758 resultados para Cost-effective methods
Resumo:
Two energy grass species, switch grass, a North American tuft grass, and reed canary grass, a European native, are likely to be important sources of biomass in Western Europe for the production of biorenewable energy. Matching chemical composition to conversion efficiency is a primary goal for improvement programmes and for determining the quality of biomass feed-stocks prior to use and there is a need for methods which allow cost effective characterisation of chemical composition at high rates of sample through-put. In this paper we demonstrate that nitrogen content and alkali index, parameters greatly influencing thermal conversion efficiency, can be accurately predicted in dried samples of these species grown under a range of agronomic conditions by partial least square regression of Fourier transform infrared spectra (R2 values for plots of predicted vs. measured values of 0.938 and 0.937, respectively). We also discuss the prediction of carbon and ash content in these samples and the application of infrared based predictive methods for the breeding improvement of energy grasses.
Resumo:
A range of chromia pillared montmorillonite and tin oxide pillared laponite clay catalysts, as well as new pillared clay materials such as cerium and europium oxide pillared montmorillonites were synthesised. Methods included both conventional ion exchange techniques and microwave enhanced methods to improve performance and/or reduce preparation time. These catalytic materials were characterised in detail both before and after use in order to study the effect of the preparation parameters (starting material, preparation method, pillaring species, hydroxyl to metal ratio etc.) and the hydro cracking procedure on their properties. This led to a better understanding of the nature of their structure and catalytic operation. These catalysts were evaluated with regards to their performance in hydrocracking coal derived liquids in a conventional microbomb reactor (carried out at Imperial College). Nearly all catalysts displayed better conversions when reused. The chromia pillared montmorillonite CM3 and the tin oxide pillared laponite SL2a showed the best "conversions". The intercalation of chromium in the form of chromia (Cr203) in the interlayer clearly increased conversion. This was attributed to the redox activity of the chromia pillar. However, this increase was not proportional to the increase in chromium content or basal spacing. In the case of tin oxide pillared laponite, the catalytic activity might have been a result of better access to the acid sites due to the delaminated nature of laponite, whose activity was promoted by the presence of tin oxide. The manipulation of the structural properties of the catalysts via pillaring did not seem to have any effect on the catalysts' activity. This was probably due to the collapse of the pillars under hydrocracking conditions as indicated by the similar basal spacing of the catalysts after use. However, the type of the pillaring species had a significant effect on conversion. Whereas pillaring with chromium and tin oxides increased the conversion exhibited by the parent clays, pillaring with cerium and europium oxides appeared to have a detrimental effect. The relatively good performance of the parent clays was attributed to their acid sites, coupled with their macropores which are able to accommodate the very high molecular mass of coal derived liquids. A microwave reactor operating at moderate conditions was modified for hydro cracking coal derived liquids and tested with the conventional catalyst NiMo on alumina. It was thought that microwave irradiation could enable conversion to occur at milder conditions than those conventionally used, coupled with a more effective use of hydrogen. The latter could lead to lower operating costs making the process cost effective. However, in practice excessive coke deposition took place leading to negative total conversion. This was probably due to a very low hydrogen pressure, unable to have any hydro cracking effect even under microwave irradiation. The decomposition of bio-oil under microwave irradiation was studied, aiming to identify the extent to which the properties of bio-oil change as a function of time, temperature, mode of heating, presence of char and catalyst. This information would be helpful not only for upgrading bio-oil to transport fuels, but also for any potential fuel application. During this study the rate constants of bio-oil's decomposition were calculated assuming first order kinetics.
Resumo:
Most parametric software cost estimation models used today evolved in the late 70's and early 80's. At that time, the dominant software development techniques being used were the early 'structured methods'. Since then, several new systems development paradigms and methods have emerged, one being Jackson Systems Development (JSD). As current cost estimating methods do not take account of these developments, their non-universality means they cannot provide adequate estimates of effort and hence cost. In order to address these shortcomings two new estimation methods have been developed for JSD projects. One of these methods JSD-FPA, is a top-down estimating method, based on the existing MKII function point method. The other method, JSD-COCOMO, is a sizing technique which sizes a project, in terms of lines of code, from the process structure diagrams and thus provides an input to the traditional COCOMO method.The JSD-FPA method allows JSD projects in both the real-time and scientific application areas to be costed, as well as the commercial information systems applications to which FPA is usually applied. The method is based upon a three-dimensional view of a system specification as opposed to the largely data-oriented view traditionally used by FPA. The method uses counts of various attributes of a JSD specification to develop a metric which provides an indication of the size of the system to be developed. This size metric is then transformed into an estimate of effort by calculating past project productivity and utilising this figure to predict the effort and hence cost of a future project. The effort estimates produced were validated by comparing them against the effort figures for six actual projects.The JSD-COCOMO method uses counts of the levels in a process structure chart as the input to an empirically derived model which transforms them into an estimate of delivered source code instructions.
