921 resultados para DC link voltage regulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voltage Unbalance (VU) is a power quality issue arising within the low voltage residential distribution networks due to the random location and rating of single-phase rooftop photovoltaic cells (PVs). In this paper, an analysis has been carried out to investigate how PV installations, their random location and power generation capacity can cause an increase in VU. Several efficient practical methods are discussed for VU reduction. Based on this analysis, it has been shown that the installation of a DSTATCOM can reduce VU. In this paper, the best possible location for DSTATCOM and its efficient control method to reduce VU will be presented. The results are verified through PSCAD/EMTDC and Monte Carlo simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper demonstrates a model of self-regulation based on a qualitative research project with adult learners undertaking an undergraduate degree. The narrative about the participant’s life transitions, co-constructed with the researcher, yielded data about their generalised self-efficacy and resulted in a unique self-efficacy narrative for each participant. A model of self-regulation is proposed with potential applications for coaching, counselling and psychotherapy. A narrative method was employed to construct narratives about an individual’s self-efficacy in relation to their experience of learning and life transitions. The method involved a cyclical and iterative process using qualitative interviews to collect life history data from participants. In addition, research participants completed reflective homework tasks, and this data was included in the participant’s narratives. A highly collaborative method entailed narratives being co-constructed by researcher and research participants as the participants were guided in reflecting on their experience in relation to learning and life transitions; the reflection focused on behaviour, cognitions and emotions that constitute a sense of self-efficacy. The analytic process used was narrative analysis, in which life is viewed as constructed and experienced through the telling and retelling of stories and hence the analysis is the creation of a coherent and resonant story. The method of constructing self-efficacy narratives was applied to a sample of mature aged students starting an undergraduate degree. The research outcomes confirmed a three-factor model of self-efficacy, comprising three interrelated stages: initiating action, applying effort, and persistence in overcoming difficulties. Evaluation of the research process by participants suggested that they had gained an enhanced understanding of self-efficacy from their participation in the research process, and would be able to apply this understanding to their studies and other endeavours in the future. A model of self-regulation is proposed as a means for coaches, counsellors and psychotherapists working from a narrative constructivist perspective to assist clients facing life transitions by helping them generate selfefficacious cognitions, emotions and behaviour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dwell times at stations and inter-station run times are the two major operational parameters to maintain train schedule in railway service. Current practices on dwell-time and run-time control are that they are only optimal with respect to certain nominal traffic conditions, but not necessarily the current service demand. The advantages of dwell-time and run-time control on trains are therefore not fully considered. The application of a dynamic programming approach, with the aid of an event-based model, to devise an optimal set of dwell times and run times for trains under given operational constraints over a regional level is presented. Since train operation is interactive and of multi-attributes, dwell-time and run-time coordination among trains is a multi-dimensional problem. The computational demand on devising trains' instructions, a prime concern in real-time applications, is excessively high. To properly reduce the computational demand in the provision of appropriate dwell times and run times for trains, a DC railway line is divided into a number of regions and each region is controlled by a dwell- time and run-time controller. The performance and feasibility of the controller in formulating the dwell-time and run-time solutions for real-time applications are demonstrated through simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expoxy nanocomposites with multiwell carbon nanotubes (mwcnts) filler up to 0.3%wt were prepared by sheer mixing and good dispersion of the MWCNTS in the epoxy was successfully achieved. The electrical behaviour was characterized by measurements of the alternating current (ac) and direct current (dc) conductives at room temperature. Typical percolation behaviour was observed at a low percolation threshold of 0.055%. Frequency independent ac conductivity was observed at low frequencies but not at high frequencies. An equivalent circuit models was used to predict the impedence response in these nanocomposites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a high voltage pulsed power system based on low voltage switch-capacitor units connected to a current source for several applications such as plasma systems. A modified positive buck-boost converter topology is used to utilize the current source concept and a series of low voltage switch-capacitor units is connected to the current