961 resultados para Line voltage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research was to evaluate the K2O distribution uniformity by surface drip irrigation at Universitat Politecnica de Valencia, Valencia, Spain (39º 29′ N, 0º 23′ W, 20 m). The irrigation was performed by drip lines with not-compensated emitters, spaced 0.3 m. The fertigation was realized using a fertilizer injector pump of electric action with injection of 0.25 h. The experimental design used completely randomized blocks with five treatments and four replications. The treatments consisted of injection in five distances, located at 10; 20; 30; 40; 50 m of the first drip line. Samples were collected in emitters located at the start, at 1/3, at 2/3 and at the end of the drip lines. The nutrient concentration was determined by flame spectrophotometry. The Christiansen's uniformity coefficients (CUC), of distribution (DUC), of statistical (SUC) and of emission (eUC) were estimated. The K2O concentration and distribution decreased linearly with the increase of the injection distance. In all treatments, the CUC, SUC and DUC were described as 'excellent'. The eUC was described as 'recommended' only at smaller injection distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vegetation cover on soil acts positively in maintaining temperature and soil moisture, yet, it has been imposing specific operational conditions on seeders. The objective of this study was to evaluate performance of different mechanisms regarding straw mobilization, employed in a no-till seeder. The experimental area was conducted on clayey soil under no-tillage with a large quantity of sorghum residue. The experiment was established in a randomized block design, as the treatments consisted of a combination of two mechanisms at front of the furrow opener composed of cutting disc and row cleaners, and three mechanisms behind the seed furrower, covering discs prototype model M1, Spider and commercial model, with the combination of cutting disc and Spider model not being evaluated. We assessed the coverage permanence on soil index, vegetation mass on surface and inside the line. The treatment containing the row cleaner mechanism efficiently removed straw from the surface of sowing line as well as the return one acted on straw replacement. It was identified that use of the cutting disc at the front of seeder contributed to the increase of straw installation inside the line, three times more than in the row cleaner system when operating individually. Covering mechanism with row cleaners reduced straw inside the line and kept line covering similar to treatment of cutting disc operating alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Straw on sowing line modifies seed germination environment regarding temperature and water content. Given these considerations, the aim of this study was to evaluate different mechanisms for coverage mobilization on the sowing line and their effect on germination environment of maize seeds, mainly in relation to the dynamics of straw in the seedbed, water content and soil temperature. Treatments consisted on the combination of two mechanisms at front of furrow opener, composed of cutting disc and row cleaners, with three mechanisms behind the seed furrower for returning the soil, consisting of three covering mechanisms, commercial and prototype models. It was found that straw presence on the surface of sowing line contributed to germination of maize seeds, maintenance of temperature and soil water content. The cutting disc treatment, associated with prototype, introduced percentages of water content near the ones in bottom layer, and this soil water content was 29.7% with 93.75% of straw coverage and deeper seeding depth, granting better conditions for seed germination. However, the straw coverage removal on soil by the row cleaners and its low sowing depth caused water loss in the lines resulting in great reduction of the emergence speed index in maize seedlings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main advantage of organic electronics over the more widespread inorganic counterparts lies not in the electrical performance, but rather in the solution processability that opens up for low-cost flexible electronics (e.g. displays, sensors and smart tags) fabricated by using printing techniques. Replacing the commonly used laboratory-scale fabrication techniques with mass-printing techniques is, however, truly challenging, especially when low-voltage operation is required. In this thesis it is, nevertheless, demonstrated that low-voltage organic transistors can be fully printed with a similar performance to that of transistors made by laboratory scale techniques. The use of an ion-modulated type