992 resultados para Fluorescent antibody technique
Resumo:
Antibodies to a number of parasite antigens are found in schistosomiasis patients, and antibodies to early developmental stages were demonstrated to be efficient immunologic markers for the diagnosis of schistosomiasis. In the present study, decay patterns of IgM and IgG antibodies against cercariae and schistosomula were investigated, in comparison to antibodies against worms and eggs in schistosomiasis patients after chemotherapy, for an investigation of seroepidemiologic aspects. Data obtained in the study of 359 serum samples from patients with Schistosoma mansoni infection, noninfected individuals, and patients followed-up for a period of 12 to 15 months after treatment provided the basis to postulate a general pattern for the kinetics of antibody decay. Before treatment, the antibody pattern was represented by a unimodal curve, which shifted to a bimodal curve after treatment, and ended with a unimodal curve similar to that for the noninfected group. Different types of antibodies were classified into four categories according to their decay features, and anti-schistosomulum IgM was classified into the moderate-decay caterogy, whereas other antibodies to early parasite stages were classified into the slow-decay category. The present methodology permits the identification of the most suitable antibodies to be detected in field control programs for schistosomiasis or other parasitoses
Resumo:
We describe a case of human T-lymphotropic virus type I associated myelopathy in a 50-year old woman in Nigeria. The patient presented with progressive loss of tone to the two lower limbs and later inability to walk. The HTLV-I antibody presence in the plasma collected from the patient was repeatedly detected by enzyme immunoassays (Abbott HTLV-I EIA and Coulter SELECT-HTLV I/II) and confirmed by Western blot technique. In addition, HTLV-I DNA was amplified from the genomic DNA isolated from the peripheral blood mononuclear cells of the patient by the polymerase chain reaction technique. This finding is significant being the first report of association of HTLV-I with myelopathy in Nigeria.
Resumo:
The recognition profile of the tissue cysts antigens by IgG antibodies was studied during acute and chronic human toxoplasmic infection. Thus the IgG response against Toxoplasma gondii was investigated by immunoblotting in two patients accidentally infected with the RH strain as well as in group of naturally infected patients at acute and chronic phase. There was an overall coincidence of molecular mass among antigens of tachyzoites and tissue cysts recognized by these sera, however, they appear not to be the same molecules. The response against tissue cysts starts early during acute infection, and the reactivity of antibodies is strong against a wide range of antigens. Six bands (between 82 and 151 kDa) were exclusively recognized by chronic phase sera but only the 132 kDa band was positive in more than 50% of the sera analysed. A mixture of these antigens could be used to discriminate between the two infection phases. The most important antigens recognized by the acute and the chronic phase sera were 4 clusters in the ranges 20-24 kDa, 34-39 kDa, 58-80 kDa and 105-130 kDa as well as two additional antigens of 18 and 29 kDa. Both accidentally infected patients and some of the naturally infected patients showed a weak specific response against tissue cyst antigens.
Resumo:
The relationship between the IgM antibody response, antigenic load as well as the clinical improvement after chemotherapy was studied in order to obtain useful data for the early diagnosis and monitoring leprosy. A level of 82% (94/115) agreement was obtained between IgM UMELISA HANSEN and slitskin smear examination. Discrepant results were observed in 16 patients who showed positive IgM response despite negative by the skin smear examination. In these patients, the IgM response was seen to be associated to the early signal for bacilli recurrence in the skin. In one of these patients the presence of bacilli was demonstrated in the skin, two months after IgM antibodies being detected by UMELISA HANSEN. Also in one of the treated patients positive by both diagnostic techniques, a remarkable decrease in the IgM antibody levels was seen, correlating with a significant clinical improvement. Moreover it was found a direct relationship between the IgM antibody response and bacterial antigenic load, regardless the time elapsed in the disease's evolution.
Resumo:
We report an adaptation of a technique for the blood sample collection (GFM) as well as for the extraction and amplification of Plasmodium DNA for the diagnosis of malaria infection by the PCR/ELISA. The method of blood sample collection requires less expertise and saves both time and money, thus reducing the cost by more than half. The material is also suitable for genetic analysis in either fresh or stored specimens prepared by this method.
Resumo:
Toxocariasis is caused by infection of man by Toxocara canis and Toxocara cati larvae, the common roundworm of dogs and cats. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. Non specific reactions are observed mainly due to cross-reactivity with Ascaris sp antigens. This investigation aimed at developing and evaluating an indirect antibody competition ELISA (IACE) employing a specific rabbit IgG anti-Toxocara canis excretory-secretory antigens as the competition antibody, in order to improve indirect ELISA specificity performed for toxocariasis diagnosis. For that, the rabbit IgG was previously absorbed by Ascaris suum adult antigens. Sensitivity and specificity of IACE were first evaluated in 28 serum samples of mice experimentally infected with T. canis embryonated eggs. Adopting cut-off value established in this population before infection, sensitivity and specificity were 100% after 20 days post-inoculation. For human population IACE was evaluated using sera from 440 patients with clinical signs of toxocariasis and the cut-off value was established with 60 serum samples from apparently healthy individuals. Using as reference test the indirect ELISA performed by Adolfo Lutz Institute, sensitivity was 60.2%, specificity was 98% and concordance was 77.3%. Repeatability of IACE was evaluated by the inter-reactions variation coefficient (2.4%).
