976 resultados para AXIAL CHIRALITY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Tendon transfers and calcaneal osteotomies are commonly used to treat symptoms related to medial ankle arthrosis in fixed pes cavovarus. However, the relative effect of these osteotomies in terms of lateralizing the ground contact point of the hindfoot and redistributing ankle joint contact stresses are unknown. MATERIALS AND METHODS: Pes cavovarus with fixed hindfoot varus was simulated in eight cadaver specimens. The effect of three types of calcaneal osteotomies on the migration of the center of force and tibiotalar peak pressure at 300 N axial static load (half-body weight) were recorded using pressure sensors. RESULTS: A significant lateral shift of the center of force was observed: 4.9 mm for the laterally closing Z-shaped osteotomy with additional lateralization of the tuberosity, 3.4 mm for the lateral sliding osteotomy of the calcaneal tuberosity, and 2.7 mm for the laterally closing Z-shaped osteotomy (all p < 0.001). A significant peak pressure reduction was recorded: -0.53 MPa for the Z-shaped osteotomy with lateralization, -0.58 MPa for the lateral sliding osteotomy of the calcaneal tuberosity, and -0.41 MPa for the Z-shaped osteotomy (all p < 0.01). CONCLUSION: This cadaver study supports the hypothesis that lateralizing calcaneal osteotomies substantially help to normalize ankle contact stresses in pes cavovarus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Jasmonates are lipid mediators that control defence gene expression in response to wounding and other environmental stresses. These small molecules can accumulate at distances up to several cm from sites of damage and this is likely to involve cell-to-cell jasmonate transport. Also, and independently of jasmonate synthesis, transport and perception, different long-distance wound signals that stimulate distal jasmonate synthesis are propagated at apparent speeds of several cmmin(-1) to tissues distal to wounds in a mechanism that involves clade 3 GLUTAMATE RECEPTOR-LIKE (GLR) genes. A search for jasmonate synthesis enzymes that might decode these signals revealed LOX6, a lipoxygenase that is necessary for much of the rapid accumulation of jasmonic acid at sites distal to wounds. Intriguingly, the LOX6 promoter is expressed in a distinct niche of cells that are adjacent to mature xylem vessels, a location that would make these contact cells sensitive to the release of xylem water column tension upon wounding. We propose a model in which rapid axial changes in xylem hydrostatic pressure caused by wounding travel through the vasculature and lead to slower, radially dispersed pressure changes that act in a clade 3 GLR-dependent mechanism to promote distal jasmonate synthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Red blood cell (RBC) membrane fluctuations provide important insights into cell states. We present a spatial analysis of red blood cell membrane fluctuations by using digital holographic microscopy (DHM). This interferometric and dye-free technique, possessing nanometric axial and microsecond temporal sensitivities enables to measure cell membrane fluctuations (CMF) on the whole cell surface. DHM acquisition is combined with a model which allows extracting the membrane fluctuation amplitude, while taking into account cell membrane topology. Uneven distribution of CMF amplitudes over the RBC surface is observed, showing maximal values in a ring corresponding to the highest points on the RBC torus as well as in some scattered areas in the inner region of the RBC. CMF amplitudes of 35.9+/-8.9 nm and 4.7+/-0.5 nm (averaged over the cell surface) were determined for normal and ethanol-fixed RBCs, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To describe a new entity of congenital muscular dystrophies caused by de novo LMNA mutations. METHODS: Fifteen patients presenting with a myopathy of onset in the first year of life were subjected to neurological and genetic evaluation. Histopathological and immunohistochemical analyses were performed for all patients. RESULTS: The 15 patients presented with muscle weakness in the first year of life, and all had de novo heterozygous LMNA mutations. Three of them had severe early-onset disease, no motor development, and the rest experienced development of a "dropped head" syndrome phenotype. Despite variable severity, there was a consistent clinical pattern. Patients typically presented with selective axial weakness and wasting of the cervicoaxial muscles. Limb involvement was predominantly proximal in upper extremities and distal in lower extremities. Talipes feet and