984 resultados para Efficiency Tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The seasonal stability tests of Canova & Hansen (1995) (CH) provide a method complementary to that of Hylleberg et al. (1990) for testing for seasonal unit roots. But the distribution of the CH tests are unknown in small samples. We present a method to numerically compute critical values and P-values for the CH tests for any sample size and any seasonal periodicity. In fact this method is applicable to the types of seasonality which are commonly in use, but also to any other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ENGLISH: Since the inception of the Inter-American Tropical Tuna Commission in 1950, one of the primary tasks of its scientific staff has been the collection and analysis of the statistics of total catch, effort expended in obtaining this catch, and the apparent abundance of yellowfin tuna (Neothunnus macropterus) and the skipjack tuna (Katsuwonus pelamis) in the Eastern Pacific Ocean. A concentrated effort by the staff during 1951 and 1952 resulted in the compilation of a series of historical data on the catch and catch-per-effort of tropical tunas for the years 1934-1950, and in the establishment of a detailed logbook system to monitor the current activities of the tuna fleets. Schaefer (1953) and Shimada and Schaefer (1956) have reviewed in detail the methods of collection and analysis of these data. Further studies, based on these and subsequently collected records, are contained in publications by Schaefer (1957), Shimada (1958), Alverson (1959, 1960), Griffiths (1960) and Calkins (1961). SPANISH: Desde que la Comisión Interamericana del Atún Tropical comenzó sus funciones en 1950, entre las más importantes tareas de su personal científico incluyó la recolección y análisis de las estadísticas de la captura total, del esfuerzo empleado en obtener esta captura y de la abundancia aparente de los atunes aleta amarilla (Neothunnus macropterus) y barriletes (Katsutvonus pelamis) en el Océano Pacífico Oriental. El concentrado esfuerzo del personal científico de la Comisión durante 1951 y 1952 dió como resultado la compilación de una serie de datos históricos sobre la captura de atunes tropicales y sobre la captura según el esfuerzo durante los años 1934 a 1950, así como el establecimiento de un sistema detallado de registro de las anotaciones en los cuadernos de bitácora para vigilar las actividades diarias de las flotas atuneras. Schaefer (1953) y Shimada y Schaefer (1956) han expuesto detalladamente los métodos de recolección y análisis de dichos datos. Otros estudios, basados en estos registros y en los recolectados posteriormente, se encuentran en las publicaciones de Schaefer (1957), Shimada (1958), Alverson (1959, 1960), Griffiths (1960) y Calkins (1961).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundamentally, action potentials in the squid axon are consequence of the entrance of sodium ions during the depolarization of the rising phase of the spike mediated by the outflow of potassium ions during the hyperpolarization of the falling phase. Perfect metabolic efficiency with a minimum charge needed for the change in voltage during the action potential would confine sodium entry to the rising phase and potassium efflux to the falling phase. However, because sodium channels remain open to a significant extent during the falling phase, a certain overlap of inward and outward currents is observed. In this work we investigate the impact of ion overlap on the number of the adenosine triphosphate (ATP) molecules and energy cost required per action potential as a function of the temperature in a Hodgkin–Huxley model. Based on a recent approach to computing the energy cost of neuronal action potential generation not based on ion counting, we show that increased firing frequencies induced by higher temperatures imply more efficient use of sodium entry, and then a decrease in the metabolic energy cost required to restore the concentration gradients after an action potential. Also, we determine values of sodium conductance at which the hydrolysis efficiency presents a clear minimum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the efficiency of fish diversion and survivorship of diverted fishes in the San Onofre Nuclear Generating Station Fish Return System in 1984 and 1985. Generally, fishes were diverted back to the ocean with high frequency, particularly in 1984. Most species were diverted at rates of 80% or more. Over 90% of the most abundant species, Engraulis mordax, were diverted. The system worked particularly well for strong-swimming forms such as Paralobrax clothratus, Atherinopsis californiensis, and Xenistius californiensis, and did not appreciably divert weaker-swimming species such as Porichthys notatus, Heterostichus rostratus, and Syngnathus sp. Return rates of some species were not as high in 1985 as in 1984. Individuals of most tested species survived both transit through the fish return system and 96 hours in a holding net. Some species, such as E. mordox, X. californiensis, and Umbrina roncador, experienced tittle or no mortality. Survivorship of Seriphus politus was highly variable and no Anchoa delicatissima survived. (PDF file contains 22 pages.