947 resultados para Electronics and Electrical


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction. From freedom to bondage, by H. Spencer.--The impracticability of socialism, by E. S. Robertson.--The limits of liberty, by W. Donisthorpe.--Liberty for labour, by G. Howell.--State socialism in the Antipodes, by C. Fairfield.--The discontent of the working-classes, by E. Vincent.--Investment, by T. Mackay.--Free education, by B. H. Alford.--The housing of the working-classes and of the poor, by A. Raffalovich.--The evils of state trading as illustrated by the Post Office, by F. Millar.--Free libraries, by M. D. O'Brien.--The State and electrical distribution, by F. W. Beauchamp Gordon.--True line of deliverance, by A. Herbert.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

FLUIDEX

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Previously pub., in part, as chapters 1 to 8, and 12 of Kloeffler's Industrial electronics and control.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In most magnetic resonance imaging (MRI) systems, pulsed magnetic gradient fields induce eddy currents in the conducting structures of the superconducting magnet. The eddy currents induced in structures within the cryostat are particularly problematic as they are characterized by long time constants by virtue of the low resistivity of the conductors. This paper presents a three-dimensional (3-D) finite-difference time-domain (FDTD) scheme in cylindrical coordinates for eddy-current calculation in conductors. This model is intended to be part of a complete FDTD model of an MRI system including all RF and low-frequency field generating units and electrical models of the patient. The singularity apparent in the governing equations is removed by using a series expansion method and the conductor-air boundary condition is handled using a variant of the surface impedance concept. The numerical difficulty due to the asymmetry of Maxwell equations for low-frequency eddy-current problems is circumvented by taking advantage of the known penetration behavior of the eddy-current fields. A perfectly matched layer absorbing boundary condition in 3-D cylindrical coordinates is also incorporated. The numerical method has been verified against analytical solutions for simple cases. Finally, the algorithm is illustrated by modeling a pulsed field gradient coil system within an MRI magnet system. The results demonstrate that the proposed FDTD scheme can be used to calculate large-scale eddy-current problems in materials with high conductivity at low frequencies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A set of varying-thickness Au-films were thermally evaporated onto poly(styrene-co-acrylonitrile) thin film surfaces. The Au/PSA bi-layer targets were then implanted with 50 keV N+ ions to a fluence of 1 × 1016 ions/cm2 to promote metal-to-polymer adhesion and to enhance their mechanical and electrical performance. Electrical conductivity measurements of the implanted Au/PSA thin films showed a sharp percolation behavior versus the pre-implant Au-film thickness with a percolation threshold near the nominal thickness of 44 Å. The electrical conductivity results are discussed along with the film microstructure and the elemental diffusion/mixing within the Au/PSA interface obtained by scanning electron microscopy (SEM) and ion beam analysis techniques (RBS and ERD).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a finite-difference time-domain (FDTD) simulator for electromagnetic analysis and design applications in MRI. It is intended to be a complete FDTD model of an MRI system including all RF and low-frequency field generating units and electrical models of the patient. The pro-ram has been constructed in an object-oriented framework. The design procedure is detailed and the numerical solver has been verified against analytical solutions for simple cases and also applied to various field calculation problems. In particular, the simulator is demonstrated for inverse RF coil design, optimized source profile generation, and parallel imaging in high-frequency situations. The examples show new developments enabled by the simulator and demonstrate that the proposed FDTD framework can be used to analyze large-scale computational electromagnetic problems in modern MRI engineering. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Arsenic contamination of groundwater (0.05 to 0.84 mg/L) in Kuitun, Xinjiang was first found in 1970’s. Alternative clean surface water was introduced in 1985. We aimed to assess the exposure and heath outcome since the mitigation. In 2000, we collected a total of 360 urine samples from villagers from the endemic area and a nearby control area for arsenic (As), porphyrins and malondialdehyde (MDA) measurements. The averaged urinary As level of villagers from the endemic site (117±8.3 μg/g creatinine; 4.2 to 943.8 μg/g creat) was higher than that of the control site (73.6±3.2 μg/g creat). No significant differences were found in urinary porphyrins or MDA between the endemic and control sites. However, when the urinary arsenic was higher than 150 μg/g creat, these two biomarkers were higher in the exposed group than the control. Within the exposed group, villagers with arsenic-related skin symptoms had higher arsenic, uroporphyrin and MDA compared to those who had not shown symptoms. Sine the water mitigation, villagers whose urinary arsenic levels were 270 μg/g creat dropped from 20% to 10% of the population. Population with arsenic-related skin symptoms remained unchanged at 31%. We noted that 7.8% of those who had skin lesions were born after the implementation of intervention and that some villagers still prefer to drink the groundwater. Further, in the dry season, lack of surface water and electrical power breakdowns are to blame for failure to ensure continuous supply of clean water. It is concluded that despite the prompt action and successful water mitigation program to curb arsenic poisonings, it is essential to continue to monitor the health outcome of this population.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The development of TDR for measurement of soil water content and electrical conductivity has resulted in a large shift in measurement methods for a breadth of soil and hydrological characterization efforts. TDR has also opened new possibilities for soil and plant research. Five examples show how TDR has enhanced our ability to conduct our soil- and plant-water research. (i) Oxygen is necessary for healthy root growth and plant development but quantitative evaluation of the factors controlling oxygen supply in soil depends on knowledge of the soil water content by TDR. With water content information we have modeled successfully some impact of tillage methods on oxygen supply to roots and their growth response. (ii) For field assessment of soil mechanical properties influencing crop growth, water content capability was added to two portable soil strength measuring devices; (a) A TDT (Time Domain Transmittivity)-equipped soil cone penetrometer was used to evaluate seasonal soil strengthwater content relationships. In conventional tillage systems the relationships are dynamic and achieve the more stable no-tillage relationships only relatively late in each growing season; (b) A small TDR transmission line was added to a modified sheargraph that allowed shear strength and water content to be measured simultaneously on the same sample. In addition, the conventional graphing procedure for data acquisition was converted to datalogging using strain gauges. Data acquisition rate was improved by more than a factor of three with improved data quality. (iii) How do drought tolerant plants maintain leaf water content? Non-destructive measurement of TDR water content using a flat serpentine triple wire transmission line replaces more lengthy procedures of measuring relative water content. Two challenges remain: drought-stressed leaves alter salt content, changing electrical conductivity, and drought induced changes in leaf morphology affect TDR measurements. (iv) Remote radar signals are reflected from within the first 2 cm of soil. Appropriate calibration of radar imaging for soil water content can be achieved by a parallel pair of blades separated by 8 cm, reaching 1.7 cm into soil and forming a 20 cm TDR transmission line. The correlation between apparent relative permittivity from TDR and synthetic aperture radar (SAR) backscatter coefficient was 0.57 from an airborne flyover. These five examples highlight the diversity in the application of TDR in soil and plant research.