998 resultados para COLUMN-SWITCHING TECHNIQUE
Resumo:
In this work, using the EPR spectroscopy, we analysed the thermal stability of some organic-mineral compounds found in a Gleysoil from Rio Janeiro. It was observed a complete disappearance of the EPR signal around 600 °C for the < 2 µm fraction and a residual EPR signal of semiquinone free radical for the 2-20 µm and 20-53 µm fractions at the same temperature. Also, the experiments showed that the 2-20 µm fraction had a larger concentration of semiquinone free radical per g of carbon and a smaller line width indicated a larger humification of this fraction. This is an evidence that the soil organic matter of this fraction (2-20 µm) is more stable than the other ones.
Resumo:
Ethernet is becoming the dominant aggregation technology for carrier transport networks; however, as it is a LAN technology, native bridged ethernet does not fulfill all the carrier requirements. One of the schemes proposed by the research community to make ethernet fulfill carrier requirements is ethernet VLAN-label switching (ELS). ELS allows the creation of label switched data paths using a 12-bit label encoded in the VLAN TAG control information field. Previous label switching technologies such as MPLS use more bits for encoding the label. Hence, they do not suffer from label sparsity issues as ELS might. This paper studies the sparsity issues resulting from the reduced ELS VLAN-label space and proposes the use of the label merging technique to improve label space usage. Experimental results show that label merging considerably improves label space usage
Resumo:
Several studies have suggested a bilingual advantage in executive functions, presumably due to bilinguals' massive practice with language switching that requires executive resources, but the results are still somewhat controversial. Previous studies are also plagued by the inherent limitations of a natural groups design where the participant groups are bound to differ in many ways in addition to the variable used to classify them. In an attempt to introduce a complementary analysis approach, we employed multiple regression to study whether the performance of 30- to 75-year-old FinnishSwedish bilinguals (N = 38) on tasks measuring different executive functions (inhibition, updating, and set shifting) could be predicted by the frequency of language switches in everyday life (as measured by a language switching questionnaire), L2 age of acquisition, or by the self-estimated degree of use of both languages in everyday life. Most consistent effects were found for the set shifting task where a higher rate of everyday language switches was related to a smaller mixing cost in errors. Mixing cost is thought to reflect top-down management of competing task sets, thus resembling the bilingual situation where decisions of which language to use has to be made in each conversation. These findings provide additional support to the idea that some executive functions in bilinguals are affected by a lifelong experience in language switching and, perhaps even more importantly, suggest a complementary approach to the study of this issue.
Resumo:
Language switching is omnipresent in bilingual individuals. In fact, the ability to switch languages (code switching) is a very fast, efficient, and flexible process that seems to be a fundamental aspect of bilingual language processing. In this study, we aimed to characterize psychometrically self-perceived individual differences in language switching and to create a reliable measure of this behavioral pattern by introducing a bilingual switching questionnaire. As a working hypothesis based on the previous literature about code switching, we decomposed language switching into four constructs: (i) L1 switching tendencies (the tendency to switch to L1; L1-switch); (ii) L2 switching tendencies (L2-switch); (iii) contextual switch, which indexes the frequency of switches usually triggered by a particular situation, topic, or environment; and (iv) unintended switch, which measures the lack of intention and awareness of the language switches. A total of 582 SpanishCatalan bilingual university students were studied. Twelve items were selected (three for each construct). The correlation matrix was factor-analyzed using minimum rank factor analysis followed by oblique direct oblimin rotation. The overall proportion of common variance explained by the four extracted factors was 0.86. Finally, to assess the external validity of the individual differences scored with the new questionnaire, we evaluated the correlations between these measures and several psychometric (language proficiency) and behavioral measures related to cognitive and attentional control. The present study highlights the importance of evaluating individual differences in language switching using self-assessment instruments when studying the interface between cognitive control and bilingualism.
Resumo:
A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.
Resumo:
The first two papers in this series described the basic theory involved in supercritical fluid chromatography (SFC), how the technique evolved from gas and liquid chromatography and how the instrumentation was developed. Over the last two years, a commercial, dedicated packed-column SFC/MS instrument appeared on the market. The SFC continues to grow in use, with fundamental developments, coupled with a steady rise in the number of industrial users and applications.
Resumo:
BACKGROUND: With many atypical antipsychotics now available in the market, it has become a common clinical practice to switch between atypical agents as a means of achieving the best clinical outcomes. This study aimed to examine the impact of switching from olanzapine to risperidone and vice versa on clinical status and tolerability outcomes in outpatients with schizophrenia in a naturalistic setting. METHODS: W-SOHO was a 3-year observational study that involved over 17,000 outpatients with schizophrenia from 37 countries worldwide. The present post hoc study focused on the subgroup of patients who started taking olanzapine at baseline and subsequently made the first switch to risperidone (n=162) and vice versa (n=136). Clinical status was assessed at the visit when the first switch was made (i.e. before switching) and after switching. Logistic regression models examined the impact of medication switch on tolerability outcomes, and linear regression models assessed the association between medication switch and change in the Clinical Global Impression-Schizophrenia (CGI-SCH) overall score or change in weight. In addition, Kaplan-Meier survival curves and Cox-proportional hazards models were used to analyze the time to medication switch as well as time to relapse (symptom worsening as assessed by the CGI-SCH scale or hospitalization). RESULTS: 48% and 39% of patients switching to olanzapine and risperidone, respectively, remained on the medication without further switches (p=0.019). Patients switching to olanzapine were significantly less likely to experience relapse (hazard ratio: 3.43, 95% CI: 1.43, 8.26), extrapyramidal symptoms (odds ratio [OR]: 4.02, 95% CI: 1.49, 10.89) and amenorrhea/galactorrhea (OR: 8.99, 95% CI: 2.30, 35.13). No significant difference in weight change was, however, found between the two groups. While the CGI-SCH overall score improved in both groups after switching, there was a significantly greater change in those who switched to olanzapine (difference of 0.29 points, p=0.013). CONCLUSION: Our study showed that patients who switched from risperidone to olanzapine were likely to experience a more favorable treatment course than those who switched from olanzapine to risperidone. Given the nature of observational study design and small sample size, additional studies are warranted.
