968 resultados para 291801 Fluidization and Fluid Mechanics
Resumo:
This article presents improvement on a physical cardiovascular simulator (PCS) system. Intraventricular pressure versus intraventricular volume (PxV) loop was obtained to evaluate performance of a pulsatile chamber mimicking the human left ventricle. PxV loop shows heart contractility and is normally used to evaluate heart performance. In many heart diseases, the stroke volume decreases because of low heart contractility. This pathological situation must be simulated by the PCS in order to evaluate the assistance provided by a ventricular assist device (VAD). The PCS system is automatically controlled by a computer and is an auxiliary tool for VAD control strategies development. This PCS system is according to a Windkessel model where lumped parameters are used for cardiovascular system analysis. Peripheral resistance, arteries compliance, and fluid inertance are simulated. The simulator has an actuator with a roller screw and brushless direct current motor, and the stroke volume is regulated by the actuator displacement. Internal pressure and volume measurements are monitored to obtain the PxV loop. Left chamber internal pressure is directly obtained by pressure transducer; however, internal volume has been obtained indirectly by using a linear variable differential transformer, which senses the diaphragm displacement. Correlations between the internal volume and diaphragm position are made. LabVIEW integrates these signals and shows the pressure versus internal volume loop. The results that have been obtained from the PCS system show PxV loops at different ventricle elastances, making possible the simulation of pathological situations. A preliminary test with a pulsatile VAD attached to PCS system was made.
Resumo:
Rheumatoid arthritis (RA) is a chronic autoimmune inflammatory disease in which unknown arthrogenic autoantigen is presented to CD4+ T cells. The strong association of the disease with an epitope within the HLA-DR chain shared between various alleles of HLA-DR4 and DR1 emphasizes the importance of antigen presentation. This immune response predominantly occurs in the synovial tissue and fluid of the joints and autoreactive T cells are readily demonstrable in both the synovial compartment and blood. Circulating dendritic cells (DC) are phenotypically and functionally identical with normal peripheral blood (PB) DC. In the synovial tissue, fully differentiated perivascular DC are found in close association with T cells and with B cell follicles, sometimes containing follicular DC. These perivascular DC migrate across the activated endothelium from blood and receive differentiative signals within the joint from monocyte-derived cytokines and CD40-ligand+ T cells. In the SF, DC manifest an intermediate phenotype, similar to that of monocyte-derived DC in vitro. Like a delayed-type hypersensitivity response, the rheumatoid synovium represents an effector site. DC at many effector sites have a characteristic pattern of infiltration and differentiation. It is important to note that the effector response is not self-limiting in RA autoimmune inflammation. In this article, we argue that the presentation of self-antigen by DC and by autoantibody-producing B cells is critical for the perpetuation of the autoimmune response. Permanently arresting this ongoing immune response with either pharmaceutical agents or immunotherapy is a major challenge for immunology.
Resumo:
Background and objective: Tuberculosis (TB) and cancer are two of the main causes of pleural effusions which frequently share similar clinical features and pleural fluid profiles. This study aimed to identify diagnostic models based on clinical and laboratory variables to differentiate tuberculous from malignant pleural effusions. Methods: A retrospective study of 403 patients (200 with TB; 203 with cancer) was undertaken. Univariate analysis was used to select the clinical variables relevant to the models composition. Variables beta coefficients were used to define a numerical score which presented a practical use. The performances of the most efficient models were tested in a sample of pleural exudates (64 new cases). Results: Two models are proposed for the diagnosis of effusions associated with each disease. For TB: (i) adenosine deaminase (ADA), globulins and the absence of malignant cells in the pleural fluid; and (ii) ADA, globulins and fluid appearance. For cancer: (i) patient age, fluid appearance, macrophage percentage and presence of atypical cells in the pleural fluid; and (ii) as for (i) excluding atypical cells. Application of the models to the 64 pleural effusions showed accuracy higher than 85% for all models. Conclusions: The proposed models were effective in suggesting pleural tuberculosis or cancer.
Resumo:
Introduction. Lung transplantation has become the mainstay therapy for patients with end-stage lung disease refractory to medical management. However, the number of patients listed for lung transplantation largely exceeds available donors. The study of lung preservation requires accurate, cost-effective small animal models. We have described a model of ex vivo rat lung perfusion using a commercially available system. Methods. Male Wistar rats weighing 250 g-300 g were anesthetized with intraperitoneal sodium thiopental (50 mg/kg body weight). The surgical technique included heart-lung block extraction, assembly, and preparation for perfusion and data collection. We used an IL-2 Isolated Perfused Rat or Guinea Pig Lung System (Harvard Apparatus, Holliston, Mass, United States; Hugo Sachs Elektronik, Alemanha). Results. Preliminary results included hemodynamic and pulmonary mechanics data gathered in the experiments. Conclusion. The isolated rat lung perfusion system is a reliable method to assess lung preservation.
