985 resultados para Composite Measurement Scales
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2011
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2014
Resumo:
n.s. no.36(1987)
Resumo:
n.s. no.56(1990)
Resumo:
Amphisbaena nigricauda Gans, 1966 is a small, poorly known amphisbaenid endemic to the restinga of the states of Espírito Santo and Bahia, Brazil. We analyze 178 specimens collected in Vitória municipality, state of Espírito Santo, Brazil, to investigate whether this species show sexual dimorphism in pre-cloacal pores and in morphological characters. Sex was determined by a ventral incision and direct inspection of gonads. A PCA analysis was performed to generate a general body size measurement. A T test and the non-parametric Mann-Whitney test were used to assess whether this species show sexual dimorphism on five morphometric and five meristic characters, respectively. Sex could not be determined in 36 specimens because they were mutilated in the posterior portion of their bodies. The diagnosis of the species is redefined based on this sample size: the smallest number of body annuli changes from 222 to 192, the number of dorsal and ventral segments in an annulus in the middle of the body changes to 9-11/13-16 (instead of 10/16), and the autotomic tail annulus lies between annulus 7-10 (instead of 6-9). The number of tail annuli remained within the known range of variation of the species (19-24). None of the 80 females analyzed showed pre-cloacal pores, whereas within males 59 out of 62 specimens displayed four and two specimens displayed five pre-cloacal pores. A single male did not possess pre-cloacal pores, but showed irregular scales on its cloacal region. Sex-based difference based on presence or absence of pre-cloacal pores as well as males with wider head was seen in other Neotropical amphisbaenids. However, a pattern of body size differences between males and females has not been identified so far in the few amphisbaenid species studied in this regard. Further studies on this taxonomic group are still needed to elucidate the existence of general patterns of sexual dimorphism and to identify the selective pressures driving these patterns.
Resumo:
This paper develops the link between poverty and inequality by focussing on a class of poverty indices (some of them well-known) which aggregate normative concerns for absolute and relative deprivation. The indices are distinguished by a parameter that captures the ethical sensitivity of poverty measurement to ``exclusion'' or ``relative-deprivation'' aversion. We also show how the indices can be readily used to predict the impact of growth on poverty. An illustration using LIS data finds that he United States show more relative deprivation than Denmark and Belgium whatever the percentiles considered, but that overall deprivation comparisons of the four countries considered will generally necessarily depend on the intensity of the ethical concern for relative deprivation. The impact of growth on poverty is also seen to depend on the presence of and on the attention granted to concerns over relative deprivation. }
Resumo:
In this paper well-known summary inequality indexes are used to explore interregional income inequalities in Europe. In particular, we mainly employ Theilspopulation-weighted index because of its appealing properties. Two decomposition analysis are applied. First, regional inequalities are decomposed by regional subgroups (countries). Second, intertemporal inequality changes are separated into income and population changes. The main results can be summarized as follows. First, data confirm a reduction in crossregional inequality during 1982-97. Second, this reduction is basically due to real convergence among countries. Third, currently the greater part of European interregional disparities is within-country by nature, which introduce an important challenge for the European policy. Fourth, inequality changes are due mainly to income variations, population changes playing a minor role.
Resumo:
Estudi elaborat a partir d’una estada a l’ Imperial College London, entre juliol i novembre de 2006. En aquest treball s’ha investigat la geometria més apropiada per a la caracterització de la tenacitat a fractura intralaminar de materials compòsits laminats amb teixit. L’objectiu és assegurar la propagació de l’esquerda sense que la proveta falli abans per cap altre mecanisme de dany per tal de permetre la caracterització experimental de la tenacitat a fractura intralaminar de materials compòsits laminats amb teixit. Amb aquesta fi, s’ha dut a terme l’anàlisi paramètrica de diferents tipus de provetes mitjançant el mètode dels elements finits (FE) combinat amb la virtual crack closure technique (VCCT). Les geometries de les provetes analitzades corresponen a la proveta de l’assaig compact tension (CT) i diferents variacions com la extended compact tension (ECT), la proveta widened compact tension (WCT), tapered compact tension (TCT) i doubly-tapered compact tension (2TCT). Com a resultat d’aquestes anàlisis s’han derivat diferents conclusions per obtenir la geometria de proveta més apropiada per a la caracterització de la tenacitat a fractura intralaminar de materials compòsits laminats amb teixit. A més, també s’han dut a terme una sèrie d’assaigs experimentals per tal de validar els resultats de les anàlisis paramètriques. La concordança trobada entre els resultats numèrics i experimentals és bona tot i la presència d’efectes no previstos durant els assaigs experimentals.
