737 resultados para screw loosening


Relevância:

10.00% 10.00%

Publicador:

Resumo:

An extrusion die is used to continuously produce parts with a constant cross section; such as sheets, pipes, tire components and more complex shapes such as window seals. The die is fed by a screw extruder when polymers are used. The extruder melts, mixes and pressures the material by the rotation of either a single or double screw. The polymer can then be continuously forced through the die producing a long part in the shape of the die outlet. The extruded section is then cut to the desired length. Generally, the primary target of a well designed die is to produce a uniform outlet velocity without excessively raising the pressure required to extrude the polymer through the die. Other properties such as temperature uniformity and residence time are also important but are not directly considered in this work. Designing dies for optimal outlet velocity variation using simple analytical equations are feasible for basic die geometries or simple channels. Due to the complexity of die geometry and of polymer material properties design of complex dies by analytical methods is difficult. For complex dies iterative methods must be used to optimize dies. An automated iterative method is desired for die optimization. To automate the design and optimization of an extrusion die two issues must be dealt with. The first is how to generate a new mesh for each iteration. In this work, this is approached by modifying a Parasolid file that describes a CAD part. This file is then used in a commercial meshing software. Skewing the initial mesh to produce a new geometry was also employed as a second option. The second issue is an optimization problem with the presence of noise stemming from variations in the mesh and cumulative truncation errors. In this work a simplex method and a modified trust region method were employed for automated optimization of die geometries. For the trust region a discreet derivative and a BFGS Hessian approximation were used. To deal with the noise in the function the trust region method was modified to automatically adjust the discreet derivative step size and the trust region based on changes in noise and function contour. Generally uniformity of velocity at exit of the extrusion die can be improved by increasing resistance across the die but this is limited by the pressure capabilities of the extruder. In optimization, a penalty factor that increases exponentially from the pressure limit is applied. This penalty can be applied in two different ways; the first only to the designs which exceed the pressure limit, the second to both designs above and below the pressure limit. Both of these methods were tested and compared in this work.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research focused on the to modification of the surface structure of titanium implants with nanostructured morphology of TiO2 nanotubes and studied the interaction of nanotubes with osteoblast cells to understand the parameters that affect the cell growth. The electrical, mechanical, and structural properties of TiO2 nanotubes were characterized to establish a better understanding on the properties of such nanoscale morphological structures. To achieve the objectives of this research work I transformed the titanium and its alloys, either in bulk sheet form, bulk machined form, or thin film deposited on another substrate into a surface of titania nanotubes using a low cost and environmentally friendly process. The process requires only a simple electrolyte, low cost electrode, and a DC power supply. With this simple approach of scalable nanofabrication, a typical result is nanotubes that are each approximately 100nm in diameter and have a wall thickness of about 20nm. By changing the fabrication parameters, independent nanotubes can be fabricated with open volume between them. Titanium in this form is termed onedimensional since electron transport is narrowly confined along the length of the nanotube. My Ph.D. accomplishments have successfully shown that osteoblast cells, the cells that are the precursors to bone, have a strong tendency to attach to the inside and outside of the titanium nanotubes onto which they are grown using their filopodia – cell’s foot used for locomotion – anchored to titanium nanotubes. In fact it was shown that the cell prefers to find many anchoring sites. These sites are critical for cell locomotion during the first several weeks of maturity and upon calcification as a strongly anchored bone cell. In addition I have shown that such a surface has a greater cell density than a smooth titanium surface. My work also developed a process that uses a focused and controllably rastered ion beam as a nano-scalpel to cut away sections of the