O objetivo deste trabalho foi testar um modelo de microlisímetro (ML) para medir a evaporação do solo em condições irrigada e não irrigada. Os MLs foram construídos utilizando tubos de PVC rígido, medindo 100 mm de diâmetro interno, 150 mm de profundidade e 2,5 mm de espessura da parede. Quatro MLs foram assentados sobre a superfície de dois lisímetros de pesagem de alta precisão conduzidos com solo nu, previamente instalados no Iapar, em Londrina-PR. Os lisímetros tinham dimensões de 1,4 m de largura, 1,9 m de comprimento e 1,3 m de profundidade, e estavam sendo conduzidos com e sem irrigação. A evaporação medida nos MLs (E ML) foi comparada com a medida nos lisímetros (E L), durante quatro períodos do ano. As diferenças entre E ML e E L foram mínimas para condições de baixa e elevada demanda atmosférica, e também para condições de solo irrigado ou não irrigado, indicado que o modelo de ML testado neste trabalho é adequado para medir a evaporação do solo.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Much has been researched and discussed in the importance played by knowledge in organizations. We are witnessing the establishment of the knowledge economy, but this "new economy" brings in itself a whole complex system of metrics and evaluations, and cannot be dissociated from it. Due to its importance, the initiatives of knowledge management must be continually assessed on their progress in order to verify whether they are moving towards achieving the goals of success. Thus, good measurement practices should include not only how the organization quantifies its knowledge capital, but also how resources are allocated to supply their growth. Thinking about the aspects listed above, this paper presents an approach to a model for Knowledge extraction using an ERP system, suggesting the establishment of a set of indicators for assessing organizational performance. The objective is to evaluate the implementation of projects of knowledge management and thus observe the general development of the organization.
Resumo:
Condition monitoring is used to increase machinery availability and machinery performance, reducing consequential damage, increasing machine life, reducing spare parts inventories, and reducing breakdown maintenance. An efficient real time vibration measurement and analysis instruments is capable of providing warning and predicting faults at early stages. In this paper, a new methodology for the implementation of vibration measurement and analysis instruments in real time based on circuit architecture mapped from a MATLAB/Simulink model is presented. In this study, signal processing applications such as FIR filters and fast Fourier transform are treated as systems, which are implemented in hardware using a system generator toolbox, which translates a Simulink model in a hardware description language - HDL for FPGA implementations.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper presents a theoretical analysis of a density measurement cell using an unidimensional model composed by acoustic and electroacoustic transmission lines in order to simulate non-ideal effects. The model is implemented using matrix operations, and is used to design the cell considering its geometry, materials used in sensor assembly, range of liquid sample properties and signal analysis techniques. The sensor performance in non-ideal conditions is studied, considering the thicknesses of adhesive and metallization layers, and the effect of residue of liquid sample which can impregnate on the sample chamber surfaces. These layers are taken into account in the model, and their effects are compensated to reduce the error on density measurement. The results show the contribution of residue layer thickness to density error and its behavior when two signal analysis methods are used. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)