of organic field effect transistor (OFET) not only enabled low-voltage operation and printability, but was also found to result in low sensitivity to the surface roughness of the substrate. This allows not only the use of low-cost plastic substrates, but even the use of paper as a substrate. However, while absorption into the porous paper surface is advantageous in a graphical printing process, by reducing the spreading and the coffee-stain effect and by improving the adhesion, it provides great challenges when applying thin electrically active layers. In spite of these difficulties we were able to demonstrate the first low-voltage OFET to be fabricated on paper. We have also shown that low-cost incandescent lamps can be used for sintering printed metal-nanoparticles, and that the process was especially suitable on paper and compatible with a roll-to-roll manufacturing process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os autores relatam pela primeira vez utilização de uma nova partícula para embolização, constituída de um núcleo de acetato de polivinil revestido por polivinil-álcool, de forma esférica (Spherus®-First Line Brasil), como preparo pré-operatório em três pacientes portadores de neoplasia renal, na intenção de diminuir o tamanho do tumor e prevenir complicações hemorrágicas durante o ato operatório. Estas novas partículas foram projetadas e elaboradas nos laboratórios da COPPE/UFRJ. A embolização intra-arterial pré-operatória com estas novas partículas ocasionou acentuada isquemia em todo o tecido tumoral facilitando o procedimento cirúrgico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fuel cells are a promising alternative for clean and efficient energy production. A fuel cell is probably the most demanding of all distributed generation power sources. It resembles a solar cell in many ways, but sets strict limits to current ripple, common mode voltages and load variations. The typically low output voltage from the fuel cell stack needs to be boosted to a higher voltage level for grid interfacing. Due to the high electrical efficiency of the fuel cell, there is a need for high efficiency power converters, and in the case of low voltage, high current and galvanic isolation, the implementation of such converters is not a trivial task. This thesis presents galvanically isolated DC-DC converter topologies that have favorable characteristics for fuel cell usage and reviews the topologies from the viewpoint of electrical efficiency and cost efficiency. The focus is on evaluating the design issues when considering a single converter module having large current stresses. The dominating loss mechanism in low voltage, high current applications is conduction losses. In the case of MOSFETs, the conduction losses can be efficiently reduced by paralleling, but in the case of diodes, the effectiveness of paralleling depends strongly on the semiconductor material, diode parameters and output configuration. The transformer winding losses can be a major source of losses if the windings are not optimized according to the topology and the operating conditions. Transformer prototyping can be expensive and time consuming, and thus it is preferable to utilize various calculation methods during the design process in order to evaluate the performance of the transformer. This thesis reviews calculation methods for solid wire, litz wire and copper foil winding losses, and in order to evaluate the applicability of the methods, the calculations are compared against measurements and FEM simulations. By selecting a proper calculation method for each winding type, the winding losses can be predicted quite accurately before actually constructing the transformer. The transformer leakage inductance, the amount of which can also be calculated with reasonable accuracy, has a significant impact on the semiconductor switching losses. Therefore, the leakage inductance effects should also be taken into account when considering the overall efficiency of the converter. It is demonstrated in this thesis that although there are some distinctive differences in the loss distributions between the converter topologies, the differences in the overall efficiency can remain within a range of a few percentage points. However, the optimization effort required in order to achieve the high efficiencies is quite different in each topology. In the presence of practical constraints such as manufacturing complexity or cost, the question of topology selection can become crucial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Foi testar a validade e a confiabilidade de uma versão on-line do Female Sexual Function Index (FSFI). MÉTODOS: Uma versão on-line do FSFI foi comparada à versão tradicional, em