992 resultados para BRACKETS DE AUTO-LIGADO
Resumo:
Discute-se a teoria da Reabilitação Psicossocial, proposta por Benedetto Saraceno, tomando como referencial a teoria de Sistemas Auto-Organizados, elaborada, entre outros, por Michel Debrun. Observa-se que a proposta de Saraceno satisfaz diversos aspectos do processo de auto-organização, porém não chega a se constituir plenamente como tal. A partir dessa reflexão, pode-se entender melhor algumas das dificuldades da prática de reabilitação na área de Saúde Mental.
Resumo:
Objective: To evaluate the maximum residual signal auto-correlation also known as pitch amplitude (PA) values in patients with Parkinson's disease (PD) patients. Method. The signals of 21 Parkinson's patients were compared with 15 healthy individuals, divided according age and gender. Results: Statistical difference was seen between groups for PA, 0.39 for controls and 0.25 for PD. Normal value threshold was set as 0.3; (p <= 0.001). In the Parkinson's group 80.77%, and in the control group only 12.28%, had a PA < 0.3 demonstrating an association between these variables. The dispersion diagram for age and PA for PD individuals showed p=0.01 and r=0.54. There was no significant difference in relation to gender and PA between groups: Conclusion: the significant differences in pitch's amplitude between PD patients and healthy individuals demonstrate the methods specificity.-The results showed the need of prospective controlled studies,to improve the use and indications of residual signal auto-correlation to evaluate speech in PD patients.
Resumo:
The aim of this study was to evaluate the shear bond strength of brackets bonded with different restorative systems and compare it with that afforded by an established orthodontic bonding system. Seventy human bicuspids were used, divided into five different groups with 14 teeth each. Whereas a specific orthodontic bonding resin (Transbond (TM) XT) was used in the control group, the restorative systems Charisma, Tetric Ceram, TPH Spectrum and Z100 were used in the other four groups. Seven days after bonding the brackets to the samples, shear forces were applied under pressure in a universal testing machine. The data collected was evaluated using the ANOVA test and, when a difference was identified, the Tukey test was applied. A 5% level of significance was adopted. The mean results of the shear bond strength tests were as follows: Group 1 (Charisma), 14.98 MPa; Group 2 (Tetric Ceram), 15.16 MPa; Group 3 (TPH), 17.70 MPa; Group 4 (Z100), 13.91 MPa; and Group 5 or control group (Transbond (TM) XT), 17.15 MPa. No statistically significant difference was found among the groups. It was concluded that all tested resins have sufficient bond strength to be recommended for bonding orthodontic brackets.
Resumo:
We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.
Resumo:
The objective of this study is to translate to Brazilian Portuguese, and validate (criterion) it to the Brazilian population, the Women's Health Questionnaire (WHQ), questionnaire was developed by Hunter (1992) in order to evaluate physical and mental symptoms, which were experienced by women, along their climacteric transition. A sample of 63 women, from 45 to 65 years old, was selected from the HC-UNESP staff and HC-Community Health School Center users. The WHQ and the General Health Questionnaire - GHQ (Goldberg-1972 - 60 items) were answered by all of them. The GHQ was used as reference. Pearson correlation coefficient, sensitivity and specificity were calculated for assessing the validity of the questionnaire. Cut-off points were determined in the WHQ by linear regressions (the reference was GHQ's cut-off points - higher than 2). Outcomes highlighted a general index of sensitivity of 0.83, specificity of 0.87, and correlation of - 0.82 and reliability of 0.89. The study sample does not portray the general population because the persons interviewed had high level of education. As the WHQ is easy to be applied and analyzed, it could be used in general, gynecologic, oncology and psychiatric practice.
