938 resultados para Injection pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The push for improved fuel economy and reduced emissions has led to great achievements in engine performance and control. These achievements have increased the efficiency and power density of gasoline engines dramatically in the last two decades. With the added power density, thermal management of the engine has become increasingly important. Therefore it is critical to have accurate temperature and heat transfer models as well as data to validate them. With the recent adoption of the 2025 Corporate Average Fuel Economy(CAFE) standard, there has been a push to improve the thermal efficiency of internal combustion engines even further. Lean and dilute combustion regimes along with waste heat recovery systems are being explored as options for improving efficiency. In order to understand how these technologies will impact engine performance and each other, this research sought to analyze the engine from both a 1st law energy balance perspective, as well as from a 2nd law exergy analysis. This research also provided insights into the effects of various parameters on in-cylinder temperatures and heat transfer as well as provides data for validation of other models. It was found that the engine load was the dominant factor for the energy distribution, with higher loads resulting in lower coolant heat transfer and higher brake work and exhaust energy. From an exergy perspective, the exhaust system provided the best waste heat recovery potential due to its significantly higher temperatures compared to the cooling circuit. EGR and lean combustion both resulted in lower combustion chamber and exhaust temperatures; however, in most cases the increased flow rates resulted in a net increase in the energy in the exhaust. The exhaust exergy, on the other hand, was either increased or decreased depending on the location in the exhaust system and the other operating conditions. The effects of dilution from lean operation and EGR were compared using a dilution ratio, and the results showed that lean operation resulted in a larger increase in efficiency than the same amount of dilution with EGR. Finally, a method for identifying fuel spray impingement from piston surface temperature measurements was found. Note: The material contained in this section is planned for submission as part of a journal article and/or conference paper in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental work and analysis was done to investigate engine startup robustness and emissions of a flex-fuel spark ignition (SI) direct injection (DI) engine. The vaporization and other characteristics of ethanol fuel blends present a challenge at engine startup. Strategies to reduce the enrichment requirements for the first engine startup cycle and emissions for the second and third fired cycle at 25°C ± 1°C engine and intake air temperature were investigated. Research work was conducted on a single cylinder SIDI engine with gasoline and E85 fuels, to study the effect on first fired cycle of engine startup. Piston configurations that included a compression ratio change (11 vs 15.5) and piston geometry change (flattop vs bowl) were tested, along with changes in intake cam timing (95,110,125) and fuel pressure (0.4 MPa vs 3 MPa). The goal was to replicate the engine speed, manifold pressure, fuel pressure and testing temperature from an engine startup trace for investigating the first fired cycle for the engine. Results showed bowl piston was able to enable lower equivalence ratio engine starts with gasoline fuel, while also showing lower IMEP at the same equivalence ratio compared to flat top piston. With E85, bowl piston showed reduced IMEP as compression ratio increased at the same equivalence ratio. A preference for constant intake valve timing across fuels seemed to indicate that flattop piston might be a good flex-fuel piston. Significant improvements were seen with higher CR bowl piston with high fuel pressure starts, but showed no improvement with low fuel pressures. Simulation work was conducted to analyze initial three cycles of engine startup in GT-POWER for the same set of hardware used in the experimentations. A steady state validated model was modified for startup conditions. The results of which allowed an understanding of the relative residual levels and IMEP at the test points in the cam phasing space. This allowed selecting additional test points that enable use of higher residual levels, eliminating those with smaller trapped mass incapable of producing required IMEP for proper engine turnover. The second phase of experimental testing results for 2nd and 3rd startup cycle revealed both E10 and E85 prefer the same SOI of 240°bTDC at second and third startup cycle for the flat top piston and high injection pressures. E85 fuel optimal cam timing for startup showed that it tolerates more residuals compared to E10 fuel. Higher internal residuals drives down the Ø requirement for both fuels up to their combustion stability limit, this is thought to be direct benefit to vaporization due to increased cycle start temperature. Benefits are shown for an advance IMOP and retarded EMOP strategy at engine startup. Overall the amount of residuals preferred by an engine for E10 fuel at startup is thought to be constant across engine speed, thus could enable easier selection of optimized cam positions across the startup speeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to determine anticoagulation strategies in OPCAB a questionnaire survey among 750 European cardio-thoracic