889 resultados para Method Evaluation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the histological alterations occurred in the periradicular region of rat molars after intentional subluxation using an experimental method to induce dentoalveolar trauma. Eighteen adult male Wistar rats (Rattus norvegicus albinus) were selected for the study. The dentoalveolar trauma was experimentally induced by the application of an occlusogingival force on the occlusal surface of the maxillary right first molar using a tensiometer secured on a fully articulated support with adjustable steel shafts. The animals were assigned to six groups (n = 3), according to the intensity of the force applied to induce trauma: Group I (GI, control) - no force application; Groups II-VI (GII-GVI) - the animals were subjected to 600, 700, 800, 900 and 1000 cN force, respectively. After experimental induction of trauma, the animals were sacrificed by anesthetic overdose and the right maxillas were removed and processed for histological analysis under light microscopy. In the animals of GII, GIII and GIV, the histological alterations were similar to those described for GI. GVI (1000 cN) presented the most severe alterations, with the occurrence of buccal bone plate fracture, alveolar fracture and root fracture, which are not present in mild traumatic injuries like subluxation. The 900 cN force (GV) was capable to produce clinical and histological alterations in the gingival and periodontal tissues compatible with those observed in subluxation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study sought to evaluate the effect of repeated implant drilling on the immediate bone-cell viability, and to evaluate drill wear by scanning electron microscopy.Materials and Methods: The tibiae of 10 rabbits were used, divided into 5 groups (G): G1 corresponded to new drills, and G2, G3, G4, and G5 corresponded to drills used 10, 20, 30, and 40 times, respectively. The animals received 10 sequential osteotomies in each tibia. The animals were euthanized immediately after the osteotomies by perfusion with 4% formaldehyde. Samples then underwent immunohistochemistry processing for ordinal qualitative analysis of osteoprotegerin (OPG), the RANK ligant (RANKL; a tumor-related necrosis factor receptor family), and osteocalcin protein immunolabels, as detected by the immunoperoxidase method and revealed with 3,3-diaminobenzidine. Drill wear and plastic deformation were analyzed by scanning electron microscopy (SEM).Results: The proteins were expressed in osteocytes of the superior bone cortical during the 40 drillings. However, in G4 and G5, a discrete increase in the expression of RANKL was observed, when compared with OPG; this increase was statistically significant in G5 (P = .016). The SEM analysis revealed major plastic deformation and drill wear in G4 and G5.Conclusion: Based on the present methodology, it may be concluded that cell viability is preserved if a less traumatic surgical protocol is used. However, the repeated use of drills alters the protein balance as of the thirtieth perforation. (C) 2008 American Association of Oral and Maxillofacial Surgeons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to compare two methodologies used in the evaluation of tissue response to root-end filling materials in rats. Material and Methods: Forty rats were divided into 4 groups: in Groups I and II (control groups), empty polyethylene tubes were implanted in the extraction site and in the subcutaneous tissue, respectively; in Groups III and IV, polyethylene tubes filled with ProRoot MTA were implanted in the extraction site and in the subcutaneous tissue, respectively. The animals were killed 7 and 30 days after tube implantation, and the hemi-maxillas and the capsular subcutaneous tissue, both with the tubes, were removed. Specimens were processed and evaluated histomorphologicaly under light microscopy. The scores obtained were analyzed statistically by the Kruskal-Wallis test (p<0.05). Results: There were no statistically significant differences between the implantation methods (p=0.78033, p=0.72039). It was observed that the 30-day groups presented a more mature healing process due to smaller number of inflammatory cells. Conclusions: The present study showed no differences in tissue responses as far as the implantation site and the studied period were concerned. Alveolar socket implantation methodology represents an interesting method in the study of the biological properties of root-end filling endodontic materials due to the opportunity to evaluate bone tissue response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the biomechanical behavior of a mandibular distal extension removable partial denture (DERPD) associated with an implant and different retention system, by bidimensional finite element method. Five hemimandible models with a canine and external hexagon implant at second molar region associated with DERPD were simulated: model A, hemimandible with a canine and a DERPD; model B, hemimandible with a canine and implant with a healing abutment associated to a DERPD; model C, hemimandible with a canine and implant with an ERA attachment associated