1000 resultados para -0.3T


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This poster explains the changes introduced in the Web Content Accessibility Guidelines (WCAG) 2.0 from WCAG 1.0 and proposes a checklist for adapting existing websites. Finally, it describes the most common criticisms of the WCAG and places them in the context of its origin and initial aims.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquestes directrius expliquen com fer que el contingut web sigui accessible a persones ambdiscapacitats i s'adrecen a creadors de contingut (autors de pàgines web o dissenyadors de llocs web) ia creadors d'eines d'autor. L'objectiu principal d'aquestes directrius és promoure l'accessibilitat.Tanmateix, l'aplicació de les directrius facilitarà l'accés al contingut a tot tipus d'usuari, sigui quin siguil'agent d'usuari usat (navegador web, navegador de veu, telèfon mòbil, ordinador de cotxe, etc.) o les condicions de l'entorn de consulta (entorns sorollosos, espais mal il·luminats, entorns en què no es poden usar lesmans, etc.). L'aplicació d'aquestes directrius també ajudarà els usuaris a trobar la informació d'unamanera més ràpida dins el web. Les directrius no pretenen desincentivar l'ús d'imatges, vídeo, etc., sinóque expliquen com fer que el contingut multimèdia sigui més accessible a una àmplia audiència.Aquest és un document de referència per a uns principis d'accessibilitat i idees de disseny. Algunes deles estratègies comentades tracten d'aspectes relatius a la internacionalització del web i a l'accés desde terminals mòbils. Tanmateix, el document se centra en l'accessibilitat i no tracta exhaustivament delsaspectes relacionats amb altres activitats del W3C. Si voleu més informació sobre aquests temes podeuconsultar les pàgines inicials W3C Mobile Access Activity (per a l'accés des de terminals mòbils) i W3CInternationalization Activity (per als aspectes d'internacionalització). Aquest document està pensat per a ser estable en el temps i, per tant, no dóna informació específica sobre si els navegadors funcionen o no amb una determinada tecnologia, ja que aquesta informació varia molt ràpidament. Aquesta informació es pot trobar al web de la Web Accessibility Initiative ,WAI, (Iniciativa d'Accessibilitat Web) [WAI-UA-SUPPORT].Aquest document inclou un annex que organitza tots els punts de verificació ordenats per tema i perprioritat. Els punts de l'annex estan enllaçats a les respectives definicions en el document. Els temesrecollits en l'annex inclouen les imatges, el contingut multimèdia, les taules, els marcs, els formularis iels scripts. L'annex es presenta en forma de taula o com a simple llista. Un document a part, amb el títol Techniques for Web Content Accessibility Guidelines 1.0 (Tècniques per a les directrius per a l'accessibilitat al contingut web, versió 1.0) ([TECHNIQUES]) explica com posar a la pràctica els punts citats fins aquí. El document de tècniques explica cada punt amb més detalls i dóna exemples usant el llenguatge d'etiquetatge d'hipertext (HTML), fulls d'estil en cascada (CSS), el llenguatge d'integració multimèdia sincronitzada (SMIL) o el llenguatge d'etiquetatge matemàtic (MathML). Aquest document també inclou tècniques per a provar o validar una pàgina web i un índex Directrius per a l'accessibilitat al contingut web, versió 1.0 dels elements i atributs HTML amb les tècniques que els usen. El document de tècniques està pensat per a seguir de prop els canvis tecnològics i es preveu que s'actualitzi més sovint que les directrius.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the rheological properties of living human airway smooth muscle cells in culture and monitored the changes in rheological properties induced by exogenous stimuli. We oscillated small magnetic microbeads bound specifically to integrin receptors and computed the storage modulus (G') and loss modulus (G") from the applied torque and the resulting rotational motion of the beads as determined from their remanent magnetic field. Under baseline conditions, G' increased weakly with frequency, whereas G" was independent of the frequency. The cell was predominantly elastic, with the ratio of G" to G' (defined as eta) being ~0.35 at all frequencies. G' and G" increased together after contractile activation and decreased together after deactivation, whereas eta remained unaltered in each case. Thus elastic and dissipative stresses were coupled during changes in contractile activation. G' and G" decreased with disruption of the actin fibers by cytochalasin D, but eta increased. These results imply that the mechanisms for frictional energy loss and elastic energy storage in the living cell are coupled and reside within the cytoskeleton.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The distribution of Sn4+ cations within the five crystallographic sites of the magnetoplumbite (M) ‐like compound BaFe12−2xCoxSnxO19 has been analyzed using single‐crystal x‐ray‐diffraction data. The species Fe3+ and Co2+ cannot be distinguished using x rays because of their very similar atomic numbers; however, the calculation of the apparent valencies for the different sites allows an insight into the Co2+ cation segregation. The use of previous data from neutron powder diffraction allows a precise picture of the cation distribution, which indicates a pronounced site selectivity for both Sn4+ and Co2+ cations. The Sn4+ cations prefer the 4f2 sites and to a much lower extent the 12k sites, while they do not enter the octahedral 2a sites at all. Co2+ cations are distributed among tetrahedral and octahedral sites displaying a clear preference for the tetrahedral 4f1 sites. Magnetic measurements indicate that the compound still exhibits uniaxial anisotropy with the easy direction parallel to the c axis. Nevertheless, the magnetic structure shows a considerable degree of noncolinearity. A strong reduction of the magnetic anisotropy regarding that of the undoped compound is also detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the nonequilibrium behavior of the three-dimensional Gaussian random-field Ising model at T=0 in the presence of a uniform external field using a two-spin-flip dynamics. The deterministic, history-dependent