source in order to provide high voltage with high voltage stress (dv/dt) as demanded by loads. This pulsed power converter is flexible in terms of energy control, in that the stored energy in the current source can be adjusted by changing the current magnitude to significantly improve the efficiency of various systems with different requirements. Output voltage magnitude and stress (dv/dt) can be controlled by a proper selection of components and control algorithm to turn on and off switching devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improving efficiency and flexibility in pulsed power supply technologies is the most substantial concern of pulsed power systems specifically with regard to plasma generation. Recently, the improvement of pulsed power supply has become of greater concern due to the extension of pulsed power applications to environmental and industrial areas. With this respect, a current source based topology is proposed in this paper as a pulsed power supply which gives the possibility of power flow control during load supplying mode. The main contribution in this configuration is utilization of low-medium voltage semiconductor switches for high voltage generation. A number of switch-diode-capacitor units are designated at the output of topology to exchange the current source energy into voltage form and generate a pulsed power with sufficient voltage magnitude and stress. Simulations carried out in Matlab/SIMULINK platform as well as experimental tests on a prototype setup have verified the capability of this topology in performing desired duties. Being efficient and flexible are the main advantages of this topology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the use of renewable energy sources (RESs) increases worldwide, there is a rising interest on their impacts on power system operation and control. An overview of the key issues and new challenges on frequency regulation concerning the integration of renewable energy units into the power systems is presented. Following a brief survey on the existing challenges and recent developments, the impact of power fluctuation produced by variable renewable sources (such as wind and solar units) on sysstem frequency performance is also presented. An updated LFC model is introduced, and power system frequency response in the presence of RESs and associated issues is analysed. The need for the revising of frequency performance standards is emphasised. Finally, non-linear time-domain simulations on the standard 39-bus and 24-bus test systems show that the simulated results agree with those predicted analytically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To maximise the capacity of the rail lineand provide a reliable service for pas-sengers throughout the day, regulation of train service to maintain steady service headway is es-sential. In most current metro systems, train usually starts coasting at a fixed distance from the departed station to achieve service regulation. However, this approach is only effective with re-spect to a nominal operational condition of train schedule but not necessarily the current service demand. Moreover, it is not simply to identify the necessary starting point for coasting under the run time constraints of current service conditions since train movement is attributed by a large number of factors, most of which are non-linear and inter-dependent. This paper presents an ap-plication of classical measures to search for the appropriate coasting point to meet a specified inter-station run time and they can be integrated in the on-board Automatic Train Operation (ATO) system and have the potential for on-line implementation in making a set of coasting command decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - This chapter examines individual and collective quests for authenticity, as experienced through consumption activities within an urban neighbourhood. It investigates the interplay between consumption experiences as authenticating acts and authoritative performances (Arnould and Price 2000), and considers the implications with regard to Zukin’s (2010) theories on urban authenticity, and how it may be experienced as new beginnings and origins. Methodology - The chapter is based on autoethnographic research that explores how interaction and identity definition within servicescapes can work to construct place-based community. Findings - It describes how a servicescape of new beginnings offered opportunities for individual authentication that also enabled personal identification with a specific cultural group. This authentication drew on the cultural capital embedded in such locations, including their association with gentrification. This is contrast with the collective identification offered by a servicescape operating as a place of exposure. This site of origins displayed the social practices of a different demographic, which worked to highlight a relational link between the authentication practices of the broader neighbourhood. These sites also worked cumulatively, to highlight the inauthenticities within my identification practices and offer opportunities for redress. Through this interplay it was possible to establish an authentic sense of neighbourhood that drew on its new beginnings and its origins, and was both individual and collective. Originality - Through the combination of urban and consumption-based perspectives of authenticity, and an autoethnographic methodology, this chapter offers a different insight into the ways identification with, and