to a DERPD; model D, hemimandible with a canine and implant with an O'ring attachment associated to a DERPD; and model E, hemimandible with a canine and implant-supported prosthesis associated to a DERPD. Cusp tips were loaded with 50 N of axial or oblique force (45 degrees). Finite element analysis was performed in ANSYS 9.0. model E showed the higher displacement and overload in the supporting tissues; the patterns of stress distribution around the dental apex of models B, C, and D were similar. The association between a DERPD and an osseointegrated implant using the ERA or O'ring systems shows lower stress values. Oblique forces showed higher stress values and displacement. Oblique forces increased the displacement and stress levels in all models; model C displayed the best stress distribution in the supporting structures; healing abutment, ERA, and O'ring systems were viable with RPD, but DERPD association with a single implant-supported prosthesis was nonviable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Ultrasonic excitation (US) was applied to glass ionomer cement (GIC) during early set time to increase the advantageous properties of this material. Purpose: The aim of this in vitro study was to assess the inner porosity of GIC after US. Study design: A total of 16 specimens, for each material, were prepared from high-viscosity GIC Fuji IX GP, Ketac Molar, and Ketac Molar Easymix. Half of these specimens (n = 8) received 30 s of US during the initial cement setting. After completion of the material setting, specimens were fractured and observed by scanning electronic microscopy to quantitatively assay porosity inside the material using Image J software. Results: Statistical data analysis revealed that US reduced the porosity for all tested materials (P <= 0.05). The following reductions (expressed in percentages) were achieved: Fuji IX-from 3.9% to 2.8%; Ketac Molar Easy Mix-from 4.4% to 2.6%, and Ketac Molar-from 2.4% to 1.6%. Conclusion: Under the tested conditions, US was an effective method for porosity reduction inside the material. Microsc. Res. Tech. 74:54-57, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate 2 techniques for the treatment of human primary molars with necrotic Pulp and bifurcation bone loss by means of radiographic examination for 48 months. Method and Materials: Fifty-one mandibular primary molars were evaluated in children ranging from 4.5 to 6.5 years of age. The teeth with necrotic pulp and bifurcation bone loss were diagnosed by radiographic examination. The teeth were divided into 2 groups: group 1 (28 teeth)-pulpotomy technique using formocresol as a temporary dressing between sessions and coronal chamber obturation with zinc oxide-eugenol cement; and group 2 (23 teeth)-pulpectomy technique with calcium hydroxide paste as a temporary dressing between sessions and root canal obturation with a dense Calcium hydroxide paste. Standardized radiographs were taken immediately after the fillings were completed and after 12, 24, 36, and 48 months. The radiographs were digitized and analyzed with software that outlined and measured the bifurcation radiolucency. Results: Bifurcation radiolucency reduced significantly or repaired completely for both treatnients in the first 12 months. Minor radiographic reduction of the lesion was observed from 12 to 24 months, and no significant reduction of the remaining radioulcent area was observed from 24 to 48 months after treatment. Conclusion: The 2 endodontic techniques evaluated showed similar results. The main effect of treatment on the lesion repair was obtained in the first year after treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the effectiveness of two alternatives methods for the disinfection of oral cleaning devices. Methods: One type of toothbrush and two types of tongue scrapers (steel and plastic) were tested in this study. Sixteen specimens of each group were cut with standardized dimensions, contaminated separately with Candida albicans, Streptococcus mutans and Staphylococcus aureus and incubated for 24 h. After this, oral cleaning devices were washed in saline solution to remove non-adhered cells and divided into two groups (n = 8), one irradiated in microwave and other immersed in 3.78% sodium perborate solution, and evaluated for microbial recovery. The values of cfu of each group of microorganism after disinfection were compared by Kruskal-Wallis and Dunn non-parametric test, considering 95% of confidence. Results: The toothbrush harboured a significant larger number of viable organisms than the tongue scrapers. The steel tongue scraper was less susceptible to adhesion of the three oral microorganisms. The time required to inactivate all contaminating microorganisms using microwave oven was 1 min and, for the immersion in 3.78% sodium perborate solution, was 2 and 3 h, respectively, for C. albicans and S. mutans/S. aureus. Conclusion: Microwave irradiation proved to be an effective alternative method to the disinfection of tongue cleaners and toothbrushes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This investigation evaluated the knowledge of dental caries and periodontal disease among removable partial