Resumo:
Ninety eight strains of glucose-nonfermenting Gram-negative bacilli were analyzed and isolated from several clinical materials of 95 patients admitted at the Dr. Domingos Leonardo Cerávolo University Hospital and three from outpatients. All of them were assisted in the Laboratory of Clinical Analysis of Unoeste University, Presidente Prudente, SP, from the period of October of 1999 to April of 2001. In this work, the level of agreement between the semi-automated commercial system AutoScan-4 and the conventional system for the identification of those bacteria were studied comparatively. There was agreement in 81 (82.7%), showing that both methodologies are useful for identification; partial agreement in six strains (6.1%) and disagreement in 11 (11.2%). The comercial system did not identify nine (9.2%) of the strains and reported them as very rare biotypes.
Resumo:
The purpose of our investigation is to compare the intrapulpal temperature changes following blue LED system and halogen lamp irradiation at the enamel surface of permanent teeth. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Several light sources can be used: halogens, arc plasma, lasers, and recently blue LED systems. An important aspect to be observed during such a procedures is the temperature change. In this study, we have used nine human extracted permanent teeth: three central incisors, three lateral incisors, and three canines. Teeth were exposed to two light sources: blue LED system (preliminary commercial model LEC 470-II) and halogen lamp (conventional photo-cure equipment). The surface of teeth was exposed for 20, 40, and 60 sec at the buccal and lingual enamel surface with an angle of 45 degrees. Temperature values measured by a thermistor placed at pulpar chamber were read in time intervals of 1 sec. We obtained plots showing the temperature evolution as a function of time for each experiment. There is a correlation between heating quantity and exposition time of light source: with increasing exposition time, heating increases into the pulpal chamber. The halogen lamp showed higher heating than the LED system, which showed a shorter time of cooling than halogen lamp. The blue LED system seems like the indicated light source for photo-cure of composite resin during the bonding of brackets. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Blue LED equipment did not heat during its use. This could permit a shorter clinical time of operation and better performance. © Mary Ann Liebert, Inc.
Resumo:
Sjögren's syndrome is an autoimmune disease characterized by sialoadenitis and elevated titers of autoantibodies. To assess whether it is possible to induce inflammatory changes in salivary gland tissues, a series of immunizations in Balb/c mice have been undertaken, using salivary gland extract, modified or not, added to several adjuvants. Mice's humoral immune response to salivary gland antigens was monitored by ELISA. Inflammatory cells infiltrating gland tissue were seen 3 months after immunization with salivary gland extract modified with pepsin (AgGp) and metaperiodate (AgGMp). Although pathological progression was not observed, the histopathological picture was similar to the initial phase of Sjögren's syndrome. In addition, a monoclonal antibody reactive with 3 gland polypeptides and anhydrase carbonic II was rescued among B cells from immunized mice. Thus, immunizations with modified autoantigens were able to initiate pathological damage to glandular tissue and stimulate the proliferation of auto-reactive B cells.
Resumo:
Incluye Bibliografía
Resumo:
Autoimmune bullous dermatoses are diseases in which blisters and vesicles are the primary and fundamental types of skin lesion. Their classification is based on the location of the blister: intraepidermal and subepidermal. Patients produce autoantibodies against self-specific structures of the skin detectable by immunofluorescence techniques, immunoblotting and ELISA. Recent advances in molecular and cellular biology have brought to knowledge these self-antigens, against which patients are sensitized, and which are found in epidermis or in the dermo-epidermal junction. These are low incidence, but high morbidity diseases that may be fatal. The aim of this article is to review and describe the progress of four autoimmune vesiculobullous disorders: endemic pemphigus foliaceous (wild fire), pemphigus vulgaris, bullous pemphigoid and dermatitis herpetiformis. ©2009 by Anais Brasileiros de Dermatologia.
