674 resultados para ELUTING STENTS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study is to assess jailing of side branches (SB) by the everolimus-eluting, bioresorbable vascular scaffold (BVS) with 3-dimensional (3D) optical coherence tomography (OCT) reconstruction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recurrence of cardiovascular events and mortality remain high after acute coronary syndromes. A Swiss multicentric study, "Inflammation and acute coronary syndromes (ACS)--Novel strategies for prevention and clinical managements", is currently underway with the support of the Swiss National Science Foundation. The study includes a clinical research subproject of which the aim is to assess the impact of the ELIPS program (multi-dimEnsionaL prevention Program after acute coronary Syndrome) on the recurrence of cardiovascular events after an ACS. The basic research sub-projects aim to investigate novel cardiovascular risk biomarkers and genetic determinants of recurrence and to study the role of stem cells after an ACS. Another sub-project will evaluate intracoronary imaging techniques and the efficacy of different types of stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of self-expanding retrievable stents is an emerging and promising treatment strategy for acute stroke treatment. The concept combines the advantages of stent deployment with immediate flow-restoration and of mechanical thrombectomy with definitive thrombus removal. The present study was performed to gain more knowledge about the principle of combined flow restoration and thrombectomy in an established animal model using radiopaque thrombi evaluating efficiency, thrombus-device interaction and possible complications of the first dedicated flow-restoration and mechanical thrombectomy device.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The therapy of acute ischemic stroke aims at fast recanalization of the occluded brain vessel. In contrast to intravenous thrombolysis (IVT), endovascular approaches yield higher recanalization rates especially in large vessel occlusions. Mechanical thrombectomy with the Merci Retriever received FDA approval in 2004 as an adjunct to IVT or in the case of failed recanalization after IVT. The time window for treatment is 8 h from stroke onset. However, the recanalization rate was 55 %, still leaving space for further improvement. In addition to the Merci Retriever, the Penumbra System received FDA approval in 2008. The newest endovascular approach comprising retrievable intracranial stents results in an increased recanalization rate exceeding 90 % and has markedly reduced the time to recanalization. On the other hand, the complication rate has not increased yet. These promising results suggest a combined therapy for acute ischemic stroke. In a first step IVT can be started independently of the size of the treating hospital and in a next step the patient is transferred to a neuroradiological center. If vessel occlusion persists, additional endovascular recanalization is performed (bridging concept). Patients who don't qualify for IVT are candidates for mechanical thrombectomy up to 8 h after stroke onset.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the effectiveness and safety of covered stents for the management of iatrogenic arterial injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microvascular surgery has become an important method for reconstructing surgical defects due to trauma, tumors or after burn. The most important factor for successful free flap transfer is a well-executed anastomosis. The time needed to perform the anastomosis and the failure rate are not negligible despite the high level of operator's experience. During the history, many alternatives were tried to help the microsurgeon and to reduce the complications. A Medline literature search was performed to find articles dealing with non-suture methods of microvascular anastomosis. Many historical books were also included. The non-suture techniques can be divided into four groups based on the used mechanism of sutures: double intubation including tubes and stents, intubation-eversion including simple rings, double eversion including staples and double rings, and wall adjustement with adhesives or laser. All these techniques were able to produce a faster and easier microvascular anastomosis. Nevertheless, disadvantages of the suturless techniques include toxicity, high cost, leakage or aneurysm formation. More refinement is needed before their widespread adoption. Thus, laser-assisted microvascular anastomosis using 1,9 μm diode laser appeared to be a safe and reliable help for the microsurgeon and may be further developed in the near future.