990 resultados para Fiber Bragg Grating (FBG) sensors
Resumo:
Long period grating was UV inscribed into a multicore fiber consisting of 120 single mode cores. The multicore fiber that hosts the grating was fusion spliced into a single mode fiber at both ends. The splice creates a taper transition between the two types of fiber that produces a nonadiabatic mode evolution; this results in the illumination of all the modes in the multicore fiber. The spectral characteristics of this fiber device as a function of curvature were investigated. The device yielded a significant spectral sensitivity as high as 1.23 nm/m-1 and 3.57 dB/m-1 to the ultra-low curvature values from 0 to 1 m-1. This fiber device can also distinguish the orientation of curvature experienced by the fiber as the long period grating attenuation bands producing either a blue or red wavelength shift. The finite element method (FEM) model was used to investigate the modal behavior in multicore fiber and to predict the phase-matching curves of the long period grating inscribed into multicore fiber. © 2014 Optical Society of America.
Resumo:
We experimentally demonstrate an all-fiber single-polarization dual-wavelength Yb-doped fiber laser passively mode-locked with a 45°-tilted fiber grating for the first time. Stable dual-wavelength operation exhibits double-rectangular spectral profile centered at 1033 and 1053 nm, respectively. The 3 dB bandwidth of each rectangular optical spectrum is estimated as 10 nm. The separation of two fundamental repetition rates is 6 kHz. By employing the 45° TFG with the polarization-dependent loss of 33 dB, output pulses with 27 dB polarization extinction ratio are implemented in the experiment. The single pulse centered at 1053 nm is researched by using a filter at the output port of the laser, and the experimental results denote that the output ps pulses are highly chirped. The formation mechanism of dual-wavelength operation is investigated.
Resumo:
The impact of third-order dispersion (TOD) on optical rogue wave phenomenon is investigated numerically. We validate the TOD coefficient by utilizing the eigenvalue of the associated equation of the nonlinear Schrödinger equation (NLSE). © 2014 OSA.
Resumo:
A hybrid structure comprising of a 45° and an 81° TFG based RI sensor has been demonstrated. The experiment results show a higher RI sensitivity, being around 180nm/RIU at RI=1.345 and 926nm/RIU at RI=1.412 region. © 2014 OSA.
Resumo:
Polymer FBGs have advantages for sensing because of low Young's modulus, high temperature sensitivity, large strain range and so on. They are attractive for many niche applications such as structural health monitoring of composite materials, biochemical and biomedical sensing. While polymer FBGs have been developed for some time, polymer microfibre Bragg gratings are developed only recently and have shown to introduce some interesting features, e.g. increased pressure sensitivity to pressure / force and improved response time to humidity. We will report and discuss the recent work on polymer FBG and polymer microfibre Bragg gratings as well as their applications such as accelerometer, humidity sensor and force and pressure sensor. © 2015 OSA.
Resumo:
The formation and evolution of bound dissipative pulses in the all-normal dispersion Yb-fiber laser based on a novel 45° tilted fiber grating (TFG) are first investigated both numerically and experimentally. Based on the nonlinear polarization rotation technique, the TFG and two polarization controllers (PCs) are exploited for stable self-started passive mode locking. Numerical results show that the formation of bound-state pulses in the all-normal dispersion region is the progress of soliton shaping through the dispersive waves and follows the soliton energy quantization effect. Theoretical and experimental results demonstrate that the formation mechanism of bound-state pulses can be attributed to the high pump strength and effective filter bandwidth. The obtained bound-state dissipative pulses with quasi-rectangular spectral profile have fixed pulse separation as a function of pump power. © 2013 Astro Ltd.
Resumo:
Fiber optic sensors are fabricated for detecting static magnetic fields. The sensors consist of a UV inscribed long period grating with two 50 micron long microslots. The microslots are fabricated using the femtosecond laser based inscribe and etch technique. The microslots and the fiber surface are coated with a magnetostrictive material Terfenol-D. A spectral sensitivity of 1.15 pm/mT was measured in transmission with a working resolution of ±0.2 mT for a static magnetic field strength below 10 mT. These devices also present a different response when the spatial orientation of the fiber was adjusted relative to the magnetic field lines.
Resumo:
Photonic crystal fibres (PCF) and more commonly microstructure fibres, remain interesting and novel fibre types and when suitably designed can prove to be "ideal" for sensing applications, as the different geometrical arrangement of the air holes alters their optical wave-guiding properties, whilst also providing tailored dispersion characteristics. This impacts the performance of grating structures, which offer wavelength encoded sensing information. We undertake a study on different air hole geometries and proceed with characterization of fibre Bragg and long period gratings, FBG and LPG, respectively that have been inscribed (using either a femtosecond or ultraviolet laser system) within different designs of microstructured fibre that are of interest for sensing applications. © 2012 SPIE.
