710 resultados para Haikari, Janne


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The details of the mechanism of persistent luminescence were probed by investigating the trap level structure of Sr(2)MgSi(2)O(7):Eu(2+),R(3+) materials (R: Y, La-Lu, excluding Pm and Eu) with thermoluminescence (TL) measurements and Density Functional Theory (DFT) calculations. The TL results indicated that the shallowest traps for each Sr(2)MgSi(2)O(7):Eu(2+),R(3+) material above room temperature were always ca. 0.7 eV corresponding to a strong TL maximum at ca. 90 A degrees C. This main trap energy was only slightly modified by the different co-dopants, which, in contrast, had a significant effect on the depths of the deeper traps. The combined results of the trap level energies obtained from the experimental data and DFT calculations suggest that the main trap responsible for the persistent luminescence of the Sr(2)MgSi(2)O(7):Eu(2+),R(3+) materials is created by charge compensation lattice defects, identified tentatively as oxygen vacancies, induced by the R(3+) co-dopants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SolNET var den första europeiska forskarskolan för termisk solvenergi med 10 doktorander, där sju gemensamma doktorandkurser utvecklades och genomfördes under projektets gång. Projektet stöddes av EU-programmet Marie-Curie från juni 2006 till maj 2010.Centrum för solenergiforskning SERC vid Högskolan Dalarna deltog med en doktorand, Janne Paavilainen. SERC genomförde den första av doktorandkurserna, om dynamisk systemsimulering. 30 studenter deltog från 16 länder varav 22 var doktorander och tre var från industri.Under 2007 genomförde Paavilainen en teknoekonomisk utvärdering av mellanstora pellet- och solvärmesystem för närvärme som presenterades vid konferensen Eurosun 2008. Resultaten visar under vilka förutsättningar som solvärme kan vara ekonomisk lönsamt i närvärmesystem i Sverige och Finland. Paavilainen har varit medförfattare till en tidsskriftsartikel om SERCs simuleringsmodell för pelletspannor och –kaminer samt varit medförfattare till två tidsskriftsartiklar tillsammans med SPF (Schweiz) och TU Graz (Österrike) om en ny pannmodell för gas, olja och pellets. Dessa två validerade modeller i programmet TRNSYS används nu rutinmässigt i Sverige av SP och SERC och i Europa av ett flertal forskargrupper. Den nya pannmodellen som utvecklades med SPF och TU Graz har också införlivats i programmet Polysun som används av flera hundra användare runt hela världen, inkl. SERCs magisterstudenter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A literature survey and a theoretical study were performed to characterize residential chimney conditions for flue gas flow measurements. The focus is on Pitot-static probes to give sufficient basis for the development and calibration of a velocity pressure averaging probe suitable for the continuous dynamic (i.e. non steady state) measurement of the low flow velocities present in residential chimneys. The flow conditions do not meet the requirements set in ISO 10780 and ISO 3966 for Pitot-static probe measurements, and the methods and their uncertainties are not valid. The flow velocities in residential chimneys from a heating boiler under normal operating condi-tions are shown to be so low that they in some conditions result in voiding the assumptions of non-viscous fluid justifying the use of the quadratic Bernoulli equation. A non-linear Reynolds number dependent calibration coefficient that is correcting for the viscous effects is needed to avoid significant measurement errors. The wide range of flow velocity during normal boiler operation also results in the flow type changing from laminar, across the laminar to turbulent transition region, to fully turbulent flow, resulting in significant changes of the velocity profile during dynamic measurements. In addition, the short duct lengths (and changes of flow direction and duct shape) used in practice are shown to result in that the measurements are done in the hydrodynamic entrance region where the flow velocity profiles most likely are neither symmetrical nor fully developed. A measurement method insensitive to velocity profile changes is thus needed, if the flow velocity profile cannot otherwise be determined or predicted with reasonable accuracy for the whole measurement range. Because of particulate matter and condensing fluids in the flue gas it is beneficial if the probe can be constructed so that it can easily be taken out for cleaning, and equipped with a locking mechanism to always ensure the same alignment in the duct without affecting the calibration. The literature implies that there may be a significant time lag in the measurements of low flow rates due to viscous effects in the internal impact pressure passages of Pitot probes, and the significance in the discussed application should be studied experimentally. The measured differential pressures from Pitot-static probes in residential chimney flows are so low that the calibration and given uncertainties of commercially available pressure transducers are not adequate. The pressure transducers should be calibrated specifically for the application, preferably in combination with the probe, and the significance of all different error sources should be investigated carefully. Care should be taken also with the temperature measurement, e.g. with averaging of several sensors, as significant temperature gradients may be present in flue gas ducts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, gaseous emissions and particles are measured during start-up and stop periods for an over-fed boiler and an under-fed boiler. Both gaseous and particulate matter emissions are continuously measured in the laboratory. The measurement of gaseous emissions includes oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), nitrogen oxide and (NO). The emissions rates are calculated from measured emissions concentrations and flue gas flow. The behaviours of the boilers during start-up and stop periods are analysed and the emissions are characterised in terms of CO, NO, TOC and particles (PM2.5 mass and number). The duration of the characterised periods vary between two boilers due to the difference in type of ignition and combustion control. The under-fed boiler B produces higher emissions during start-up periods than the over-fed boiler A. More hydrocarbon and particles are emitted by the under-fed boiler during stop periods. Accumulated mass of CO and TOC during start-up and stop periods contribute a major portion of the total mass emitted during whole operation. However, accumulated mass of NO and PM during start-up and stop periods are not significant as the duration of emission peak is relatively short.