879 resultados para Metals Bank


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of our study was to determine the trace metal accumulation rates in the Misten bog, Hautes-Fagnes, Belgium, and assess these in relation to established histories of atmospheric emissions from anthropogenic sources. To address these aims we analyzed trace metals and metalloids (Pb, Cu, Ni, As, Sb, Cr, Co, V, Cd and Zn), as well as Pb isotopes, using XRF, Q-ICP-MS and MC-ICP-MS, respectively in two 40-cm peat sections, spanning the last 600 yr. The temporal increase of metal fluxes from the inception of the Industrial Revolution to the present varies by a factor of 5–50, with peak values found between AD 1930 and 1990. A cluster analysis combined with Pb isotopic composition allows the identification of the main sources of Pb and by inference of the other metals, which indicates that coal consumption and metallurgical activities were the predominant sources of pollution during the last 600 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research on the Israeli checkpoints in the West Bank has emphasized not only that these checkpoints have dire implications for the Palestinians living there, at the personal, familial, and communal levels, and devastating eff ects on the Palestinian economy, but also that they have far-reaching consequences for the ability of the Palestinians to establish an independent political entity. At the same time, analysis of the Israeli forms of domination over the Palestinians has also stressed the role of a Palestinian governing authority in sustaining the Israeli rule, since the former relieves the latter of its responsibility to care for the occupied Palestinian population. This paper aims to address this apparent contradiction claiming that a comprehensive analysis of Israeli forms of domination requires a spatial examination of the operation of sovereignty with an assessment of governmentalizing arrays. This combined analysis suggests that a Palestinian sovereignty, but one which is emptied of its actual ruling power, is construed at the checkpoints as an epiphenomenon of Israeli apparatuses of control. © 2013 Pion and its Licensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present invention relates to a process for the removal of mercury from a mercury- containing hydrocarbon fluid feed using specifically selected ionic liquids comprising, contacting the mercury-containing hydrocarbon fluid feed with an ionic liquid having the formula[Cat+][M+][X-] and separating from the ionic liquid a hydrocarbon fluid product having a reduced mercury content compared to the mercury-containing fluid feed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new formulation of the correlated electron-ion dynamics (CEID) scheme, which systematically improves Ehrenfest dynamics by including quantum fluctuations around the mean-field atomic trajectories. We show that the method can simulate models of nonadiabatic electronic transitions and test it against exact integration of the time-dependent Schrodinger equation. Unlike previous formulations of CEID, the accuracy of this scheme depends on a single tunable parameter which sets the level of atomic fluctuations included. The convergence to the exact dynamics by increasing the tunable parameter is demonstrated for a model two level system. This algorithm provides a smooth description of the nonadiabatic electronic transitions which satisfies the kinematic constraints (energy and momentum conservation) and preserves quantum coherence. The applicability of this algorithm to more complex atomic systems is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite being the most suitable candidates for solenoid pole pieces in state-of-the-art superconductor- based electromagnets, the intrinsic magnetic properties of heavy rare earth metals and their alloys have gained comparatively little attention. With the potential of integration in micro- and nanoscale devices, thin films of Gd, Dy, Tb, DyGd and DyTb were plasma-sputtered and investigated for their in-plane magnetic properties, with an emphasis on magnetisation vs. temperature profiles. Based on crystal structure analysis of the polycrystalline rare earth films, which consist of a low magnetic moment FCC layer at the seed interface topped with a higher moment HCP layer, an experimental protocol is introduced which allows the direct magnetic analysis of the individual layers. In line with the general trend of heavy lanthanides, the saturation magnetisation was found to drop with increasing unit cell size. In-situ annealed rare earth films exceeded the saturation magnetisation of a high-moment Fe65Co35 reference film in the cryogenic temperature regime, proving their potential for pole piece applications; however as-deposited rare earth films were found completely unsuitable. In agreement with theoretical predictions, sufficiently strained crystal phases of Tb and Dy did not exhibit an incommensurate magnetic order, unlike their single-crystal counterparts which have a helical phase. DyGd and DyTb alloys followed the trends of the elemental rare earth metals in terms of crystal structure and magnetic properties. Inter-rare-earth alloys hence present a desirable blend of saturation magnetisation and operating temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Why do some banks fail in financial crises while others survive? This article answers this question by analysing the effect of the Dutch financial crisis of the 1920s on 142 banks, of which 33 failed. We find that choices of balance sheet composition and product market strategy made in the lead-up to the crisis had a significant impact on banks’ subsequent chances of experiencing distress. We document that high-risk banks – those operating highly-leveraged portfolios and attracting large quantities of deposits – were more likely to fail. Branching and international activities also increased banks’ default probabilities. We measure the effects of board interlocks, which have been characterized in the extant literature as contributing to the Dutch crisis. We find that boards mattered: failing banks had smaller boards, shared directors with smaller and very profitable banks and had a lower concentration of interlocking directorates in non-financial firms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel diffusive gradients in thin film probe developed comprises diffusive gel layer of silver iodide (AgI) and a back-up Microchelex resin gel layer. 