903 resultados para Coronary Sinus


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Falls and fractures in the elderly are among the leading causes of disability. We investigated whether pacemaker implantation prevents falls in patients with SND in a large cohort of patients. Methods. Patient demographics and medical history were collected prospectively. Fall history was retrospectively reconstituted from available medical records. The 10-year probability for major osteoporotic fractures was calculated retrospectively from available medical records using the Swiss fracture risk assessment tool FRAX-Switzerland. Results. During a mean observation period of 2.3 years after implantation, the rates of fallers and injured fallers with fracture were reduced to 15% and 6%, respectively. This corresponds to a relative reduction in the number of fallers of 75% (P < 0.001) and of injured fallers of 63% (P = 0.014) after pacemaker implantation. Similarly, the number of falls was reduced from 60 (48%) before pacemaker implantation to 22 (18%) thereafter (relative reduction 63%, P = 0.035) and the number of falls with injury from 22 (18%) to 7 (6%), which corresponds to a relative reduction of 67%, P = 0.013. Conclusion. In patients with SND, pacemaker implantation significantly reduces the number of patients experiencing falls, the total number of falls, and the risk for osteoporotic fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Guidelines for the prevention of coronary heart disease (CHD) recommend use of Framingham-based risk scores that were developed in white middle-aged populations. It remains unclear whether and how CHD risk prediction might be improved among older adults. We aimed to compare the prognostic performance of the Framingham risk score (FRS), directly and after recalibration, with refit functions derived from the present cohort, as well as to assess the utility of adding other routinely available risk parameters to FRS. Methods Among 2193 black and white older adults (mean age, 73.5 years) without pre-existing cardiovascular disease from the Health ABC cohort, we examined adjudicated CHD events, defined as incident myocardial infarction, CHD death, and hospitalization for angina or coronary revascularization. Results During 8-year follow-up, 351 participants experienced CHD events. The FRS poorly discriminated between persons who experienced CHD events vs. not (C-index: 0.577 in women; 0.583 in men) and underestimated absolute risk prediction by 51% in women and 8% in men. Recalibration of the FRS improved absolute risk prediction, particulary for women. For both genders, refitting these functions substantially improved absolute risk prediction, with similar discrimination to the FRS. Results did not differ between whites and blacks. The addition of lifestyle variables, waist circumference and creatinine did not improve risk prediction beyond risk factors of the FRS. Conclusions The FRS underestimates CHD risk in older adults, particularly in women, although traditional risk factors remain the best predictors of CHD. Re-estimated risk functions using these factors improve accurate estimation of absolute risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Noninvasive stress testing might guide the use of aspirin and statins for primary prevention of coronary heart disease, but it is unclear if such a strategy would be cost effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A first case of coronary stent implantation through a 4 French diagnostic catheter is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SYNTAX score (SXscore), an anatomical-based scoring tool reflecting the complexity of coronary anatomy, has established itself as an important long-term prognostic factor in patients undergoing percutaneous coronary intervention (PCI). The incorporation of clinical factors may further augment the utility of the SXscore to longer-term risk stratify the individual patient for clinical outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prognostic relevance of quantitative an intracoronary occlusive electrocardiographic (ECG) ST-segment shift and its determinants have not been investigated in humans. In 765 patients with chronic stable coronary artery disease, the following simultaneous quantitative measurements were obtained during a 1-minute coronary balloon occlusion: intracoronary ECG ST-segment shift (recorded by angioplasty guidewire), mean aortic pressure, mean distal coronary pressure, and mean central venous pressure (CVP). Collateral flow index (CFI) was calculated as follows: (mean distal coronary pressure minus CVP)/(mean aortic pressure minus CVP). During an average follow-up duration of 50 ± 34 months, the cumulative mortality rate from all causes was significantly lower in the group with an ST-segment shift <0.1 mV (n = 89) than in the group with an ST-segment shift ≥0.1 mV (n = 676, p = 0.0211). Factors independently related to intracoronary occlusive ECG ST-segment shift <0.1 mV (r(2) = 0.189, p <0.0001) were high CFI (p <0.0001), intracoronary occlusive RR interval (p = 0.0467), right coronary artery as the ischemic region (p <0.0001), and absence of arterial hypertension (p = 0.0132). "High" CFI according to receiver operating characteristics analysis was ≥0.217 (area under receiver operating characteristics curve 0.647, p <0.0001). In conclusion, absence of ECG ST-segment shift during brief coronary occlusion in patients with chronic coronary artery disease conveys a decreased mortality and is directly influenced by a well-developed collateral supply to the right versus left coronary ischemic region and by the absence of systemic hypertension in a patient's history.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In most patients with chronic heart failure (CHF), endurance training improves exercise capacity. However, some patients do not respond favourably. The purpose of this study was to explore the reasons of non-response and to determine their predictive value.Methods: We studied a cohort of 120 consecutive CHF patients with sinus rhythm (mean age 57 ± 12 years, ejection fraction 29.3 ± 9.9%, peak VO2 17.3 ± 5.1 ml/min/kg), participating in a 3-month outpatient cardiac rehabilitation programme. Responders were defined as subjects who improved peak VO2 by more than 5%, work load by more than 10%, or VE/VCO2 slope by more than 5%. Subjects who did not fulfil at least one of the above criteria were characterized as non-responders. Multivariate regression analyses were performed to identify parameters that were predictive for a response. Receiver operating characteristic (ROC) analyses were performed for predictive parameters to identify thresholds for response or non-response.Results: Multivariate regression analyses revealed heart rate (HR) reserve, HR recovery at 1 min, and peak HR as significant predictors for a positive training response. ROC curves revealed the optimal thresholds separating responders from non-responders at less than 30 bpm for HR reserve, less than 6 bpm for HR recovery and less than 101 bpm for peak HR.Conclusions: The presence of impaired chronotropic competence is a major predictor of poor training response in CHF patients with sinus rhythm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefit of the coronary collateral circulation (natural bypass network) on survival is well established. However, data derived from smaller studies indicates that coronary collaterals may increase the risk for restenosis after percutaneous coronary interventions. The purpose of this systematic review and meta-analysis of observational studies was to explore the impact of the collateral circulation on the risk for restenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prompt reperfusion with primary percutaneous coronary intervention represents the current gold standard treatment for patients with acute myocardial infarction. In this setting, coronary stents have been shown to improve outcomes compared to plain angioplasty and are routinely used. However, the stent selection among patients with acute myocardial infarction is still a matter of some debate. An increased risk of very late (>1-year) stent thrombosis has been associated with the use of early-generation drug-eluting stents (DES), leading to concerns regarding the long-term safety of these devices. Newer-generation DES were developed with the aim of addressing this safety issue, and were recently investigated in a few randomized studies in patients with acute myocardial infarction. The objective of the present review is to summarize the accumulated evidence, to guide the stent selection in patients with acute myocardial infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Globalisation in coronary stent research calls for harmonization of clinical endpoint definitions and event adjudication. Little has been published about the various processes used for event adjudication or their impact on outcome reporting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SPIRIT Women is the first interventional trial dedicated exclusively to women, focusing on symptoms at presentation, referral time to coronary intervention and the safety and performance of the XIENCE V stent.