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hereditary angioedema is characterized by recurrent attacks of angioedema of the skin, larynx, and gastrointestinal tract. Bradykinin is the key mediator of symptoms. Icatibant is a selective bradykinin B2 receptor antagonist.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In low-income settings, treatment failure is often identified using CD4 cell count monitoring. Consequently, patients remain on a failing regimen, resulting in a higher risk of transmission. We investigated the benefit of routine viral load monitoring for reducing HIV transmission.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To analyse mortality, loss to follow-up (LTFU) and retention on antiretroviral treatment (ART) in the first year of ART across all age groups in the Malawi national ART programme.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives  To assess the proportion of patients lost to programme (died, lost to follow-up, transferred out) between HIV diagnosis and start of antiretroviral therapy (ART) in sub-Saharan Africa, and determine factors associated with loss to programme. Methods  Systematic review and meta-analysis. We searched PubMed and EMBASE databases for studies in adults. Outcomes were the percentage of patients dying before starting ART, the percentage lost to follow-up, the percentage with a CD4 cell count, the distribution of first CD4 counts and the percentage of eligible patients starting ART. Data were combined using random-effects meta-analysis. Results  Twenty-nine studies from sub-Saharan Africa including 148 912 patients were analysed. Six studies covered the whole period from HIV diagnosis to ART start. Meta-analysis of these studies showed that of the 100 patients with a positive HIV test, 72 (95% CI 60-84) had a CD4 cell count measured, 40 (95% CI 26-55) were eligible for ART and 25 (95% CI 13-37) started ART. There was substantial heterogeneity between studies (P < 0.0001). Median CD4 cell count at presentation ranged from 154 to 274 cells/μl. Patients eligible for ART were less likely to become lost to programme (25%vs. 54%, P < 0.0001), but eligible patients were more likely to die (11%vs. 5%, P < 0.0001) than ineligible patients. Loss to programme was higher in men, in patients with low CD4 cell counts and low socio-economic status and in recent time periods. Conclusions  Monitoring and care in the pre-ART time period need improvement, with greater emphasis on patients not yet eligible for ART.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determine magnitude and reasons of loss to program and poor antiretroviral prophylaxis coverage in prevention of mother-to-child transmission (PMTCT) programs in sub-Saharan Africa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While having the highest vitamin C (VitC) concentrations in the body, specific functions of VitC in the brain have only recently been acknowledged. We have shown that postnatal VitC deficiency in guinea pigs causes impairment of hippocampal memory function and leads to 30% less neurons. This study investigates how prenatal VitC deficiency affects postnatal hippocampal development and if any such effect can be reversed by postnatal VitC repletion. Eighty pregnant Dunkin Hartley guinea pig dams were randomized into weight stratified groups receiving High (900 mg) or Low (100 mg) VitC per kg diet. Newborn pups (n = 157) were randomized into a total of four postnatal feeding regimens: High/High (Control); High/Low (Depleted), Low/Low (Deficient); and Low/High (Repleted). Proliferation and migration of newborn cells in the dentate gyrus was assessed by BrdU labeling and hippocampal volumes were determined by stereology. Prenatal VitC deficiency resulted in a significant reduction in postnatal hippocampal volume (P<0.001) which was not reversed by postnatal repletion. There was no difference in postnatal cellular proliferation and survival rates in the hippocampus between dietary groups, however, migration of newborn cells into the granular layer of the hippocampus dentate gyrus was significantly reduced in prenatally deficient animals (P<0.01). We conclude that a prenatal VitC deficiency in guinea pigs leads to persistent impairment of postnatal hippocampal development which is not alleviated by postnatal repletion. Our findings place attention on a yet unrecognized consequence of marginal VitC deficiency during pregnancy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Patients who are lost to follow-up (LTFU) while on antiretroviral therapy (ART) pose challenges to the long-term success of ART programs. We describe the extent to which patients considered LTFU are misclassified as true disengagement from care when they are still alive on ART and explain reasons for ART discontinuation using our active tracing program to further improve ART retention programs and policies. METHODS We identified adult ART patients who missed clinic appointment by more than 3 weeks between January 2006 and December 2010, assuming that such patients would miss their doses of antiretroviral drugs. Patients considered LTFU who consented during ART registration were traced by phone or home visits; true ART status after tracing was documented. Reasons for ART discontinuation were also recorded for those who stopped ART. RESULTS Of the 4,560 suspected LTFU cases, 1,384 (30%) could not be traced. Of the 3,176 successfully traced patients, 952 (30%) were dead and 2,224 (70%) were alive, of which 2,183 (99.5%) started ART according to phone-based self-reports or physical verification during in-person interviews. Of those who started ART, 957 (44%) stopped ART and 1,226 (56%) reported still taking ART at the time of interview by sourcing drugs from another clinic, using alternative ART sources or making brief ART interruptions. Among 940 cases with reasons for ART discontinuations, failure to remember (17%), too weak/sick (12%), travel (46%), and lack of transport to the clinic (16%) were frequently cited; reasons differed by gender. CONCLUSION The LTFU category comprises sizeable proportions of patients still taking ART that may potentially bias retention estimates and misdirect resources at the clinic and national levels if not properly accounted for. Clinics should consider further decentralization efforts, increasing drug allocations for frequent travels, and improving communication on patient transfers between clinics to increase retention and adherence.