895 resultados para Blood plasma.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Most studies reporting evidence of adverse effects of lead and cadmium on the ability to balance have been conducted in high-exposure groups or have included adults. The effects of prenatal exposure have not been well studied, nor have the effects in children been directly studied. The aim of the study was to identify the associations of lead (in utero and in childhood) and cadmium (in utero) exposure with the ability to balance in children aged 7 and 10 years. DESIGN: Prospective birth cohort study. PARTICIPANTS: Maternal blood lead (n=4285) and cadmium (n=4286) levels were measured by inductively coupled plasma mass spectrometry in women enrolled in the Avon Longitudinal Study of Parents and Children (ALSPAC) during pregnancy. Child lead levels were measured in a subsample of 582 of ALSPAC children at age 30 months. MAIN OUTCOME MEASURES: Children completed a heel-to-toe walking test at 7 years. At 10 years, the children underwent clinical tests of static and dynamic balance. Statistical analysis using SPSS V.19 included logistic regression modelling, comparing categories of ≥ 5 vs <5 µg/dL for lead, and ≥ 1 vs <1 µg/L for cadmium. RESULTS: Balance at age 7 years was not associated with elevated in utero lead or cadmium exposure (adjusted OR for balance dysfunction: Pb 1.01 (95% CI 0.95 to 1.01), n=1732; Cd 0.95 (0.77 to 1.20), n=1734), or with elevated child blood lead level at age 30 months (adjusted OR 0.98 (0.92 to 1.05), n=354). Similarly, neither measures of static nor dynamic balance at age 10 years were associated with in utero lead or cadmium exposure, or child lead level. CONCLUSIONS: These findings do not provide any evidence of an association of prenatal exposure to lead or cadmium, or lead levels in childhood, on balance ability in children. Confirmation in other cohorts is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The shortage of donor hearts for patients with end stage heart failure has accelerated the development of ventricular assist devices (VAD) that act as a replacement heart. Mechanical devices involving pulsatile, axial and centrifugal devices have been proposed. Recent clinical developments indicate that centrifugal devices are not only beneficial for bridge to transplantation applications, but may also aid myocardial recovery. The results of a recent study have shown that patients who received a VAD have extended lives and improved quality of life compared to recipients of drug therapy. Unfortunately 25% of these patients develop right heart failure syndrome, sepsis and multi-organ failure. It was reported that 17% of patients initially receiving an LVAD later required a right ventricular assist device (RVAD). Hence, current research focus is in the development of a bi-ventricular assist device (BVAD). Current BVAD technology is either too bulky or necessitates having to implant two pumps working independently. The latter requires two different controllers for each pump leading to the potential complication of uneven flow dynamics and the requirements for a large amount of body space. This paper illustrates the combination of the LVAD and RVAD as one complete device to augment the function of both the left and right cardiac chambers with double impellers. The proposed device has two impellers rotating in counter directions, hence eliminating the necessity of the body muscles and tubing/heart connection to restrain the pump. The device will also have two separate chambers with independent rotating impeller for the left and right chambers. A problem with centrifugal impellers is the fluid stagnation underneath the impeller. This leads to thrombosis and blood clots.This paper presents the design, construction and location of washout hole to prevent thrombus for a Bi-VAD centrifugal pump. Results using CFD will be used to illustrate the superiority of our design concept in terms of preventing thrombus formation and hemolysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: In the current climate of medical education, there is an ever-increasing demand for and emphasis on simulation as both a teaching and training tool. The objective of our study was to compare the realism and practicality of a number of artificial blood products that could be used for high-fidelity simulation. Method: A literature and internet search was performed and 15 artificial blood products were identified from a variety of sources. One product was excluded due to its potential toxicity risks. Five observers, blinded to the products, performed two assessments on each product using an evaluation tool with 14 predefined criteria including color, consistency, clotting, and staining potential to manikin skin and clothing. Each criterion was rated using a five-point Likert scale. The products were left for 24 hours, both refrigerated and at room temperature, and then reassessed. Statistical analysis was performed to identify the most suitable products, and both inter- and intra-rater variability were examined. Results: Three products scored consistently well with all five assessors, with one product in particular scoring well in almost every criterion. This highest-rated product had a mean rating of 3.6 of 5.0 (95% posterior Interval 3.4-3.7). Inter-rater variability was minor with average ratings varying from 3.0 to 3.4 between the highest and lowest scorer. Intrarater variability was negligible with good agreement between first and second rating as per weighted kappa scores (K = 0.67). Conclusion: The most realistic and practical form of artificial blood identified was a commercial product called KD151 Flowing Blood Syrup. It was found to be not only realistic in appearance but practical in terms of storage and stain removal.