999 resultados para Electron accepting unit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concerning catheter-related infections, many studies have been conducted until the last consensus conference of the Sociétéde réanimation de langue française (SRLF) in 1994. This text is the synthesis of the considerable amount of work performed by the experts of the society to review recent studies. The experts' texts as well as extensive bibliography are available at http://www.srlf.org.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stable protein-DNA complexes can be assembled in vitro at the 5' end of Xenopus laevis vitellogenin genes using extracts of nuclei from estrogen-induced frog liver and visualized by electron microscopy. Complexes at the three following sites can be identified on the gene B2: the transcription initiation site, the estrogen responsive element (ERE) and in the first intron. The complex at the transcription initiation site is stabilized by dinucleotides and thus represents a ternary transcription complex. The formation of the complexes at the two other sites is enhanced by estrogen and is reduced by tamoxifen, an antagonist of estrogen, while this latter effect is reversed by adding an excess of hormone. No sequence homology is apparent between the site containing the ERE and the binding site in intron I and functional tests in MCF-7 cells suggest that these two sites are not equivalent. Finally, we made use of previously characterized deletion mutants of the 5' flanking region of the gene B1, a close relative of the gene B2, to demonstrate that the 13-bp palindromic core element of the ERE is involved in the formation of the complexes observed upstream of the transcription initiation site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are growing concerns on long-term health consequences, notably on fertility rates, of plasticizers such as phthalates. While di(2-ethylhexyl)phthalate (DEHP) is currently used in several medical devices, newborns in the neonatal intensive care unit are both more exposed and more vulnerable to DEHP. The objectives of this study were to identify, count, and describe possible sources of DEHP in a neonatal care unit. Our method consisted in the listing and the inspection of the information on packaging, complemented by contact with manufacturers when necessary. According to the results, 6% of all products and 10% of plastic products contained some DEHP; 71% of these involved respiratory support devices. A vast majority of the items showed no information on the content of DEHP. Further research is needed, particularly to determine the effects of such an early exposure and to study and develop safer alternatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Audit report on the Iowa Lottery Authority, a component unit of the State of Iowa, as of and for the year ended June 30, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Audit report of Iowa State University of Science and Technology, Ames, Iowa, (Iowa State University) and its discretely presented component unit as of and for the years ended June 30, 2015 and 2014

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correlative fluorescence and electron microscopy has become an indispensible tool for research in cell biology. The integrated Laser and Electron Microscope (iLEM) combines a Fluorescence Microscope (FM) and a Transmission Electron Microscope (TEM) within one set-up. This unique imaging tool allows for rapid identification of a region of interest with the FM, and subsequent high resolution TEM imaging of this area. Sample preparation is one of the major challenges in correlative microscopy of a single specimen; it needs to be apt for both FM and TEM imaging. For iLEM, the performance of the fluorescent probe should not be impaired by the vacuum of the TEM. In this technical note, we have compared the fluorescence intensity of six fluorescent probes in a dry, oxygen free environment relative to their performance in water. We demonstrate that the intensity of some fluorophores is strongly influenced by its surroundings, which should be taken into account in the design of the experiment. Furthermore, a freeze-substitution and Lowicryl resin embedding protocol is described that yields excellent membrane contrast in the TEM but prevents quenching of the fluorescent immuno-labeling. The embedding protocol results in a single specimen preparation procedure that performs well in both FM and TEM. Such procedures are not only essential for the iLEM, but also of great value to other correlative microscopy approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction and aim: Children hospitalised in a paediatric intensive care unit (PICU) are mainly fed by nutritional support (NS) which may often be interrupted. The aims of the study were to verify the relationship between prescribed (PEI) and actual energy intake (AEI) and to identify the reasons for NS interruption. Methods: Prospective study in a PICU. PEI and AEI from day 1 to 15, type of NS (enteral, parenteral, mixed), position of the feeding tube, interruptions in NS and reasons for these were noted. Inter - ruptions were classified in categories of barriers and their frequency and duration were analysed. Results: Fifteen children (24 ± 25.2 months) were studied for 84 days. The NS was exclusively enteral (69%) or mixed (31%). PEI were significantly higher than AEI (54.7 ± 32.9 vs 49.2 ± 33.6 kcal/kg, p = 0.0011). AEI represented 93% of the PEI. Ninety-eight interruptions were noted and lasted 189 h, i.e. 9.4% of the evaluated time. The most frequent barriers were nursing procedures, respiratory physiotherapy and unavailability of intravenous access. The longest were caused by the necessity to stop NS for surgery or diagnostic studies, to treat burns or to carry out medical procedures. Conclusion: AEI in PICU were inferior by 7% to PEI, considerably lower than in adult studies. Making these results available to medical staff for greater anticipation and compensation could reduce NS interruptions. Starving protocols should be reconsidered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Medication errors in hospitalsmay occur at any step of the medication process including prescription, transcription, preparation and administration, and may originate with any of the actors involved. Neonatal intensive care units (NICU) take care of extremely frail patients in whom errors could have dramatic consequences. Our objective was to assess the frequency and nature of medication errors in the NICU of a university hospital in order to propose measures for improvement.Materials & Methods The design was that of an observational prospective study over 4 consecutivemonths. All patients receiving C 3drugs were included. For each patient, observations during the different stages were compiled in a computer formulary and compared with the litterature. Setting: The 11-bed NICU of our university hospital.Main outcome measures:(a) Frequency and nature of medication errors in prescription,transcription, preparation and administration.(b) Drugs affected by errors.Results 83 patients were included. 505 prescriptions and transcriptions, 447 preparations and 464 administrations were analyzed. 220 medications errors were observed: 102 (46.4%) at prescription, 25 (11.4%) at transcription, 19 (8.6%) at preparation and 73 (33.2%) at administration. Uncomplete/ambiguous orders (24; 23.5%) were the most common errors observed at prescription, followed by wrong name (21; 20.6%), wrong dose (17; 16.7%) and omission (15; 14.7%). Wrong time (33; 45.2%) and wrong administration technique (31; 42.5%) were the most important medication errors during administration. According to the ATC classification, systemic antibacterials (53; 24.1%) were the most implicated, followed by perfusion solutions (40; 18.2%), respiratory system products (30; 13.6%), and mineral supplements and antithrombotic agents (20; 9.1%).Discussions, Conclusion Proposed recommendations: ? Better teaching of neonatal prescription to medical interns;? Improved prescription form to avoid omissions and ambiguities;? Development of a neonatal drug formulary, including prescription,preparation and administration modalities to reduce errors at different stages;? Presence of a clinical pharmacist in the NICU.Disclosure of Interest None Declared

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last two decades, the third-dimension has become a focus of attention in electron microscopy to better understand the interactions within subcellular compartments. Initially, transmission electron tomography (TEM tomography) was introduced to image the cell volume in semi-thin sections (∼500nm). With the introduction of the focused ion beam scanning electron microscope, a new tool, FIB-SEM tomography, became available to image much larger volumes. During TEM tomography and FIB-SEM tomography, the resin section is exposed to a high electron/ion dose such that the stability of the resin embedded biological sample becomes an important issue. The shrinkage of a resin section in each dimension, especially in depth, is a well-known phenomenon. To ensure the dimensional integrity of the final volume of the cell, it is important to assess the properties of the different resins and determine the formulation which has the best stability in the electron/ion beam. Here, eight different resin formulations were examined. The effects of radiation damage were evaluated after different times of TEM irradiation. To get additional information on mass-loss and the physical properties of the resins (stiffness and adhesion), the topography of the irradiated areas was analysed with atomic force microscopy (AFM). Further, the behaviour of the resins was analysed after ion milling of the surface of the sample with different ion currents. In conclusion, two resin formulations, Hard Plus and the mixture of Durcupan/Epon, emerged that were considerably less affected and reasonably stable in the electron/ion beam and thus suitable for the 3-D investigation of biological samples.