attachment to, a neighbourhood can develop through consumption experiences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AC motors are largely used in a wide range of modern systems, from household appliances to automated industry applications such as: ventilations systems, fans, pumps, conveyors and machine tool drives. Inverters are widely used in industrial and commercial applications due to the growing need for speed control in ASD systems. Fast switching transients and the common mode voltage, in interaction with parasitic capacitive couplings, may cause many unwanted problems in the ASD applications. These include shaft voltage and leakage currents. One of the inherent characteristics of Pulse Width Modulation (PWM) techniques is the generation of the common mode voltage, which is defined as the voltage between the electrical neutral of the inverter output and the ground. Shaft voltage can cause bearing currents when it exceeds the amount of breakdown voltage level of the thin lubricant film between the inner and outer rings of the bearing. This phenomenon is the main reason for early bearing failures. A rapid development in power switches technology has lead to a drastic decrement of switching rise and fall times. Because there is considerable capacitance between the stator windings and the frame, there can be a significant capacitive current (ground current escaping to earth through stray capacitors inside a motor) if the common mode voltage has high frequency components. This current leads to noises and Electromagnetic Interferences (EMI) issues in motor drive systems. These problems have been dealt with using a variety of methods which have been reported in the literature. However, cost and maintenance issues have prevented these methods from being widely accepted. Extra cost or rating of the inverter switches is usually the price to pay for such approaches. Thus, the determination of cost-effective techniques for shaft and common mode voltage reduction in ASD systems, with the focus on the first step of the design process, is the targeted scope of this thesis. An introduction to this research – including a description of the research problem, the literature review and an account of the research progress linking the research papers – is presented in Chapter 1. Electrical power generation from renewable energy sources, such as wind energy systems, has become a crucial issue because of environmental problems and a predicted future shortage of traditional energy sources. Thus, Chapter 2 focuses on the shaft voltage analysis of stator-fed induction generators (IG) and Doubly Fed Induction Generators DFIGs in wind turbine applications. This shaft voltage analysis includes: topologies, high frequency modelling, calculation and mitigation techniques. A back-to-back AC-DC-AC converter is investigated in terms of shaft voltage generation in a DFIG. Different topologies of LC filter placement are analysed in an effort to eliminate the shaft voltage. Different capacitive couplings exist in the motor/generator structure and any change in design parameters affects the capacitive couplings. Thus, an appropriate design for AC motors should lead to the smallest possible shaft voltage. Calculation of the shaft voltage based on different capacitive couplings, and an investigation of the effects of different design parameters are discussed in Chapter 3. This is achieved through 2-D and 3-D finite element simulation and experimental analysis. End-winding parameters of the motor are also effective factors in the calculation of the shaft voltage and have not been taken into account in previous reported studies. Calculation of the end-winding capacitances is rather complex because of the diversity of end winding shapes and the complexity of their geometry. A comprehensive analysis of these capacitances has been carried out with 3-D finite element simulations and experimental studies to determine their effective design parameters. These are documented in Chapter 4. Results of this analysis show that, by choosing appropriate design parameters, it is possible to decrease the shaft voltage and resultant bearing current in the primary stage of generator/motor design without using any additional active and passive filter-based techniques. The common mode voltage is defined by a switching pattern and, by using the appropriate pattern; the common mode voltage level can be controlled. Therefore, any PWM pattern which eliminates or minimizes the common mode voltage will be an effective shaft voltage reduction technique. Thus, common mode voltage reduction of a three-phase AC motor supplied with a single-phase diode rectifier is the focus of Chapter 5. The proposed strategy is mainly based on proper utilization of the zero vectors. Multilevel inverters are also used in ASD systems which have more voltage levels and switching states, and can provide more possibilities to reduce common mode voltage. A description of common mode voltage of multilevel inverters is investigated in Chapter 6. Chapter 7 investigates the elimination techniques of the shaft voltage in a DFIG based on the methods presented in the literature by the use of simulation results. However, it could be shown that every solution to reduce the shaft voltage in DFIG systems has its own characteristics, and these have to be taken into account in determining the most effective strategy. Calculation of the capacitive coupling and electric fields between the outer and inner races and the balls at different motor speeds in symmetrical and asymmetrical shaft and balls positions is discussed in Chapter 8. The analysis is carried out using finite element simulations to determine the conditions which will increase the probability of high rates of bearing failure due to current discharges through the balls and races.