945 resultados para Integrated operation and maintenance
Resumo:
Passive techniques as an alternative to artificial cooling can bring important energy, environmental, financial, operational and qualitative benefits. However, regions such as the wet tropics can reach high levels of thermal stress in which passive means alone are unable to provide appropriate thermal comfort standards for some parts of the year. Despite a great accumulation of empirical information on the passive performance of houses for either free-running or conditioned modes, very little work has been done on the thermal performance of buildings that can operate with a mixed-running strategy in warm-humid climates. Buildings with such design features are able to balance the needs for comfort, privacy, and energy efficiency during different periods of the year. As free-running and conditioned modes are believed by many to be 'opposite' approaches, and have been presented as separate strategies, this paper demonstrates that not all parameters are directly opposite and a possible dual-mode integrated operation can be used for warm-humid locations for maximum comfort and minimum energy requirements. For this purpose, simulation runs using ESP-R (University of Strathclyde, ESRU, UK) were based on the climate data of Darwin (Australia) and on the ventilation styles of the house: free running and conditioned. Design features applicable to both, i.e. for a dual mode operation could be identified and the differences between conditioned and free running were demonstrated and proved not to be totally conflicting and therefore suitable for a dual mode operation. Different daily usage profiles (five use patterns were defined), and zoning of sleeping and living areas are presented. The dual mode use patterns compared to the base case house, for all the user possibilities, had improved performances of 17-52%, when compared to the free-running mode and 66-98% when compared to the conditioned mode. Simulation runs using other warm-humid climates (Miami, USA; Sao Luis, Brazil; Kuala Lumpur, Malaysia) were also conducted and compared to the results found for Darwin. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
This paper describes the buckling phenomenon of a tubular truss with unsupported length through a full-scale test and presents a practical computational method for the design of the trusses allowing for the contribution of torsional stiffness against buckling, of which the effect has never been considered previously by others. The current practice for the design of a planar truss has largely been based on the linear elastic approach which cannot allow for the contribution of torsional stiffness and tension members in a structural system against buckling. The over-simplified analytical technique is unable to provide a realistic and an economical design to a structure. In this paper the stability theory is applied to the second-order analysis and design of the structural form, with detailed allowance for the instability and second-order effects in compliance with design code requirements. Finally, the paper demonstrates the application of the proposed method to the stability design of a commonly adopted truss system used in support of glass panels in which lateral bracing members are highly undesirable for economical and aesthetic reasons.
Resumo:
Ouabain increases vascular resistance and may induce hypertension by inhibiting the Na+ pump. The effects of 0.18 and 18 µg/kg, and 1.8 mg/kg ouabain pretreatment on the phenylephrine (PHE; 0.1, 0.25 and 0.5 µg, in bolus)-evoked pressor responses were investigated using anesthetized normotensive (control and uninephrectomized) and hypertensive (1K1C and DOCA-salt treated) rats. Treatment with 18 µg/kg ouabain increased systolic and diastolic blood pressure in all groups studied. However, the magnitude of this increase was larger for the hypertensive 1K1C and DOCA-salt rats than for normotensive animals, while the pressor effect of 0.18 µg/kg ouabain was greater only in DOCA-salt rats. A very large dose (1.8 mg/kg) produced toxic effects on the normotensive control but not on uninephrectomized or 1K1C rats. Rat tail vascular beds were perfused to analyze the effects of 10 nM ouabain on the pressor response to PHE. In all animals, 10 nM ouabain increased the PHE pressor response, but this increase was larger in hypertensive DOCA-salt rats than in normotensive and 1K1C rats. Results suggested that a) increases in diastolic blood pressure induced by 18 µg/kg ouabain were larger in hypertensive than normotensive rats; b) in DOCA-salt rats, smaller ouabain doses had a stronger effect than in other groups; c) hypertensive and uninephrectomized rats were less sensitive to toxic doses of ouabain, and d) after treatment with 10 nM ouabain isolated tail vascular beds from DOCA-salt rats were more sensitive to the pressor effect of PHE than those from normotensive and 1K1C hypertensive rats. These data suggest that very small doses of ouabain, which might produce nanomolar plasma concentrations, enhance pressor reactivity in DOCA-salt hypertensive rats, supporting the idea that endogenous ouabain may contribute to the increase and maintenance of vascular tone in hypertension.
Resumo:
Um sistema de informação para o monitoramento e diagnóstico de desempenho de centrais termelétricas é uma ferramenta capaz de auxiliar no gerenciamento das atividades de manutenção. Portanto, esta dissertação tem por objetivo desenvolver um sistema de informação para o monitoramento e diagnóstico de desempenho termodinâmico em uma central termelétrica equipada com motores de combustão interna, sistema este capaz de ser implementado em uma aplicação em ambiente MS Windows. Neste trabalho, a condição de referência é estabelecida nas condições ISO com base em testes realizados na planta em operação, além de informações técnicas adicionais. Consequentemente, para o diagnóstico, o estado real é corrigido para a condição ISO. Mesmo assim, além do estado de referência definido, para maior confiabilidade dos resultados foi considerada outra base de comparação em função das informações do fabricante. Além disso, como a central termelétrica possui 20 unidades motogeradoras iguais, o sistema de informação desenvolvido mostrou-se prático comparar os parâmetros operacionais entre duas unidades quaisquer, visando uma análise independente da qualidade do modelo de referência.