osteoblast cells to probe the attachment beneath the main cell body. Ultimately the more rapid growth of osteoblasts, coupled with a stronger cell-surface interface, could provide cost reduction, shorter rehabilitation, and fewer follow-on surgeries due to implant loosening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates the results of a technique using an extensor carpi radialis longus (ECRL) tenodesis for symptomatic scapholunate instability. Symptomatic scapholunate instability has been corrected so far either by limited wrist fusion or by various techniques of soft tissue repair. Limited wrist fusion greatly reduces wrist motion and increases the probability of osteoarthritis in the remaining mobile wrist segments. On the other hand, most types of soft tissue repair are technically difficult to perform and have disappointing results due to the inherent laxity. The presented dynamic approach was used in 20 wrists of 19 patients with static scapholunate instability. Preoperative evaluation included in all patients clinical examination, radiologic evaluation, and arthroscopy for establishing the diagnosis of static scapholunate instability. The technique involves the fixation of the ECRL tendon on the dorsal aspect of the scaphoid by means of a cancellous screw and a special washer. Dynamic ECRL tenodesis of the scaphoid is a safe and simple procedure that enhances the extension forces on the scaphoid in all wrist positions. The results of this preliminary report in 20 wrists showed dynamic ECRL tenodesis to be an effective treatment option for treating symptomatic static scapholunate instability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In severe forms of ocular surface disorders keratoprostheses provide the ultimate possibility to restore vision. They are made of an optical cylinder integrated with a supporting biocompatible or biological haptic. CASE REPORT: We report on two patients with different types of keratoprostheses. An 88-year-old woman with ocular pemphigoid received in 1970 a bilateral osteo-odonto-keratoprosthesis (Strampelli). A 59-year-old man with refractory corneal ulcer after corneal grafting received in 2003 a keratoprosthesis with supporting Dacron tissue (Pintucci). RESULTS: The course 35 years after implantation of the osteo-odonto-keratoprosthesis was uneventful. Histologically there were no signs of loosening, rejection or infection. The autologous dentin, which was used for the fixation, was still present. The eye with the Dacron fixated prosthesis (Pintucci) had to be enucleated due to a loosening with endophthalmitis one and a half year after implantation. CONCLUSIONS: Keratoprostheses with autologous fixation often show good long-term results. On the other hand, prostheses with synthetic material are more often complicated by dislocation and inflammation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Anatomic reduction and stable fixation by means of tissue- preserving surgical approaches. INDICATIONS Displaced acetabular fractures. Surgical hip dislocation approach with larger displacement of the posterior column in comparison to the anterior column, transtectal fractures, additional intraarticular fragments, marginal impaction. Stoppa approach with larger displacement of the anterior column in comparison to the posterior column. A combined approach might be necessary with difficult reduction. CONTRAINDICATIONS Fractures > 15 days (then ilioinguinal or extended iliofemoral approaches). Suprapubic catheters and abdominal problems (e.g., previous laparotomy due to visceral injuries) with Stoppa approach (then switch to classic ilioinguinal approach). SURGICAL TECHNIQUE: Surgical hip dislocation: lateral decubitus position. Straight lateral incision centered over the greater trochanter. Entering of the Gibson interval. Digastric trochanteric osteotomy with protection of the medial circumflex femoral artery. Opening of the interval between the piriformis and the gluteus minimus muscle. Z-shaped capsulotomy. Dislocation of the femoral head. Reduction and fixation of the posterior column with plate and screws. Fixation of the anterior column with a lag screw in direction of the superior pubic ramus. Stoppa approach: supine position. Incision according to Pfannenstiel. Longitudinal splitting of the anterior portion of the rectus sheet and the rectus abdominis muscle. Blunt dissection of the space of Retzius. Ligation of the corona mortis, if present. Blunt dissection of the quadrilateral plate and the anterior column. Reduction of the anterior column and fixation with a reconstruction plate. Fixation of the posterior column with lag screws. If necessary, the first window of the ilioinguinal approach can be used for reduction and fixation of the posterior column. POSTOPERATIVE MANAGEMENT: During hospital stay, intensive mobilization of the hip joint using a continuous passive motion machine with a maximum flexion of 90 degrees . No active abduction and passive adduction over the body's midline, if a surgical dislocation was performed. Maximum weight bearing 10-15 kg for 8 weeks. Then, first clinical and radiographic follow-up. Deep venous thrombosis prophylaxis for 8 weeks postoperatively. RESULTS: 17 patients with a mean follow-up of 3.2 years. Ten patients were operated via surgical hip dislocation, two patients with a Stoppa approach, and five using a combined or alternative approach. Anatomic reduction was achieved in ten of the twelve patients (83%) without primary total hip arthroplasty. Mean operation time 3.3 h for surgical hip dislocation and 4.2 h for the Stoppa approach. Complications comprised one delayed trochanteric union, one heterotopic ossification, and one loss of reduction. There were no cases of avascular necrosis. In two patients, a total hip arthroplasty was performed due to the development of secondary hip osteoarthritis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim of this prospective case series study was to evaluate the short-term success rates of titanium screw-type implants with a chemically modified sand-blasted and acid-etched (mod SLA) surface after 3 weeks of healing. MATERIAL AND METHODS: A total of 56 implants were inserted in the posterior mandible of 40 partially edentulous patients exhibiting bone densities of class I to III. After a healing period of 3 weeks, all implants were functionally loaded with a screw-retained crown or fixed dental prosthesis. The patients were recalled at weeks 4, 7, 12, and 26 for monitoring and assessment of clinical and radiological parameters, including implant stability quotient (ISQ) measurements. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants including the "spinners" showed favorable clinical and radiographic findings at the 6-month follow-up examination. The ISQ values increased steadily throughout the follow-up period. At the time of implant placement, the range of ISQ values exhibited a mean of 74.33, and by week 26, a mean value of 83.82 was recorded. Based on strict criteria, all 56 implants were considered successfully integrated, resulting in a 6-month survival and success rate of 100.0%. CONCLUSION: This prospective study using an early-loading protocol after 3 weeks of healing demonstrated that titanium implants with the modified SLA surface can achieve and maintain successful tissue integration over a period of at least 6 months. The ISQ method seems feasible to monitor implant stability during the initial wound-healing period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To systematically appraise the impact of mechanical/technical risk factors on implant-supported reconstructions. MATERIAL AND METHODS: A MEDLINE (PubMed) database search from 1966 to April 2008 was conducted. The search strategy was a combination of MeSH terms and the key words: design, dental implant(s), risk, prosthodontics, fixed prosthodontics, fixed partial denture(s), fixed dental prosthesis (FDP), fixed reconstruction(s), oral rehabilitation, bridge(s), removable partial denture(s), overdenture(s). Randomized controlled trials, controlled trials, and prospective and retrospective cohort studies with a mean follow-up of at least 4 years were included. The material evaluated in each study had to include cases with/without exposure to the risk factor. RESULTS: From 3,568 articles, 111 were selected for full text analysis. Of the 111 articles, 33 were included for data extraction after grouping the outcomes into 10 risk factors: type of retentive elements supporting overdentures, presence of cantilever extension(s), cemented versus screw-retained FDPs, angled/angulated abutments, bruxism, crown/implant ratio, length of the suprastructure, prosthetic materials, number of implants supporting an FDP, and history of mechanical/technical complications. CONCLUSIONS: The absence of a metal framework in overdentures, the presence of cantilever extension(s) > 15 mm and of bruxism, the length of the reconstruction, and a history of repeated complications were associated with increased mechanical/technical complications. The type of retention, the presence of angled abutments, the crown-implant ratio, and the number of implants supporting an FDP were not associated with increased mechanical/technical complications. None of the mechanical/technical risk factors had an impact on implant survival and success rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This case report presents the treatment sequence of a 56 years old patient after he developed periimplantitis at the implant in position of tooth 22. This implant was integrated in an overdenture reconstruction connected to a soldered screw retained gold bar. The entire 2-stage procedure of implant explantation, simultaneous bone augmentation and new implant placement is documented. The onlay-graft was performed by means of the Transfer-Ring-Control System (Meisinger). The existing gold bar could be resoldered and adapted to the new implant. Accordingly the overdenture was relined and the female retainer mounted. The treatment period covered almost one year.