Resumo:
Positive end-expiratory pressure (PEEP) and sustained inspiratory insufflations (SI) during acute lung injury (ALI) are suggested to improve oxygenation and respiratory mechanics. We aimed to investigate the hemodynamic effects of PEEP with and without alveolar recruiting maneuver in a mild ALI model induced by inhalation of hydrochloric acid. Thirty-two pigs were randomly allocated into four groups (Control-PEEP, Control-SI, ALI-PEEP and ALI-SI). ALI was induced by intratracheal instillation of hydrochloric acid. PEEP values were progressively increased and decreased from 5, 10, 15 and 20 cmH(2)O in all groups. Three SIs maneuvers of 30 cmH(2)O for 20 s were applied to the assignable groups between each PEEP level. Transesophageal echocardiography (TEE), global hemodynamics, oxygenation indexes and gastric tonometry were measured 5 min after the maneuvers had been concluded and at each established value of PEEP (5, 10, 15 and 20 cmH(2)O). The cardiac index, ejection fraction and end-diastolic volume of right ventricle were significantly (P < 0.001) decreased with PEEP in both Control and ALI groups. Left ventricle echocardiography showed a significant decrease in end-diastolic volume at 20 cmH(2)O of PEEP (P < 0.001). SIs did not exert any significant hemodynamic effects either early (after 5 min) or late (after 3 h). In a mild ALI model induced by inhalation of hydrochloric acid, significant hemodynamic impairment characterized by cardiac function deterioration occurred during PEEP increment, but SI, probably due to low applied values (30 cmH(2)O), did not exert further negative hemodynamic effects. PEEP should be used cautiously in ALI caused by acid gastric content inhalation.
Resumo:
This case report describes the treatment of a patient with a Class II Division 1 subdivision right malocclusion with 8 congenitally missing teeth, incompetent lips, and incisor protrusion. The treatment plan included extractions and space closure with retraction of the anterior teeth; symmetric mechanics were used in the mandibular arch and asymmetric mechanics in the maxillary arch. Because of the mechanics used, some midline deviations were expected. Knowledge of diagnosis and treatment planning of asymmetric malocclusions and dental esthetics are essential for success when correcting asymmetic problems, but, even so, small clinical compromises should be expected. (Am J Orthod Dentofacial Orthop 2009; 135: 663-70)
Resumo:
A series of crown ether appended macrocyclic amines has been prepared comprising benzo-12-crown-4, benzo-15-crown-5, or benzo-18-crown-6 attached to a diamino-substituted cyclam. The Co-III complexes of these three receptors have been prepared and characterized spectroscopically and structurally. Crystal structures of each receptor in complex with an alkali metal ion and structures of the benzo-12-crown-4 and benzo-15-crown-5-receptors without guest ions are reported. 2D NMR and molecular mechanics modeling have been used to examine conformational variations upon guest ion complexation. Addition of cations to these receptors results in an appreciable anodic shift in the Co-III:II 11 redox potential, even in aqueous solution, but little cation selectivity is observed. Evidence for complex formation has been corroborated by Na-23 and Li-7 NMR spectroscopy and electrospray mass spectrometry.
Resumo:
Piston-cylinder experiments in the granite system demonstrate that a variety of isotopically distinct melts can arise from progressive melting of a single source. The relation between the isotopic composition of Sr and the stoichiometry of the observed melting reactions suggests that isotopic signatures of anatectic magmas can be used to infer melting reactions in natural systems. Our results also indicate that distinct episodes of dehydration and fluid-fluxed melting of a single, metapelitic source region may have contributed to the bimodal geochemistry of crustally derived leucogranites of the Himalayan orogen.
Resumo:
Water wetting is a crucial issue in carbon dioxide (CO.) corrosion of multiphase flow pipelines made from mild steel. This study demonstrates the use of a novel benchtop apparatus, a horizontal rotating cylinder, to study the effect of water wetting on CO2 corrosion of mild steel in two-phase flow. The setup is similar to a standard rotating cylinder except for its horizontal orientation and the presence of two phases-typically water and oil. The apparatus has been tested by using mass-transfer measurements and CO2 corrosion measurements in single-phase water flow. CO2 corrosion measurements were subsequently performed using a water/hexane mixture with water cuts varying between 5% and 50%. While the metal surface was primarily hydrophilic under stagnant. conditions, a variety of dynamic water wetting situations was encountered as the water cut and fluid velocity were altered. Threshold velocities were identified at various water cuts when the surface became oil-wet and corrosion stopped.