Resumo:
Active infection by T. gondii was evaluated by immunoassay for soluble SAG-1 (p30), the major surface antigen from T. gondii, specific antibodies and immune complexes in human cerebrospinal fluid (CSF) samples. A total of 263 samples of CSF were collected from hospitalized patients presenting neurological disorders and analyzed for antibodies to HIV. Patients were divided into two groups: HIV positive (n = 96) or HIV negative (n =167). The results of the assays showed that 45% of all samples were positive for soluble SAG-1. Toxoplasma Ag/Ab immune complexes were detected in 19% of the CSF samples and 62% were positive for T. gondii- specific IgG. A combination of these assays in the presence of clinical findings consistent with active Toxoplasma infection may predict the presence of toxoplasmic encephalitis. Moreover, detection of soluble SAG-1 in the CSF of these individuals appears consistent with active infection.
Resumo:
Despite the absence of current official reports showing the number of cattle infected by rabies, it is estimated that nearly 30,000 bovines are lost each year in Brazil. In order to minimize the important economic losses, control of the disease is achieved by eliminating bat colonies and by herd vaccination. In this study, we compare the antibody response in cattle elicited by vaccination with an attenuated ERA vaccine (AEvac) and an inactivated-adjuvanted PV (IPVvac) vaccine. The antibody titers were appraised by cell-culture neutralization test and ELISA, and the percentage of seropositivity was ascertained for a period of 180 days. IPVvac elicited complete seropositivity rates from day 30 to day 150, and even on day 180, 87% of the sera showed virus-neutralizing antibody titers (VNA) higher than 0.5IU/ml. There were no significant differences between the VNA titers and seropositivity rates obtained with IPVvac in the two methods tested. AEvac, however, elicited significantly lower titers than those observed in the group receiving inactivated vaccine. In addition, the profiles of antirabies IgG antibodies, evaluated by ELISA, and VNA, appraised by cell-culture neutralization test, were slightly different, when both vaccines were compared.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro
Resumo:
The clinical significance of isolated anti-HBc is still a challenge. To elucidate the real importance of this finding in our blood donors, an investigation algorithm was tested. One hundred and twelve isolated anti-HBc seropositive blood donors underwent clinical evaluation and retesting of HBV markers. Those who presented repeatedly reactive isolated anti-HBc, received a single dose of hepatitis B recombinant vaccine to verify anti-HBs early response. A HBV-DNA determination by PCR was done for those who did not test positive to anti-HBs after vaccine. The level of anti-HBc was recorded as a ratio of the sample-to-cut-off values (S:C ratio) in 57 candidates at donation. Comparing true and false-positive anti-HBc results, the different S:C ratios of them were statistically significant and when less than 2, implying in a false-positive result probability over 80%. A high percent of false-positive results (16.07%) was verified after anti-HBc retesting. HBV immunity was characterized in 49.11%, either by anti-HBs detection in retesting (15.18%), or after a single dose HBV vaccination (33.93%). HBV-DNA was negative in all tested donors. In conclusion, this algorithm was useful to clarify the meaning of isolated anti-HBc in most of our blood donors.
Resumo:
A prospective study was designed to evaluate disorders of hemostasis and levels of anticardiolipin antibodies (ACL) in 30 patients with severe leptospirosis and acute renal failure (ARF) (ARF was defined as serum creatinine > or = 1.5 mg/dL). The patients had been admitted to the Walter Cantídio University Hospital, São José Infectious Diseases Hospital and General Hospital of Fortaleza, Ceará, from August 1999 to July 2001. They all were male, with a mean age of 32 ± 14 years and with clinical and laboratory diagnoses of ARF leptospirosis. The time elapsed between onset of symptoms and the first hemorrhagic manifestation was 9 ± 4 days. Bleeding was observed in 86% of the patients. Laboratory tests showed significantly high levels of urea (181 ±95 mg/dl), fibrinogen, (515 ± 220 mg/dl), prothrombin time (13.3 ± 0.9 seconds) and low platelet counts (69 ± 65x10³/mm³) on admission. There was no elevation in activated partial thromboplastin time or thrombin time. Levels of IgM and IgG ACL concentrations were significantly increased (p < 0.05) in leptospirosis patients when compared to control patients (28.5 ± 32.4 vs. 11.5 ± 7.9MPL U/ml and 36.7 ± 36.1 vs. 6.5 ± 2.5 GPL U/ml), respectively. Vasculitis, thrombocytopenia and uremia should be considered important factors for the pathogenesis of hemorrhagic disturbances and the main cause of death in severe leptospirosis.
Resumo:
The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Conservação e Restauro, especialização em pintura sobre tela
Resumo:
Thesis for the Master degree in Structural and Functional Biochemistry