985 resultados para Main chain polymers
Resumo:
Microalgae are promising microorganisms for the production of food and fine chemicals. Several species of microalgae are used in aquaculture with the purpose of transfer bioactive compounds up to the aquatic food chain. The main objective of this project was to develop a stress–inducement strategy in order to enhance the biochemical productivity of Nannochloropsis gaditana, Rhodomonas marina and Isochrysis sp. for aquaculture purposes having in account their growth and organizational differences. In this regard, two experiments were design: the first one consisted on the alteration of overall nutrient availabilities in growth medium; and the second one comprised changes in nitrogen and sulfur concentrations maintaining the concentrations of the other nutrients present in a commercial growth medium (Nutribloom plus), which is frequently used in aquaculture. Microalgae dried biomass was characterized biochemically and elemental analysis was also performed for all samples. In first experimental design: linear trends between nutrient availability in growth media and microalgae protein content were obtained; optimum productivities of eicosapentaenoic (EPA) and docosahexaenoic acids (DHA) were attained for both R. marina and N. gaditana in growth media enriched with 1000 L L-1 of nutrient solution whereas for Isochrysis sp. the double of Nutribloom plus was needed; the decrease of glucans and total monosaccharides with nutrient availability for R. marina and Isochrysis sp. showed the occurrence of a possible depletion of carbohydrates towards lipids and proteins biosynthesis. Second experimental desing: N. gaditana exhibited the highest variation in their biochemical composition against the applied perturbation; variations observed for microalgae in their biochemical composition were reflected in their elemental stoichiometry; in N. gaditana the highest nitrogen concentrations lead to overall maximum productivities of the biochemical parameters. The results of the present work show two stress-inducement strategies for microalgae that may constitute a base for further investigations on their biochemical enhancement.
Resumo:
This work describes a novel use for the polymeric film, poly(o-aminophenol) (PAP) that was made responsive to a specific protein. This was achieved through templated electropolymerization of aminophenol (AP) in the presence of protein. The procedure involved adsorbing protein on the electrode surface and thereafter electroploymerizing the aminophenol. Proteins embedded at the outer surface of the polymeric film were digested by proteinase K and then washed away thereby creating vacant sites. The capacity of the template film to specifically rebind protein was tested with myoglobin (Myo), a cardiac biomarker for ischemia. The films acted as biomimetic artificial antibodies and were produced on a gold (Au) screen printed electrode (SPE), as a step towards disposable sensors to enable point-of-care applications. Raman spectroscopy was used to follow the surface modification of the Au-SPE. The ability of the material to rebind Myo was measured by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). The devices displayed linear responses to Myo in EIS and SWV assays down to 4.0 and 3.5 μg/mL, respectively, with detection limits of 1.5 and 0.8 μg/mL. Good selectivity was observed in the presence of troponin T (TnT) and creatine kinase (CKMB) in SWV assays, and accurate results were obtained in applications to spiked serum. The sensor described in this work is a potential tool for screening Myo in point-of-care due to the simplicity of fabrication, disposability, short time response, low cost, good sensitivity and selectivity.
Resumo:
Microcystin-LR (MC-LR) is a dangerous toxin found in environmental waters, quantified by high performance liquid chromatography and/or enzyme-linked immunosorbent assays. Quick, low cost and on-site analysis is thus required to ensure human safety and wide screening programs. This work proposes label-free potentiometric sensors made of solid-contact electrodes coated with a surface imprinted polymer on the surface of Multi-Walled Carbon NanoTubes (CNTs) incorporated in a polyvinyl chloride membrane. The imprinting effect was checked by using non-imprinted materials. The MC-LR sensitive sensors were evaluated, characterized and applied successfully in spiked environmental waters. The presented method offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.