surgeons was performed. Questions addressed volume of OPCAB procedures performed, intra- and perioperative heparinization and antiplatelet therapy, as well as perioperative management. A total of 325 (43.7%) questionnaires were returned and validated. Perioperative protocols for administration of antiplatelets differed among the respondent surgeons. Perioperative prophylaxis of thrombosis (low or high molecular weight heparin) is performed by 78%. Intraoperative heparin dosage range between 70 U/kg to 500 U/kg, 60% of respondents prefer a low-dose regimen (< or = 150 U/kg). Correspondingly, the lowest activated clotting time (ACT) during surgery is accepted to be 200 s by 24%, 250 s by 18% and 300 s by 26% of surgeons. Protamine is used by 91% of respondents, while 52% perform a 1:1 reversal. A cell-saver and antifibrinolytics are used by 70% and 40%, respectively. Interestingly, 56% of respondents think bleeding in OPCAB patients is not reduced when compared to on-pump CABG. In addition, 34% of respondents believe there is an increased risk of early graft occlusion following OPCAB. This survey demonstrates widely different intra- and perioperative anticoagulation strategies for OPCAB procedures among European surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteolytic lesions of the spine (metastasis, myeloma) can be treated extremely efficiently by percutaneous cement injection. The treatment should be restricted to osteolytic lesions of the vertebral body, and only if a relevant mechanical deterioration is present. If the pedicles and/or the lamina are involved and if there is compression of the spinal canal, the treatment is no longer appropriate. The surgical technique is similar to the treatment of osteoporotic fractures; however, there is definitely a higher risk for cement leakage and the clinical outcome is not as predictable as in osteoporotic fracture treatment. It is important to realize that cement injection per se has no impact on the tumor itself, but provides stability to the vertebral body. An osteolytic lesion without mechanical compromise does not need a vertebroplasty. Patients with tumorous lesions of the spine should be followed by an interdisciplinary team of spine surgeon, oncologist and radio-oncologist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous vertebroplasty, comprising of the injection of polymethylmethacrylate (PMMA) into vertebral bodies, is an efficient procedure to stabilize osteoporotic compression fractures as well as other weakening lesions. Besides fat embolism, cement leakage is considered to be one of the major and most severe complications during percutaneous vertebroplasty. The viscosity of the PMMA during injection plays a key role in this context. It was shown in vitro that the best way to lower the risk of cement leakage is to inject the cement at higher viscosity, which is requires high injection forces. Injection forces can be reduced by applying a newly developed lavage technique as it was shown in vitro using human cadaver vertebrae. The purpose of this study was to prove the in vitro results in an in vivo model. The investigation was incorporated in an animal study that was performed to evaluate the cardiovascular reaction on cement augmentation using the lavage technique. Injection forces were measured with instrumentation for 1 cc syringes, additionally acquiring plunger displacement. Averaged injection forces measured, ranged from 12 to 130 N and from 28 to 140 N for the lavage group and the control group, respectively. Normalized injection forces (by viscosity and injection speed) showed a trend to be lower for the lavage group in comparison to the control group (P = 0.073). In conclusion, the clinical relevance on the investigated lavage technique concerning lowering injection forces was only shown by trend in the performed animal study. However, it might well be that the effect is more pronounced for osteoporotic vertebral bodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate whether intravaginal application of seminal plasma at the time of follicle aspiration in IVF or intracytoplasmic sperm injection treatment cycles has the potential to increase pregnancy rate. To calculate the number of patients needed to achieve significance in a multicenter trial. DESIGN: Double-blind, placebo-controlled randomized pilot study. SETTING: University department of gynecological endocrinology and reproductive medicine. PATIENT(S): One hundred sixty-eight patients undergoing IVF or intracytoplasmic sperm injection treatment. INTERVENTION(S): Cryopreserved seminal plasma from the patient's partner or sodium chloride (placebo) was injected into the cervix and the posterior fornix of the vagina just after follicle aspiration. MAIN OUTCOME MEASURE(S): Clinical-pregnancy rate. RESULT(S): One hundred sixty-eight patients agreed to participate in the study. Participation was limited to one treatment cycle. Thirty-one patients (18%) were excluded from the study, mainly as a result of canceled embryo transfers. Seventy patients received placebo, and 67 received seminal plasma. The clinical-pregnancy rate was 25.7% (18/70) in the placebo group. The clinical-pregnancy rate in the seminal plasma group reached 37.3% (25/67), corresponding to a relative increase of 45%. CONCLUSION(S): Even though significance was not reached in this pilot study, the data suggest that seminal plasma has the potential to improve pregnancy rate. It is estimated that around 450 patients need to be recruited to reach significance in a multicenter study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: