991 resultados para Air Pollutants, Occupational
Resumo:
Although there is an abundance of literature concerning the ingestion of food contaminated with aflatoxin B1 (AFB1), only a small number of studies explore mycotoxin exposure in occupational settings. Taking this into consideration, our study was developed with the intention of elucidating whether there is occupational exposure to AFB1 in Portuguese poultry and swine production facilities. A specific biomarker was used to assess exposure to AFB1. A total of 45 workers (34 from poultry farms; 11 from swine production facilities) participated in this study, providing blood samples. Additionally, a control group (n=30) composed of subjects without any type of contact with agricultural activity was considered. All participants signed a consent form and were provided with the study protocol. Eighteen poultry workers (58.6%) and six workers from the swine production facilities (54.5%) showed detectable levels of AFB1. In the control group, the AFB1 values were all below 1 ng/ml. No significant differences in AFB1 levels in serum between workers from poultry and swine farms were found. Poultry workers, however, showed the highest serum levels and a significant statistical difference between this group and the control group was found. Results suggest that exposure to AFB1 by inhalation occurs in both occupational settings representing an additional risk that needs to be recognised, assessed and prevented.
Resumo:
Verso preprint.
Resumo:
Bearing in mind the potential adverse health effects of ultrafine particles, it is of paramount importance to perform effective monitoring of nanosized particles in several microenvironments, which may include ambient air, indoor air, and also occupational environments. In fact, effective and accurate monitoring is the first step to obtaining a set of data that could be used further on to perform subsequent evaluations such as risk assessment and epidemiologic studies, thus proposing good working practices such as containment measures in order to reduce occupational exposure. This paper presents a useful methodology for monitoring ultrafine particles/nanoparticles in several microenvironments, using online analyzers and also sampling systems that allow further characterization on collected nanoparticles. This methodology was validated in three case studies presented in the paper, which assess monitoring of nanosized particles in the outdoor atmosphere, during cooking operations, and in a welding workshop.
Resumo:
Epidemiological studies showed increased prevalence of respiratory symptoms and adverse changes in pulmonary function parameters in poultry workers, corroborating the increased exposure to risk factors, such as fungal load and their metabolites. This study aimed to determine the occupational exposure threat due to fungal contamination caused by the toxigenic isolates belonging to the complex of the species of Aspergillus flavus and also isolates fromAspergillus fumigatus species complex. The study was carried out in seven Portuguese poultries, using cultural and molecularmethodologies. For conventional/cultural methods, air, surfaces, and litter samples were collected by impaction method using the Millipore Air Sampler. For the molecular analysis, air samples were collected by impinger method using the Coriolis air sampler. After DNA extraction, samples were analyzed by real-time PCR using specific primers and probes for toxigenic strains of the Aspergillus flavus complex and for detection of isolates from Aspergillus fumigatus complex. Through conventional methods, and among the Aspergillus genus, different prevalences were detected regarding the presence of Aspergillus flavus and Aspergillus fumigatus species complexes, namely: 74.5 versus 1.0% in the air samples, 24.0 versus 16.0% in the surfaces, 0 versus 32.6% in new litter, and 9.9 versus 15.9%in used litter. Through molecular biology, we were able to detect the presence of aflatoxigenic strains in pavilions in which Aspergillus flavus did not grow in culture. Aspergillus fumigatus was only found in one indoor air sample by conventional methods. Using molecular methodologies, however, Aspergillus fumigatus complex was detected in seven indoor samples from three different poultry units. The characterization of fungal contamination caused by Aspergillus flavus and Aspergillus fumigatus raises the concern of occupational threat not only due to the detected fungal load but also because of the toxigenic potential of these species.