papel. Para tanto, estudantes de Fisioterapia de três cidades foram alocadas randomicamente em dois grupos - G-pp/ol (n=126) e G-ol/pp (n=147). As mulheres do G-pp/ol responderam ao FSFI do modo tradicional, em papel e caneta, enquanto o G-ol/pp respondeu a uma versão on-line do mesmo questionário. Após 15 dias de intervalo, houve nova coleta, quando o G-pp/ol respondeu a versão on-line enquanto o G-ol/pp respondeu no papel. Todos os dados foram transportados para o software estatístico SPSS. Diferenças demográficas entre os dois grupos foram reveladas pelo teste t de Student ou pelo teste exato de Fischer (IC95%; p>0,05). A associação e a correlação entre as respostas entre G-pp/ol e G-ol/pp durante cada coleta foram acessadas pelo teste t e o coeficiente de Pearson. Estratégia idêntica foi utilizada para as comparações intragrupo. RESULTADOS: Um total de 273 mulheres participou do estudo e 28 (10,2%) desistiram da segunda coleta. Não houve diferenças demográficas entre os grupos. Houve associação entre 15 das 19 questões do FSFI entre os dois grupos, tanto no teste quanto no reteste. A análise intragrupo revelou que todas as questões e os escores do FSFI estiveram associados, mas fracamente correlacionados para um mesmo grupo durante as duas coletas. CONCLUSÃO: A versão on-line do FSFI apresentou validade e confiabilidade aceitáveis quando comparada à versão em papel, o que pode justificar a opção por essa modalidade, especialmente em estudos envolvendo sexualidade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSES: To determine the basic expression of ABC transporters in an epithelial ovarian cancer cell line, and to investigate whether low concentrations of acetaminophen and ibuprofen inhibited the growth of this cell line in vitro. METHODS: TOV-21 G cells were exposed to different concentrations of acetaminophen (1.5 to 15 μg/mL) and ibuprofen (2.0 to 20 μg/mL) for 24 to 48 hours. The cellular growth was assessed using a cell viability assay. Cellular morphology was determined by fluorescence microscopy. The gene expression profile of ABC transporters was determined by assessing a panel including 42 genes of the ABC transporter superfamily. RESULTS: We observed a significant decrease in TOV-21 G cell growth after exposure to 15 μg/mL of acetaminophen for 24 (p=0.02) and 48 hours (p=0.01), or to 20 μg/mL of ibuprofen for 48 hours (p=0.04). Assessing the morphology of TOV-21 G cells did not reveal evidence of extensive apoptosis. TOV-21 G cells had a reduced expression of the genes ABCA1, ABCC3, ABCC4, ABCD3, ABCD4 and ABCE1 within the ABC transporter superfamily. CONCLUSIONS: This study provides in vitro evidence of inhibitory effects of growth in therapeutic concentrations of acetaminophen and ibuprofen on TOV-21 G cells. Additionally, TOV-21 G cells presented a reduced expression of the ABCA1, ABCC3, ABCC4, ABCD3, ABCD4 and ABCE1 transporters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, the DFMA is presented and used for the purpose of having a design for a vertical transfer line that can be easily manufactured and assembled. The design of the transfer line, the major components and drawings are presented. The ease of assembly, the costs of manufacturing and differences between the use of steel structure and aluminum are compared. The ALARA principle is followed to minimize the risk of radiation exposure by the means of locating the test ion sources outside the radioactive area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A VDAC é a proteína mais abundante na membrana mitocondrial externa. Exerce o controle da atividade desta organela através da regulação da troca de metabólitos e tem função crucial no mecanismo de apoptose. Em nosso caso, os estudos dos complexos protéicos, das interações entre a VDAC e outras proteínas presentes no interior do neurônio que auxiliam na manutenção das funções das organelas e da célula, fazem parte da chamada interactômica. O presente estudo determinou o interactoma do complexo protéico Hexoquinase-VDAC-ANT presente em cérebros murino, bovino e aviar. Nosso objetivo foi identificar se as expressões diferenciadas da VDAC1 e VDAC2 verificadas nos cérebros murino, aviar e bovino, estão associadas a diferenças nos interactomas dessas proteínas. Este estudo revelou que as espécies aviar e bovina apresentaram o maior número de complexos protéicos contendo VDACs (5) quando comparadas com os neurônios de rato (1), o que é indicativo de uma cinética diferencial de montagem ou desmontagem do complexo. Além disso, a VDAC mitocondrial neuronal aviar também interage com mais proteínas em relação à VDAC mitocondrial neuronal bovina, o que é resultado de uma composição de subunidades diferenciada. Tais resultados indicam diferenças