Resumo:
Since 1988, quasi-markets have been introduced into many areas of social policy in the UK, the NHS internal market is one example. Markets operate by price signals. The NHS Internal Market, if it is to operate efficiently, requires purchasers and providers to respond to price signals. The research hypothesis is - cost accounting methods can be developed to enable healthcare contracts to be priced on a cost-basis in a manner which will facilitate the achievement of economic efficiency in the NHS internal market. Surveys of hospitals in 1991 and 1994 established the cost methods adopted in deriving the prices for healthcare contracts in the first year of the market and three years on. An in-depth view of the costing for pricing process was gained through case studies. Hospitals had inadequate cost information on which to price healthcare contracts at the inception of the internal market: prices did not reflect the relative performance of healthcare providers sufficiently closely to enable the market's espoused efficiency aims to be achieved. Price variations were often due to differing costing approaches rather than efficiency. Furthermore, price comparisons were often meaningless because of inadequate definition of the services (products). In April 1993, the NHS Executive issued guidance on costing for contracting to all NHS providers in an attempt to improve the validity of price comparisons between alternative providers. The case studies and the 1994 survey show that although price comparison has improved, considerable problems remain. Consistency is not assured, and the problem of adequate product definition is still to be solved. Moreover, the case studies clearly highlight the mismatch of rigid, full-cost pricing rules with both the financial management considerations at local level and the emerging internal market(s). Incentives exist to cost-shift, and healthcare prices can easily be manipulated. In the search for a new health policy paradigm to replace traditional bureaucratic provision, cost-based pricing cannot be used to ensure a more efficient allocation of healthcare resources.
Resumo:
This research was originally undertaken to aid the Jamaican government and the World Bank in making funding decisions relative to improvement of road systems and traffic control in Jamaica. An investigation of the frequency and causes of road accidents and an evaluation of their impact on the Jamaican economy were carried out, and a model system which might be applied was developed. It is believed that the importance of road accident economic and manpower losses to the survival of developing countries, such as Jamaica, cannot be overemphasized. It is suggested that the World Bank, in cooperation with national governments, has a role to play in alleviating this serious problem. Data was collected from such organizations as the Jamaica Ministry of Construction, Police Department, the World Bank, and the World Health Organization. A variety of methodologies were utilized to organize this data in useful and understandable forms. The most important conclusion of this research is that solvable problems in road systems and in traffic control result in the unnecessary loss of useful citizens, in both developed and developing countries. However, a lack of information and understanding regarding the impact of high rates of road accident death and injury on the national economy and stability of a country results in an apparent lack of concern. Having little internal expertise in the field of road accident prevention, developing countries usually hire consultants to help them address this problem. In the case of Jamaica, this practice has resulted in distrust and hard feelings between the Jamaican authorities and major organizations involved in the field. Jamaican officials have found confusing the recommendations of most experts contracted to study traffic safety. The attempts of foreign consultants to utilize a technological approach (the use of coding systems and computers), methods which do not appear cost-effective for Jamaica, have resulted in the expenditure of limited funds for studies which offer no feasible approach to the problem. This funding limitation, which hampers research and road improvement, could be alleviated by such organizations as the World Bank. The causes of high accident rates are many, it was found. Formulation of a plan to address this serious problem must take into account the current failure to appreciate the impact of a high level of road accidents on national economy and stability, inability to find a feasible approach to the problem, and inadequate funding. Such a plan is discussed in detail in the main text of this research.
