815 resultados para Gemstone Team ELECTRODE
Resumo:
Background. In the field of information technology (IT) time pressure is common. Working with tight deadlines together on the same task increases the risk of social stressors referring to tensions and conflicts at work. Purpose. This field study tested both the association of time pressure and social stressors with blood pressure during work. Method. Seven employees – staff of a small IT enterprise – participated in repeated ambulatory blood pressure measurements over the course of one week. Time pressure and social stressors at work were assessed by questionnaire at the beginning of the study. Results. Multilevel regression analyses of 138 samples revealed higher levels of time pressure to be related to marginally significant increases in mean arterial blood pressure at noon and in the afternoon. In addition, higher levels of social stressors at work were significantly associated to elevated mean arterial pressure in the afternoon. Conclusion. Findings support the view that threats to the social self play an important role in occupational health.
Resumo:
We report a novel strategy for the regulation of charge transport through single molecule junctions via the combination of external stimuli of electrode potential, internal modulation of molecular structures, and optimization of anchoring groups. We have designed redox-active benzodifuran (BDF) compounds as functional electronic units to fabricate metal–molecule–metal (m–M–m) junction devices by scanning tunneling microscopy (STM) and mechanically controllable break junctions (MCBJ). The conductance of thiol-terminated BDF can be tuned by changing the electrode potentials showing clearly an off/on/off single molecule redox switching effect. To optimize the response, a BDF molecule tailored with carbodithioate (−CS2–) anchoring groups was synthesized. Our studies show that replacement of thiol by carbodithioate not only enhances the junction conductance but also substantially improves the switching effect by enhancing the on/off ratio from 2.5 to 8.
Resumo:
Upper echelon theory and research on innovation have considered top management teams and their behaviour and characteristics as important factors that positively influence innovativeness and organizational outcomes. Yet, innovation research has mostly focused on individual new product projects, and their performance and impact on firm performance. Recent research has started to apply a more holistic view in terms of innovation, by considering firm-wide innovation instead of single new products. Upper echelon research has concentrated on direct relationships between top management team characteristics and organizational outcomes. But recent research calls for mediating effects of the relationship between top management team characteristics and organizational outcomes. Hence, this study introduces firm innovativeness as a mediator between top management team innovation orientation and firm growth. Focusing on small and medium-sized firms, which often represent highly innovative firms, results show that firm innovativeness fully mediates the relationship between top management team innovation orientation and firm growth. Implications and future research are discussed.
Resumo:
HYPOTHESIS To evaluate the feasibility and the results of insertion of two types of electrode arrays in a robotically assisted surgical approach. BACKGROUND Recent publications demonstrated that robot-assisted surgery allows the implantation of free-fitting electrode arrays through a cochleostomy drilled via a narrow bony tunnel (DCA). We investigated if electrode arrays from different manufacturers could be used with this approach. METHODS Cone-beam CT imaging was performed on fivecadaveric heads after placement of fiducial screws. Relevant anatomical structures were segmented and the DCA trajectory, including the position of the cochleostomy, was defined to target the center of the scala tympani while reducing the risk of lesions to the facial nerve. Med-El Flex 28 and Cochlear CI422 electrodes were implanted on both sides, and their position was verified by cone-beam CT. Finally, temporal bones were dissected to assess the occurrence of damage to anatomical structures during DCA drilling. RESULTS The cochleostomy site was directed in the scala tympani in 9 of 10 cases. The insertion of electrode arrays was successful in 19 of 20 attempts. No facial nerve damage was observed. The average difference between the planned and the postoperative trajectory was 0.17 ± 0.19 mm at the level of the facial nerve. The average depth of insertion was 305.5 ± 55.2 and 243 ± 32.1 degrees with Med-El and Cochlear arrays, respectively. CONCLUSIONS Robot-assisted surgery is a reliable tool to allow cochlear implantation through a cochleostomy. Technical solutions must be developed to improve the electrode array insertion using this approach.
Lamb Temporal Bone as a Surgical Training Model of Round Window Cochlear Implant Electrode Insertion
Resumo:
OBJECTIVE The preservation of residual hearing in cochlear implantation opens the door for optimal functional results. This atraumatic surgical technique requires training; however, the traditional human cadaveric temporal bones have become less available or unattainable in some institutions. This study investigates the suitability of an alternative model, using cadaveric lamb temporal bone, for surgical training of atraumatic round window electrode insertion. INTERVENTION A total of 14 lamb temporal bones were dissected for cochlear implantation by four surgeons. After mastoidectomy, visualization, and drilling of the round window niche, an atraumatic round window insertion of a Medel Flex24 electrode was performed. Electrode insertion depth and position were verified by computed tomography scans. MAIN OUTCOME MEASURE All cochleas were successfully implanted using the atraumatic round window approach; however, surgical access through the mastoid was substantially different when compared human anatomy. The mean number of intracochlear electrode contacts was 6.5 (range, 4-11) and the mean insertion depth 10.4 mm (range, 4-20 mm), which corresponds to a mean angular perimodiolar insertion depth of 229 degrees (range 67-540°). Full insertion of the electrode was not possible because of the smaller size of the lamb cochlea in comparison to that of the human. CONCLUSION The lamb temporal bone model is well suited as a training model for atraumatic cochlear implantation at the level of the round window. The minimally pneumatized mastoid as well as the smaller cochlea can help prepare a surgeon for difficult cochlear implantations. Because of substantial differences to human anatomy, it is not an adequate training model for other surgical techniques such as mastoidectomy and posterior tympanotomy as well as full electrode insertion.
