995 resultados para Air Sampling
Resumo:
An examination of the impact in the US and EU markets of two major innovations in the provision of air services on thin routes - regional jet technology and the low-cost business model - reveals significant differences. In the US, regional airlines monopolize a high proportion of thin routes, whereas low-cost carriers are dominant on these routes in Europe. Our results have different implications for business and leisure travelers, given that regional services provide a higher frequency of flights (at the expense of higher fares), while low-cost services offer lower fares (at the expense of lower flight frequencies).
Resumo:
A photonic system has been developed that enables sensitive quantitative determination of reactive oxygen species (ROS) - mainly hydrogen peroxide (H2O2) - in aerosol samples such as airborne nanoparticles and exhaled air from patients. The detection principle relies on the amplification of the absorbance under multiple scattering conditions due to optical path lengthening [1] and [2]. In this study, the presence of cellulose membrane that acts as random medium into the glass optical cell considerably improved the sensitivity of the detection based on colorimetric FOX assay (FeII/orange xylenol). Despite the loss of assay volume (cellulose occupies 75% of cell volume) the limit of detection is enhanced by one order of magnitude reaching the value of 9 nM (H2O2 equivalents). Spectral analysis is performed automatically with a periodicity of 5 to 15 s, giving rise to real-time ROS measurements. Moreover, the elution of air sample into the collection chamber via a micro-diffuser (impinger) enables quantitative determination of ROS contained in or generated from airborne samples. As proof-of-concept the photonic ROS detection system was used in the determination of both ROS generated from traffic pollution and ROS contained in the exhaled breath as lung inflammation biomarkers.
Resumo:
L'exposition professionnelle aux nanomatériaux manufacturés dans l'air présente des risques potentiels pour la santé des travailleurs dans les secteurs de la nanotechnologie. Il est important de comprendre les scénarios de libération des aérosols de nanoparticules dans les processus et les activités associées à l'exposition humaine. Les mécanismes de libération, y compris les taux de libération et les propriétés physico-chimiques des nanoparticules, déterminent leurs comportements de transport ainsi que les effets biologiques néfastes. La distribution de taille des particules d'aérosols est l'un des paramètres les plus importants dans ces processus. La stabilité mécanique d'agglomérats de nanoparticules affecte leurs distributions de tailles. Les potentiels de désagglomération de ces agglomérats déterminent les possibilités de leur déformation sous énergies externes. Cela rend les changements possibles dans leur distribution de taille et de la concentration en nombre qui vont finalement modifier leurs risques d'exposition. Les conditions environnementales, telles que l'humidité relative, peuvent influencer les processus de désagglomération par l'adhérence de condensation capillaire de l'humidité. L'objectif général de cette thèse était d'évaluer les scénarios de libération des nanomatériaux manufacturés des processus et activités sur le lieu de travail. Les sous-objectifs étaient les suivants: 1. Etudier les potentiels de désagglomération des nanoparticules dans des conditions environnementales variées. 2. Etudier la libération des nano-objets à partir de nanocomposites polymères; 3. Evaluer la libération de nanoparticules sur le lieu de travail dans des situations concrètes. Nous avons comparé différents systèmes de laboratoire qui présentaient différents niveau d'énergie dans l'aérosolisation des poudres. Des nanopoudres de TiO2 avec des hydrophilicités de surface distinctes ont été testées. Un spectromètre à mobilité électrique (SMPS), un spectromètre à mobilité aérodynamique (APS) et un spectromètre optique (OPC) ont été utilisés pour mesurer la concentration de particules et la distribution de taille des particules. La microscopie électronique à transmission (TEM) a été utilisée pour l'analyse morphologique d'échantillons de particules dans l'air. Les propriétés des aérosols (distribution de taille et concentration en nombre) étaient différentes suivant la méthode employée. Les vitesses des flux d'air d'aérosolisation ont été utilisées pour estimer le niveau d'énergie dans ces systèmes, et il a été montré que les tailles modales des particules étaient inversement proportionnelles à la vitesse appliquée. En général, les particules hydrophiles ont des diamètres plus grands et des nombres inférieurs à ceux des particules hydrophobes. Toutefois, cela dépend aussi des méthodes utilisées. La vitesse de l'air peut donc être un paramètre efficace pour le classement de l'énergie des procédés pour des systèmes d'aérosolisation similaires. Nous avons développé un système laboratoire pour tester les potentiels de désagglomération des nanoparticules dans l'air en utilisant des orifices critiques et un humidificateur. Sa performance a été comparée à un système similaire dans un institut partenaire. Une variété de nanopoudres différentes a été testée. Le niveau d'énergie appliquée et l'humidité ont été modifiés. Le SMPS et l'OPC ont été utilisés pour mesurer la concentration de particules et la distribution de la taille. Un TEM a été utilisé pour l'analyse morphologique d'échantillons de particules dans l'air. Le diamètre moyen des particules a diminué et la concentration en nombre s'est accrue lorsque des énergies externes ont été appliquées. Le nombre de particules inférieures à 100 nm a été