Resumo:
Certain environmental conditions in animal and plant production have been associated with increased frequency in respiratory illnesses, including asthma, chronic bronchitis, and hypersensitivity pneumonitis, in farmers occupationally exposed in swine production. The aim of this study was to characterize particulate matter (PM) contamination in seven Portuguese swine farms and determine the existence of clinical symptoms associated with asthma and other allergy diseases, utilizing the European Community Respiratory Health Survey questionnaire. Environmental assessments were performed with portable direct-reading equipment, and PM contamination including five different sizes (PM0.5, PM1.0, PM2.5, PM5.0, PM10) was determined. The distribution of particle size showed the same trend in all swine farms, with high concentrations of particles with PM5 and PM10. Results from the questionnaire indicated a trend such that subjects with diagnosis of asthma were exposed to higher concentrations of PM with larger size (PM2.5, PM5, and PM10) while subjects with sneezing, runny nose, or stuffy nose without a cold or flu were exposed to higher concentrations of PM with smaller size (PM0.5 and PM1). Data indicate that inhalation of PM in swine farm workers is associated with increased frequency of respiratory illnesses.
Resumo:
This study evaluates the dosimetric impact caused by an air cavity located at 2 mm depth from the top surface in a PMMA phantom irradiated by electron beams produced by a Siemens Primus linear accelerator. A systematic evaluation of the effect related to the cavity area and thickness as well as to the electron beam energy was performed by using Monte Carlo simulations (EGSnrc code), Pencil Beam algorithm and Gafchromic EBT2 films. A home-PMMA phantom with the same geometry as the simulated one was specifically constructed for the measurements. Our results indicate that the presence of the cavity causes an increase (up to 70%) of the dose maximum value as well as a shift forward of the position of the depthedose curve, compared to the homogeneous one. Pronounced dose discontinuities in the regions close to the lateral cavity edges are observed. The shape and magnitude of these discontinuities change with the dimension of the cavity. It is also found that the cavity effect is more pronounced (6%) for the 12 MeV electron beam and the presence of cavities with large thickness and small area introduces more significant variations (up to 70%) on the depthedose curves. Overall, the Gafchromic EBT2 film measurements were found in agreement within 3% with Monte Carlo calculations and predict well the fine details of the dosimetric change near the cavity interface. The Pencil Beam calculations underestimate the dose up to 40% compared to Monte Carlo simulations; in particular for the largest cavity thickness (2.8 cm).
Resumo:
Throughout the world, epidemiological studies were established to examine the relationship between air pollution and mortality rates and adverse respiratory health effects. However, despite the years of discussion the correlation between adverse health effects and atmospheric pollution remains controversial, partly because these studies are frequently restricted to small and well-monitored areas. Monitoring air pollution is complex due to the large spatial and temporal variations of pollution phenomena, the high costs of recording instruments, and the low sampling density of a purely instrumental approach. Therefore, together with the traditional instrumental monitoring, bioindication techniques allow for the mapping of pollution effects over wide areas with a high sampling density. In this study, instrumental and biomonitoring techniques were integrated to support an epidemiological study that will be developed in an industrial area located in Gijon in the coastal of central Asturias, Spain. Three main objectives were proposed to (i) analyze temporal patterns of PM10 concentrations in order to apportion emissions sources, (ii) investigate spatial patterns of lichen conductivity to identify the impact of the studied industrial area in air quality, and (iii) establish relationships amongst lichen conductivity with some site-specific characteristics. Samples of the epiphytic lichen Parmelia sulcata were transplanted in a grid of 18 by 20 km with an industrial area in the center. Lichens were exposed for a 5-mo period starting in April 2010. After exposure, lichen samples were soaked in 18-M water aimed at determination of water electrical conductivity and, consequently, lichen vitality and cell damage. A marked decreasing gradient of lichens conductivity relative to distance from the emitting sources was observed. Transplants from a sampling site proximal to the industrial area reached values 10-fold higher than levels far from it. This finding showed that lichens reacted physiologically in the polluted industrial area as evidenced by increased conductivity correlated to contamination level. The integration of temporal PM10 measurements and analysis of wind direction corroborated the importance of this industrialized region for air quality measurements and identified the relevance of traffic for the urban area.
