901 resultados para Housing -- Heating and ventilation
Resumo:
Free range egg producers face continuing problems from injurious pecking (IP) which has financial consequences for farmers and poor welfare implications for birds. Beak trimming has been practised for many years to limit the damage caused by IP, but with the UK Government giving notification that they intend to ban beak trimming in 2016, considerable efforts have been made to devise feasible housing, range and management strategies to reduce IP. A recent research project investigated the efficacy of a range of IP reducing management strategies, the mean costs of which came to around 5 pence per bird. Here, the results of the above project’s consumer survey are presented: consumers’ attitudes to free range egg production are detailed showing that, whilst consumers had a very positive attitude towards free range eggs, they were especially uninformed about some aspects of free range egg production. The contingent valuation technique was used to estimate the price premium consumers would be prepared to pay to ensure that hens do not suffer from IP: this was calculated as just over 3% on top of the prevailing retail price of free range eggs. These findings reinforce other studies that have found that whilst consumers are not generally well-informed about certain specific welfare problems faced by animals under free range conditions, they are prepared to pay to improve animal welfare. Indeed, the study findings suggest that producers could obtain an additional price premium if they demonstrate the welfare provenance of their eggs, perhaps through marketing the eggs as coming from birds with intact beaks. This welfare provenance issue could usefully be assured to consumers by the introduction of a mandatory, single, accredited EU-wide welfare-standards labelling scheme.
Resumo:
The building industry is often berated for its short comings in meeting up with the demand for the provision of new housing. Addressing the need for new housing stock is a challenge that has led to debates among professional bodies, the construction sector, housing industry and government. The introduction of new manufacturing technologies is often offered as a solution, but the challenges of increasing the amount of off-site construction in residential building are well known and well-rehearsed. The modern flying factory (MFF) is a concept that involves the manufacture of specific components or modules in temporary off- or near- site locations using relatively simple and quick to set up and dismantle technologies and processes. The aim is to produce short batches and hence achieve some of the benefits of off-site manufacture on a much smaller scale than in dedicated factory environments. A case study of a modern flying factory being set up to produce pre-assembled utility cupboards for a large residential development in London is presented, involving participant observation and informal interviews with key actors on the design and operationalising of the process. The case reveals that although there are costs, efficiency and health and safety benefits to using MFF approaches, there are also challenges to overcome over the time required to set up and establish the process for relatively short runs, and in evaluating whether the MFF or traditional site based production is most effective for particular aspects of projects.
Resumo:
A general circulation model of intermediate complexity with an idealized Earth-like aquaplanet setup is used to study the impact of changes in the oceanic heat transport on the global atmospheric circulation. Focus is on the atmospheric mean meridional circulation and global thermodynamic properties. The atmosphere counterbalances to a large extent the imposed changes in the oceanic heat transport, but, nonetheless, significant modifications to the atmospheric general circulation are found. Increasing the strength of the oceanic heat transport up to 2.5 PW leads to an increase in the global mean near-surface temperature and to a decrease in its equator-to-pole gradient. For stronger transports, the gradient is reduced further, but the global mean remains approximately constant. This is linked to a cooling and a reversal of the temperature gradient in the tropics. Additionally, a stronger oceanic heat transport leads to a decline in the intensity and a poleward shift of the maxima of both the Hadley and Ferrel cells. Changes in zonal mean diabatic heating and friction impact the properties of the Hadley cell, while the behavior of the Ferrel cell is mostly controlled by friction. The efficiency of the climate machine, the intensity of the Lorenz energy cycle and the material entropy production of the system decline with increased oceanic heat transport. This suggests that the climate system becomes less efficient and turns into a state of reduced entropy production as the enhanced oceanic transport performs a stronger large-scale mixing between geophysical fluids with different temperatures, thus reducing the available energy in the climate system and bringing it closer to a state of thermal equilibrium.