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acute BAO is a devastating neurological condition associated with a poor clinical outcome and a high mortality rate. Recanalization has been identified as a major prognostic factor for good outcome in BAO. Mechanical thrombectomy using retrievable stents is an emerging treatment option for acute stroke. First clinical trials using stent retrievers have shown promising high recanalization rates. However, these studies mainly included large artery occlusions in the anterior circulation with only a few or single cases of BAO. Therefore, the purpose of this study was to evaluate technical feasibility, safety, and efficacy of mechanical thrombectomy using retrievable stent in the treatment of acute BAO.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new era of stroke treatment may have begun with mechanical thrombectomy (MT) by fully deployed closed-cell self-expanding stents (stent-triever). Multiple case series and the first randomised controlled trials (RCTs) have now been published. More studies are under way involving large numbers of patients, which in turn has resulted in less strict "pragmatic" study protocols. Problems with current trials include a lack of standardisation in the conduct of the recanalisation procedure, the definition of primary endpoints such as the grade of arterial recanalisation and tissue reperfusion, and the post-surgical care provided. In Part 1 of this two part series, we outline the current situation and the major research questions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity, and in their backscattering ultrasound signal, identified as "pseudo dense-calcium" (DC) by VH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the main characteristics and treatment of urogenital manifestations in patients with Wegener granulomatosis (WG). We conducted a retrospective review of the charts of 11 patients with WG. All patients were men, and their median age at WG diagnosis was 53 years (range, 21-70 yr). Urogenital involvement was present at onset of WG in 9 cases (81%), it was the first clinical evidence of WG in 2 cases (18%), and was a symptom of WG relapse in 6 cases (54%). Symptomatic urogenital involvement included prostatitis (n = 4) (with suspicion of an abscess in 1 case), orchitis (n = 4), epididymitis (n = 1), a renal pseudotumor (n = 2), ureteral stenosis (n = 1), and penile ulceration (n = 1). Urogenital symptoms rapidly resolved after therapy with glucocorticoids and immunosuppressive agents. Several patients underwent a surgical procedure, either at the time of diagnosis (n = 3) (consisting of an open nephrectomy and radical prostatectomy for suspicion of carcinoma, suprapubic cystostomy for acute urinary retention), or during follow-up (n = 3) (consisting of ureteral double J stents for ureteral stenosis, and prostate transurethral resection because of dysuria). After a mean follow-up of 56 months, urogenital relapse occurred in 4 patients (36%). Urogenital involvement can be the first clinical evidence of WG. Some presentations, such as a renal or prostate mass that mimics cancer or an abscess, should be assessed to avoid unnecessary radical surgery. Urogenital symptoms can be promptly resolved with glucocorticoids and immunosuppressive agents. However, surgical procedures, such as prostatic transurethral resection, may be mandatory in patients with persistent symptoms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Restenosis has been the principal limitation of bare metal stents. Based upon the presumption that platelet and inflammatory cell recruitment initiate neointimal proliferation, we explored a novel polymer coating that reduces cell-stent interactions. The purpose of the present study was to investigate the effect of poly(L-lysine)-graft-poly(ethyleneglycol) (PLL-g-PEG) adsorbed to stent surfaces to reduce neointimal hyperplasia in the porcine restenosis model. METHODS AND RESULTS: Seven animals were instrumented each with 2 stainless steel stents (15 mm length, 2.5-3.5 mm diameter), randomly implanted in 1 major epicardial coronary artery. One stent was dip-coated with PLL-g-PEG, whereas the other stent served as the uncoated control stent. All animals were sacrificed after 6 weeks for histological examination. Neointimal hyperplasia was significantly less (-51%) in the PLL-g-PEG-coated stents (1.15 +/- 0.59 mm2) than in the uncoated control stents (2.33 +/- 1.01 mm2; p < 0.001). Conversely, lumen size was larger in the PLL-g-PEG-coated stents (2.91 +/- 1.17 mm2) than in the uncoated stents (2.04 +/- 0.64 mm2; p < 0.001). High magnification histomorphologic examination revealed no signs of inflammation or thrombus formation in either stent group. CONCLUSIONS: Polymeric steric stabilization of stents with PLL-g-PEG significantly reduces neointimal hyperplasia in the porcine restenosis model. Reduction of cell-stent