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prosthetic and osteosynthetic implants from metal alloys will be indispensable in orthopedic surgery, as long as tissue engineering and biodegradable bone substitutes do not lead to products that will be applied in clinical routine for the repair of bone, cartilage, and joint defects. Therefore, the elucidation of the interactions between the periprosthetic tissues and the implant remains of clinical relevance and several factors are known to affect the longevity of implants. Within this study, the effects of metal particles and surface topography on the recruitment of osteoclasts was investigated in vitro in a coculture of osteoblasts and bone marrow cells. The cells were grown in the presence of particles of different sizes and chemical composition or on metal discs with polished or sandblasted surfaces, respectively. At the end of the culture, newly formed osteoclasts were counted. Osteoclastogenesis was reduced when particles were added directly to the coculture. The effect depended on the size of the particles, small particles exerting stronger effects than larger ones. The chemical composition of the particles, however, did not affect the development of osteoclasts. In cocultures grown on sandblasted surfaces, osteoclasts developed at higher rates than they did in cultures on polished surfaces. The data demonstrate that wear particles and implant surfaces affect osteoclastogenesis and thus may be involved in the induction of local bone resorption and the formation of osteolytic lesions, leading eventually to the loosening of orthopedic implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A general, two-step highly efficient synthesis of 1,2-diaryl-, 1,2,3-triaryl- and 1,2,3,4-tetraarylbenzenes from simple stitching of alpha-oxo-ketene-S,S-acetals and active methylene compounds via a ‘lactone intermediate’ is described. This procedure offers easy access to highly functionalized arylated-benzenes containing sterically demanding groups in good to excellent yields. The novelty of the procedure lies in the fabrication of aromatic compounds with desired conformational flexibility along the molecular axis in a transition metal-free environment through easily accessible precursors. The crystal analysis of these arylated-benzene scaffolds showed that the peripheral aryl rings are arranged in propeller-like fashion with respect to the central benzene rings. Examination of the crystal packing in the structure of a 1,2,3,4-tetraarylbenzene 12c revealed a “N…pi interaction” between molecules related by a two-fold screw axis running in a direction. It is interesting that the repeat of the array of N…pi interaction around the axis of the 1,2,3,4-tetraarylbenzene 12c enforces the molecules in a helical pattern.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Es werden Auslegungsverfahren für vertikale und horizontale bis leicht geneigte Hochleistungs-Schneckenförderer vorgestellt, die eine anwendbare und praxistaugliche Möglichkeit sind, solche Fördergeräte für den täglichen Einsatz im Massengutumschlag auszulegen. Die Verifikation des Auslegungsverfahrens für vertikale Schneckenförderer durch Leistungsmessungen an zwei Referenzanlagen hat gezeigt, dass sich die im industriellen Einsatz befindlichen Anlagen mit guten Ergebnissen durch das Berechnungsverfahren nachrechnen lassen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pedicle hooks which are used as an anchorage for posterior spinal instrumentation may be subjected to considerable three-dimensional forces. In order to achieve stronger attachment to the implantation site, hooks using screws for additional fixation have been developed. The failure loads and mechanisms of three such devices have been experimentally determined on human thoracic vertebrae: the Universal Spine System (USS) pedicle hook with one screw, a prototype pedicle hook with two screws and the Cotrel-Dubousset (CD) pedicle hook with screw. The USS hooks use 3.2-mm self-tapping fixation screws which pass into the pedicle, whereas the CD hook is stabilised with a 3-mm set screw pressing against the superior part of the facet joint. A clinically established 5-mm pedicle screw was tested for comparison. A matched pair experimental design was implemented to evaluate these implants in constrained (series I) and rotationally unconstrained (series II) posterior pull-out tests. In the constrained tests the pedicle screw was the strongest implant, with an average pull-out force of 1650 N (SD 623 N). The prototype hook was comparable, with an average failure load of 1530 N (SD 414 N). The average pull-out force of the USS hook with one screw was 910 N (SD 243 N), not significantly different to the CD hook's average failure load of 740 N (SD 189 N). The result of the unconstrained tests were similar, with the prototype hook being the strongest device (average 1617 N, SD 652 N). However, in this series the difference in failure load between the USS hook with one screw and the CD hook was significant. Average failure loads of 792 N (SD 184 N) for the USS hook and 464 N (SD 279 N) for the CD hook were measured. A pedicular fracture in the plane of the fixation screw was the most common failure mode for USS hooks.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die lösbare Verbindung von mechanischen Komponenten innerhalb von Maschinen und Anlagen wird zumeist über Schraubverbindungen realisiert. Um eine ausreichende Verbindung zu erzielen werden derzeit die Klemmkräfte durch ein definiertes Anzugsmoment aufgebracht. Bei der Berechnung des Momentes entsprechend der benötigten Kraft finden Reibbeiwerte innerhalb der Schraubverbindung Berücksichtigung, welche nur bedingt ermittelt werden können. In kritischen Maschinenkomponenten wird daher eine Überdimensionierung der Schrauben zur Erhöhung der Sicherheit akzeptiert. Die direkte Kraftmessung mittels einer intelligenten Unterlegscheibe und eine transpondergestützte Datenübertragung ermöglicht es, die Kräfte genau einzustellen und somit die Sicherheit zu erhöhen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Plant cell expansion is controlled by a fine-tuned balance between intracellular turgor pressure, cell wall loosening and cell wall biosynthesis. To understand these processes, it is important to gain in-depth knowledge of cell wall mechanics. Pollen tubes are tip-growing cells that provide an ideal system to study mechanical properties at the single cell level. With the available approaches it was not easy to measure important mechanical parameters of pollen tubes, such as the elasticity of the cell wall. We used a cellular force microscope (CFM) to measure the apparent stiffness of lily pollen tubes. In combination with a mechanical model based on the finite element method (FEM), this allowed us to calculate turgor pressure and cell wall elasticity, which we found to be around 0.3 MPa and 20–90 MPa, respectively. Furthermore, and in contrast to previous reports, we showed that the difference in stiffness between the pollen tube tip and the shank can be explained solely by the geometry of the pollen tube. CFM, in combination with an FEM-based model, provides a powerful method to evaluate important mechanical parameters of single, growing cells. Our findings indicate that the cell wall of growing pollen tubes has mechanical properties similar to rubber. This suggests that a fully turgid pollen tube is a relatively stiff, yet flexible cell that can react very quickly to obstacles or attractants by adjusting the direction of growth on its way through the female transmitting tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The removal of nonretrievable implant components represents a challenge in implant dentistry. The mechanical approach involves the risk of damaging the implant connection or the bone-to-implant interface. This case report describes a cryo-mechanical approach for the safe removal of a nonretrievable implant component. A patient had an implant surgically placed in a private practice. When the patient returned to the restorative dentist to make a definitive impression, the healing abutment could not be loosened. The patient was referred to the Division of Fixed Prosthodontics (University of Bern, Switzerland), where the stripped screw hole was enlarged with a special drill from a service kit of the implant provider. Although an extraction bolt was screwed into the opening and the torque ratchet was activated, the healing abutment would not loosen. A novel approach was attempted whereby the healing abutment was cooled with dry ice (CO2). The cooling effect seemingly caused shrinkage of the healing abutment and a reduction of the connection forces between the implant and the nonretrievable component. The approach of creating an access hole for the application of reverse torque via the extraction bolt in combination with the thermal effect led to the successful removal of the blocked component. Neither the implant connection nor the bone-to-implant interface was damaged. The combined cryo-mechanical procedure allowed the implant to be successfully restored.