Resumo:
Building roofs play a very important role in the energy balance of buildings, especially in summer, when they are hit by a rather high solar irradiance. Depending on the type of finishing layer, roofs can absorb a great amount of heat and reach quite high temperatures on their outermost surface, which determines significant room overheating. However, the use of highly reflective cool materials can help to maintain low outer surface temperatures; this practice may improve indoor thermal comfort and reduce the cooling energy need during the hot season.This technology is currently well known and widely used in the USA, while receiving increasing attention in Europe. In order to investigate the effectiveness of cool roofs as a passive strategy for passive cooling in moderately hot climates, this paper presents the numerical results of a case study based on the dynamic thermal analysis of an existing office building in Catania (southern Italy, Mediterranean area). The results show how the application of a cool paint on the roof can enhance the thermal comfort of the occupants by reducing the operative temperatures of the rooms and to reduce the overall energy needs of the building for space heating and cooling.
Resumo:
One of the fundamental properties of astrophysical magnetic fields is their ability to change topology through reconnection and in doing so, to release magnetic energy, sometimes violently. In this work, we review recent results on the role of magnetic reconnection and associated heating and particle acceleration in jet/accretion disk systems, namely young stellar objects (YSOs), microquasars, and active galactic nuclei (AGNs).
Resumo:
The spectral decomposition analysis was applied to the optical absorption spectra of green and colorless beryl crystals from the Brazilian Eastern Pegmatitic province in the natural state, Submitted to heat treatment and irradiated with UV light The attributions of the lines were made taking into account highly accurate quantum mechanical calculations The deconvolution of the green beryl spectra revealed four lines, two of them around 12,000 cm(-1) (1 5eV) and two of them around 34,000 cm(-1) (4.2 eV) attributed to Fe(2+) and Fe(3+), respectively The deconvolution of the colorless beryl spectra without any treatment, after heating and for the same heat treatment followed by UV light irradiation revealed five lines The analysis of ratio relations showed that the lines at 36,400 cm(-1) (4.5 eV) and 41,400 cm(-1) (5 1 eV) belongs to a single defect attributed to a silicon dangling bond defect (=Si). Discussions and comparison with reported defects in quartz have supported the allocation of the lines at 61,000 cm(-1) (7.6 eV) and 43,800 cm(-1) (5 4 eV) to diamagnetic oxygen vacancy defect ( Si-Si ) and unrelaxed ( Si Si ) defect, respectively Finally, the line at 39.100 cm(-1) (4.8 eV), quite polarized along the c-axis, was attributed to a (Fe(2+) OH(-)) defect in the structural channels (C) 2009 Elsevier B V All rights reserved
Resumo:
Several conditions have been used in the coupling reaction of stepwise SPPS at elevated temperature (SPPS-ET), but we have elected the following as our first choice: 2.5-fold molar excess of 0.04-0.08 M Boc or Fmoc-amino acid derivative, equimolar amount of DIC/HOBt (1:1)or TBTU/DIPEA(1:3), 25% DMSO/toluene, 60 degrees C, conventional heating. In this study, aimed to further examine enantiomerization under such condition and study the applicability of our protocols to microwave-SPPS, peptides containing L-Ser, L-His, L-Cys and/or L-Met were manually synthesized traditionally, at 60 degrees C using conventional heating and at 60 degrees C using microwave heating. Detailed assessment of all crude peptides (in their intact and/or fully hydrolyzed forms) revealed that, except for the microwave-assisted coupling of L-Cys, all other reactions occurred with low levels of amino acid enantiomerization (<2%). Therefore, herein we (i) provide new evidences that our protocols for SPPS at 60 degrees C using conventional heating are suitable for routine use, (ii) demonstrate their appropriateness for microwave-assisted SPPS by Boc and Fmoc chemistries, (iii) disclose advantages and limitations of the three synthetic approaches employed. Thus, this study complements our past research on SPPS-ET and suggests alternative conditions for microwave-assisted SPPS. Copyright (C) 2009 European Peptide Society and John Wiley & Sons, Ltd.