Resumo:
The progressive aging of the population requires new kinds of social and medical intervention and the availability of different services provided to the elder population. New applications have been developed and some services are now provided at home, allowing the older people to stay home instead of having to stay in hospitals. But an adequate response to the needs of the users will imply a high percentage of use of personal data and information, including the building up and maintenance of user profiles, feeding the systems with the data and information needed for a proactive intervention in scheduling of events in which the user may be involved. Fundamental Rights may be at stake, so a legal analysis must also be considered.
Design of improved rail-to-rail low-distortion and low-stress switches in advanced CMOS technologies
Resumo:
This paper describes the efficient design of an improved and dedicated switched-capacitor (SC) circuit capable of linearizing CMOS switches to allow SC circuits to reach low distortion levels. The described circuit (SC linearization control circuit, SLC) has the advantage over conventional clock-bootstrapping circuits of exhibiting low-stress, since large gate voltages are avoided. This paper presents exhaustive corner simulation results of a SC sample-and-hold (S/H) circuit which employs the proposed and optimized circuits, together with the experimental evaluation of a complete 10-bit ADC utilizing the referred S/H circuit. These results show that the SLC circuits can reduce distortion and increase dynamic linearity above 12 bits for wide input signal bandwidths.
Resumo:
In competitive electricity markets with deep concerns at the efficiency level, demand response programs gain considerable significance. In the same way, distributed generation has gained increasing importance in the operation and planning of power systems. Grid operators and utilities are taking new initiatives, recognizing the value of demand response and of distributed generation for grid reliability and for the enhancement of organized spot market´s efficiency. Grid operators and utilities become able to act in both energy and reserve components of electricity markets. This paper proposes a methodology for a joint dispatch of demand response and distributed generation to provide energy and reserve by a virtual power player that operates a distribution network. The proposed method has been computationally implemented and its application is illustrated in this paper using a 32 bus distribution network with 32 medium voltage consumers.
Resumo:
This paper proposes an energy resources management methodology based on three distinct time horizons: day-ahead scheduling, hour-ahead scheduling, and real-time scheduling. In each scheduling process it is necessary the update of generation and consumption operation and of the storage and electric vehicles storage status. Besides the new operation condition, it is important more accurate forecast values of wind generation and of consumption using results of in short-term and very short-term methods. A case study considering a distribution network with intensive use of distributed generation and electric vehicles is presented.
Resumo:
The increase of distributed generation (DG) has brought about new challenges in electrical networks electricity markets and in DG units operation and management. Several approaches are being developed to manage the emerging potential of DG, such as Virtual Power Players (VPPs), which aggregate DG plants; and Smart Grids, an approach that views generation and associated loads as a subsystem. This paper presents a multi-level negotiation mechanism for Smart Grids optimal operation and negotiation in the electricity markets, considering the advantages of VPPs’ management. The proposed methodology is implemented and tested in MASCEM – a multiagent electricity market simulator, developed to allow deep studies of the interactions between the players that take part in the electricity market negotiations.
Resumo:
The International Agency for Research on Cancer classified formaldehyde as carcinogenic to humans because there is “sufficient epidemiological evidence that it causes nasopharyngeal cancer in humans”. Genes involved in DNA repair and maintenance of genome integrity are critically involved in protecting against mutations that lead to cancer and/or inherited genetic disease. Association studies have recently provided evidence for a link between DNA repair polymorphisms and micronucleus (MN) induction. We used the cytokinesis-block micronucleus (CBMN assay) in peripheral lymphocytes and MN test in buccal cells to investigate the effects of XRCC3 Thr241Met, ADH5 Val309Ile, and Asp353Glu polymorphisms on the frequency of genotoxicity biomarkers in individuals occupationally exposed to formaldehyde (n = 54) and unexposed workers (n = 82). XRCC3 participates in DNA double-strand break/recombination repair, while ADH5 is an important component of cellular metabolism for the elimination of formaldehyde. Exposed workers had significantly higher frequencies (P < 0.01) than controls for all genotoxicity biomarkers evaluated in this study. Moreover, there were significant associations between XRCC3 genotypes and nuclear buds, namely XRCC3 Met/Met (OR = 3.975, CI 1.053–14.998, P = 0.042) and XRCC3 Thr/Met (OR = 5.632, CI 1.673–18.961, P = 0.005) in comparison with XRCC3 Thr/Thr. ADH5 polymorphisms did not show significant effects. This study highlights the importance of integrating genotoxicity biomarkers and genetic polymorphisms in human biomonitoring studies.