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, two different high bandwidth converter control strategies are discussed. One of the strategies is for voltage control and the other is for current control. The converter, in each of the cases, is equipped with an output passive filter. For the voltage controller, the converter is equipped with an LC filter, while an output has an LCL filter for current controller. The important aspect that has been discussed the paper is to avoid computation of unnecessary references using high-pass filters in the feedback loop. The stability of the overall system, including the high-pass filters, has been analyzed. The choice of filter parameters is crucial for achieving desirable system performance. In this paper, the bandwidth of achievable performance is presented through frequency (Bode) plot of the system gains. It has been illustrated that the proposed controllers are capable of tracking fundamental frequency components along with low-order harmonic components. Extensive simulation results are presented to validate the control concepts presented in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The term ‘driving self-restriction’ is used in the road safety literature to describe the behaviour of some older drivers. It includes the notion that older drivers will avoid driving in specific, usually self-identified situations, such as those in which safety is compromised. We sought to identify the situations that older drivers report avoiding; and, to determine the adequacy of a key measure of such behaviour. A sample of 75 drivers aged 65 years and older completed Baldock et al.’s modification of the Driving Habits Questionnaire avoidance items (Baldock et al., 2006), the Driving Behaviour Questionnaire, and open-ended items that elicited written descriptions of the most and least safe driving situation. Consistent with previous results, we found a relatively low level of driving self-restriction and infrequent episodes of aggressive violations. However, when combined with the situation descriptions, these data suggest that Driving Habits Questionnaire did not cover all of the situations that older drivers might choose avoid. We suggest that a new avoidance scale is needed and we present a new item pool that may be used for this purpose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The insurance industry discharges a critical role in the Australian economy and is a significant part of the Australian financial services market. The industry relies upon intermediaries, the principal types being brokers and agents, to promote, arrange and distribute their products and services in the market. The pivotal role that they play in this context and sensitivities associated with the consumer oriented products, such as house and contents insurance, has ensured close regulatory attention. Of particular importance was the passage of the Insurance (Agents and Brokers) Act 1984 (Cth), a comprehensive attempt to address the responsibilities of intermediaries as well as particular problem areas associated with the handling of money. However, with the introduction of financial services and market reform early in the new millennium this insurance intermediary specific regulatory approach was abandoned in favour of a market-wide strategy; that is, market reform was based upon across-the-board licensing, disclosure, conduct and fairness standards, and all financial products and services are now regulated at a generic level under Ch 7 of the Corporations Act 2001 (Cth). This article briefly explores the categories of insurance intermediaries and the relevant distinctions between them but focuses mainly upon the regulatory context in which they operate. This context transcends a strictly legal framework as the regulatory body, the Australian Securities and Investments Commission (ASIC), has sought to inform and guide the market through Policy Statements and Regulatory Guides. The usefulness of these guides as an adjunct to the legislation in explaining the scope and operation of regulatory framework is examined. In addition, the article looks at the self-regulatory and dispute resolution practices in this area and their impact. In conclusion an assessment of this across-the-board regulatory regime is advanced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Nonverbal Learning Disability is believed to be caused by damage, disorder or destruction of neuronal white matter in the brain’s right hemisphere and may be seen in persons experiencing a wide range of neurological diseases such as hydrocephalus and other types of brain injury (Harnadek & Rourke 1994). This article probes the relationship between shunted hydrocephalus and Nonverbal Learning Disability. Description of hydrocephalus and intelligence associated with hydrocephalus concludes with explication of the ‘final common pathway’ that links residual damage caused by the hydrocephalic condition to a Nonverbal Learning Disability (Rourke & Del Dotto 1994, p. 37). The paper seeks to assist teachers, teacher aides, psychologists, guidance officers, support workers, parents and disability service providers whose role is to understand and advocate for individuals with shunted hydrocephalus and spina bifida.