Resumo:
Within the framework of the REBUS project the German building industry has been investigated regarding their energy concepts. The intention was to evaluatethe establishment of renewable energy sources on the German market for new built houses and prefab houses in particular. For this purpose the products of 85manufacturers of prefab houses have been analyzed. Of special interest was the applicationof heating and hot water systems driven by solar energy and biomass. The results show that both techniques are well accepted and established. Almost 90% of themanufacturers offer solar systems on request and almost 70% heating systems based on Pellets. 24% offered solar and 7% as standard options in their range. From theachieved figures the potential of the Swedish market can be worked out. Strategies to introduce renewable energy to a greater extent to Swedish house manufacturers and builders might also be found.
Resumo:
This master thesis presents a new technological combination of two environmentally friendly sources of energy in order to provide DHW, and space heating. Solar energy is used for space heating, and DHW production using PV modules which supply direct current directly to electrical heating elements inside a water storage tank. On the other hand a GSHP system as another source of renewable energy provides heat in the water storage tank of the system in order to provide DHW and space heating. These two sources of renewable energy have been combined in this case-study in order to obtain a more efficient system, which will reduce the amount of electricity consumed by the GSHP system.The key aim of this study is to make simulations, and calculations of the amount ofelectrical energy that can be expected to be produced by a certain amount of PV modules that are already assembled on a house in Vantaa, southern Finland. This energy is then intended to be used as a complement to produce hot water in the heating system of the house beside the original GSHP system. Thus the amount of electrical energy purchased from the grid should be reduced and the compressor in the GSHP would need fewer starts which would reduce the heating cost of the GSHP system for space heating and providing hot water.The produced energy by the PV arrays in three different circuits will be charged directly to three electrical heating elements in the water storage tank of the existing system to satisfy the demand of the heating elements. The excess energy can be used to heat the water in the water storage tank to some extent which leads to a reduction of electricity consumption by the different components of the GSHP system.To increase the efficiency of the existing hybrid system, optimization of different PV configurations have been accomplished, and the results are compared. Optimization of the arrays in southern and western walls shows a DC power increase of 298 kWh/year compared with the existing PV configurations. Comparing the results from the optimization of the arrays on the western roof if the intention is to feed AC power to the components of the GSHP system shows a yearly AC power production of 1,646 kWh.This is with the consideration of no overproduction by the PV modules during the summer months. This means the optimized PV systems will be able to cover a larger part of summer demand compared with the existing system.
Resumo:
The need for heating and cooling in buildings constitutes a considerable part of the total energy use in a country and reducing this need is of outmost importance in order to reach national and international goals for reducing energy use and emissions. One important way of reaching these goals is to increase the proportion of renewable energy used for heating and cooling of buildings. Perhaps the largest obstacle with this is the often occurring mismatch between the availability of renewable energy and the need for heating or cooling, hindering this energy to be used directly. This is one of the problems that can be solved by using thermal energy storage (TES) in order to save the heat or cold from when it is available to when it is needed. This thesis is focusing on the combination of TES techniques and buildings to achieve increased energy efficiency for heating and cooling. Various techniques used for TES as well as the combination of TES in buildings have been investigated and summarized through an extensive literature review. A survey of the Swedish building stock was also performed in order to define building types common in Sweden. Within the scope of this thesis, the survey resulted in the selection of three building types, two single family houses and one office building, out of which the two residential buildings were used in a simulation case study of passive TES with increased thermal mass (both sensible and latent). The second case study presented in the thesis is an evaluation of an existing seasonal borehole storage of solar heat for a residential community. In this case, real measurement data was used in the evaluation and in comparisons with earlier evaluations. The literature reviews showed that using TES opens up potential for reduced energy demand and reduced peak heating and cooling loads as well as possibilities for an increased share of renewable energy to cover the energy demand. By using passive storage through increased thermal mass of a building it is also possible to reduce variations in the indoor temperature and especially reduce excess temperatures during warm periods, which could result in avoiding active cooling in a building that would otherwise need it. The analysis of the combination of TES and building types confirmed that TES has a significant potential for increased energy efficiency in buildings but also highlighted the fact that there is still much research required before some of the technologies can become commercially available. In the simulation case study it was concluded that only a small reduction in heating demand is possible with increased thermal mass, but that the time with indoor temperatures above 24 °C can be reduced by up to 20%. The case study of the borehole storage system showed that although the storage system worked as planned, heat losses in the rest of the system as well as some problems with the system operation resulted in a lower solar fraction than projected. The work presented within this thesis has shown that TES is already used successfully for many building applications (e.g. domestic hot water stores and water tanks for storing solar heat) but that there still is much potential in further use of TES. There are, however, barriers such as a need for more research for some storage technologies as well as storage materials, especially phase change material storage and thermochemical storage.