augmenté, et celui au-dessus de 350 nm réduits. Les conditions humides ont faits exactement le contraire, en particulier pour les petites particules. En outre, ils ont réduits les effets de la différence de pression due à l'orifice. Les résultats suggèrent que la désagglomération d'agglomérats de nanoparticules dans l'air est possible dans la gamme d'énergie appliquée. Cependant, l'atmosphère humide peut favoriser leur agglomération et améliorer leurs stabilités en réduisant la libération de nanoparticules dans l'environnement. Nous proposons d'utiliser notre système pour le test de routine des potentiels de désagglomération des nanomatériaux manufacturés et de les classer. Un tel classement faciliterait la priorisation de l'exposition et du risque encouru en fonction du niveau d'ENM. Un système de perçage automatique et un système de sciage manuel ont été développés pour étudier la libération de nanoparticules à partir de différents types de nanocomposites. La vitesse de perçage et taille de la mèche ont été modifiées dans les expériences. La distribution de taille des particules et leur concentration en nombre ont été mesurées par un SMPS et un miniature diffusion size classifier (DISCmini). Les distributions de nanoparticules dans les composites et les particules libérées ont été analysés par un TEM et un microscope électronique à balayage (SEM). Les tests de perçage ont libérés un plus grand nombre de particules que le sciage. Des vitesses de perçage plus rapide et les mèches plus grandes ont augmentés la génération de particules. Les charges de nanoparticules manufacturées dans les composites ne modifient pas leurs comportements de libération dans les expériences de perçage. Toutefois, le sciage différencie les niveaux de libération entre les composites et les échantillons blancs. De plus, les vapeurs de polymères ont été générées par la chaleur de sciage. La plupart des particules libérées sont des polymères contenant des nanoparticules ou sur leurs surface. Les résultats ont souligné l'importance du type de processus et paramètres pour déterminer la libération de nanoparticules de composites. Les émissions secondaires telles que les fumées polymères appellent à la nécessité d'évaluations de l'exposition et de risque pour de tels scénarios. Une revue systématique de la littérature sur le sujet de libérations de nanoparticules dans l'air dans les secteurs industriels et laboratoires de recherche a été effectuée. Des stratégies de recherche des informations pertinentes et de stockage ont été développées. Les mécanismes de libération, tels que la taille de particules d'aérosol et de leur concentration en nombre, ont été comparés pour différentes activités. La disponibilité de l'information contextuelle qui est pertinente pour l'estimation de l'exposition humaine a été évaluée. Il a été constaté que les données relatives à l'exposition ne sont pas toujours disponibles dans la littérature actuelle. Les propriétés des aérosols libérés semblent dépendre de la nature des activités. Des procédés à haute énergie ont tendance à générer des plus hauts niveaux de concentrations de particules dans les gammes de plus petite taille. Les résultats peuvent être utiles pour déterminer la priorité des procédés industriels pour l'évaluation les risques associés dans une approche à plusieurs niveaux. Pour l'évaluation de l'exposition, la disponibilité de l'information peut être améliorée par le développement d'une meilleure méthode de communication des données.
Resumo:
Given their central role in mercury (Hg) excretion and suitability as reservoirs, bird feathers are useful Hg biomonitors. Nevertheless, the interpretation of Hg concentrations is still questioned as a result of a poor knowledge of feather physiology and mechanisms affecting Hg deposition. Given the constraints of feather availability to ecotoxicological studies, we tested the effect of intra-individual differences in Hg concentrations according to feather type (body vs. flight feathers), position in the wing and size (mass and length) in order to understand how these factors could affect Hg estimates. We measured Hg concentration of 154 feathers from 28 un-moulted barn owls (Tyto alba), collected dead on roadsides. Median Hg concentration was 0.45 (0.076-4.5) mg kg(-1) in body feathers, 0.44 (0.040-4.9) mg kg(-1) in primary and 0.60 (0.042-4.7) mg kg(-1) in secondary feathers, and we found a poor effect of feather type on intra-individual Hg levels. We also found a negative effect of wing feather mass on Hg concentration but not of feather length and of its position in the wing. We hypothesize that differences in feather growth rate may be the main driver of between-feather differences in Hg concentrations, which can have implications in the interpretation of Hg concentrations in feathers. Finally, we recommend that, whenever possible, several feathers from the same individual should be analysed. The five innermost primaries have lowest mean deviations to both between-feather and intra-individual mean Hg concentration and thus should be selected under restrictive sampling scenarios.
Resumo:
Objective The authors have sought to study the calibration of a clinical PKA meter (Diamentor E2) and a calibrator for clinical meters (PDC) in the Laboratory of Ionizing Radiation Metrology at Instituto de Energia e Ambiente - Universidade de São Paulo. Materials and Methods Different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm3 cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results The lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion The calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference.
Resumo:
The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.
