933 resultados para Abrupt edges removal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dioctadecyldimethylammonium bromide (DODAB) is a double chain vesicle-forming cationic surfactant, whereas octa-ethyleneglycol mono-n-dodecyl ether (C12E8) is a single chain micelle-forming nonionic surfactant. At room temperature (ca. 22 degrees C) C12E8 molecules self-assemble in water as micelles while DODAB is insoluble. A mixture of DODAB and C12E8, however, can be soluble in water at room temperature depending on the relative amount of the compounds. We report the formation of small unilamellar vesicles (SUVs) by dialyzing at room temperature a mixture of 1.0 mM DODAB with 10 mM C12E8 in water. Extended bilayers are formed as well in equilibrium with vesicles. Such structures are viewed by a cryogenic transmission electron microscopy (cryo-TEM) image. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study investigated the influence of estrogen deficiency and its treatment with estrogen and alendronate on the removal torque of osseointegrated titanium implants.Methods: Fifty-eight female Wistar rats received a titanium implant in the tibia metaphysis. After 60 days, which was needed for implant osseointegration, the animals were randomly divided into five groups: control (CTLE; N = 10), sham surgery (SHAM; N = 12), ovariectomy (OVX; N = 12), ovariectomy followed by hormone replacement (EST; N = 12), and ovariectomy followed by treatment with alendronate (ALE; N = 12). The CTLE group was sacrificed to confirm osseointegration, whereas the remaining groups were submitted to sham surgery or ovariectomy according to their designations. After 90 days, these animals were also sacrificed. Densitometry of femur and lumbar vertebrae was performed by dual-energy x-ray absorptiometry (DXA) to confirm systemic impairment of the animals. All implants were subjected to removal torque.Results: Densitometric analysis of the femur and lumbar vertebrae confirmed a systemic impairment of the animals, disclosing lower values of bone mineral density for OVX. Analysis of the removal torque of the implants showed statistically lower values (P <0.05) for the OVX group in relation to the other groups. However, the group treated with alendronate (ALE group) presented significantly higher torque values compared to the others.Conclusion: According to this study, estrogen deficiency was observed to have a negative influence on the removal torque of osseointegrated implants, whereas treatment with alendronate

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There have been numerous surgical techniques developed for removing the epulis fissuratum lesions in order to improve alveolar ridge contour and improving adaptation of full prostheses. Most of these techniques can cause postoperative complications, such as oedema, pain, difficulty in swallowing and jaw movements, haemorrhage, infections and slow placement of final prostheses. The use of carbon dioxide (CO2) laser for the surgical removal of epulis lesions has resulted in many significant improvements including convenient mucosa removal, no bleeding or need for sutures, and minimal postoperative pain and oedema. This study is of 15 cases of removal of extensive epulis with vestibuloplasty in the maxilla and mandible that was carried out with CO2 laser, with no postoperative complications, rapid healing, and excellent aesthetic and functional outcome, all of which allowed for more rapid placement of final prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biooxidation of ferrous ion into ferric ion by Acidithiobacillus ferrooxidans can be potentially used for the removal of H2S from industrial gases. In this work, Fe3+ ions were obtained through the oxidation of Fe2+ using the LR strain of At. ferrooxidans immobilized in PVC stands in a pilot-scale bioreactor, while H2S was removed in an absorption tower equipped with Rasching rings. At. ferrooxidans LR strain cells were immobilized by inoculating the bacterium in a Fe2+-mineral medium and percolating it through the support. After complete Fe2+ oxidation, which took around 90 h, the reactor was washed several times with sulfuric acid (pH 1.7) before a new cycle was started. Four additional cycles using fresh Fe2+ mineral medium were then run. During these colonization cycles, the time required for complete iron oxidation decreased, dropping to about 60 h in the last cycle. The batch experiments in the H2S gas removal trials resulted in a gas removal rate of about 98-99% under the operational conditions employed. In the continuous experiments with the bioreactor coupled to the gas absorption column, a gas removal efficiency of almost 100% was reached after 500 min. Precipitate containing mainly sulfur formed during the experimental trial was identified by EDX. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study determined the size of aluminum oxide particles used in an air abrasion system that is able to remove carious dentin tissue with maximum preservation of sound structure. Thirty extracted and carious-free third molars were used in this study. The dentin sample was obtained by sectioning the middle of the crown longitudinal to the long axis of the tooth in a mesio-distal direction. One half of the crown corresponded to the sound dentin group (SD), while the other half was used to develop artificial caries, constituting the, carious dentin group (CD). The specimens were air abraded for 15 seconds. The SD and CD groups were each randomly divided into three subgroups (N=10) according to the particle diameter employed (27, 50 and 125 pm). The prepared cavity was perpendicularly cut in half, and the profiles of all hemi-fragments were observed using SEM microscopy. The cavity measurements were made using a modified cephalometric analysis. The 27, 50 and 125 pun aluminum oxide particles did not present selectivity in the removal of carious dentin. However, when using the air abrasive technique for carious dentin treatment, the use of 27 and 50 pun aluminum oxide particles is recommended, due to their capacity to remove less sound tissue than the 125 pun particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of sewage sludge in agricultural land as a means of sludge disposal and recycling has been shown to be economical and suitable because of the presence of nutrients such as nitrogen and phosphorus. However, municipal sludges often contain high quantities of toxic metals and other compounds that must be removed for its safe use in agricultural soils. The biological leaching of metals from sewage sludges has been shown to be a promising technique for metal detoxifying in such complex matrix. The process efficiency is dependent on several physico-chemical parameters, such as total solids concentration, metal forms, pH-ORP, and temperature. Scale-up of the process has not yet been defined and is still pursuing the correct operational design. Current research involving the bioleaching of metals from sewage sludge and its application to land, which affects soil physical properties, are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, an anisotropic nonlinear diffusion equation for image restoration is presented. The model has two terms: the diffusion and the forcing term. The balance between these terms is made in a selective way, in which boundary points and interior points of the objects that make up the image are treated differently. The optimal smoothing time concept, which allows for finding the ideal stop time for the evolution of the partial differential equation is also proposed. Numerical results show the proposed model's high performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multifractal analysis is now increasingly used to characterize soil properties as it may provide more information than a single fractal model. During the building of a large reservoir on the Parana River (Brazil), a highly weathered soil profile was excavated to a depth between 5 and 8 m. Excavation resulted in an abandoned area with saprolite materials and, in this area, an experimental field was established to assess the effectiveness of different soil rehabilitation treatments. The experimental design consisted of randomized blocks. The aim of this work was to characterize particle-size distributions of the saprolite material and use the information obtained to assess between-block variability. Particle-size distributions of the experimental plots were characterized by multifractal techniques. Ninety-six soil samples were analyzed routinely for particle-size distribution by laser diffractometry in a range of scales, varying from 0.390 to 2000 mu m. Six different textural classes (USDA) were identified with a clay content ranging from 16.9% to 58.4%. Multifractal models described reasonably well the scaling properties of particle-size distributions of the saprolite material. This material exhibits a high entropy dimension, D-1. Parameters derived from the left side (q > 0) of the f(alpha) spectra, D-1, the correlation dimension (D-2) and the range (alpha(0)-alpha(q+)), as well as the total width of the spectra (alpha(max) - alpha(min)) all showed dependence on the clay content. Sand, silt and clay contents were significantly different among treatments as a consequence of soil intrinsic variability. The D, and the Holder exponent of order zero, alpha(0), were not significantly different between treatments; in contrast, D-2 and several fractal attributes describing the width of the f(alpha) spectra were significantly different between treatments. The only parameter showing significant differences between sampling depths was (alpha(0) - alpha(q+)). Scale independent fractal attributes may be useful for characterizing intrinsic particle-size distribution variability. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)