This study analyzes the effects on coagulation and fibrinolysis comparing off-pump coronary artery bypass (OPCAB) and on-pump CABG operations. METHODS: In a prospective, nonrandomized, comparative evaluation, patients scheduled for elective myocardial revascularization were studied. Due to possible confounding factors patients with postoperative retransfusion of mediastinal shed blood were excluded. Nine patients underwent OPCAB operation and 16 underwent on-pump CABG. Activated clotting time (ACT) was adjusted to 250 seconds in OPCAB (81 +/- 18 [mean +/- SD] IU/kg heparin) and to more than 480 seconds in on-pump CABG (400 IU/kg heparin, additional 10,000 IU in pump prime). Perioperatively blood samples were collected and hematologic and hemostatic variables including fibrinopeptide A (FPA), fibrin monomer (FM), thrombin-antithrombin complex (TAT), and D-dimer were analyzed. RESULTS: Both groups showed comparable demographic variables. Number of grafts per patient was slightly higher in the on-pump group (3.6 +/- 0.6 versus 3.0 +/- 1.1, p = 0.23). The FPA levels did not differ significantly between the groups. The FM, TAT, and D-dimer values were significantly higher in on-pump CABG (p < 0.0001, p < 0.01, and p < 0.0001, respectively), reflecting increased coagulant and fibrinolytic activity. This was also the case when values were corrected for hemodilution. CONCLUSIONS: Despite lower systemic anticoagulation activation of coagulation and fibrinolysis is reduced in OPCAB compared with on-pump CABG. Reduced thrombin generation and reduced fibrinolytic activity in OPCAB indicates better preservation of hemostasis. We suggest the term "preserved hemostasis" instead of "hypercoagulant activity" with respect to OPCAB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We documented the effects of intradetrusor injections of botulinum neurotoxin type A (Botox(R)) for refractory idiopathic detrusor overactivity so that prospective patients maybe properly informed about possible improvement in quality of life, the duration of interinjection intervals and the risk of clean intermittent self-catheterization. MATERIALS AND METHODS: A total of 81 consecutive patients with refractory idiopathic detrusor overactivity treated with intradetrusor injections of 200 U botulinum neurotoxin type A at 20 sites per injection course were evaluated in this prospective, nonrandomized, open label cohort study. The primary outcome was changes in quality of life, as assessed by the short form of the Urogenital Distress Inventory and the Incontinence Impact Questionnaire before and after treatment. Secondary outcomes were the interinjection interval and the need for clean intermittent self-catheterization. RESULTS: After intradetrusor botulinum neurotoxin type A injections there was significant improvement in quality of life, which was sustained after repeat injections. Mean Urogenital Distress Inventory and Incontinence Impact Questionnaire scores decreased from 56 to 26 and 59 to 21 after injection 1 in 81 patients, from 52 to 30 and 51 to 24 after injection 2 in 24, from 40 to 19 and 43 to 17 after injection 3 in 13, from 44 to 17 and 61 to 15 after injection 4 in 6 and from 51 to 17 and 63 to 14 after injection 5 in 4, respectively. The median interinjection interval was 15, 12, 14 and 13 months between injections 1 and 2, 2 and 3, 3 and 4, and 4 and 5, respectively. Considering a post-void residual urine of greater than 100 ml with lower urinary tract symptoms as the indication for clean intermittent self-catheterization, the overall clean intermittent self-catheterization rate after treatment was 43%. CONCLUSIONS: Intradetrusor botulinum neurotoxin type A injections for refractory idiopathic detrusor overactivity significantly improved quality of life. This effect was sustained after repeat injection. More than 2 of 5 patients with refractory idiopathic detrusor overactivity required clean intermittent self-catheterization after botulinum neurotoxin type A injections and all prospective patients should be informed about this.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to compare a standard peripheral end-hole angiocatheter with those modified with side holes or side slits using experimental optical techniques to qualitatively compare the contrast material exit jets and using numeric techniques to provide flow visualization and quantitative comparisons. MATERIALS AND METHODS: A Schlieren imaging system was used to visualize the angiocatheter exit jet fluid dynamics at two different flow rates. Catheters were modified by drilling through-and-through side holes or by cutting slits into the catheters. A commercial computational fluid dynamics package was used to calculate numeric results for various vessel diameters and catheter orientations. RESULTS: Experimental images showed that modifying standard peripheral IV angiocatheters with side holes or side slits qualitatively changed the overall flow field and caused the exiting jet to become less well defined. Numeric calculations showed that the addition of side holes or slits resulted in a 9-30% reduction of the velocity of contrast material exiting the end hole of the angiocatheter. With the catheter tip directed obliquely to the wall, the maximum wall shear stress was always highest for the unmodified catheter and was always lowest for the four-side-slit catheter. CONCLUSION: Modified angiocatheters may have the potential to reduce extravasation events in patients by reducing vessel wall shear stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.