Resumo:
World and UK energy resources and use are reviewed and the role of energy conservation in energy policy identified. In considering various energy conservation measures, a distinction is made between energy intensive and non-intensive industries and also between direct and indirect uses of energy. Particular attention is given to the non-intensive user of energy. Energy use on one such industrial site has been studied to determine the most effective energy saving measures in the short term. Here it is estimated that over 65% of energy is consumed for indirect purposes, mainly for heating and lighting buildings. Emphasis is placed on energy auditing techniques and those energy saving measures requiring greater technical, economic and organisational resources to secure their implementation. Energy auditing techniques include the use of aerial thermography and snow formation surveys to detect heat losses. Qualitative and quantitative interpretations are carried out, but restricted mainly to evaluating building roof heat losses. From the energy auditing exercise, it is confirmed that the intermittent heating of buildings is the largest and most cost effective fuel saving measure. This was implemented on the site and a heat monitoring programme established to verify results. Industrial combined heat and power generation is investigated. A proposal for the site demonstrates that there are several obstacles to its successful implementation. By adopting an alternative financial rationale, a way of overcoming these obstacles is suggested. A useful by-product of the study is the classification of industrial sites according to the nature of industrial energy demand patterns. Finally, energy saving measures implemented on the site are quantlfied using comparative verification methods. Overall fuel savings of 13% are indicated. Cumulative savings in heating fuel amount to 26% over four years although heated area increased by approximately 25%.
Resumo:
Background - Delivery of high-quality, evidence-based health care to deprived sectors of the community is a major goal for society. We investigated the effectiveness of a culturally sensitive, enhanced care package in UK general practices for improvement of cardiovascular risk factors in patients of south Asian origin with type 2 diabetes. Methods - In this cluster randomised controlled trial, 21 inner-city practices in the UK were assigned by simple randomisation to intervention (enhanced care including additional time with practice nurse and support from a link worker and diabetes-specialist nurse [nine practices; n=868]) or control (standard care [12 practices; n=618]) groups. All adult patients of south Asian origin with type 2 diabetes were eligible. Prescribing algorithms with clearly defined targets were provided for all practices. Primary outcomes were changes in blood pressure, total cholesterol, and glycaemic control (haemoglobin A1c) after 2 years. Analysis was by intention to treat. This trial is registered, number ISRCTN 38297969. Findings - We recorded significant differences between treatment groups in diastolic blood pressure (1·91 [95% CI -2·88 to -0·94] mm?Hg, p=0·0001) and mean arterial pressure (1·36 [-2·49 to -0·23] mm?Hg, p=0·0180), after adjustment for confounders and clustering. We noted no significant differences between groups for total cholesterol (0·03 [-0·04 to 0·11] mmol/L), systolic blood pressure (-0·33 [-2·41 to 1·75] mm?Hg), or HbA1c (-0·15% [-0·33 to 0·03]). Economic analysis suggests that the nurse-led intervention was not cost effective (incremental cost-effectiveness ratio £28?933 per QALY gained). Across the whole study population over the 2 years of the trial, systolic blood pressure, diastolic blood pressure, and cholesterol decreased significantly by 4·9 (95% CI 4·0–5·9) mm?Hg, 3·8 (3·2–4·4) mm?Hg, and 0·45 (0·40–0·51) mmol/L, respectively, and we recorded a small and non-significant increase for haemoglobin A1c (0·04% [-0·04 to 0·13]), p=0·290). Interpretation - We recorded additional, although small, benefits from our culturally tailored care package that were greater than the secular changes achieved in the UK in recent years. Stricter targets in general practice and further measures to motivate patients are needed to achieve best possible health-care outcomes in south Asian patients with diabetes. Funding - Pfizer, Sanofi-Aventis, Servier Laboratories UK, Merck Sharp & Dohme/Schering-Plough, Takeda UK, Roche, Merck Pharma, Daiichi-Sankyo UK, Boehringer Ingelheim, Eli Lilly, Novo Nordisk, Bristol-Myers Squibb, Solvay Health Care, and Assurance Medical Society UK.
Resumo:
Free paper session INTRODUCTION. Microaneurysms and haemorrhages within the macula area are a poor predictor of macular oedema as shown by optical coherence tomography (OCT). Our research suggests that it is safe and cost effective to screen patients who present with these surrogate markers annually. PURPOSE. To determine whether microaneurysms (ma) and haemorrhages (hm) within one optic disc diameter of the fovea (ma/hm<1DD) are significant predictors of macular oedema. METHODS. Data were collected over a one-year period from patients attending digital diabetic retinopathy screening. Patients who presented with ma/hm<1DD also had an OCT scan. The fast macula scan on the Stratus OCT was used and an ophthalmologist reviewed the scans to determine whether macular oedema was present. Macular oedema was identified by thickening on the OCT cross-sections. Patients were split into two groups. Group one (325 eyes) included those with best VA?6/9 and group two (30 eyes) with best VA =6/12. Only patients who had no other referable features of diabetic retinopathy were selected. RESULTS. In group one, 6 (1.8%) out of 325 eyes showed thickening on the OCT and were referred to hospital eye service (HES) for further investigation. In group two, 6 (20%) out of 30 eyes showed thickening and were referred to HES. CONCLUSIONS. Ma/hm<1DD become more significant predictors of macular oedema when VA is reduced. Results confirm the grading criteria concerning microaneurysms predicting macular oedema for referable maculopathy in the English national screening programme. OCT is a useful method to accurately identify patients requiring referral to HES.