Resumo:
Agricultural workers especially poultry farmers are at increased risk of occupational respiratory diseases. Epidemiological studies showed increased prevalence of respiratory symptoms and adverse changes in pulmonary function parameters in poultry workers. In poultry production volatile organic compounds (VOCs) presence can be due to some compounds produced by molds that are volatile and are released directly into the air. These are known as microbial volatile organic compounds (MVOCs). Because these compounds often have strong and/or unpleasant odors, they can be the source of odors associated with molds. MVOC's are products of the microorganisms primary and secondary metabolism and are composed of low molecular weight alcohols, aldehydes, amines, ketones, terpenes, aromatic and chlorinated hydrocarbons, and sulfur-based compounds, all of which are variations of carbon-based molecules.
Resumo:
Water covers over 70% of the Earth's surface, and is vital for all known forms of life. But only 3% of the Earth's water is fresh water, and less than 0.3% of all freshwater is in rivers, lakes, reservoirs and the atmosphere. However, rivers and lakes are an important part of fresh surface water, amounting to about 89%. In this Master Thesis dissertation, the focus is on three types of water bodies rivers, lakes and reservoirs, and their water quality issues in Asian countries. The surface water quality in a region is largely determined both by the natural processes such as climate or geographic conditions, and the anthropogenic influences such as industrial and agricultural activities or land use conversion. The quality of the water can be affected by pollutants discharge from a specific point through a sewer pipe and also by extensive drainage from agriculture/urban areas and within basin. Hence, water pollutant sources can be divided into two categories: Point source pollution and Non-point source (NPS) pollution. Seasonal variations in precipitation and surface run-off have a strong effect on river discharge and the concentration of pollutants in water bodies. For example, in the rainy season, heavy and persistent rain wash off the ground, the runoff flow increases and may contain various kinds of pollutants and, eventually, enters the water bodies. In some cases, especially in confined water bodies, the quality may be positive related with rainfall in the wet season, because this confined type of fresh water systems allows high dilution of pollutants, decreasing their possible impacts. During the dry season, the quality of water is largely related to industrialization and urbanization pollution. The aim of this study is to identify the most common water quality problems in Asian countries and to enumerate and analyze the methodologies used for assessment of water quality conditions of both rivers and confined water bodies (lakes and reservoirs). Based on the evaluation of a sample of 57 papers, dated between 2000 and 2012, it was found that over the past decade, the water quality of rivers, lakes, and reservoirs in developing countries is being degraded. Water pollution and destruction of aquatic ecosystems have caused massive damage to the functions and integrity of water resources. The most widespread NPS in Asian countries and those which have the greatest spatial impacts are urban runoff and agriculture. Locally, mine waste runoff and rice paddy are serious NPS problems. The most relevant point pollution sources are the effluents from factories, sewage treatment plant, and public or household facilities. It was found that the most used methodology was unquestionably the monitoring activity, used in 49 of analyzed studies, accounting for 86%. Sometimes, data from historical databases were used as well. It can be seen that taking samples from the water body and then carry on laboratory work (chemical analyses) is important because it can give an understanding of the water quality. 6 papers (11%) used a method that combined monitoring data and modeling. 6 papers (11%) just applied a model to estimate the quality of water. Modeling is a useful resource when there is limited budget since some models are of free download and use. In particular, several of used models come from the U.S.A, but they have their own purposes and features, meaning that a careful application of the models to other countries and a critical discussion of the results are crucial. 5 papers (9%) focus on a method combining monitoring data and statistical analysis. When there is a huge data matrix, the researchers need an efficient way of interpretation of the information which is provided by statistics. 