Resumo:
PURPOSE: To evaluate a diagnostic strategy for pulmonary embolism that combined clinical assessment, plasma D-dimer measurement, lower limb venous ultrasonography, and helical computed tomography (CT). METHODS: A cohort of 965 consecutive patients presenting to the emergency departments of three general and teaching hospitals with clinically suspected pulmonary embolism underwent sequential noninvasive testing. Clinical probability was assessed by a prediction rule combined with implicit judgment. All patients were followed for 3 months. RESULTS: A normal D-dimer level (<500 microg/L by a rapid enzyme-linked immunosorbent assay) ruled out venous thromboembolism in 280 patients (29%), and finding a deep vein thrombosis by ultrasonography established the diagnosis in 92 patients (9.5%). Helical CT was required in only 593 patients (61%) and showed pulmonary embolism in 124 patients (12.8%). Pulmonary embolism was considered ruled out in the 450 patients (46.6%) with a negative ultrasound and CT scan and a low-to-intermediate clinical probability. The 8 patients with a negative ultrasound and CT scan despite a high clinical probability proceeded to pulmonary angiography (positive: 2; negative: 6). Helical CT was inconclusive in 11 patients (pulmonary embolism: 4; no pulmonary embolism: 7). The overall prevalence of pulmonary embolism was 23%. Patients classified as not having pulmonary embolism were not anticoagulated during follow-up and had a 3-month thromboembolic risk of 1.0% (95% confidence interval: 0.5% to 2.1%). CONCLUSION: A noninvasive diagnostic strategy combining clinical assessment, D-dimer measurement, ultrasonography, and helical CT yielded a diagnosis in 99% of outpatients suspected of pulmonary embolism, and appeared to be safe, provided that CT was combined with ultrasonography to rule out the disease.
Resumo:
Polarization indices presented up to now have only focused their attention on the distribution of income/wealth. However, in many circumstances income is not the only relevant dimension that might be the cause of social conflict, so it is very important to have a social polarization index able to cope with alternative dimensions. In this paper we present an axiomatic characterization of one of such indices: it has been obtained as an extension of the (income) polarization measure introduced in Duclos, Esteban and Ray (2004) to a wider domain. It turns out that the axiomatic structure introduced in that paper alone is not appropriate to obtain a fully satisfactory characterization of our measure, so additional axioms are proposed. As a byproduct, we present an alternative axiomatization of the aforementioned income polarization measure.
Resumo:
Introduction: Several scores are commonly used to evaluate patients' postoperative satisfaction after lateral ankle ligament repair, including: AOFAS, FAAM, CAIT and CAIS. Comparing published studies in the literature is difficult, as the same patient can have markedly different results depending on which scoring system is used. The current study aims to address this gap in the literature by developing a system to compare these tests, to allow better analysis and comparison of published studies. Patients and methods: This is a retrospective cohort study of 47 patients following lateral ankle ligament repair using a modified Broström-Gould technique. All patients were operated between 2005 and 2010 by a single surgeon and followed the same post operative rehabilitation protocol. Six patients were excluded from the study because of concomitant surgery. Patients were assessed by an independent observer. We used the Pearson correlation coefficient to analyse the concordance of the scores, as well as scatter plots to assess the linear relationship between them. Results: A linear distribution between the scores was found when the results were analysed using scatter plots. We were thus able to use the Pearson correlation coefficient to evaluate the relationship between each of the different postoperative scores. The correlation was found to be above 0.5 in all cases except for the comparison between the CAIT and the FAAM for the activities of daily living (0.39). We were, therefore, able to compare the results obtained and assess the relative concordance of the scoring systems. The results showed that the more specific the scale is, the worst the score is and inversely. So the CAIT and the CAIS appeared to be more severe than the AOFAS and the FAAM measuring the activities of daily living. The sports subscale of the FAAM demonstrated intermediate results. Conclusion: This study outlines a system to compare different postoperative scores commonly used to evaluate outcome after ankle stabilization surgery. The impact of this study is that it makes comparison of published studies easier, even though they use a variety of different clinical scores, thus facilitating better outcome analysis of operative techniques.