Resumo:
The stress sensitivity of polymer optical fibre (POF) based Fabry-Perot sensors formed by two uniform Bragg gratings with finite dimensions is investigated. POF has received high interest in recent years due to its different material properties compared to its silica counterpart. Biocompatibility, a higher failure strain and the highly elastic nature of POF are some of the main advantages. The much lower Young’s modulus of polymer materials compared to silica offers enhanced stress sensitivity to POF based sensors which renders them great candidates for acoustic wave receivers and any kind of force detection. The main drawback in POF technology is perhaps the high fibre loss. In a lossless fibre the sensitivity of an interferometer is proportional to its cavity length. However, the presence of the attenuation along the optical path can significantly reduce the finesse of the Fabry-Perot interferometer and it can negatively affect its sensitivity at some point. The reflectivity of the two gratings used to form the interferometer can be also reduced as the fibre loss increases. In this work, a numerical model is developed to study the performance of POF based Fabry-Perot sensors formed by two uniform Bragg gratings with finite dimensions. Various optical and physical properties are considered such as grating physical length, grating effective length which indicates the point where the light is effectively reflected, refractive index modulation of the grating, cavity length of the interferometer, attenuation and operating wavelength. Using this model, we are able to identify the regimes in which the PMMA based sensor offer enhanced stress sensitivity compared to silica based one.
Resumo:
We report on the generation of orthogonally polarized bright–dark pulse pair in a passively mode-locked fiber laser with a large-angle tilted fiber grating (LA-TFG). The unique polarization properties of the LA-TFG, i.e., polarization-dependent loss and polarization-mode splitting, enable dual-wavelength mode-locking operation. Besides dual-wavelength bright pulses with uniform polarization at two different wavelengths, the bright–dark pulse pair has also been achieved. It is found that the bright–dark pulse pair is formed due to the nonlinear couplings between lights with two orthogonal polarizations and two different wavelengths. Furthermore, harmonic mode-locking of bright–dark pulse pair has been observed. The obtained bright–dark pulse pair could find potential use in secure communication system. It also paves the way to manipulate the generation of dark pulse in terms of wavelength and polarization, using specially designed fiber grating for mode-locking.
Resumo:
A novel highly efficient, fiber-compatible spectrally encoded imaging (SEI) system using a 45° tilted fiber grating (TFG) is proposed and experimentally demonstrated for the first time, to the best of our knowledge. The TFG serves as an in-fiber lateral diffraction element, eliminating the need for bulky and lossy free-space diffraction gratings in conventional SEI systems. Under proper polarization control, due to the strong tilted reflection, the 45° TFG offers a diffraction efficiency as high as 93.5%. Our new design significantly reduces the volume of the SEI system and improves energy efficiency and system stability. As a proof-ofprinciple experiment, spectrally encoded imaging of a customer-designed sample (9.6 mm x 3.0 mm) using the TFG-based system is demonstrated. The lateral resolution of the SEI system is measured to be 42 μm in our experiment.
Resumo:
Using excessively tilted fiber grating (Ex-TFG) inscribed in standard single mode fiber, we developed a novel label-free immunoassay for specific detection of porcine circovirus type 2 (PCV2), which is a minim animal virus. Staphylococcal protein A (SPA) was used to modify the silanized fiber surface thus forming a SPA layer, which would greatly enhance the proportion of anti-PCV2 monoclonal antibody (MAb) bioactivity, thus improving the effectiveness of specific adsorption and binding events between anti-PCV2 MAbs and PCV2 antigens. Immunoassay experiments were carried out by monitoring the resonance wavelength shift of the proposed sensor under different PCV2 titer levels. Anti-PCV2 MAbs were thoroughly dissociated from the SPA layer by treatment with urea, and recombined to the SPA layer on the sensor surface for repeated immunoassay of PCV2. The specificity of the immunosensor was inspected by detecting porcine reproductive and respiratory syndrome virus (PRRSV) first, and PCV2 subsequently. The results showed a limit of detection (LOD) for the PCV2 immunosensor of ~9.371TCID50/mL, for a saturation value of ~4.801×103TCID50/mL, with good repeatability and excellent specificity.
Resumo:
There have been over 3000 bridge weigh-in-motion (B-WIM) installations in 25 countries worldwide, this has led vast improvements in post processing of B-WIM systems since its introduction in the 1970’s. This paper introduces a new low-power B-WIM system using fibre optic sensors (FOS). The system consisted of a series of FOS which were attached to the soffit of an existing integral bridge with a single span of 19m. The site selection criteria and full installation process has been detailed in the paper. A method of calibration was adopted using live traffic at the bridge site and based on this calibration the accuracy of the system was determined.
Resumo:
Due to the limitation of the lens effect of the optical fibre and the inhomogeneity of the laser fluence on different cores, it is still challenging to controllably inscribe different fibre Bragg gratings (FBGs) in multicore fibres. In this article, we reported the FBG inscription in four core fibres (FCFs), whose cores are arranged in the corners of a square lattice. By investigating the influence of different inscription conditions during inscription, different results, such as simultaneous inscription of all cores, selectively inscription of individual or two cores, and even double scanning in perpendicular core couples by diagonal, are achieved. The phase mask scanning method, consisting of a 244nm Argon-ion frequencydoubled laser, air-bearing linear transfer stage and cylindrical lens and mirror setup, is used to precisely control the grating inscription in FCFs. The influence of three factors is systematically investigated to overcome the limitations, and they are the defocusing length between the cylindrical lens and the bare fibre, the rotation geometry of the fibre to the irritation beam, and the relative position of the fibre in the vertical direction of the laser beam.