a rigid spine with thoracic lordosis developed early. Proximal contractures appeared later, most often in lower limbs, sparing the elbows. Ten children required ventilatory support, three continuously through tracheotomy. Cardiac arrhythmias were observed in four of the oldest patients but were symptomatic only in one. Creatine kinase levels were mild to moderately increased. Muscle biopsies showed dystrophic changes in nine children and nonspecific myopathic changes in the remaining. Markedly atrophic fibers were common, most often type 1, and a few patients showed positive inflammatory markers. INTERPRETATION: The LMNA mutations identified appear to correlate with a relatively severe phenotype. Our results further broaden the spectrum of laminopathies and define a new disease entity that we suggest is best classified as a congenital muscular dystrophy (LMNA-related congenital muscular dystrophy, or L-CMD).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tissue-engineered grafts for the urinary tract are being investigated for the potential treatment of several urologic diseases. These grafts, predominantly tubular-shaped, usually require in vitro culture prior to implantation to allow cell engraftment on initially cell-free scaffolds. We have developed a method to produce tubular-shaped collagen scaffolds based on plastic compression. Our approach produces a ready cell-seeded graft that does not need further in vitro culture prior to implantation. The tubular collagen scaffolds were in particular investigated for their structural, mechanical and biological properties. The resulting construct showed an especially high collagen density, and was characterized by favorable mechanical properties assessed by axial extension and radial dilation. Young modulus in particular was greater than non-compressed collagen tubes. Seeding densities affected proliferation rate of primary human bladder smooth muscle cells. An optimal seeding density of 10(6) cells per construct resulted in a 25-fold increase in Alamar blue-based fluorescence after 2 wk in culture. These high-density collagen gel tubes, ready seeded with smooth muscle cells could be further seeded with urothelial cells, drastically shortening the production time of graft for urinary tract regeneration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

(1R)-Normetanephrine is the natural stereoisomeric substrate for sulfotransferase 1A3 (SULT1A3)-catalyzed sulfonation. Nothing appears known on the enantioselectivity of the reaction despite its potential significance in the metabolism of adrenergic amines and in clinical biochemistry. We confronted the kinetic parameters of the sulfoconjugation of synthetic (1R)-normetanephrine and (1S)-normetanephrine by recombinant human SULT1A3 to a docking model of each normetanephrine enantiomer with SULT1A3 and the 3'-phosphoadenosine-5'-phosphosulfate cofactor on the basis of molecular modeling and molecular dynamics simulations of the stability of the complexes. The K(M) , V(max) , and k(cat) values for the sulfonation of (1R)-normetanephrine, (1S)-normetanephrine, and racemic normetanephrine were similar. In silico models were consistent with these findings as they showed that the binding modes of the two enantiomers were almost identical. In conclusion, SULT1A3 is not substrate-enantioselective toward normetanephrine, an unexpected finding explainable by a mutual adaptability between the ligands and SULT1A3 through an "induced-fit model" in the catalytic pocket. Chirality, 00:000-000, 2012.© 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A markedly elevated circulating CEA level was observed in January 1978 in a 40-year-old male patient who complained of functional digestive disorders consisting of 2-3 bowel movements at the end of each night. During follow-up of more than 3 years the CEA level was always found to be higher than 300 ng/ml as determined on 12 different blood samples using 3 different assays: the Hansen assay, our own inhibition radioimmunoassay performed on perchloric acid extract of serum, and a newly developed solid phase non-competitive enzyme immunoassay involving monoclonal anti-CEA antibody. The clinical evolution showed no aggravation of the persistent but mild bowel troubles, i.e. no real diarrhea or blood in the stool. The patient enjoys excellent general health and shows no weight loss. Barium enema, colonoscopy and extensive investigation by computerized axial tomography showed no evidence of primary or metastatic tumor. Apart from CEA, the blood chemistry was within normal limits. Six members of the patient's family have normal CEA levels. A possible