Resumo:
In a Nordic climate, space heating (SH) and domestic hot water (DHW) used in buildings constitute a considerable part of the total energy use in the country. For 2010, energy used for SH and DHW amounted to almost 90 TWh in Sweden which corresponds to 60 % of the energy used in the residential and service sector, or almost 24 % of the total final energy use for the country. Storing heat and cold with the use of thermal energy storage (TES) can be one way of increasing the energy efficiency of a building by opening up possibilities for alternative sources of heat or cold through a reduced mismatch between supply and demand. Thermal energy storage without the use of specific control systems are said to be passive and different applications using passive TES have been shown to increase energy efficiency and/or reduce power peaks of systems supplying the heating and cooling needs of buildings, as well as having an effect on the indoor climate. Results are however not consistent between studies and focus tend to be on the reduction of cooling energy or cooling power peaks. In this paper, passive TES introduced through an increased thermal mass in the building envelope to two single family houses with different insulation standard is investigated with building energy simulations. A Nordic climate is used and the focus of this study is both on the reduction of space heating demand and space heating power, as well as on reduction of excess temperatures in residential single family houses without active cooling systems. Care is taken to keep the building envelope characteristics other than the thermal mass equal for all cases so that any observations made can be derived to the change in thermal mass. Results show that increasing the sensible thermal mass in a single family house can reduce the heating demand only slightly (1-4 %) and reduce excess temperatures (temperatures above 24 degrees C) by up to 20 %. Adding a layer of PCM (phase change materials) to the light building construction can give similar reduction in heating demand and excess temperatures, however the phase change temperature is important for the results.
Resumo:
REESBE
Resumo:
Este trabalho apresenta uma técnica de programação e controle da construção repetitiva denominada Linha de Balanço. E uma técnica, surgida na indústria fabril, onde a produção em série e em grande escala exige a organização dos métodos de produção e a racionalização do trabalho. O estudo, inicialmente, modela o trabalho de construção de unidades repetitivas, salientando os problemas de organização e administração destes empreendimentos. Num segundo momento, são apresentados os princípios teóricos da técnica com aplicações práticas da programação. Por fim, é analisada a metodologia usual de construção de conjuntos habitacionais através de um estudo de caso e, observadas as condições de aplicação da técnica da Linha de Balanço, não exigindo mudificações muito profundas na atual ação gerencial neste tipo de obra. As conclusões esboçadas confirmam as vantagens da técnica da Linha de Balanço para estes empreendimentos e propõem a sua utilização na organização do trabalho nos canteiros repetitivos.
Resumo:
Introdução: O conhecimento da distribuição da perfusão pulmonar pela cintilografia na bronquiolite viral aguda, pode auxiliar no entendimento das alterações no equilíbrio da ventilação - perfusão, peculiares a essa doença do lactente jovem. Objetivo: Avaliar o padrão de distribuição da perfusão pulmonar em pacientes hospitalizados com bronquiolite viral aguda por meio de cintilografia pulmonar perfusional quantitativa com macroagregado de albumina com tecnécio (99mTc-MAA), estabelecendo associação com as avaliações clínica e radiológica, bem como determinando o seu padrão evolutivo até a condição de normalidade. Tipo de estudo: Dois estudos prospectivos com enfoque diagnóstico: um transversal, comparativo, e um longitudinal, evolutivo, controlado. Pacientes e métodos: A amostra da pesquisa foi constituída por pacientes hospitalizados no Hospital de Clínicas de Porto Alegre com diagnóstico de bronquiolite viral aguda, no período de abril de 1998 a setembro de 2000, baseada em critérios clínicos de inclusão: idade