2D high-resolution images of sulfide and trace metals were determined respectively on the AgI gel by densitometric analysis and on the Microchelex resin layer with laser-ablation-inductively-coupled plasma mass spectrometry (LA-ICP-MS).We investigated the validity of the analytical procedures used for the determination of sulfide and trace metals. We found low relative standard deviations on replicate measurements, linear trace-metal calibration curves between the LA-ICP-MS signal and the true trace-metal concentration in the resin gel, and a good agreement of the sulfide results obtained with the AgI resin gel and with other analytical methods. The method was applied on anoxic sediment pore waters in an estuarine and marine system. Simultaneous remobilization of sulfide and trace metals was observed in the marine sediment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the Oslo Accords were signed between Israel and the Palestinian Liberation Organization (PLO) in September 1993, the international community has supported civil policing programmes. It has done so as part of its development commitments to Palestinian state-building. Such programmes were, until the outbreak of the second Intifada in 2000, largely regarded as successful in terms of supporting the establishment of a Palestinian civil police (PCP). Such programmes were essentially Western imported models which loosely mixed community and public order policing approaches. With re-engagement in the Palestinian security sector (PSS) in the West Bank in 2007, the international community has once again sought to play a major role in PSS reform. This role includes supporting rehabilitation and retraining of the PCP as a principal institution of state-building. Such activities alongside the so-called transformation efforts within the wider realm of the PSS have re-established as their goal law and order. Within the transformation agenda, there are inherent demands with respect to Israel and the Palestinian National Authority's security and counterterrorism agendas. This analysis examines these activities, and accompanying political intent to contend that such approaches are undermining principles of democratic policing including civil police primacy (CPP). CPP reinforces police universality and means supporting rule of law by putting security under governmental control with proper mechanisms of accountability. This article argues that support to the security sector in the West Bank has increasingly only paid lip service or sought to subvert normative approaches to democratic policing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel hand-held instrument capable of real-time in situ detection and identification of heavy metals. The proposed system provides the facilities found in a traditional lab-based instrument in a hand held a design. In contrast to existing commercial systems, it can stand alone without the need of an associated computer. The electrochemical instrument uses anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The sensors comprise disposable screen-printed (solid working) electrodes rather than the more common hanging mercury drop electrodes. The system is reliable, easy to use, safe, avoids expensive and time-consuming procedures and may be used in a variety of situations to help in the fields of environmental assessment and control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a portable electrochemical instrument capable of detecting and identifying heavy metals in soil, in situ. The instrument has been developed for use in a variety of situations to facilitate contaminated land surveys, avoiding expensive and time-consuming procedures. The system uses differential pulse anodic stripping voltammetry which is a precise and sensitive analytical method with excellent limits of detection. The identification of metals is based on a statistical microprocessor-based method. The instrument is capable of detecting six different toxic metals (lead, cadmium, zinc, nickel, mercury and copper) with good sensitivity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an electrochemical instrumentation system capable of real-time in situ detection of heavy metals. A practical approach to introduce acidity compensation against changes in amplitude of the peak currents is also presented. The compensated amplitudes can then be used to predict the concentration level of heavy metals. The system uses differential pulse anodic stripping voltammetry, which is a precise and sensitive analytical method with excellent limits of detection. The instrument is capable of detecting lead, cadmium, zinc, nickel and copper with good sensitivity and precision. The system avoids expensive and time-consuming procedures and may be used in a variety of situations to help environmental assessment and control. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a portable electrochemical instrument capable of real-time in situ detection and automatic identification of heavy metals. The instrument is equipped with an embedded Geographical Position System and is capable of storing the geographical position of the sample under test. Software has been developed to combine pollutant results with geographical position, in order to produce a cartographical presentation of the pollution of an area. The electrochemical instrument provides the facilities found in a traditional lab based instrument in a portable design for on-site measurements. The instrument is capable of detecting lead, cadmium, zinc, nickel, mercury, and copper with good sensitivity and precision. The system is reliable, easy to use, safe, and it may be used in a variety of situations to help environmental assessment and control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents a low-cost portable electrochemical instrument capable of on-site identification of heavy metals. The instrument acquires metal-specific voltage and current signals by the application of differential pulse anodic stripping voltammetry. This technique enhances the analytical current and rejects the background current, resulting in a higher signal-to-noise ratio for a better detection limit. The identification of heavy metals is based on an intelligent machine-based method using a multilayer perceptron neural network consisting of three layers of neurons. The neural network is implemented using a 16 bit microcontroller. The system is developed for use in the field in order to avoid expensive and time-consuming procedures and can be used in a variety of situations to help environmental assessment and control.