Resumo:
The aim of this study was to evaluate the response to the implantation of synthetic hydroxyapatite 30% (HAP-91®) in different physical states as dermal filler. Eighteen New Zealand rabbits were used, distributed randomly into two equal groups and then divided into three groups according to the postoperative period at 8, 21 and 49 days. One mL of HAP-91®, fluid and viscous, was implanted in the subcutaneous tissue, 1 cm proximal to the cranial crest of the right scapula. The thickness of the skin was measured before and after implantation and for the following 15 days. Pain sensitivity assessment was conducted, assigning the following scores: 0 - when the animal allowed the touch of the implant area and expressed no signs of pain; 1 - when the animal allowed the touch, but pain reaction occurred, like increase of the respiratory rate or attempt to escape; 2 - when the animal did not allow the touch to the implanted area. At 8, 21 and 49 days, biopsy of the implanted area was performed. No difference was observed between the thickness of the skin (p>0.05) and all animals received a score 0 for soreness. Histological analysis did not reveal any obvious inflammatory process, showing a predominance of mononuclear cells in samples of eight days and tissue organization around the biomaterial with a tendency to encapsulation. The results indicate that HAP-91®, both viscous and fluid, is biocompatible and suitable for dermal filling.
Resumo:
RESUMO: Objetivos – Determinar a sensibilidade e especificidade das ponderações Difusão (DWI) e T2 Fluid-Attenuated Inversion Recovery (FLAIR) na avaliação de lesões da substância branca (SB) e verificar em que medida se complementam, por forma a criar um conjunto de boas práticas na RM cranioencefálica de rotina. Metodologia – Recorrendo-se a uma metodologia quantitativa, efetuou-se uma análise retrospetiva da qual foram selecionados 30 pacientes, 10 sem patologia e 20 com patologia (2 com EM, 7 com Leucoencefalopatia, 6 com doença microangiopática e 5 com patologia da substância branca indefinida). Obteve-se uma amostra de 60 imagens, nomeadamente: 30 imagens ponderadas em DWI e 30 em T2 FLAIR. Recorrendo ao programa Viewdex®, três observadores avaliaram um conjunto de imagens segundo sete critérios: visibilidade, deteção, homogeneidade, localização, margens e dimensões da lesão e capacidade de diagnóstico. Com os resultados obtidos recorreu-se ao cálculo de sensibilidade e especificidade pelas Curvas ROC, bem como à análise estatística, nomeadamente, Teste-T, Índice de Concordância Kappa e coeficiente de correlação de Pearson entre as variáveis em estudo. Resultados – Os resultados de sensibilidade e de especificidade obtidos para a ponderação T2 FLAIR foram superiores (0,915 e 0,038, respetivamente) aos da ponderação DWI (0,08 e 0,100, respetivamente). Não se verificaram variâncias populacionais significativas. Obteve-se uma elevada correlação linear entre as variáveis com um valor r situado entre 0,8 e 0,99. Verificou-se também uma variabilidade considerável entre os observadores. Conclusões – Dados os baixos valores de sensibilidade e especificidade obtidos para a DWI, sugere-se que esta deva ser incluída no protocolo de rotina de crânio como auxiliar no diagnóstico diferencial com outras patologias.
Resumo:
Dissertação conducente à obtenção do grau de Mestre em Educação Social e Intervenção Comunitária, sob orientação do Professor Doutor Luís Manuel Costa Moreno
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Two clinical cases of patients who survived after numerous attacks of Africanized bees (600 and 1500 bee stings, respectively) are reported. Clinical manifestation was characterized by diffuse and widespread edema, a burning sensation in the skin, headache, weakness, dizziness, generalized paresthesia, somnolence and hypotension. Acute renal failure developed and was attributed to hypotension, intravascular hemolysis, myoglobinuria due to rhabdomyolysis and probably to direct toxic effect of the massive quantity of injected venom. They were treated with antihistaminic, corticosteroids and fluid infusion. One of them had severe acute renal failure and dialysis was required. No clinical complication was observed during hospital stay and complete renal function recovery was observed in both patients. In conclusion, acute renal failure after bee stings is probably due to pigment nephropathy associated with hypovolemia. Early recognition of this syndrome is crucial to the successful management of these patients.