3 papers (5%) used a method combining monitoring data, statistical analysis and modeling. These different methods are all valuable to evaluate the water quality. It was also found that the evaluation of water quality was made as well by using other types of sampling different than water itself, and they also provide useful information to understand the condition of the water body. These additional monitoring activities are: Air sampling, sediment sampling, phytoplankton sampling and aquatic animal tissues sampling. Despite considerable progress in developing and applying control regulations to point and NPS pollution, the pollution status of rivers, lakes, and reservoirs in Asian countries is not improving. In fact, this reflects the slow pace of investment in new infrastructure for pollution control and growing population pressures. Water laws or regulations and public involvement in enforcement can play a constructive and indispensable role in environmental protection. In the near future, in order to protect water from further contamination, rapid action is highly needed to control the various kinds of effluents in one region. Environmental remediation and treatment of industrial effluent and municipal wastewaters is essential. It is also important to prevent the direct input of agricultural and mine site runoff. Finally, stricter environmental regulation for water quality is required to support protection and management strategies. It would have been possible to get further information based in the 57 sample of papers. For instance, it would have been interesting to compare the level of concentrations of some pollutants in the diferente Asian countries. However the limit of three months duration for this study prevented further work to take place. In spite of this, the study objectives were achieved: the work provided an overview of the most relevant water quality problems in rivers, lakes and reservoirs in Asian countries, and also listed and analyzed the most common methodologies.
Resumo:
Mestrado em Engenharia Qumica.Ramo Tecnologias de Proteco Ambiental
Resumo:
Mestrado em Engenharia Qumica. Ramo Tecnologias de Proteco Ambiental.
Resumo:
Fungal contamination in composting facilities has been associated with increased respiratory and skin pathologies among compost workers. In this study we aim to characterize the fungal contamination caused by Aspergillus genera within a totally indoor composting plant located in Portugal. Air samples of 50L were collected from 6 sampling sites through an impaction method. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. Pre-treatment and waste screw were the sampling sites of the analyzed composting plant with the highest Aspergillus load in the air. Globally, the genus Aspergillus presented the highest prevalence both in the air from (90.6%), and surfaces from the same sampling sites (60.8%). The results obtained in this study claim the attention to the need of further research regarding the fungal contamination dur to Aspergillus genus in composting plants.
Resumo:
Several activities are ensured by dockers increase occupational exposure to several risk factors. being one of them the fungal burden from the load. In this study we aim at characterizing fungal contamination in one warehouse that storage sugar cane from a ship, and also in one crane cabinet that unload the same sugar cane from the ship. Air samples were collected from the warehouse and from inside the crane cabinet. An outdoor sample was also collected, from each sampling site, and regarding as reference. Sampling volume was selected depending in the contamination expected and the air samples were collect through an impaction method in a flow rate of 140 L/min onto malt extract agar (MEA) supplemented with chloramphenicol (0.05%), using the Millipore air Tester (Millipore). Surfaces samples from the warehouse were collected by swabbing the surfaces of the same indoor sites, using a 10 by 10cm square stencil according to the International Standard ISO 18593 (2004). The obtained swabs were then plated onto MEA. All the collected samples were incubated at 27C for 5 to 7 days. After laboratory processing and incubation of the collected samples, quantitative (colony-forming units - CFU/m3 and CFU/m2) and qualitative results were obtained with identification of the isolated fungal species. Aspergillus fumigatus present the highest fungal load and WHO guideline was overcome in both indoor sampling sites. The results obtained in this study highlight the need to know better the exposure burden from dockers, and specifically to fungi contamination.