Resumo:
This study aimed at comparing the efficiency of various sampling materials for the collection and subsequent analysis of organic gunshot residues (OGSR). To the best of our knowledge, it is the first time that sampling devices were investigated in detail for further quantitation of OGSR by LC-MS. Seven sampling materials, namely two "swab"-type and five "stub"-type collection materials, were tested. The investigation started with the development of a simple and robust LC-MS method able to separate and quantify molecules typically found in gunpowders, such as diphenylamine or ethylcentralite. The evaluation of sampling materials was then systematically carried out by first analysing blank extracts of the materials to check for potential interferences and determining matrix effects. Based on these results, the best four materials, namely cotton buds, polyester swabs, a tape from 3M and PTFE were compared in terms of collection efficiency during shooting experiments using a set of 9 mm Luger ammunition. It was found that the tape was capable of recovering the highest amounts of OGSR. As tape-lifting is the technique currently used in routine for inorganic GSR, OGSR analysis might be implemented without modifying IGSR sampling and analysis procedure.
Resumo:
In the present paper, we report on the analytical use of a dynamic droplet based gas collection and an analysis system. A droplet formed at the tip of a tube represents a sampling approach that provides an indefinitely renewable surface and uses very little reagent. Sample gas flows past the droplet at a low flow rate. After the gas was sampled , the analysis can be carried out by different methodologies. The feasibility of the sensor is demonstrated by continuos determination of gaseous as: NO2, Cl2 and SO2.
Resumo:
We study the relationship between stable sampling sequences for bandlimited functions in $L^p(\R^n)$ and the Fourier multipliers in $L^p$. In the case that the sequence is a lattice and the spectrum is a fundamental domain for the lattice the connection is complete. In the case of irregular sequences there is still a partial relationship.
Resumo:
The presence of low carbonyl compounds (C1-C4) and glutaraldehyde was observed in 14 work-locations in São Paulo city, Brazil, during January to July 1997 period. The quantification of other carbonyls was not possible due to a sampling artifact caused probably by undesirable reactions between the ambient ozone and the organic substract of C18 cartridge used to collect carbonyls. High indoor concentrations, compared to outdoor levels, were observed for all compounds. Formaldehyde was the most abundant species (29 ppb) followed by acetone and acetaldehyde (25 and 17 ppb) with a small contribution of propanal, crotonaldehyde and C4 isomers (0.7 to 1.5 ppb) when related to the total indoor carbonyls level. Glutaraldehyde was observed only in two different occupational locations in a hospital at high concentrations (121 ppb). In general, high individual carbonyl levels as well as total carbonyls levels found in several locations indicated an unpropitious air quality for the occupants of these non-industrial sites.
Resumo:
A sensitive and simple system was proposed for the in situ measurement of total aldehyde in outdoor or indoor ambient. The method is based on the use of a reagent drop as an useful interface to preconcentrate the sample prior to determination of total aldehyde as formaldehyde. The drop is formed at the tip of a cylindrical tube that contains two optical fibers placed on opposite sides and in contact with the reagent solution. One optical fiber carries the red light to the drop form a light emitting diode (LED). The transmitted light is measured by a second optical fiber/photodiode system. The analytical signal is read and converted into absorbance. The reagent solution of 3-methyl-2-benzothiazoline hydrazone (MBTH) forms a blue cation during reaction with formaldehyde that can be measured at 660 nm. Some aspects of kinetics reaction formation of dye were reevaluated. The formaldehyde reacts with MBTH and forms the azine in about 12 min. The oxidation of MBTH by Fe (III) and the formation of dye requires 3 min. The absorbance of the reagent drop is proportional to the sampling time and to the analyte concentration. The absorbance signal increases with increased sample gas flow until a maximum is reached then decreases until it forms a plateau. The proposed method was evaluated using both outdoor and indoor samples, and it was shown to viable provide an accurate measure of total aldehyde.
Resumo:
There is an increasing interest in the use of breath analysis for monitoring human physiology and exposure to toxic substances or environmental pollutants. This review focuses on the current status of the sampling procedures, collection devices and sample-enrichment methodologies used for exhaled breath-vapor analysis. We discuss the different parameters affecting each of the above steps, taking into account the requirements for breath analysis in exposure assessments and the need to analyze target compounds at sub-ppbv levels. Finally, we summarize the practical applications of exposure analysis in the past two decades
Comparação de duas metodologias de amostragem atmosférica com ferramenta estatística não paramétrica
Resumo:
In atmospheric aerosol sampling, it is inevitable that the air that carries particles is in motion, as a result of both externally driven wind and the sucking action of the sampler itself. High or low air flow sampling speeds may lead to significant particle size bias. The objective of this work is the validation of measurements enabling the comparison of species concentration from both air flow sampling techniques. The presence of several outliers and increase of residuals with concentration becomes obvious, requiring non-parametric methods, recommended for the handling of data which may not be normally distributed. This way, conversion factors are obtained for each of the various species under study using Kendall regression.