evolution of the system is compared with the one obtained with the standard one-spin-flip dynamics used in previous studies of the model. The change in the dynamics yields a significant suppression of coercivity, but the distribution of avalanches (in number and size) stays remarkably similar, except for the largest ones that are responsible for the jump in the saturation magnetization curve at low disorder in the thermodynamic limit. By performing a finite-size scaling study, we find strong evidence that the change in the dynamics does not modify the universality class of the disorder-induced phase transition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Our objective is to test the hypothesis that coronary endothelial function (CorEndoFx) does not change with repeated isometric handgrip (IHG) stress in CAD patients or healthy subjects. BACKGROUND: Coronary responses to endothelial-dependent stressors are important measures of vascular risk that can change in response to environmental stimuli or pharmacologic interventions. The evaluation of the effect of an acute intervention on endothelial response is only valid if the measurement does not change significantly in the short term under normal conditions. Using 3.0 Tesla (T) MRI, we non-invasively compared two coronary artery endothelial function measurements separated by a ten minute interval in healthy subjects and patients with coronary artery disease (CAD). METHODS: Twenty healthy adult subjects and 12 CAD patients were studied on a commercial 3.0 T whole-body MR imaging system. Coronary cross-sectional area (CSA), peak diastolic coronary flow velocity (PDFV) and blood-flow were quantified before and during continuous IHG stress, an endothelial-dependent stressor. The IHG exercise with imaging was repeated after a 10 minute recovery period. RESULTS: In healthy adults, coronary artery CSA changes and blood-flow increases did not differ between the first and second stresses (mean % change ±SEM, first vs. second stress CSA: 14.8%±3.3% vs. 17.8%±3.6%, p = 0.24; PDFV: 27.5%±4.9% vs. 24.2%±4.5%, p = 0.54; blood-flow: 44.3%±8.3 vs. 44.8%±8.1, p = 0.84). The coronary vasoreactive responses in the CAD patients also did not differ between the first and second stresses (mean % change ±SEM, first stress vs. second stress: CSA: -6.4%±2.0% vs. -5.0%±2.4%, p = 0.22; PDFV: -4.0%±4.6% vs. -4.2%±5.3%, p = 0.83; blood-flow: -9.7%±5.1% vs. -8.7%±6.3%, p = 0.38). CONCLUSION: MRI measures of CorEndoFx are unchanged during repeated isometric handgrip exercise tests in CAD patients and healthy adults. These findings demonstrate the repeatability of noninvasive 3T MRI assessment of CorEndoFx and support its use in future studies designed to determine the effects of acute interventions on coronary vasoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To develop a breathhold method for black-blood viability imaging of the heart that may facilitate identifying the endocardial border. MATERIALS AND METHODS: Three stimulated-echo acquisition mode (STEAM) images were obtained almost simultaneously during the same acquisition using three different demodulation values. Two of the three images were used to construct a black-blood image of the heart. The third image was a T(1)-weighted viability image that enabled detection of hyperintense infarcted myocardium after contrast agent administration. The three STEAM images were combined into one composite black-blood viability image of the heart. The composite STEAM images were compared to conventional inversion-recovery (IR) delayed hyperenhanced (DHE) images in nine human subjects studied on a 3T MRI scanner. RESULTS: STEAM images showed black-blood characteristics and a significant improvement in the blood-infarct signal-difference to noise ratio (SDNR) when compared to the IR-DHE images (34 +/- 4.1 vs. 10 +/- 2.9, mean +/- standard deviation (SD), P < 0.002). There was sufficient myocardium-infarct SDNR in the STEAM images to accurately delineate infarcted regions. The extracted infarcts demonstrated good agreement with the IR-DHE images. CONCLUSION: The STEAM black-blood property allows for better delineation of the blood-infarct border, which would enhance the fast and accurate measurement of infarct size.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We use the recently obtained theoretical expression for the complete QCD static energy at next-to-next-to-next-to leading-logarithmic accuracy to determine r(0)Lambda((MS) over bar) by comparison with available lattice data, where r(0) is the lattice scale and Lambda((MS) over bar) is the QCD scale. We obtain r(0)Lambda((MS) over bar) = 0.622(-0.015)(+0.019) for the zero-flavor case. The procedure we describe can be directly used to obtain r(0)Lambda((MS) over bar) in the unquenched case, when unquenched lattice data for the static energy at short distances becomes available. Using the value of the strong coupling alpha(s) as an input, the unquenched result would provide a determination of the lattice scale r(0).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensive numerical studies of exact ground states of the two-dimensional ferromagnetic random field Ising model at T=0, with a Gaussian distribution of fields, are presented. Standard finite size scaling analysis of the data suggests the existence of a transition at ¿c=0.64±0.08. Results are compared with existing theories and with the study of metastable avalanches in the same model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the distribution of cross sections of clusters and the density-density correlation functions for the A+B¿0 reaction. We solve the reaction-diffusion equations numerically for random initial distributions of reactants. When both reactant species have the same diffusion coefficients the distribution of cross sections and the correlation functions scale with the diffusion length and obey superuniversal laws (independent of dimension). For different diffusion coefficients the correlation functions still scale, but the scaling functions depend on the dimension and on the diffusion coefficients. Furthermore, we display explicitly the peculiarities of the cluster-size distribution in one dimension.