Resumo:
Actualmente, a poluio do ar, gua e solo so problemticas nas quais se tm centrado diversos estudos. Reduzir ou eliminar a concentrao dos diversos poluentes presentes nestes meios uma meta que se pretende atingir. Neste mbito, tm sido desenvolvidos diversos estudos e trabalhos, utilizando diversas tecnologias, como qumicas e biolgicas, de forma a conseguir-se atingir este fim. Esta tese teve como principal objectivo estudar a remediao de solos contaminados com produtos farmacuticos recorrendo oxidao/reduo qumica. Assim, comeou por se estudar a remediao de gua contaminada com ibuprofeno, uma vez, que a matriz lquida mais fcil de estudar que o solo. Neste mbito escolheram-se os seguintes reagentes para estudar a descontaminao da gua: permanganato de potssio, reagente de Fenton e nanopartculas de ferro zero valente. Analisando os resultados obtidos nestas anlises, verificou-se que o permanganato de potssio no foi capaz de reduzir a concentrao de ibuprofeno presente na gua. No entanto, o reagente de Fenton e as nanopartculas produzidas a partir do extracto da casca de castanha e do ch conseguirem reagir com o ibuprofeno, apresentando taxas de degradao de 90 % e 77 %, respectivamente, nas melhores condies experimentadas. Com os resultados obtidos, passou-se a analisar solos contaminados com o ibuprofeno, utilizando o reagente de Fenton e as nanopartculas produzidas a partir de um extracto de ch. Verificou-se que estes reagentes conseguiram reduzir a concentrao de ibuprofeno presente no solo (areia) para valores residuais, obtendo-se taxas de degradao acima de 95 % aps 5 dias de reaco. Conclui-se que, o objectivo principal desta tese foi cumprido pois foi reduzida, e quase eliminada, a concentrao do ibuprofeno presente no solo, recorrendo oxidao/reduo qumica.
Resumo:
A procura de piscinas para a prtica de atividades desportivas, recreativas e/ou teraputicas tem sofrido um aumento gradual ao longo do tempo. No entanto, nas piscinas existem vrios perigos associados sua utilizao. Relativamente aos perigos qumicos, a utilizao de desinfetantes base de cloro, bromo ou compostos derivados vai, por um lado, inativar microrganismos patognicos mas, por outro, dar origem a subprodutos ao reagir com compostos orgnicos presentes na gua. Os trihalometanos so um exemplo de subprodutos que se podem formar e, entre os compostos principais, esto o clorofrmio (TCM), bromodiclorometano (BDCM), clorodibromometano (CDBM) e bromofrmio (TBM). Este trabalho teve como objetivo o desenvolvimento de uma metodologia analtica para a determinao de trihalometanos em gua e ar de piscinas e a sua aplicao a um conjunto de amostras. Para a anlise dos compostos, foi utilizada a microextrao em fase slida no espao de cabea (HS-SPME) com posterior quantificao dos compostos por cromatografia gasosa com detetor de captura eletrnica (GC-ECD). Foi realizada uma otimizao das condies de extrao dos compostos em estudo em amostras de gua, atravs da realizao de dois planeamentos experimentais. As condies timas so assim obtidas para uma temperatura de extrao de 45C, um tempo de extrao de 25 min e um tempo de dessoro de 5 min. Foram analisadas amostras de guas de piscina cedidas pelo Centro de Estudos de guas, sendo avaliada a aplicao da tcnica HS-SPME e o efeito de matriz. O modo como se manuseiam as solues que contm os compostos em estudo influencia os resultados devido ao facto destes serem bastante volteis. Concluiu-se tambm que existe efeito de matriz, logo a concentrao das amostras dever ser determinada atravs do mtodo de adio de padro. A caraterizao da gua de piscinas interiores permitiu conhecer a concentrao de trihalometanos (THMs). Foram obtidas concentraes de TCM entre 4,5 e 406,5 g/L sendo que apenas 4 das 27 amostras analisadas ultrapassam o valor limite imposto pelo Decreto-Lei n306/2007 (100 g/L) no que diz respeito a guas de consumo humano e que normalmente utilizado como valor indicativo para a qualidade das guas de piscina. Relativamente concentrao obtida no ar de uma piscina interior, foi detetada uma concentrao mdia de 224 g/m3 de TCM, valor muito abaixo dos 10000 g/m3 impostos pelo Decreto-lei n24/2012, como valor limite para exposio profissional a agentes qumicos.