Resumo:
D53 (RibomuntyR) is a composite vaccine made of immunogenic ribosomes from 4 bacterial species (Klebsiella pneumoniae, Haemophilus influenzae, Streptococcus pyogenes and Streptococcus pneumoniae) associated with a membrane proteoglycan from a non encapsulated strain of Klebsiella pneumoniae. D53 is a potent inducer of interleukin-1 production by mouse BALB/c spleen cells as shown by the C3H/HeJ thymocyte co-stimulation assay. Furthermore D53 triggers DNA synthesis by mouse spleen cells and induces the maturation of B lymphocytes into immunoglobulin secreting cells. Polyclonal B cell activation by D53 was readily achieved in the C3H/HeJ strain which is deficient in its response to E. coli lipopolysaccharide. The proliferative response to D53 was abrogated by removal of B cells from the spleen cell suspension, but it was not altered after depletion of T cells or adherent cells. D53 induced polyclonal B cell activation of spleen cells from athymic nude mice and from CBA/N mice. Each component of D53 induced polyclona B cell activation except ribosomes from Streptococcus pneumoniae. Each triggered Interleukin-1 synthesis except ribosomes from Klebsiella penumoniae. These in vitro properties may account for some of the in vivo immunostimulating properties of this composite vaccine.
Resumo:
The traditional basis for assessing the effect of antihypertensive therapy is the blood pressure reading taken by a physician. However, several recent trials have been designed to evaluate the blood pressure lowering effect of various therapeutic agents during the patients' normal daytime activities, using a portable, semi-automatic blood pressure recorder. The results have shown that in a given patient, blood pressure measured at the physician's office often differs greatly from that prevailing during the rest of the day. This is true both in treated and untreated hypertensive patients. The difference between office and ambulatory recorded pressures cannot be predicted from blood pressure levels measured by the physician. Therefore, a prospective study was carried out in patients with diastolic blood pressures that were uncontrolled at the physician's office despite antihypertensive therapy. The purpose was to evaluate the response of recorded ambulatory blood pressure to treatment adjustments aimed at reducing office blood pressure below a pre-set target level. Only patients with high ambulatory blood pressures at the outset appeared to benefit from further changes in therapy. Thus, ambulatory blood pressure monitoring can be used to identify those patients who remain hypertensive only when facing the physician, despite antihypertensive therapy. Ambulatory monitoring could thus help to evaluate the efficacy of antihypertensive therapy and allow individual treatment.
Resumo:
We propose a new method, based on inertial sensors, to automatically measure at high frequency the durations of the main phases of ski jumping (i.e. take-off release, take-off, and early flight). The kinematics of the ski jumping movement were recorded by four inertial sensors, attached to the thigh and shank of junior athletes, for 40 jumps performed during indoor conditions and 36 jumps in field conditions. An algorithm was designed to detect temporal events from the recorded signals and to estimate the duration of each phase. These durations were evaluated against a reference camera-based motion capture system and by trainers conducting video observations. The precision for the take-off release and take-off durations (indoor < 39 ms, outdoor = 27 ms) can be considered technically valid for performance assessment. The errors for early flight duration (indoor = 22 ms, outdoor = 119 ms) were comparable to the trainers' variability and should be interpreted with caution. No significant changes in the error were noted between indoor and outdoor conditions, and individual jumping technique did not influence the error of take-off release and take-off. Therefore, the proposed system can provide valuable information for performance evaluation of ski jumpers during training sessions.