significativas quanto ao metabolismo energético e apoptótico no cérebro aviar, bovino e murino, existindo interações diferenciais da VDAC no cérebro aviar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä tutkittiin Ruukki Oyj:n suorasammutetusta S960QC-teräksestä valmistetun kuormaakantavan levyjen ristiliitoksen pienahitsien lujuutta, muodonmuutoskykyä ja vaurioitumismekanismia laajaan kokeelliseen aineistoon perustuen. Tärkeimpänä muuttujana koematriisissa olivat eri MAG-hitsausprosessit. Perinteisen kuumakaarihitsauksen vertailukohteena oli Kemppi Oy:n uusi adaptiivinen valokaaren pituutta säätävä WiseFusion-hitsaustoiminto kuuma- ja pulssikaarihitsauksessa. Näiden kolmen hitsausprosessin rinnalla varioitiin erisuuruisia a-mittoja, eri hitsauslisäaineita ja hitsin erikylkisyyttä. Lisäksi juuritunkeuman estämisen vaikutusta hitsien käyttäytymiseen tutkittiin täydentävällä koesarjalla, jossa tunkeuman muodostuminen estettiin levyjen väliin asetetulla volframilevyllä. Työn perimmäisenä tavoitteena oli selvittää syy aiemmassa tutkimuksessa havaitulle pienahitsien vaurioitumiselle leikkautumalla sularajaa pitkin. Sularajan suhteellista pituutta saadaan kasvatettua estämällä hitsin juuritunkeuma ja absoluuttista pituutta saadaan lisää kateettipoikkeaman avulla. Lisäksi tutkimuksessa oli tarkoitus tuoda esille suurlujuusteräksisen liitoksen eri mitoituslähtökohdat (mm. lämmöntuonnin kontrollointi). Tämän vuoksi hitsausparametrit mitattiin jännitteen ja virran hetkellisiin arvoihin perustuen, jolloin kuuma- ja pulssikaarihitsauksen laskennalliset hitsaustehot ovat vertailukelpoisia. Koehitseistä valmistettiin hieet hitsien tarkan geometrian määrittämiseksi ja liitoksen mekaaniset ominaisuudet tutkittiin vetokokeella. Tulosten perusteella sularajavaurio aktivoituu pulssikaarella hitsatuissa koekappaleissa. Tämä aiheutunee pulssi- ja kuumakaarihitsauksen sularajan mikrorakenteiden eroavaisuudesta. Sularajavaurio näyttää huonontavan hitsien muodonmuutoskykyä, mutta jatkokokeita tuloksen verifioimiseksi on tehtävä. S960QC-teräkselle ominaisen pehmenneen vyöhykkeen vaurio ei aktivoitunut, vaikka Ruukin antamat jäähtymisaikasuositukset ylitettiin reilusti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the suitability of the Finnish Defence Forces’ NH90 helicopter for parachuting operations with the T-10 static line parachute system. The work was based on the Army Command’s need to compensate for the reduction in the outsourced flight hours for the military static line parachuting training. The aim of the research was to find out the procedures and limitations with which the NH90 IOC+ or FOC version helicopter could be used for static line parachutist training with the T-10B/MC1-1C parachutes. The research area was highly complicated and non-linear. Thus analytical methods could not be applied with sufficient confidence, even with present-day computing power. Therefore an empirical research method was selected, concentrating on flight testing supported with literature study and some calculated estimations. During three flights and 4.5 flight hours in Utti, Finland on 1720 September 2012, a total of 44 parachute drops were made. These consisted of 16 dummy drops and 28 paratrooper jumps. The test results showed that when equipped with the floor mounted PASI-1 anchor line, the deflector bar of the NHIndustries’ Parachuting Kit and Patria’s floor protection panels the Finnish NH90 variant could be safely used for T-10B/MC1-1C static line parachuting operations from the right cabin door at airspeed range of 5080 KIAS (90–150 km/h). The ceiling mounted anchor lines of the NHI’s Parachuting Kit were not usable with the T-10 system. This was due to the static lines’ unsafe behaviour in slipstream when connected to the cabin ceiling level. In conclusion, the NH90 helicopter can be used to meet the Army Command’s requirement for an additional platform for T-10 static line parachutist training. Material dropping, the effect of additional equipment and jumping from the rear ramp should be further studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä tutkitaan, kuinka pitkää moottorikaapelia on jännitevälipiiritaajuusmuuttajan kanssa mahdollista käyttää niin, että määritellyt reunaehdot vielä toteutuvat. Tavoitteena on tuottaa tietoa myynnille, markkinoinnille, tuotehallinnalle sekä tuoteylläpidolle siitä, miten taajuus-muuttaja toimii pidemmillä moottorikaapeleilla kuin valmistaja suosittelee. Tutkitut moottori-kaapelipituudet olivat 175…1025 metriä ja tutkitut laitteet nimellislähtövirroiltaan 2,4...25 A. Työssä aihetta käsitellään jänniteheijastusten näkökulmasta. Lisäksi tutkitaan moottorikaapelin pituuden vaikutusta taajuusmuuttajan eri komponenttien lämpenemiseen. Taajuusmuuttajan