Resumo:
Operating room (OR) team safety training and learning in the field of dialysis access is well suited for the use of simulators, simulated case learning and root cause analysis of adverse outcomes. The objectives of OR team training are to improve communication and leadership skills, to use checklists and to prevent errors. Other objectives are to promote a change in the attitudes towards vascular access from learning through mistakes in a nonpunitive environment, to positively impact the employee performance and to increase staff retention by making the workplace safer, more efficient and user friendly.
Resumo:
The use of rotating ring–disk electrodes as generator-collector systems has so far been limited to the detection of Faradaic currents at the ring. As opposed to other generator-collector configurations, non-Faradaic detection has not yet been carried out with rotating ring–disk electrodes. In this study, a.c. perturbation based detection for measurement of the ring impedance is introduced. By using a conducting polymer-modified disk electrode in combination with a bare gold ring as a model, it is shown that the measured ring capacitance correlates with the polarization of the polymer film, most probably due to counter-ion exchange. A method of calculating the ring capacitance based on a small-signal sinusoid perturbation is described and the most important instrumental limitations are identified.
Resumo:
Ceramics are known to be chemically stable, and the possibility to electrically dope polymer-derived ceramics makes it a material of interest for implantable electrode applications. We investigated cytotoxic characteristics of four polymer-derived ceramic candidates with either electrically conductive or insulating properties. Cytotoxicity was assessed by culturing C2C12 myoblast cells under two conditions: by exposing them to material extracts and by putting them directly in contact with material samples. Cell spreading was optically evaluated by comparing microscope observations immediately after the materials insertion and after 24 h culturing. Cell viability (MTT) and mortality (LDH) were quantified after 24-h incubation in contact with the materials. Comparison was made with biocompatible positive references (alumina, platinum, biocompatible stainless steel 1.4435), negative references (latex, stainless steel 1.4301) and controls (no material present in the culture wells). We found that the cytotoxic properties of tested ceramics are comparable to established reference materials. These ceramics, which are reported to be very stable, can be microstructured and electrically doped to a wide range of conductivity and are thus excellent candidates for implantable electrode applications including pacemakers.
Resumo:
OBJECTIVE Cochlear implants (CIs) have become the gold standard treatment for deafness. These neuroprosthetic devices feature a linear electrode array, surgically inserted into the cochlea, and function by directly stimulating the auditory neurons located within the spiral ganglion, bypassing lost or not-functioning hair cells. Despite their success, some limitations still remain, including poor frequency resolution and high-energy consumption. In both cases, the anatomical gap between the electrode array and the spiral ganglion neurons (SGNs) is believed to be an important limiting factor. The final goal of the study is to characterize response profiles of SGNs growing in intimate contact with an electrode array, in view of designing novel CI devices and stimulation protocols, featuring a gapless interface with auditory neurons. APPROACH We have characterized SGN responses to extracellular stimulation using multi-electrode arrays (MEAs). This setup allows, in our view, to optimize in vitro many of the limiting interface aspects between CIs and SGNs. MAIN RESULTS Early postnatal mouse SGN explants were analyzed after 6-18 days in culture. Different stimulation protocols were compared with the aim to lower the stimulation threshold and the energy needed to elicit a response. In the best case, a four-fold reduction of the energy was obtained by lengthening the biphasic stimulus from 40 μs to 160 μs. Similarly, quasi monophasic pulses were more effective than biphasic pulses and the insertion of an interphase gap moderately improved efficiency. Finally, the stimulation with an external electrode mounted on a micromanipulator showed that the energy needed to elicit a response could be reduced by a factor of five with decreasing its distance from 40 μm to 0 μm from the auditory neurons. SIGNIFICANCE This study is the first to show electrical activity of SGNs on MEAs. Our findings may help to improve stimulation by and to reduce energy consumption of CIs and thereby contribute to the development of fully implantable devices with better auditory resolution in the future.
Resumo:
BACKGROUND Surgical-site infections (SSIs) are the most common complications after surgery. An influence from talking and distractions during surgery on patient outcomes has been suggested, but there is limited evidence. The aim of this prospective observational study was to assess the relationship between intraoperative communication within the surgical team and SSI, and between intraoperative distractions and SSI. METHODS This prospective observational study included patients undergoing elective, open abdominal procedures. For each procedure, intraoperative case-relevant and case-irrelevant communication, and intraoperative distractions were observed continuously on site. The influence of communication and distractions on SSI after surgery was assessed using logistic regressions, adjusting for risk factors. RESULTS A total of 167 observed procedures were analysed; their mean(s.d.) duration was 4·6(2·1) h. A total of 24 SSIs (14·4 per cent) were diagnosed. Case-relevant communication during the procedure was independently associated with a reduced incidence of organ/space SSI (propensity score-adjusted odds ratio 0·86, 95 per cent c.i. 0·77 to 0·97; P = 0·014). Case-irrelevant communication during the closing phase of the procedure was independently associated with increased incidence of incisional SSI (propensity score-adjusted odds ratio 1·29, 1·08 to 1·55; P = 0·006). Distractions had no association with SSI. CONCLUSION More case-relevant communication was associated with fewer organ/space SSIs, and more case-irrelevant communication during wound closure was associated with incisional SSI.