interactions mediated by PLL-g-PEG appear to improve biocompatibility of stainless steel stents without evidence of adverse inflammatory or prothrombotic effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate selective and superselective catheter therapy of serious arterial damage associated with orthopedic surgery of the pelvis, hip joint, femur, and knee. MATERIALS AND METHODS: Between 1989 and 2005, 16 consecutive patients with arterial damage after orthopedic surgery (seven women, nine men; mean age, 62 years; age range, 21-82 y) underwent angiographic exploration. Seven patients were in hemodynamically unstable condition. Initial orthopedic procedures were iliac crest internal fixation (n = 1); total hip prosthesis (n = 3); revision of total hip prosthesis (n = 4); revision of acetabular cup prosthesis (n = 1); gamma-nailing, nail-plate fixation, or intramedullary nailing (n = 3); and total knee prosthesis (n = 4). RESULTS: Angiography showed pseudoaneurysms (n = 11), vascular lacerations with active extravasation (n = 3), and arteriovenous fistulas with extravasation (n = 2). After angiographic documentation of serious arterial injury, 14 patients were treated with a single or coaxial catheter technique in combination with coils alone, coils and polyvinyl alcohol particles, coils and Gelfoam pledgets, or Gelfoam pledgets; or balloon occlusion with isobutyl cyanoacrylate and coils. Two patients were treated with covered stents. In all, bleeding was effectively controlled in a single session in 16 patients, with immediate circulatory stabilization. Major complications included death, pulmonary embolism, and postprocedural hematoma. CONCLUSION: Selective and superselective catheter therapy may be used for effective, minimally invasive management of rare but potentially life-threatening vascular complications after orthopedic surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe the case of 77-year-old woman who underwent five coronary angiographies in 9 months due to in-stent re-stenosis of Cypher-Stents, and who finally required coronary artery bypass grafting surgery. Preoperative investigations revealed a significant internal carotid stenosis, which was due to a fractured and embolized Cypher-Stent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After 75 years of invasive and over 50 years of interventional cardiology, cardiac catheter-based procedures have become the most frequently used interventions of modern medicine. Patients undergoing a percutaneous coronary intervention (PCI) outnumber those with coronary artery bypass surgery by a factor of 2 to 4. The default approach to PCI is the implantation of a (drug-eluting) stent, in spite of the fact that it improves the results of balloon angioplasty only in about 25% of cases. The dominance of stenting over conservative therapy or balloon angioplasty on one hand and bypass surgery on the other hand is a flagrant example of how medical research is digested an applied in real life. Apart from electrophysiological interventions, closure ot the patent foramen ovale and percutaneous replacement of the aortic valve in the elderly have the potential of becoming daily routine procedures in catheterization laboratories around the world. Stem cell regeneration of vessels or heart muscle, on the other hand, may remain a dream never to come true.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We aimed at assessing stent geometry and in-stent contrast attenuation with 64-slice CT in patients with various coronary stents. Twenty-nine patients (mean age 60 +/- 11 years; 24 men) with 50 stents underwent CT within 2 weeks after stent placement. Mean in-stent luminal diameter and reference vessel diameter proximal and distal to the stent were assessed with CT, and compared to quantitative coronary angiography (QCA). Stent length was also compared to the manufacturer's values. Images were reconstructed using a medium-smooth (B30f) and sharp (B46f) kernel. All 50 stents could be visualized with CT. Mean in-stent luminal diameter was systematically underestimated with CT compared to QCA (1.60 +/- 0.39 mm versus 2.49 +/- 0.45 mm; P < 0.0001), resulting in a modest correlation of QCA versus CT (r = 0.49; P < 0.0001). Stent length as given by the manufacturer was 18.2 +/- 6.2 mm, correlating well with CT (18.5 +/- 5.7 mm; r = 0.95; P < 0.0001) and QCA (17.4 +/- 5.6 mm; r = 0.87; P < 0.0001). Proximal and distal reference vessel diameters were similar with CT and QCA (P = 0.06 and P = 0.03). B46f kernel images showed higher image noise (P < 0.05) and lower in-stent CT attenuation values (P < 0.001) than images reconstructed with the B30f kernel. 64-slice CT allows measurement of coronary artery in-stent density, and significantly underestimates the true in-stent diameter compared to QCA.