entre 01 e 24 meses, com quadro respiratório obstrutivo de vias aéreas inferiores (primeiro episódio de sibilância expiratória de início súbito, com sinais de coriza, tosse irritativa, hipertermia, taquipnéia, tiragem, batimentos de asa de nariz, esforço expiratório), com gravidade suficiente para determinar a hospitalização e cujos pais aceitaram participar do estudo. Todos os pacientes da pesquisa foram submetidos à avaliação clínica, radiológica e da perfusão pulmonar com o radiofármaco. A cintilografia foi realizada na condição de crise (primeiras 24 horas da admissão) e na convalescência (depois de 7 dias da alta hospitalar). A quantificação do fluxo sangüíneo pulmonar, representada em valores percentuais, foi realizada em três áreas de interesse, nas projeções anterior e posterior, de ambos os pulmões. As comparações foram feitas entre ambos os pulmões e entre as condições de crise e controle, considerando as áreas de interesse e os gradientes entre elas e entre as projeções anterior e posterior das mesmas. Para análise comparativa das médias foi utilizado o teste t de Student para amostras pareadas, considerando o nível de significância de 0,05. Resultados: Iniciaram o estudo transversal 38 pacientes e permaneceram no estudo longitudinal 19 pacientes; da amostra total, 22 eram do sexo masculino. A idade variou de 1 a 8 meses (média 2,8 meses). A distribuição do fluxo sangüíneo pulmonar regional foi maior na região superior do pulmão esquerdo (PE) em relação ao pulmão direito (PD), na crise (P < 0,001), e maior na região média do PD, no controle. Os gradientes de distribuição do fluxo sangüíneo pulmonar entre as regiões superior e média e superior e inferior foi maior no PE, na crise e no controle (P < 0,05). O gradiente de distribuição do fluxo sangüíneo pulmonar entre as regiões média e inferior foi maior no PD, na crise e no controle. O gradiente de distribuição do fluxo sangüíneo pulmonar no eixo ântero-posterior na região superior foi > 1,0 em ambos os pulmões, na crise, e apenas no PE, no controle; na região média, foi > 1,0 em ambos os pulmões, na crise e no controle; na região inferior, foi > 1,0 apenas no PD, na crise e no controle (P < 0,05). A distribuição do fluxo sangüíneo pulmonar, comparada entre crise e controle, não mostrou diferença em quaisquer das regiões ou dos gradientes avaliados. Não houve associação entre o padrão de distribuição do fluxo sangüíneo pulmonar regional na crise com a avaliação clínica ou com a avaliação radiológica dos pacientes. Conclusão: não se evidenciou uma distribuição do fluxo sangüíneo pulmonar com caraterística de expressar o padrão da relação ventilação-perfusão em lactentes jovens hospitalizados com bronquiolite viral aguda. Ocorreu apenas uma tendência de redirecionamento da distribuição do fluxo sangüíneo pulmonar para as regiões superiores.
Resumo:
A forte alta dos imóveis no Brasil nos últimos anos iniciou um debate sobre a possível existência de uma bolha especulativa. Dada a recente crise do crédito nos Estados Unidos, é factível questionar se a situação atual no Brasil pode ser comparada à crise americana. Considerando argumentos quantitativos e fundamentais, examina-se o contexto imobiliário brasileiro e questiona-se a sustentabilidade em um futuro próximo. Primeiramente, analisou-se a taxa de aluguel e o nível de acesso aos imóveis e também utilizou-se um modelo do custo real para ver se o mercado está em equilíbrio o não. Depois examinou-se alguns fatores fundamentais que afetam o preço dos imóveis – oferta e demanda, crédito e regulação, fatores culturais – para encontrar evidências que justificam o aumento dos preços dos imóveis. A partir dessas observações tentou-se chegar a uma conclusão sobre a evolução dos preços no mercado imobiliário brasileiro. Enquanto os dados sugerem que os preços dos imóveis estão supervalorizados em comparação ao preço dos aluguéis, há evidências de uma legítima demanda por novos imóveis na emergente classe média brasileira. Um risco maior pode estar no mercado de crédito, altamente alavancado em relação ao consumidor brasileiro. No entanto, não se encontrou evidências que sugerem mais do que uma temporária estabilização ou correção no preço dos imóveis.