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In eel catches with special small-mesh trawls the proportion of by-catch is unjustifiably high. From 2003 to 2005 eel trawls with various types of separation panels were designed, constructed, and tested under real fishing conditions. Tests were carried out using cover cod-ends and an underwater TV equipment. It was possible to reduce the amount of by-catch to one tenth of its usual amount. However, a decline of the catch efficiency for the target species eel could not be avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the construction, mathematical modeling and testing of a scaled universal hydraulic Power Take-Off (PTO) device for Wave Energy Converters (WECs). A specific prototype and test bench were designed and built to carry out the tests. The results obtained from these tests were used to adjust an in-house mathematical model. The PTO was initially designed to be coupled to a scaled wave energy capture device with a low speed and high torque oscillating motion and high power fluctuations. Any Energy Capture Device (ECD) that fulfils these requirements can be coupled to this PTO, provided that its scale is adequately defined depending on the rated power of the full scale prototype. The initial calibration included estimation of the pressure drops in the different components, the pressurization time of the oil inside the hydraulic cylinders and the volumetric efficiency of the complete circuit. Since the overall efficiency measured during the tests ranged from 0.69 to 0.8 and the dynamic performance of the PTO was satisfactory, the results are really promising and it is believed that this solution might prove effective in real devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the major concerns in an Intelligent Transportation System (ITS) scenario, such as that which may be found on a long-distance train service, is the provision of efficient communication services, satisfying users' expectations, and fulfilling even highly demanding application requirements, such as safety-oriented services. In an ITS scenario, it is common to have a significant amount of onboard devices that comprise a cluster of nodes (a mobile network) that demand connectivity to the outside networks. This demand has to be satisfied without service disruption. Consequently, the mobility of the mobile network has to be managed. Due to the nature of mobile networks, efficient and lightweight protocols are desired in the ITS context to ensure adequate service performance. However, the security is also a key factor in this scenario. Since the management of the mobility is essential for providing communications, the protocol for managing this mobility has to be protected. Furthermore, there are safety-oriented services in this scenario, so user application data should also be protected. Nevertheless, providing security is expensive in terms of efficiency. Based on this considerations, we have developed a solution for managing the network mobility for ITS scenarios: the NeMHIP protocol. This approach provides a secure management of network mobility in an efficient manner. In this article, we present this protocol and the strategy developed to maintain its security and efficiency in satisfactory levels. We also present the developed analytical models to analyze quantitatively the efficiency of the protocol. More specifically, we have developed models for assessing it in terms of signaling cost, which demonstrates that NeMHIP generates up to 73.47% less signaling compared to other relevant approaches. Therefore, the results obtained demonstrate that NeMHIP is the most efficient and secure solution for providing communications in mobile network scenarios such as in an ITS context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

GaInP/GaAs dual-junction solar cell with a conversion efficiency of 25.2% has been fabricated using metalorganic chemical vapor deposition (MOCVD) technique. Quantum efficiencies of the solar cell were measured within a temperature range from 25 to 160A degrees C. The results indicate that the quantum efficiencies of the subcells increase slightly with the increasing temperature. And red-shift phenomena of absorption limit for all subcells are observed by increasing the cell's work temperature, which are consistent with the viewpoint of energy gap narrowing effect. The short-circuit current density temperature coefficients dJ (sc)/dT of GaInP subcell and GaAs subcell are determined to be 8.9 and 7.4 mu A/cm(2)/A degrees C from the quantum efficiency data, respectively. And the open-circuit cell voltage temperature coefficients dV (oc)/dT calculated based on a theoretical equation are -2.4 mV/A degrees C and -2.1 mV/A degrees C for GaInP subcell and GaAs subcell.