Resumo:
Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia
Resumo:
Os hospitais necessitam de desenvolver programas de gestão de equipamentos médicos, onde contenha informação pertinente e uma metodologia de planeamento eficaz, para a aquisição do equipamento médico novo, assim como otimizar o controlo metrológico destes equipamentos. Para tal foi fornecida informação sobre os aspetos mais relevantes a ter em conta na compra do equipamento médico, como as especificações e funcionalidades necessárias, normas a que o equipamento deve obedecer, garantias, manutenção e calibração/verificação quando aplicável. A escolha dos equipamentos médicos incidiu sobre os esfigmomanómetros e os monitores de sinais vitais. Estudou-se o funcionamento destes equipamentos e prosseguiu-se depois para a realização de entrevistas aos seus utilizadores, com o intuito de perceber a satisfação, os critérios e as necessidades relativas aos equipamentos existentes na ULSM. Em seguida foram realizadas as fichas de normalização onde se definiram as características físicas, fisiológicas e tecnológicas associadas a ambos os tipos de dispositivos médicos. Posteriormente estudaram-se as normas com as quais os equipamentos devem estar em conformidade para garantir o bom funcionamento. Por fim pesquisou-se quais os requisitos metrológicos, técnicos e os procedimentos de verificação a que os equipamentos devem obedecer. Este documento irá servir como suporte para a aquisição e controlo dos equipamentos médicos aqui estudados, melhorando a sua gestão, manutenção e controlo metrológico.
Resumo:
O trabalho presente nesta dissertação incidiu sobre a aplicação das metodologias Lean no âmbito da manutenção de uma empresa metalomecânica de produção de Moldes – Simoldes Aços. No atual enquadramento, com os mercados nacionais e internacionais debaixo de feroz competição, as empresas são obrigadas a estudar métodos e técnicas que permitam eliminar desperdícios, reduzir custos e tempos de produção, ao mesmo tempo que são exigidos maiores níveis de qualidade dos produtos fabricados com vista ao aumento da competitividade. Sendo a Manutenção uma área funcional com um impacto elevado no desempenho da produção, é percebido que o desempenho desta, tem influência direta no comportamento do fluxo produtivo e nos respetivos níveis de eficácia e eficiência. No decorrer do trabalho desta dissertação de mestrado foi realizada uma análise abrangente do estado atual do sector de atividade de manutenção na empresa SIMOLDES SA, o que permitiu identificar as áreas e os pontos a intervir e desenhar as soluções de melhoria na atividade de manutenção. Na fase concludente do trabalho foram implementadas algumas dessas propostas de melhoria, ao passo que outras ficaram agendadas para futura implementação. Na base do trabalho desenvolvido esteve a metodologia Lean, que apresenta um papel relevante na implementação de uma abordagem integrada da função manutenção na manutenção dos objetivos da produção. O presente projeto baseou a sua estratégia de implementação na aplicação da ferramenta do 5S’ em paralelo com o TPM (Total Productive Maintenance). Ambas as ferramentas visam a redução de desperdícios e o aumento da fiabilidade dos processos, pelo aumento da disponibilidade dos equipamentos, da melhoria do desempenho dos processos e da plena integração de todos os colaboradores no processo de fabrico. Com a implementação das melhorias propostas, foram observados melhorias significativas no fluxo das atividades da manutenção, assim como uma maior visibilidade das mesmas em todo o processo produtivo.
Resumo:
In spite of the significant amount of scientific work in Wireless Sensor Networks (WSNs), there is a clear lack of effective, feasible and usable WSN system architectures that address both functional and non-functional requirements in an integrated fashion. This poster abstract outlines the EMMON system architecture for large-scale, dense, real-time embedded monitoring. EMMON relies on a hierarchical network architecture together with integrated middleware and command&control mechanisms. It has been designed to use standard commercially– available technologies, while maintaining as much flexibility as possible to meet specific applications’ requirements. The EMMON WSN architecture has been validated through extensive simulation and experimental evaluation, including through a 300+ node test-bed, the largest WSN test-bed in Europe to date
Resumo:
Wireless sensor networks (WSNs) have attracted growing interest in the last decade as an infrastructure to support a diversity of ubiquitous computing and cyber-physical systems. However, most research work has focused on protocols or on specific applications. As a result, there remains a clear lack of effective and usable WSN system architectures that address both functional and non-functional requirements in an integrated fashion. This poster outlines the EMMON system architecture for large-scale, dense, real-time embedded monitoring. It provides a hierarchical communication architecture together with integrated middleware and command and control software. It has been designed to maintain as much as flexibility as possible while meeting specific applications requirements. EMMON has been validated through extensive analytical, simulation and experimental evaluations, including through a 300+ nodes test-bed the largest single-site WSN test-bed in Europe.