843 resultados para Literature and morals.
Resumo:
A 37-m thick layer of stratified clay encountered during a site investigation at Swann's Bridge, near the sea-coast at Limavady, Northern Ireland, is one of the deepest and thickest layers of this type of material recorded in Ireland. A study of the relevant literature and stratigraphic evidence obtained from the site investigation showed that despite being close to the current shoreline, the clay was deposited in a fresh-water glacial lake formed approximately 13 000 BP. The 37-m layer of clay can be divided into two separate zones. The lower zone was deposited as a series of laminated layers of sand, silt, and clay, whereas the upper zone was deposited as a largely homogeneous mixture. A comprehensive series of tests was carried out on carefully selected samples from the full thickness of the deposit. The results obtained from these tests were complex and confusing, particularly the results of tests done on samples from the lower zone. The results of one-dimensional compression tests, unconsolidated undrained triaxial tests, and consolidated undrained triaxial compression tests showed that despite careful sampling, all of the specimens from the lower zone exhibited behaviour similar to that of reconstituted clays. It was immediately clear that the results needed explanation. This paper studies possible causes of the results from tests carried out on the lower Limavady clay. It suggests a possible mechanism based on anisotropic elasticity, yielding, and destructuring that provides an understanding of the observed behaviour.Key words: clay, laminations, disturbance, yielding, destructuring, reconstituted.
Resumo:
Energies of the 54 levels belonging to the (1s(2)2s(2)2p(6)) 3s(2)3p(5), 3s3p(6), 3s(2)3p(4)3d and 3s3p(5)3d configurations of Fe X have been calculated using the GRASP code of Dyall et al. (1989). Additionally, radiative rates, oscillator strengths, and line strengths are calculated for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) transitions among these levels. Comparisons are made with results available in the literature, and the accuracy of the data is assessed. Our energy levels are estimated to be accurate to better than 3%, whereas results for other parameters are probably accurate to better than 20%. Additionally, the agreement between measured and calculated lifetimes is better than 10%.
Resumo:
Energy levels and radiative rates have been calculated for fine-structure transitions among the lowest 89 levels of the (1s(2)) 2s(2)2p(6), 2s(2) 2p(5) 3 l, 2s(2) 2p(5) 4l, 2s2p(6) 3 l, and 2s2p(6)4l configurations of Fe XVII using the GRASP code of Dyall et al. Collision strengths have also been calculated, for transitions among the lowest 55 levels, using the recently developed Dirac atomic R-matrix code (DARC) of Norrington & Grant. The results are compared with those available in the literature, and the accuracy of the data is assessed.
Resumo:
Energies for 524 levels of Ar XIII, 460 levels of Ar XIV and 156 levels of Ar XV have been calculated using the GRASP code of Dyall et al. (1989). Additionally, radiative rates, oscillator strengths, and line strengths are calculated for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) transitions among these levels. Comparisons are made with the limited results available in the literature, and the accuracy of the data is assessed. Our energy levels are estimated to be accurate to better than 1%, whereas results for other parameters are probably accurate to better than 20%. Additionally, the level lifetimes derived from our radiative rates are in excellent agreement with measured values.
Resumo:
Energy levels and radiative rates for transitions among the 107 finestructure levels belonging to the (1s(2)2s(2)2p(6)) 3s(2)3p(6)3d(10), 3s(2)3p(6)3d(9)4l, 3s(2)3p(5)3d(10)4l, and 3s3p(6)3d(10)4l configurations of Ni-like ions with 60 less than or equal to Z less than or equal to 90 have been calculated using the GRASP code. The collision strengths (Omega) have also been computed for transitions in Gd XXXVII at energies below 800 Ryd, using the DARC code. Resonances have been resolved in a fine energy mesh in the threshold region, and excitation rate coefficients have been calculated for transitions from the ground level to excited levels at temperatures below 2500 eV. These have been compared with those available in the literature, and enhancement in the values of rates, due to resonances, has been observed up to an order of magnitude for some of the transitions.
Resumo:
Background: Children born by Caesarean section have modified intestinal bacterial colonization and consequently may have an increased risk of developing asthma under the hygiene hypothesis. The results of previous studies that have investigated the association between Caesarean section and asthma have been conflicting.
Objective: To review published literature and perform a meta-analysis summarizing the evidence in support of an association between children born by Caesarean section and asthma.
Methods: MEDLINE, Web Science, Google Scholar and PubMed were searched to identify relevant studies. Odds ratio (OR) and 95% confidence interval (CI) were calculated for each study from the reported prevalence of asthma in children born by Caesarean section and in control children. Meta-analysis was then used to derive a combined OR and test for heterogeneity in the findings between studies.
Results: Twenty-three studies were identified. The overall meta-analysis revealed an increase in the risk of asthma in children delivered by Caesarean section (OR=1.22, 95% CI 1.14, 1.29). However, in this analysis, there was evidence of heterogeneity (I2=46%) that was statistically significant (P<0.001). Restricting the analysis to childhood studies, this heterogeneity was markedly decreased (I2=32%) and no longer attained statistical significance (P=0.08). In these studies, there was also evidence of an increase (P<0.001) in the risk of asthma after Caesarean section (OR=1.20, 95% CI 1.14, 12.6).
Conclusion: In this meta-analysis, we found a 20% increase in the subsequent risk of asthma in children who had been delivered by Caesarean section.
Effect of Water on the Electrochemical Window and Potential Limits of Room-Temperature Ionic Liquids
Resumo:
The effect of water content on room-temperature ionic liquids (RTILs) was studied by Karl Fischer titration and cyclic voltammetry in the following ionic liquids: tris(P-hexyl)tetradecylphosphonium trifluorotris(pentafluoroethyl)phosphate [P-14,P-6,P-6,P-6][NTf2], N-butyl-N-methyl-pyrrolidinium bis(trifluoromethylsulfonyl)imide [C(4)mpyrr][NTf2], 1-hexyl-3-methylimidazolium tris(perfluoroethyl)trifluorophosphate [C(6)mim][FAP], 1-butyl3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C(4)mim][NTf2], 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C(4)dmim][NTf2], N-hexyltriethylammonium bis(trifluoromethylsolfonyl)imide [N-6,N-2,N-2,N-2][NTf2], 1-butyl-3-methylirnidazolium hexafluorophosphate [C(4)mim][PF6], F6], 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [C(2)mim][NTf2], 1-butyl-3-methylimidazolium tetrafluoroborate [C(4)mim][BF4], 1-hexyl-3-methylimidazolium iodide [C(4)mim][I], 1-butyl-3-methylimidazolium trifluoromethylsulfonate [C(4)mim][OTf], and 1-hexyl-3-methylimidazolium chloride [C(6)mim][Cl]. In addition, electrochemically relevant properties such as viscosity, conductivity, density, and melting point of RTILs are summarized from previous literature and are discussed. Karl Fisher titrations were carried out to determine the water content of RTILs for vacuum-dried, atmospheric, and wet samples. The anion in particular was found to affect the level of water uptake. The hydrophobicity of the anions adhered to the following trend: [FAP](-) > [NTf2](-) > [PF6](-) > [BF4](-) > halides. Cyclic voltammetry shows that an increase in water content significantly narrows the electrochemical window of each ionic liquid. The electrochemical window decreases in the following order: vacuum-dried > atmospheric > wet at 298 K > 318 K > 338 K. The anodic and cathodic potentials vs ferrocene internal reference are also listed under vacuum-dried and atmospheric conditions. The data obtained may aid the selection of a RTIL for use as a solvent in electrochemical applications.