Resumo:
The present work reports new sensors for the direct determination of Microcystin-LR (MC-LR) in environmental waters. Both selective membrane and solid contact were optimized to ensure suitable analytical features in potentiometric transduction. The sensing layer consisted of Imprinted Sol–Gel (ISG) materials capable of establishing surface interactions with MC-LR. Non-Imprinted Sol–Gel (NISG) membranes were used as negative control. The effects of an ionic lipophilic additive, time of sol–gel polymerization, time of extraction of MC-LR from the sensitive layer, and pH were also studied. The solid contact was made of carbon, aluminium, titanium, copper or nickel/chromium alloys (80 : 20 or 90 : 10). The best ISG sensor had a carbon solid contact and displayed average slopes of 211.3 mV per decade, with detection limits of 7.3 1010 M, corresponding to 0.75 mg L1 . It showed linear responses in the range of 7.7 1010 to 1.9 109 M of MC-LR (corresponding to 0.77–2.00 mg L1 ), thus including the limiting value for MC-LR in waters (1.0 mg L1 ). The potentiometric-selectivity coefficients were assessed by the matched potential method for ionic species regularly found in waters up to their limiting levels. Chloride (Cl) showed limited interference while aluminium (Al3+), ammonium (NH4 + ), magnesium (Mg2+), manganese (Mn2+), sodium (Na+ ), and sulfate (SO4 2) were unable to cause the required potential change. Spiked solutions were tested with the proposed sensor. The relative errors and standard deviation obtained confirmed the accuracy and precision of the method. It also offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.
Resumo:
A new man-tailored biomimetic sensor for Chlorpromazine host-guest interactions and potentiometric transduction is presented. The artificial host was imprinted within methacrylic acid, 2-vinyl pyridine and 2-acrylamido-2-methyl-1-propanesulfonic acid based polymers. Molecularly imprinted particles were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. Slopes and detection limits ranged 51–67 mV/decade and 0.46–3.9 μg/mL, respectively, in steady state conditions. Sensors were independent from the pH of test solutions within 2.0–5.5. Good selectivity was observed towards oxytetracycline, doxytetracycline, ciprofloxacin, enrofloxacin, nalidixic acid, sulfadiazine, trimethoprim, glycine, hydroxylamine, cysteine and creatinine. Analytical features in flowing media were evaluated on a double-channel manifold, with a carrier solution of 5.0 × 10−2 mol/L phosphate buffer. Near-Nernstian response was observed over the concentration range 1.0 × 10−4 to 1.0 × 10−2 mol/L. Average slopes were about 48 mV/decade. The sensors were successfully applied to field monitoring of CPZ in fish samples, offering the advantages of simplicity, accuracy, automation feasibility and applicability to complex samples.
Resumo:
This work proposes a new biomimetic sensor material for trimethoprim. It is prepared by means of radical polymerization, having trimethylolpropane trimethacrylate as cross-linker, benzoyl peroxide as radicalar iniciator, chloroform as porogenic solvent, and methacrylic acid and 2-vinyl pyridine as monomers. Different percentages of sensor in a range between 1 and 6% were studied. Their behavior was compared to that obtained with ion-exchanger quaternary ammonium salt (additive tetrakis(p-chlorophenyl)borate or tetraphenylborate). The effect of an anionic additive in the sensing membrane was also tested. Trimethoprim sensors with 1% of imprinted particles from methacrylic acid monomers showed the best response in terms of slope (59.7 mV/decade) and detection limit (4.01 × 10− 7 mol/L). These electrodes displayed also a good selectivity towards nickel, manganese aluminium, ammonium, lead, potassium, sodium, iron, chromium, sulfadiazine, alanine, cysteine, tryptophan, valine and glycine. The sensors were not affected by pH changes from 2 to 6. They were successfully applied to the analysis of water from aquaculture.
Resumo:
As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1 × 10−5 and 5.5 × 10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.
Resumo:
A theory of free vibrations of discrete fractional order (FO) systems with a finite number of degrees of freedom (dof) is developed. A FO system with a finite number of dof is defined by means of three matrices: mass inertia, system rigidity and FO elements. By adopting a matrix formulation, a mathematical description of FO discrete system free vibrations is determined in the form of coupled fractional order differential equations (FODE). The corresponding solutions in analytical form, for the special case of the matrix of FO properties elements, are determined and expressed as a polynomial series along time. For the eigen characteristic numbers, the system eigen main coordinates and the independent eigen FO modes are determined. A generalized function of visoelastic creep FO dissipation of energy and generalized forces of system with no ideal visoelastic creep FO dissipation of energy for generalized coordinates are formulated. Extended Lagrange FODE of second kind, for FO system dynamics, are also introduced. Two examples of FO chain systems are analyzed and the corresponding eigen characteristic numbers determined. It is shown that the oscillatory phenomena of a FO mechanical chain have analogies to electrical FO circuits. A FO electrical resistor is introduced and its constitutive voltage–current is formulated. Also a function of thermal energy FO dissipation of a FO electrical relation is discussed.