Resumo:
Introduction: Orally disintegrating tablets (ODTs) have emerged as one of the novel solid oral dosage forms with a potential to deliver a wide range of drug candidates to both paediatric and geriatric patient populations. Of the plethora of available technologies, compression of excipients offers a cost-effective and translatable methodology for the manufacture of ODTs. Areas covered: The review is a modest endeavour from the authors to assemble literature published over the last couple of decades on formulation development of compressed ODT. It describes the main ODT excipients used since the introduction of this dosage form in the 1990s and explores the switch from cellulose-based excipients towards sugar/polyols. Furthermore, it unfolds the key properties of ODT fillers, binders and disintegrants with an emphasis on their advantages and drawbacks. The review also provides a critical assessment of the various strategies employed for performance enhancement of compressed ODT with a focus on the underlying mechanisms for fast disintegration and acceptable mechanical strength. Expert opinion: Recent increase in the total number of compression-based technologies for ODT development promises to reduce the manufacturing cost of this dosage form in the future. However, some of the developed methods may affect the stability of tablets due to susceptibility to moisture, collapse of pores or the generation of less stable polymorphs which require rigorous testing prior to commercialization. © 2013 Informa UK, Ltd.
Resumo:
OBJECTIVE: To determine the accuracy, acceptability and cost-effectiveness of polymerase chain reaction (PCR) and optical immunoassay (OIA) rapid tests for maternal group B streptococcal (GBS) colonisation at labour. DESIGN: A test accuracy study was used to determine the accuracy of rapid tests for GBS colonisation of women in labour. Acceptability of testing to participants was evaluated through a questionnaire administered after delivery, and acceptability to staff through focus groups. A decision-analytic model was constructed to assess the cost-effectiveness of various screening strategies. SETTING: Two large obstetric units in the UK. PARTICIPANTS: Women booked for delivery at the participating units other than those electing for a Caesarean delivery. INTERVENTIONS: Vaginal and rectal swabs were obtained at the onset of labour and the results of vaginal and rectal PCR and OIA (index) tests were compared with the reference standard of enriched culture of combined vaginal and rectal swabs. MAIN OUTCOME MEASURES: The accuracy of the index tests, the relative accuracies of tests on vaginal and rectal swabs and whether test accuracy varied according to the presence or absence of maternal risk factors. RESULTS: PCR was significantly more accurate than OIA for the detection of maternal GBS colonisation. Combined vaginal or rectal swab index tests were more sensitive than either test considered individually [combined swab sensitivity for PCR 84% (95% CI 79-88%); vaginal swab 58% (52-64%); rectal swab 71% (66-76%)]. The highest sensitivity for PCR came at the cost of lower specificity [combined specificity 87% (95% CI 85-89%); vaginal swab 92% (90-94%); rectal swab 92% (90-93%)]. The sensitivity and specificity of rapid tests varied according to the presence or absence of maternal risk factors, but not consistently. PCR results were determinants of neonatal GBS colonisation, but maternal risk factors were not. Overall levels of acceptability for rapid testing amongst participants were high. Vaginal swabs were more acceptable than rectal swabs. South Asian women were least likely to have participated in the study and were less happy with the sampling procedure and with the prospect of rapid testing as part of routine care. Midwives were generally positive towards rapid testing but had concerns that it might lead to overtreatment and unnecessary interference in births. Modelling analysis revealed that the most cost-effective strategy was to provide routine intravenous antibiotic prophylaxis (IAP) to all women without screening. Removing this strategy, which is unlikely to be acceptable to most women and midwives, resulted in screening, based on a culture test at 35-37 weeks' gestation, with the provision of antibiotics to all women who screened positive being most cost-effective, assuming that all women in premature labour would receive IAP. The results were sensitive to very small increases in costs and changes in other assumptions. Screening using a rapid test was not cost-effective based on its current sensitivity, specificity and cost. CONCLUSIONS: Neither rapid test was sufficiently accurate to recommend it for routine use in clinical practice. IAP directed by screening with enriched culture at 35-37 weeks' gestation is likely to be the most acceptable cost-effective strategy, although it is premature to suggest the implementation of this strategy at present.
