939 resultados para Cd
Resumo:
Thesis (doctoral)--Friedrich-Alexanders-Universitat Erlangen.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
We present a catalogue of galaxies in Abell 3653 from observations made with the 2-degree field (2dF) spectrograph at the Anglo-Australian Telescope. Of the 391 objects observed, we find 111 are bona fide members of Abell 3653. We show that the cluster has a velocity of cz= 32 214 +/- 83 km s(-1) (z= 0.10 738 +/- 0.00 027), with a velocity dispersion typical of rich, massive clusters of sigma(cz)= 880(-54)(+66). We find that the cD galaxy has a peculiar velocity of 683 +/- 96 km s(-1) in the cluster rest frame - some 7 sigma away from the mean cluster velocity, making it one of the largest and most significant peculiar velocities found for a cD galaxy to date. We investigate the cluster for signs of substructure, but do not find any significant groupings on any length scale. We consider the implications of our findings on cD formation theories.
Resumo:
Produced water is a major problem associated with the crude oil extraction activity. The monitoring of the levels of metals in the waste is constant and requires the use of sensitive analytical techniques. However, the determination of trace elements can often require a pre-concentration step. The objective of this study was to develop a simple and rapid analytical method for the extraction and pre-concentration based on extraction phenomenon cloud point for the determination of Cd, Pb and Tl in produced water samples by spectrometry of high resolution Absorption source continues and atomization graphite furnace. The Box Behnken design was used to obtain the optimal condition of extraction of analytes. The factors were evaluated: concentration of complexing agent (o,o-dietilditilfosfato ammonium, DDTP), the concentration of hydrochloric acid and concentration of surfactant (Triton X -114). The optimal condition obtained through extraction was: 0,6% m v-1 DDTP, HCl 0,3 mol L-1 and 0,2% m v-1 of Triton X - 114 for Pb; 0,7% m v-1 DDTP, HCl 0,8 mol L-1 and 0,2% m v-1 Triton X-114 for Cd. For Tl was evidenced that best extraction condition occurs with no DDTP, the extraction conditions were HCl 1,0 mol L-1 e 1,0% m v-1 de Triton X - 114. The limits of detection for the proposed method were 0,005 µg L-1 , 0,03 µg L-1 and 0,09 µg L-1 to Cd, Pb and Tl, Respectively. Enrichment factors Were greater than 10 times. The method was applied to the water produced in the Potiguar basin, and addition and recovery tests were performed, and values were between 81% and 120%. The precision was expressed with relative standard deviation (RSD) is less than 5%
Resumo:
The determination and monitoring of metallic contaminants in water is a task that must be continuous, leading to the importance of the development, modification and optimization of analytical methodologies capab le of determining the various metal contaminants in natural environments, because, in many cases, the ava ilable instrumentation does not provide enough sensibility for the determination of trace values . In this study, a method of extraction and pre- concentration using a microemulsion system with in the Winsor II equilibrium was tested and optimized for the determination of Co, Cd, P b, Tl, Cu and Ni through the technique of high- resolution atomic absorption spectrometry using a continuum source (HR-CS AAS). The optimization of the temperature program for the graphite furnace (HR-CS AAS GF) was performed through the pyrolysis and atomization curves for the analytes Cd, Pb, Co and Tl with and without the use of different chemical modifiers. Cu and Ni we re analyzed by flame atomization (HR-CS F AAS) after pre-concentr ation, having the sample introduction system optimized for the realization of discrete sampling. Salinity and pH levels were also analyzed as influencing factors in the efficiency of the extraction. As final numbers, 6 g L -1 of Na (as NaCl) and 1% of HNO 3 (v/v) were defined. For the determination of the optimum extraction point, a centroid-simplex statistical plan was a pplied, having chosen as the optimum points of extraction for all of the analytes, the follo wing proportions: 70% aqueous phase, 10% oil phase and 20% co-surfactant/surfactant (C/S = 4). After extraction, the metals were determined and the merit figures obtained for the proposed method were: LOD 0,09, 0,01, 0,06, 0,05, 0,6 and 1,5 μg L -1 for Pb, Cd, Tl, Co, Cu and Ni, re spectively. Line ar ranges of ,1- 2,0 μg L -1 for Pb, 0,01-2,0 μg L -1 for Cd, 1,0 - 20 μg L -1 for Tl, 0,1-5,0 μg L -1 for Co, 2-200 μg L -1 and for Cu e Ni 5-200 μg L -1 were obtained. The enrichment factors obtained ranged between 6 and 19. Recovery testing with the certified sample show ed recovery values (n = 3, certified values) after extraction of 105 and 101, 100 and 104% for Pb, Cd, Cu and Ni respectively. Samples of sweet waters of lake Jiqui, saline water from Potengi river and water produced from the oil industry (PETROBRAS) were spiked and the recovery (n = 3) for the analytes were between 80 and 112% confirming th at the proposed method can be used in the extraction. The proposed method enabled the sepa ration of metals from complex matrices, and with good pre-concentration factor, consistent with the MPV (allowed limits) compared to CONAMA Resolution No. 357/2005 which regulat es the quality of fresh surface water, brackish and saline water in Brazil.
Resumo:
Objectives To evaluate the change in masticatory efficiency and quality of life of patients treated with mandibular Kennedy class I removable partial dentures (RPDs) and maxillary complete dentures at the Department of Dentistry of the Federal University of Rio Grande do Norte. Materials and methods A total of 33 Kennedy class I patients were rehabilitated with maxillary complete dentures, and mandibular RPDs were selected for this non-randomized prospective intervention study. The patients had a mean age of 59.1 years. Masticatory efficiency was evaluated by colorimetric assay using fuchsin capsules. The measurements were conducted at baseline and 2 and 6 months after prosthesis insertion. Quality of life was evaluated using the Oral Health Impact Profile (OHIP-14) at baseline and 6 months after denture insertion. The Kolmogorov-Smirnov normality test was applied. Masticatory efficiency was evaluated by repeated measures ANOVA. Oral health-related quality of life was compared using the paired t test. Results There was no statistically significant difference in masticatory efficiency after denture insertion (p = 0.101). Significant differences were found (p = 0.010) for oral health-related quality of life. A significant improvement in psychological discomfort (p < 0.01) and psychological disability (p < 0.01) was observed. Mean difference value (95 % confidence interval) was 6.8 (3.8 to 9.7) points, reflecting a low impact of oral health on quality of life, considering the 0–56 range of variation of the OHIP-14 and a Cohen’s d of 1.13. Conclusion According to the results of the present study, rehabilitation with Kennedy class I RPDs and complete dentures did not influence masticatory efficiency but improved oral health-related quality of life. Clinical relevance The association between the patient’s quality of life and the masticatory efficiency is important for treatment predictability.