Resumo:
Objective: To identify the effect of a self-instructive method (comic strip), applied with distinct approaches and evaluated over two periods, on the oral health of schoolchildren. Method: The sample comprised 2nd year elementary schoolchildren chosen randomly and divided into four groups: a control group (G1) which received no material, a reading group (G2), which was given the comic strip and read it in the classroom, a discussion group (G3), who received the comic strip, which was read out loud in the classroom and discussed, and a complete group (G4), which received the comic strip and which, after reading it, was asked to rewrite the story. O'Leary's plaque index was used as an evaluation instrument, measured immediately prior to application of the program and again 30 days later. The plaque index measured after and 30 days was compared, in each group, using the Wilcoxon test. The plaque index of the diferents groups was compared using the Kruskal-Walis test, in two moments diferents. The significance level was 5%. Results: The results of the evaluation revealed a statistically significant reduction (p<0.05) of the plaque index presented between the two periods in the four groups studied here. However, this reduction was considerably greater in the discussion and complete groups. Conclusion: The use of the self-instruction method associated with work on its content, as occurred in the discussion and complete groups, led to a better understanding of the subject matter, resulting in a higher reduction of plaque indices.
Resumo:
The aim of this in vitro study was to compare the photoactivation effects of QTH (Quartz-Tungsten-Halogen) and LED (Light-Emitting Diode) on the SBS (Shear Bond Strength) of orthodontic brackets at different debond times. Seventy-two bovine lower incisors were randomly divided into two groups according to the photoactivation system used (QTH or LED). The enamel surfaces were conditioned with Transbond self-etching primer, and APC (Adhesive Pre-Coated) brackets were used in all specimens. Group I was cured with QTH for 20 s and Group II with LED for 10 s. Both groups were subdivided according to the different experimental times after bonding (immediately, 24 h and 7 days). The specimens were tested for SBS and the enamel surfaces were analyzed according to the Adhesive Remnant Index (ARI). The statistical analysis included the Tukey's test to evaluate the main effects of photoactivation and debond time on SBS. The Chi-square test was used to compare the ARI values found for each group, and no statistically significant difference was observed. The debond time of 7 days for QTH photoactivation showed statistically greater values of SBS when compared to the immediate and 24 h periods. There was no statistically significant difference between the QTH and LED groups immediately and after the 24 h period. In conclusion, bonding orthodontic brackets with LED photoactivation for 10 s is suggested because it requires a reduced clinical chair time.
Resumo:
The aim of this study was to evaluate the effect of brushing with a Colgate 360° or Oral B Indicator 35 toothbrush on the shear bond strength of orthodontic brackets bonded to extracted human teeth. The bristle wear and bristle tip morphology were also examined after simulated tooth-brushing. Orthodontic brackets (Roth-P/1 st and 2 nd pre-molar S/D- Slot 0.18) were bonded (Transbond XT ®) to the smoothest surface of each of 45 extracted human molar and premolar teeth. Test specimens were randomly divided into three groups: Group 1, control group with no brushing; Group 2, brushing with the Oral B Indicator 35; Group 3, brushing with the Colgate 360°. Samples were adapted to a machine that simulated tooth-brushing. The bond strength of each bracket to each tooth was assessed with a mechanical testing machine. The bristle wear and bristle tip morphology indices were also assessed. Statistically significant differences were defined for p ≤ 0.05. The average bond strengths (range: 90.18-90.89 kgf/cm 2) did not differ among the three groups. The Colgate 360° showed less bristle wear and a better bristle tip morphology than the Oral B Indicator 35 toothbrush. However, use of either toothbrush did not decrease the bond strength of the orthodontic brackets. Therefore, patients undergoing orthodontic therapy can safely use either toothbrush.
Resumo:
Multipulse rectifier topologies based on autoconnections, or differential connections, are more and more applied as interface stages between the mains and power converters. These topologies mitigate many low-order current harmonics in the utility, reducing the THD (total harmonic distortion) and increasing the power factor. This paper presents a mathematical model based on phasor diagrams, that results in a single expression able to unify all differential topologies connections (Delta and Wye), for both step-up or step-down autotransformers, for 12 and 18-pulse AC-DC converters. The proposed family of converters can be designed for any relationship between the input voltage and the load voltage. An immediate application would be the retrofit, i.e. to replace a conventional rectifier with poor quality of the processed energy by the 12 or 18 pulses rectifier with Wye or Delta-differential connection. The design procedure, simple and fast, is developed and tested for a prototype rating 6 kW and 250 V on the DC load © 2010 IEEE.