Resumo:
Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.
Resumo:
Areas covered: The review discusses the main challenges of ODT manufacturing process and the emerging solutions featured at early drug development stages. The research specifically describes the methods reported for taste masking/assessment and solubilisation of unpalatable and poorly soluble drugs, respectively. Furthermore, this review highlights the techniques used for developing modified-release ODTs, an emerging area in the field. In addition, it also discusses the poor flowability and segregation problems of directly compressed powders. Moreover, the review describes the tests reported in the literature for ODT disintegration time assessment since a universal technique is still non-existent. Expert opinion: The approaches used to overcome the manufacturing challenges often have a bearing on the price of the end product. However, despite the technical and regulatory challenges, ODTs can offer many advantages over the conventional dosage forms if accompanied by suitable adjuvant technologies and in vitro analytical tools. © 2014 Informa UK, Ltd. Introduction: Orally disintegrating tablets (ODTs) provide several advantages over conventional tablets such as suitability for patients with swallowing difficulties and faster onset of action. The manufacture of ODTs by compression/tableting offers a practical and cost-effective strategy over the freeze drying (lyophilisation) method. Nonetheless, the FDA recommends a disintegration time of 30 s and a maximum weight of 500 mg for a tablet to be labelled as an ODT. These requirements, alongside other desirable product properties, have created a number of challenges for the formulator to overcome while developing compressed ODTs.
Resumo:
Orimulsion400 is a new generation of the Orimulsion formula. This new generation is a more environmentally friendly, cost-effective energy source. This article describes the product's evolution as well as test results from diverse power plants.
Resumo:
For the development of communication systems such as Internet of Things, integrating communication with power supplies is an attractive solution to reduce supply cost. This paper presents a novel method of power/signal dual modulation (PSDM), by which signal transmission is integrated with power conversion. This method takes advantage of the intrinsic ripple initiated in switch mode power supplies as signal carriers, by which cost-effective communications can be realized. The principles of PSDM are discussed, and two basic dual modulation methods (specifically PWM/FSK and PWM/PSK) are concluded. The key points of designing a PWM/FSK system, including topology selection, carrier shape, and carrier frequency, are discussed to provide theoretical guidelines. A practical signal modulation-demodulation method is given, and a prototype system provides experimental results to verify the effectiveness of the proposed solution.
Resumo:
Accurate colour vision testing requires using the correct illumination. With the plethora of 'daylight' lamps available, is there a cost-effective alternative to the discontinued MacBeth Easel lamp? Smoking is a known risk factor for macula degeneration. As the macula is responsible for colour discrimination, any toxin that affects it has the potential to influence colour discrimination. Aims: To find a costeffective light source for colour vision testing. To investigate the effect of smoking on colour discrimination. To explore how deuteranomalous trichromats compare with normal trichromats. Methods: Using the Ishihara colour vision test subjects were classified into the groups: 'Normal/Control', 'Smoker/Test', and 'Case Study' (subjects who failed the screening test and did not smoke). They completed the Farnsworth Munsell 100 Hue test under each of the three light sources: Phillips EcoHalo Twist (tungsten halogen - THL), Kosnic KCF07ALU/GU10-865 (compact fluorescent- CFL), and Deal Guardian Ltd. GU103X2WA4B-60 (light-emitting diode - LED) Results: 42 subjects took part in the study: 18 in the Normal/Control group, 18 in the Smoker/Test group, and 6 in the Case Study group. For the Normal/Control group the total error scores (TESs) were significantly lower with the CFL than with the THL (p = 0.017) as it was for the Case Study group (p = 0.009). No significant differences were found between the Normal/Control group and the Smoker/Test group for each light source. Decision tree analysis found pack years to be a significant variable for TES. Discussion: All three light sources were comparable with previous studies. The CFL provided better colour discrimination than the LED despite them both being 6500 K. Deuteranomalous trichromats showed a greatest deviation than normal trichromats using the LED. Conclusions: The Kosnic KCF07ALU/GU10-865 is a cost-effective alternative for colour vision testing. Smoking appears to have an effect on colour vision, but requires further investigation.