explanation for this unique case of marked and persistent elevation of circulating CEA without evidence of cancer is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The purpose of this work was to demonstrate the normal ligamentous and tendinous anatomy of the intermetacarpal (IMC) and common carpometacarpal (CCMC) joints with MRI and MR arthrography. METHOD: MR images of 22 wrists derived from fresh human cadavers were obtained before and after arthrography. The MR imaging features of the ligaments and tendons about the CCMC and IMC joints and the joints themselves were analyzed in a randomized fashion and correlated with those seen on anatomic sections. RESULTS: Six CCMC ligaments were visualized. The dorsal and palmar CCMC ligaments and the pisometacarpal ligament were best visualized in the sagittal plane. The radial and ulnar CCMC collateral ligaments and the capito-third metacarpal ligament were best visualized in the coronal plane. Three main IMC ligaments were observed: a dorsal and a palmar ligament and an interosseous ligament complex. All three ligaments were best visualized in the axial plane. Four tendinous insertions to the metacarpal bases were evident. CONCLUSION: The anatomy of the ligaments and tendinous insertions about the second to fifth IMC and the CCMC joints is well demonstrated by MR imaging and MR arthrography. MR arthrography does not significantly improve the visualization of these complex structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Radiello Passive Air Sampler is one of the latest innovations developed for the sampling of pollutants in the air by passive headspace. It has been reported that its properties allow an enhanced sensitivity, reproducibility and adsorption capacity. It therefore appears to be of interest in the extraction of potential residues of ignitable liquids present in fire debris when arson is suspected. A theoretical approach and several laboratory tests have made it possible to precisely characterize in a forensic perspective the potential of the device in extracting and concentrating the vapors of ignitable liquids found in fire debris. Despite some advantages, the Radiello device appears to be less efficient than traditional axial symmetry samplers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fifty one patients with ankylosing spondylitis (AS) were typed for HLA-A, B, C, DR, and DQ antigens. The antigen frequencies were compared with those of a normal population and with a B27 positive control group. All but one of the patients with AS were HLA-B27 positive. A positive linkage disequilibrium between Cw1, Cw2, DR1, and the B27 antigen was observed. Patients with AS showed a significant increase in DQw2 antigen compared with the B27 positive control group. No differences in antigenic frequencies were observed in patients having peripheral arthritis and patients with only axial involvement. Seven out of nine patients (78%) with an erosive peripheral arthritis were DR7 positive, suggesting that DR7 or genes closely linked could be related with a more aggressive peripheral joint involvement in patients with AS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To investigate the differences in viscoelastic properties between normal and pathologic Achilles tendons ( AT Achilles tendon s) by using real-time shear-wave elastography ( SWE shear-wave elastography ). Materials and Methods The institutional review board approved this study, and written informed consent was obtained from 25 symptomatic patients and 80 volunteers. One hundred eighty ultrasonographic (US) and SWE shear-wave elastography studies of AT Achilles tendon s without tendonopathy and 30 studies of the middle portion of the AT Achilles tendon in patients with tendonopathy were assessed prospectively. Each study included data sets acquired at B-mode US (tendon morphology and cross-sectional area) and SWE shear-wave elastography (axial and sagittal mean velocity and relative anisotropic coefficient) for two passively mobilized ankle positions. The presence of AT Achilles tendon tears at B-mode US and signal-void areas at SWE shear-wave elastography were noted. Results Significantly lower mean velocity was shown in tendons with tendonopathy than in normal tendons in the relaxed position at axial SWE shear-wave elastography (P < .001) and in the stretched position at sagittal (P < .001) and axial (P = .0026) SWE shear-wave elastography . Tendon softening was a sign of tendonopathy in relaxed AT Achilles tendon s when the mean velocity was less than or equal to 4.06 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 54.2%; 95% confidence