993 resultados para Fetal Monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current situation of regional, rather' than national, problems of eutrophication in standing waters has been widely aired in recent reports. A reliable, quantitative data base is a prerequisite to future trend monitoring, a concensus view of those reports. The objective of this report is to establish requirements, methodology and a minimal data set for nutrient and algae status in water supply reservoirs in England which may be used as a protocol for future trend monitoring.A pilot study has been carried out to assess the relative merits of different sampling strategies, the choice of which has major implications for the cost of sample collection. This short report suggests that consider the possibility of designating a few sites as ”baseline sites” at which detailed changes in trophic status as monitored by the more labour-intensive parameters would be collected on a regular, long term basis to help in the interpretation of the low cost survey results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A síndrome da imunodeficiência adquirida (AIDS), causada pelo vírus da imunodeficiência humana (HIV), é uma das epidemias mais impactantes do milênio e, desde o início, o número de mulheres jovens infectadas vem aumentando vertiginosamente, principalmente nos países em desenvolvimento onde muitas destas engravidam precocemente. Apesar da grande maioria dos casos de AIDS pediátrico no mundo resultar da transmissão vertical, aproximadamente dois terços dos neonatos expostos ao HIV durante a vida fetal não são contaminados. Neste sentido, seguindo as recomendações do consenso brasileiro (Ministério da Saúde), toda criança cuja transmissão vertical tenha sido descartada laboratorialmente não necessita de acompanhamento ambulatorial particularizado. Entretanto, resultados anteriores obtidos pelo nosso grupo demonstraram que, gestantes infectadas pelo HIV-1 que não controlam a carga viral plasmática (CVP), apresentam níveis elevados de citocinas inflamatórias e, no presente estudo, resultados revelam que neonatos não-infectados nascidos dessas gestantes apresentam anormalidades imunofuncionais no compartimento das células T do cordão umbilical quando expostos in vitro a ativadores policlonais, mas não aos antígenos do HIV-1. Ademais, quando comparada a neonatos não expostos, a ativação in vitro das células T de neonatos expostos ao HIV-1 com anti-CD3/anti-CD28 induziu a produção de níveis elevados de IL-17 e reduzidos de IL-10. Interessantemente, essa tendência das células T em secretar IL-17 parece estar relacionada à liberação de níveis elevados de IL-23 pelas células dendríticas derivadas de monócitos do sangue do cordão umbilical estimuladas com lipopolissacarídeo bacteriano. Uma ausência de sensibilização uterina aos antígenos do HIV-1 sugere que essas alterações possam traduzir um efeito adverso da produção elevada de citocinas inflamatórias maternas sobre o sistema imune do neonato, o que pode desequilibrar os eventos envolvidos na maturação e homeostasia imune fetal e neonatal, favorecendo o predomínio de fenótipos Th anômalos, tal como Th17. Essa hiper-responsividade das células Th17 pode vir a comprometer não apenas a capacidade da criança em responder de forma adequada a diferentes estímulos antigênicos ao longo de sua vida, como também pode torná-la mais suscetível a desordens imunomediadas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Non-alcoholic fatty liver disease (NAFLD) is caused by abnormal accumulation of lipids within liver cells. Its prevalence is increasing in developed countries in association with obesity, and it represents a risk factor for non-alcoholic steatohepatitis (NASH), cirrhosis and hepatocellular carcinoma. Since NAFLD is usually asymptomatic at diagnosis, new non-invasive approaches are needed to determine the hepatic lipid content in terms of diagnosis, treatment and control of disease progression. Here, we investigated the potential of magnetic resonance imaging (MRI) to quantitate and monitor the hepatic triglyceride concentration in humans. Methods: A prospective study of diagnostic accuracy was conducted among 129 consecutive adult patients (97 obesity and 32 non-obese) to compare multi-echo MRI fat fraction, grade of steatosis estimated by histopathology, and biochemical measurement of hepatic triglyceride concentration (that is, Folch value). Results: MRI fat fraction positively correlates with the grade of steatosis estimated on a 0 to 3 scale by histopathology. However, this correlation value was stronger when MRI fat fraction was linked to the Folch value, resulting in a novel equation to predict the hepatic triglyceride concentration (mg of triglycerides/g of liver tissue = 5.082 + (432.104 * multi-echo MRI fat fraction)). Validation of this formula in 31 additional patients (24 obese and 7 controls) resulted in robust correlation between the measured and estimated Folch values. Multivariate analysis showed that none of the variables investigated improves the Folch prediction capacity of the equation. Obese patients show increased steatosis compared to controls using MRI fat fraction and Folch value. Bariatric surgery improved MRI fat fraction values and the Folch value estimated in obese patients one year after surgery. Conclusions: Multi-echo MRI is an accurate approach to determine the hepatic lipid concentration by using our novel equation, representing an economic non-invasive method to diagnose and monitor steatosis in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of high speed laser beam parameters during processing is a topic that has seen growing attention over the last few years as quality assurance places greater demand on the monitoring of the manufacturing process. The targets for any monitoring system is to be non-intrusive, low cost, simple to operate, high speed and capable of operation in process. A new ISO compliant system is presented based on the integration of an imaging plate and camera located behind a proprietary mirror sampling device. The general layout of the device is presented along with the thermal and optical performance of the sampling optic. Diagnostic performance of the system is compared with industry standard devices, demonstrating the high quality high speed data which has been generated using this system.