Resumo:
INTRODUCTION: Invasive fungal infections (IFIs) are a life-threatening complication in patients with hematologic malignancies, mainly in acute leukemia patients, following chemotherapy. IFI incidence is increasing, and associated mortality remains high due to unreliable diagnosis. Antifungal drugs are often limited by inadequate antimicrobial spectrum and side effects. Thus, the detection of circulating fungal DNA has been advocated as a rapid, more sensitive diagnostic tool. PATIENTS AND METHODS: Between June 01 and January 03, weekly blood samples (1,311) were screened from 193 patients undergoing intensive myelosuppressive or immunosuppressive therapy. IFI cases were classified according to European Organization for Research and Treatment of Cancer/Mycoses Study Group criteria. Fungal DNA was extracted from whole blood and amplified using polymerase chain reaction (PCR) published primers that bind to the conserved regions of the fungal 18S rRNA gene sequence. In our study, two or more consecutive positive samples were always associated with fungal disease. RESULTS: PCR screening predicted the development of IFI to be 17 days (median). This test had a specificity of 91.1% and a sensitivity of 75%. IFI incidence was 7.8%. DISCUSSION: Therefore, our results confirm the potential usefulness of PCR serial screening and the clinical applicability in everyday routine. PCR screening offers a noninvasive repeatable aid to the diagnosis of IFI.
Resumo:
A indústria automóvel exige, em geral, elevados índices de produtividade e qualidade. Para corresponder às exigências deste tipo de indústria, são requeridos métodos avançados de produção, tentando eliminar ao máximo operações que não gerem valor acrescentado e que possam introduzir problemas no processo de garantia da qualidade. A maquinagem por arranque de apara é um processo utilizado de forma intensiva na indústria automóvel. No entanto, enquanto em componentes críticos como o motor, os processos estão já altamente otimizados, o mesmo não se verifica na maior parte dos sistemas periféricos, normalmente realizados por empresas mais pequenas que gravitam em torno dos principais fornecedores da cadeia de produção de automóveis. Os sistemas responsáveis pela movimentação dos limpa pára-brisas e elevação dos vidros, entre outros, encontram-se neste grupo. Este trabalho visa essencialmente otimizar o processo de maquinagem de componentes periféricos de automóveis, sujeitos a diferentes operações em vários planos. No entanto, e tal como em muitas outras situações relacionadas com a variedade de versões existentes na indústria automóvel relativamente a cada sistema, pretende-se que o processo seja suficientemente versátil para poder ser aplicado em vários componentes de uma mesma família de produtos, necessitando de um número de ajustes o mais baixo possível. O estudo passou por uma análise profunda das similaridades geométricas dos diferentes componentes, análise dos planos de maquinagem de cada componente, operações envolvidas, elencagem da necessidade específica de ferramentas, elaboração de gabaritos de fabrico e apresentação da solução final, a qual passa pela introdução de um 4º eixo e do seu controlo através do sistema CNC já existente, assim como pela elaboração de novos programas.
Resumo:
Forty-six allogeneic hematopoietic stem cell transplantation (HSCT) patients were monitored for the presence of CMV antibodies, CMV-DNA and CMV antigens after transplantation. Immunoenzymatic serological tests were used to detect IgM and the increase in CMV IgG antibodies (increase IgG), a nested polymerase chain reaction (N-PCR) was used to detect CMV-DNA, and an antigenemia assay (AGM) was used to detect CMV antigens. The presence of CMV-IgM and/or CMV-increase IgG antibodies was detected in 12/46 (26.1%) patients, with a median time between HSCT and the detection of positive serology of 81.5 days. A positive AGM was detected in 24/46 (52.2%) patients, with a median time between HSCT and antigen detection of 62 days. Two or more consecutive positive N-PCR results were detected in 32/46 (69.5%) patients, with a median time between HSCT and the first positive PCR of 50.5 days. These results confirmed that AGM and mainly PCR are superior to serology for the early diagnosis of CMV infection. Six patients had CMV-IgM and/or CMV-increase IgG with a negative AGM (five cases) or N-PCR assay (one case). In five of these cases the serological markers were detected during the first 100 days after HSCT, the period of highest risk. These findings support the idea that serology may be useful for monitoring CMV infections in HSCT patients, especially when PCR is unavailable.