denture (RPD) wearers.Method: A total of 127 partially dentate patients participated in this observational study. A structured questionnaire, which included eight questions referring to knowledge about aetiology and prevention of dental caries and periodontal disease, was developed in the local language (Portuguese) and used to collect the data of all the partial denture wearers. A descriptive analysis of data was performed by means of drafting tables.Results: The results demonstrated that 68.5% of patients interviewed had previously received information about oral health care. With regard to bacterial plaque, it was observed that only 34.6% reported having knowledge of this. Whereas, in relation to caries, 76.4% of the interviewees replied that they knew the meaning of this. Nevertheless, 28.3% referred to caries as a whole in the teeth, 16.5% as bad teeth and 9.4% bacteria/creatures on the teeth. Only 17.3% of the partially edentulous patients evaluated were shown to know what disease of the gingiva was.Conclusion: By means of the methodology applied, it could be concluded that the patients who wore RPDs presented deficient knowledge with regard to the prevention, aetiology and development of dental caries and periodontal disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Open access publishing is becoming increasingly popular within the biomedical sciences. SciELO, the Scientific Electronic Library Online, is a digital library covering a selected collection of Brazilian scientific journals many of which provide open access to full-text articles. This library includes a number of dental journals some of which may include reports of clinical trials in English, Portuguese and/or Spanish. Thus, SciELO could play an important role as a source of evidence for dental healthcare interventions especially if it yields a sizeable number of high quality reports. Objective: The aim of this study was to identify reports of clinical trials by handsearching of dental journals that are accessible through SciELO, and to assess the overall quality of these reports. Material and methods: Electronic versions of six Brazilian dental Journals indexed in SciELO were handsearched at www.scielo.br in September 2008. Reports of clinical trials were identified and classified as controlled clinical trials (CCTs - prospective, experimental studies comparing 2 or more healthcare interventions in human beings) or randomized controlled trials (RCTs - a random allocation method is clearly reported), according to Cochrane eligibility criteria. Criteria to assess methodological quality included: method of randomization, concealment of treatment allocation, blinded outcome assessment, handling of withdrawals and losses and whether an intention-to-treat analysis had been carried out. Results: The search retrieved 33 CCTs and 43 RCTs. A majority of the reports provided no description of either the method of randomization (75.3%) or concealment of the allocation sequence (84.2%). Participants and outcome assessors were reported as blinded in only 31.2% of the reports. Withdrawals and losses were only clearly described in 6.5% of the reports and none mentioned an intention-to-treat analysis or any similar procedure. Conclusions: The results of this study indicate that a substantial number of reports of trials and systematic reviews are available in the dental journals listed in SciELO, and that these could provide valuable evidence for clinical decision making. However, it is clear that the quality of a number of these reports is of some concern and that improvement in the conduct and reporting of these trials could be achieved if authors adhered to internationally accepted guidelines, e. g. the CONSORT statement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: the goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class 11 restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). Method and materials: Forty human caries-free molars were extracted and selected. Eighty Class 11 standardized cavities were made in the cervical wall at the cementoenamel junction (CEJ) and at the mesial and distal surfaces. The teeth were divided into four groups: G1 - adhesive system + microhybrid resin composite Z100; G2 - adhesive system + compactable resin composite Prodigy Condensable; G3 - adhesive system + flowable resin composite Revolution + Z1 00 resin composite; G4 - adhesive system + Revolution fluid resin + compactable resin composite Prodigy Condensable. The adhesive system used in this study was Scotchbond Multi-Purpose Plus. The specimens were thermocycled in baths of 5degreesC and 55degreesC for 1,000 cycles and immersed in 50% silver nitrate solution. The specimens then were sectioned and evaluated on degree of dye penetration. Results: the results were evaluated using the nonparametric Kruskall-Wallis test, which showed a statistically significant difference between groups G1 and G4, G2 and G4, and G3 and G4. Conclusions: None of the materials was able to eliminate the marginal microleakage at the cervical wall; the application of a low-viscosity resin composite combined with a compactable resin composite significantly decreased the microleakage.