toiminnallisuutta arvioidaan moottorin suunnanvaihtojen avulla sekä turvallista toimintaa oikosulkutestein. Tutkittujen taajuusmuuttajien kohdalla on mahdollista käyttää taajuusmuuttajavalmistajan suositusta pidempiä moottorikaapeleita. Moottoriliittimien ylijännitteitä aiheuttavat jännite-heijastukset eivät aiheuttaneet raja-arvoja ylittäviä huippujännitteitä tutkituilla laitekokoon-panoilla. Myös lämpötilannousu oli maltillista tai jopa vähäistä taajuusmuuttajasta mitatuilla komponenteilla. Moottorisäätö havaittiin toimintakykyiseksi pidemmilläkin moottorikaape-leilla, tosin moottorin vääntömomentti heikkeni moottorikaapelien pituutta kasvatettaessa. Virranmittaus toimi hyvin myös pitkillä kaapeleilla, tuottaen vikalaukaisun kaikissa tehdyissä oikosulkutilanteissa. Moottorin ja taajuusmuuttajan melutaso nousivat moottorikaapelien pi-tuutta kasvatettaessa, vaikkakin moottorin käynti oli tasaista ja katkotonta Moottorikaapelin pituutta voidaan kasvattaa 325 metriin kaikissa tutkituissa laitteissa ilman, että mikään tutkittu ominaisuus vielä olennaisesti heikkenisi. Vielä 525 metrin moottorikaape-leita on mahdollista käyttää, mutta tällöin vääntömomentin tuotto on jo heikompaa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Permanent magnet generators (PMG) represent the cutting edge technology in modern wind mills. The efficiency remains high (over 90%) at partial loads. To improve the machine efficiency even further, every aspect of machine losses has to be analyzed. Additional losses are often given as a certain percentage without providing any detailed information about the actual calculation process; meanwhile, there are many design-dependent losses that have an effect on the total amount of additional losses and that have to be taken into consideration. Additional losses are most often eddy current losses in different parts of the machine. These losses are usually difficult to calculate in the design process. In this doctoral thesis, some additional losses are identified and modeled. Further, suggestions on how to minimize the losses are given. Iron losses can differ significantly between the measured no-load values and the loss values under load. In addition, with embedded magnet rotors, the quadrature-axis armature reaction adds losses to the stator iron by manipulating the harmonic content of the flux. It was, therefore, re-evaluated that in salient pole machines, to minimize the losses and the loss difference between the no-load and load operation, the flux density has to be kept below 1.5 T in the stator yoke, which is the traditional guideline for machine designers. Eddy current losses may occur in the end-winding area and in the support structure of the machine, that is, in the finger plate and the clamping ring. With construction steel, these losses account for 0.08% of the input power of the machine. These losses can be reduced almost to zero by using nonmagnetic stainless steel. In addition, the machine housing may be subjected to eddy current losses if the flux density exceeds 1.5 T in the stator yoke. Winding losses can rise rapidly when high frequencies and 10–15 mm high conductors are used. In general, minimizing the winding losses is simple. For example, it can be done by dividing the conductor into transposed subconductors. However, this comes with the expense of an increase in the DC resistance. In the doctoral thesis, a new method is presented to minimize the winding losses by applying a litz wire with noninsulated strands. The construction is the same as in a normal litz wire but the insulation between the subconductors has been left out. The idea is that the connection is kept weak to prevent harmful eddy currents from flowing. Moreover, the analytical solution for calculating the AC resistance factor of the litz-wire is supplemented by including an end-winding resistance in the analytical solution. A simple measurement device is developed to measure the AC resistance in the windings. In the case of a litz-wire with originally noninsulated strands, vacuum pressure impregnation (VPI) is used to insulate the subconductors. In one of the two cases studied, the VPI affected the AC resistance factor, but in the other case, it did not have any effect. However, more research is needed to determine the effect of the VPI on litz-wire with noninsulated strands. An empirical model is developed to calculate the AC resistance factor of a single-layer formwound winding. The model includes the end-winding length and the number of strands and turns. The end winding includes the circulating current (eddy currents that are traveling through the whole winding between parallel strands) and the main current. The end-winding length also affects the total AC resistance factor.