Resumo:
Este trabalho foi realizado na Scania CV AB e teve como principal objectivo estabelecer uma diretriz sobre a possível utilização de aços vazados. Existe uma grande necessidade na realização deste trabalho, de forma a apoiar os engenheiros de projecto no seu processo de selecção dos materiais mais adequados, para produzir componentes mais leves e de elevado desempenho. Esta diretriz apresenta informação relacionada com propriedades mecânicas, processos de fundição, vazabilidade, tipologia de defeitos, tratamentos térmicos, soldabilidade e tratamentos superficiais dos aços vazados. Este trabalho foi limitado, na seleção de materiais para componentes do camião, a aços vazados que poderiam ser aplicados em dois componentes específicos: um componente estrutural da carroçaria sujeito a esforços de fadiga e a um colector de gases de combustão, sujeito a fluência, oxidação, fadiga por corrosão, fadiga-térmica e fadiga-mecânica. Foi realizado um benchmark focado nestes dois componentes de forma a saber que materiais são utilizados de momento por outras empresas concorrentes. Foi realizada ainda uma análise sobre possíveis materiais que possam ser aplicados em cada componente referido. Foi conduzida uma caracterização no estado bruto de fundição de um aço inoxidável vazado usado para produzir um protótipo do colector de gases. Esta caracterização consistiu numa análise microestrutural e medição de macro e microdurezas. Além da caracterização inicial, foram aplicados um conjunto de tratamentos térmicos, de forma a estudar a possibilidade de eliminar os carbonetos presentes inicialmente nas fronteiras de grão. As principais conclusões deste trabalho são que o aço vazado apresenta potencial para ser uma escolha válida em diversas aplicações, devido a um leque alargado de propriedades apresentadas tipicamente por este material. Relativamente a aplicações estruturais, o aço vazado é vantajoso comparativamente ao ferro fundido, quando são requeridos, por exemplo, soldabilidade e elevada resistência, combinada com elevada tenacidade à fractura. Para componentes sujeitos a elevadas temperaturas de serviço, o aço inoxidável vazado é vantajoso quando usado a temperaturas superiores a 750°C, apesar do seu elevado custo. O tratamento térmico composto por um recozimento de solubilização seguido de envelhecimento, elimina quase na totalidade os carbonetos presentes nas fronteiras de grão e verifica-se um aumento de dureza através de uma precipitação de carbonetos finamente dispersos na matriz, que poderão também aumentar a resistência à fluência.
Resumo:
Background Over the years, food industry wastes have been the focus of a growing interest due to their content in high added-value compounds. A good example are the olive oil by-products (OOBP), which retain a great amount of phenolic compounds during olive oil production. Their structure and biological properties justify their potential use as antioxidants in other food products. The efficient recovery of phenolic compounds has been extensively studied and optimized in order to maximize their reintroduction in the food chain and contribute to a higher valorization and better management of wastes from olive oil industry. Scope and approach This paper reviews the most representative phenolic compounds described in OOBP and their biological properties. New extraction procedures to efficiently recover these compounds and the most advanced chromatographic techniques that have been used for a better understanding of the phenolic profile of these complex matrices are also referred. Finally, this paper reports the main applications of OOBP, with emphasis on their phenolic content as natural antioxidants for food applications. Key findings and conclusions Besides their antioxidant activity, phenolic compounds from OOBP have also shown antimicrobial and antitumoral properties. Their application as food antioxidants requires new extraction techniques, including the use of non-toxic solvents and, in a pilot scale, the use of filters and adsorbent resins. The inclusion of phenolic compounds from OOBP in some food matrices have improved not only their antioxidant capacity but also their sensory attributes.