Resumo:
The design and use of a novel apparatus for a variant of vacuum distillation is described. Relative to a conventional device, the apparatus/technique described permits superior recovery of multigram quantities of moderately volatile liquids from vacuum distillations.
Resumo:
We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method.
Resumo:
Aim of this thesis was to design and manufacture a microdistillation column. The literature review part of this thesis covers stainless steels, material processing and basics about engineering design and distillation. The main focus, however, is on the experimental part. Experimental part is divided into five distinct sections: First part is where the device is introduced and separated into three parts. Secondly the device is designed part by part. It consists mostly of detail problem solving, since the first drawings had already been drawn and the critical dimensions decided. Third part is the manufacture, which was not fully completed since the final assembly was left out of this thesis. Fourth part is the test welding for the device, and its analysis. Finally some ideas for further studies are presented. The main goal of this thesis was accomplished. The device only lacks some final assembly but otherwise it is complete. One thing that became clear during the process was how difficult it is to produce small and precise steel parts with conventional manufacturing methods. Internal stresses within steel plates and thermal distortions can easily ruin small steel structures. Designing appropriate welding jigs is an important task for even simple devices. Laser material processing is a promising tool for this kind of steel processing because of the flexibility, good cutting quality and also precise and low heat input when welding. Next step in this project is the final assembly and the actual distillation tests. The tests will be carried out at Helsinki University of Technology.
Resumo:
This work was aimed on optimization of the matrix solid-phase dispersion (MSPD) technique using gas chromatography for analyzing residues of chlorpyriphos, λ-cyhalothrin, cypermethrin and deltamethrin in tomatoes. The results showed that silica was more efficient for the clean up of extracts, but florisil provided the highest recovery rates. A 2³ complete factorial design was carried out to evaluate the absorbent/sample ratio, presence of co-column (silica) and ultrasonic bath on the extraction rate. The percentage of extraction of the pesticides chlorpyriphos, λ-cyhalothrin, cypermethrin and deltamethrin were 64.7, 88.3, 99.2 and 89.2%, respectively, with relative standard deviations below 5%.
Resumo:
This paper presents the fundamental principles, instrumentation and selected applications of comprehensive two-dimensional gas chromatography (GC × GC). In this technique, introduced in 1991, two capillary columns are coupled and proper modulating interfaces continuously collect the eluate from the first column, transferring it to the second column. The result is a geometric increment in the chromatographic resolution, ensuring separation of extremely complex mixtures in time periods shorter or comparable to those of analysis using conventional gas chromatography and with better detectabilities and sensitivities.
Resumo:
Capillary electrochromatography (CEC) is a separation technique in which the mobile phase flow is based on the application of a voltage across a packed capillary, which generates an electroosmotic flow that transports the analytes along the capillary toward the detector. As it combines the separation mechanisms of high-performance liquid chromatography (HPLC) and of capillary electrophoresis (CE), CEC can be considered a hybrid of HPLC and CE. This review presents some fundamental aspects of CEC and is focused on the instrumental advances of the technique, such as column technology, operation modes and detection systems, presenting recent papers on these topics and some applications and perspectives about CEC.
Resumo:
Signal processing methods based on the combined use of the continuous wavelet transform (CWT) and zero-crossing technique were applied to the simultaneous spectrophotometric determination of perindopril (PER) and indapamide (IND) in tablets. These signal processing methods do not require any priory separation step. Initially, various wavelet families were tested to identify the optimum signal processing giving the best recovery results. From this procedure, the Haar and Biorthogonal1.5 continuous wavelet transform (HAAR-CWT and BIOR1.5-CWT, respectively) were found suitable for the analysis of the related compounds. After transformation of the absorbance vectors by using HAAR-CWT and BIOR1.5-CWT, the CWT-coefficients were drawn as a graph versus wavelength and then the HAAR-CWT and BIOR1.5-CWT spectra were obtained. Calibration graphs for PER and IND were obtained by measuring the CWT amplitudes at 231.1 and 291.0 nm in the HAAR-CWT spectra and at 228.5 and 246.8 nm in BIOR1.5-CWT spectra, respectively. In order to compare the performance of HAAR-CWT and BIOR1.5-CWT approaches, derivative spectrophotometric (DS) method and HPLC as comparison methods, were applied to the PER-IND samples. In this DS method, first derivative absorbance values at 221.6 for PER and 282.7 nm for IND were used to obtain the calibration graphs. The validation of the CWT and DS signal processing methods was carried out by using the recovery study and standard addition technique. In the following step, these methods were successfully applied to the commercial tablets containing PER and IND compounds and good accuracy and precision were reported for the experimental results obtained by all proposed signal processing methods.
Resumo:
Determination of free urinary cortisol is a test of choice in the diagnosis of Cushing's syndrome. In this study, cortisol was quantified using reversed-phase high-performance liquid chromatography (RP-HPLC) in urine samples previously extracted with ether and using triamcinolone acetonide as internal standard (IS). A BDS-Hypersil-C18® column, water-acetonitrile (72:28; v/v), with a flow rate of 1.0 mL/min and detection at 243 nm were used. This method showed to be both effective and efficient, with sensitivity and linearity ranging from 2.50 to 150 μg/L, and can be used in substitution to the radioimmunoassay technique within this concentration range.