928 resultados para MACROSCOPIC QUANTUM PHENOMENA IN MAGNETIC SYSTEMS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

At head of title: Office of Naval Research. Contract N6 onr 243. Task order IV. Technical report no. 2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"NSF workshop."--Cover.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Unclassified."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Office of Naval Research. Contract ONR 243. Task order V. Technical report no. 1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

v. 1 issued October 1977 ; v. 2 issued May 1978.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Part I of the present paper was supported by the Arnold Engineering Development Center under Contract no. AF-40-(601)-928. Part II is a part of project DEFENDER sponsored by the Advanced Research Projects Agency, Department of Defense, under Contract no. DA-30-069-ORD-3443."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Originally issued, December 4, 1936. Revised, December 10, 1937."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We define several quantitative measures of the robustness of a quantum gate against noise. Exact analytic expressions for the robustness against depolarizing noise are obtained for all bipartite unitary quantum gates, and it is found that the controlled-NOT gate is the most robust two-qubit quantum gate, in the sense that it is the quantum gate which can tolerate the most depolarizing noise and still generate entanglement. Our results enable us to place several analytic upper bounds on the value of the threshold for quantum computation, with the best bound in the most pessimistic error model being p(th)less than or equal to0.5.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Particle flow patterns were investigated for wet granulation and dry powder mixing in ploughshare mixers using Positron Emission Particle Tracking (PEPT). In a 4-1 mixer, calcium carbonate with mean size 45 mum was granulated using a 50 wt.% solution of glycerol and water as binding fluid, and particle movement was followed using a 600-mum calcium hydroxy-phosphate tracer particle. In a 20-1 mixer, dry powder flow was studied using a 600-mum resin bead tracer particle to simulate the bulk polypropylene powder with mean size 600 mum. Important differences were seen between particle flow patterns for wet and dry systems. Particle speed relative to blade speed was lower in the wet system than in the dry system, with the ratios of average particle speed to blade tip speed for all experiments in the range 0.01-015. In the axial plane, the same particle motion was observed around each blade; this provides a significant advance for modelling flow in ploughshare mixers. For the future, a detailed understanding of the local velocity, acceleration and density variations around a plough blade will reveal the effects of flow patterns in granulating systems on the resultant distribution of granular product attributes such as size, density and strength. (C) 2002 Elsevier Science B.V All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A semiconductor based scheme has been proposed for generating entangled photon pairs from the radiative decay of an electrically pumped biexciton in a quantum dot. Symmetric dots produce polarization entanglement, but experimentally realized asymmetric dots produce photons entangled in both polarization and frequency. In this work, we investigate the possibility of erasing the “which-path” information contained in the frequencies of the photons produced by asymmetric quantum dots to recover polarization-entangled photons. We consider a biexciton with nondegenerate intermediate excitonic states in a leaky optical cavity with pairs of degenerate cavity modes close to the nondegenerate exciton transition frequencies. An open quantum system approach is used to compute the polarization entanglement of the two-photon state after it escapes from the cavity, measured by the visibility of two-photon interference fringes. We explicitly relate the two-photon visibility to the degree of the Bell-inequality violation, deriving a threshold at which Bell-inequality violations will be observed. Our results show that an ideal cavity will produce maximally polarization-entangled photon pairs, and even a nonideal cavity will produce partially entangled photon pairs capable of violating a Bell-inequality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A phantom that can be used for mapping geometric distortion in magnetic resonance imaging (MRI) is described. This phantom provides an array of densely distributed control points in three-dimensional (3D) space. These points form the basis of a comprehensive measurement method to correct for geometric distortion in MR images arising principally from gradient field non-linearity and magnet field inhomogeneity. The phantom was designed based on the concept that a point in space can be defined using three orthogonal planes. This novel design approach allows for as many control points as desired. Employing this novel design, a highly accurate method has been developed that enables the positions of the control points to be measured to sub-voxel accuracy. The phantom described in this paper was constructed to fit into a body coil of a MRI scanner, (external dimensions of the phantom were: 310 mm x 310 mm x 310 mm), and it contained 10,830 control points. With this phantom, the mean errors in the measured coordinates of the control points were on the order of 0.1 mm or less, which were less than one tenth of the voxel's dimensions of the phantom image. The calculated three-dimensional distortion map, i.e., the differences between the image positions and true positions of the control points, can then be used to compensate for geometric distortion for a full image restoration. It is anticipated that this novel method will have an impact on the applicability of MRI in both clinical and research settings. especially in areas where geometric accuracy is highly required, such as in MR neuro-imaging. (C) 2004 Elsevier Inc. All rights reserved.