interval [ CI confidence interval ]: 32.8, 74.4; specificity, 91.5%; 95% CI confidence interval : 86.3, 95.1) and less than or equal to 5.70 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 41.7%; 95% CI confidence interval : 22.1, 63.3; specificity, 81.8%; 95% CI confidence interval : 75.3, 87.2) and in stretched AT Achilles tendon s, when the mean velocity was less than or equal to 4.86 m · sec(-1) at axial SWE shear-wave elastography (sensitivity, 66.7%; 95% CI confidence interval : 44.7, 84.3; specificity, 75.6%; 95% CI confidence interval : 68.5, 81.7) and less than or equal to 14.58 m · sec(-1) at sagittal SWE shear-wave elastography (sensitivity, 58.3%; 95% CI confidence interval : 36.7, 77.9; specificity, 83.5%; 95% CI confidence interval : 77.2, 88.7). Anisotropic results were not significantly different between normal and pathologic AT Achilles tendon s. Six of six (100%) partial-thickness tears appeared as signal-void areas at SWE shear-wave elastography . Conclusion Whether the AT Achilles tendon was relaxed or stretched, SWE shear-wave elastography helped to confirm and quantify pathologic tendon softening in patients with tendonopathy in the midportion of the AT Achilles tendon and did not reveal modifications of viscoelastic anisotropy in the tendon. Tendon softening assessed by using SWE shear-wave elastography appeared to be highly specific, but sensitivity was relatively low. © RSNA, 2014.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Clinical results of total ankle arthroplasty with early designs were disappointing. Recently-developed ankle prostheses have good mid-term results; however, limited information is available regarding effects of total ankle arthroplasty on ankle laxity. METHODS: Eight cadaveric lower extremities were tested with a custom device which enabled measurement of multi-axial forces, moments, and displacement during applied axial, shear, and rotational loading. Tests consisted of anterior-posterior and medial-lateral translation and internal-external rotation of the talus relative to the tibia during axial loads on the tibia simulating body weight (700 N) and an unloaded condition (5 N). Tests were performed in neutral, dorsiflexion, and plantarflexion. Laxity was determined for the intact ankle, and following insertion of an unconstrained total ankle implant, comparing load-displacement curve. FINDINGS: Laxity after total ankle arthroplasty did not approximate the normal ankle in most conditions tested. Displacement was significantly greater for total ankle arthroplasty in both posterior and lateral translation, and internal rotation, with 5 N axial loading, and anterior-posterior, medial-lateral translation, and internal-external rotation for 700 N axial loading. For the 700 N axial load condition, in the neutral ankle position, total anterior-posterior translation averaged 0.4 mm (SD 0.2 mm), but 6.0 mm (SD 1.5 mm) after total ankle arthroplasty (P<0.01). This study demonstrated more laxity in the replaced ankle than normal ankle for both unloaded and 700 N axially loaded conditions. INTERPRETATION: These data indicate the increased responsibility of the ligaments for ankle laxity after total ankle arthroplasty and suggest the importance of meticulous ligament reconstruction with total ankle arthroplasty operations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The centrifugal liquid membrane (CLM) cell has been utilized for chiroptical studies of liquid-liquid interfaces with a conventional circular dichroism (CD) spectropolarimeter. These studies required the characterization of optical properties of the rotating cylindrical CLM glass cell, which was used under the high speed rotation. In the present study, we have measured the circular and linear dichroism (CD and LD) spectra and the circular and linear birefringence (CB and LB) spectra of the CLM cell itself as well as those of porphyrine aggregates formed at the liquid-liquid interface in the CLM cell, applying Mueller matrix measurement method. From the results, it was confirmed that the CLM-CD spectra of the interfacial porphyrin aggregates observed by a conventional CD spectropolarimeter should be correct irrespective of LD and LB signals in the CLM cell.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the serendipitous discovery of ferrocene by Pauson and Kealy in 1951, it has become one of the most important structures in Organic Chemistry. Lately, kinetic resolution has emerged as a useful tool for the synthesis of planar chiral ferrocenes. This review aims to cover and discuss the development of this topic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.