986 resultados para return water heating
Resumo:
Since long ago cellulosic lyotropic liquid crystals were thought as potential materials to produce fibers competitive with spidersilk or Kevlar, yet the processing of high modulus materials from cellulose-based precursors was hampered by their complex rheological behavior. In this work, by using the Rheo-NMR technique, which combines deuterium NMR with rheology, we investigate the high shear rate regimes that may be of interest to the industrial processing of these materials. Whereas the low shear rate regimes were already investigated by this technique in different works [1-4], the high shear rates range is still lacking a detailed study. This work focuses on the orientational order in the system both under shear and subsequent relaxation process arising after shear cessation through the analysis of deuterium spectra from the deuterated solvent water. At the analyzed shear rates the cholesteric order is suppressed and a flow-aligned nematic is observed which for the higher shear rates develops after certain time periodic perturbations that transiently annihilate the order in the system. During relaxation the flow aligned nematic starts losing order due to the onset of the cholesteric helices leading to a period of very low order where cholesteric helices with different orientations are forming from the aligned nematic, followed in the final stage by an increase in order at long relaxation times corresponding to the development of aligned cholesteric domains. This study sheds light on the complex rheological behavior of chiral nematic cellulose-based systems and opens ways to improve its processing. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
This work evaluates the possibility of using spent coffee grounds (SCG) for biodiesel production and other applications. An experimental study was conducted with different solvents showing that lipid content up to 6 wt% can be obtained from SCG. Results also show that besides biodiesel production, SCG can be used as fertilizer as it is rich in nitrogen, and as solid fuel with higher heating value (HHV) equivalent to some agriculture and wood residues. The extracted lipids were characterized for their properties of acid value, density at 15 °C, viscosity at 40 °C, iodine number, and HHV, which are negatively influenced by water content and solvents used in lipid extraction. Results suggest that for lipids with high free fatty acids (FFA), the best procedure for conversion to biodiesel would be a two-step process of acid esterification followed by alkaline transesterification, instead of a sole step of direct transesterification with acid catalyst. Biodiesel was characterized for its properties of iodine number, acid value, and ester content. Although these quality parameters were not within the limits of NP EN 14214:2009 standard, SCG lipids can be used for biodiesel, blended with higher-quality vegetable oils before transesterification, or the biodiesel produced from SCG can be blended with higher-quality biodiesel or even with fossil diesel, in order to meet the standard requirements.
Resumo:
Master Thesis to obtain the Master degree in Chemical Engineering - Branch Chemical Processes
Resumo:
This paper presents an optimization study of a distillation column for methanol and aqueous glycerol separation in a biodiesel production plant. Considering the available physical data of the column configuration, a steady state model was built for the column using Aspen-HYSYS as process simulator. Several sensitivity analysis were performed in order to better understand the relation between the variables of the distillation process. With the information obtained by the simulator, it is possible to define the best range for some operational variables that maintain composition of the desired product under specifications and choose operational conditions to minimize energy consumptions.
Resumo:
Mestrado em Engenharia Mecânica – Ramo Energia
Resumo:
Dissertation submitted to obtain a Ph.D. (Doutoramento) degree in Biology at the Instituto de Tecnologia Química e Biológica da Universidade Nova de Lisboa
Resumo:
A presente dissertação centrou-se no estudo técnico-económico de dois cenários futuros para a continuação de fornecimento de energia térmica a um complexo de piscinas existente na região do vale do Tâmega. Neste momento a central de cogeração existente excedeu a sua licença de utilização e necessita de ser substituída. Os dois cenários em estudo são a compra de uma nova caldeira, a gás natural, para suprir as necessidades térmicas da caldeira existente a fuelóleo, ou o uso de um sistema de cogeração compacto que poderá estar disponível numa empresa do grupo. No primeiro cenário o investimento envolvido é cerca de 456 640 € sem proveitos de outra ordem para além dos requisitos térmicos, mas no segundo cenário os resultados são bem diferentes, mesmo que tenha de ser realizado o investimento de 1 000 000 € na instalação. Para este cenário foi efetuado um levantamento da legislação nacional no que toca à cogeração, recolheram-se dados do edifício como: horas de funcionamento, número de utentes, consumos de energia elétrica, térmica, água, temperatura da água das piscinas, temperatura do ar da nave, assim como as principais características da instalação de cogeração compacta. Com esta informação realizou-se o balanço de massa e energia e criou-se um modelo da nova instalação em software de modelação processual (Aspen Plus® da AspenTech). Os rendimentos térmico e elétrico obtidos da nova central de cogeração compacta foram, respetivamente, de 38,1% e 39,8%, com uma percentagem de perdas de 12,5% o que determinou um rendimento global de 78%. A avaliação da poupança de energia primária para esta instalação de cogeração compacta foi de 19,6 % o que permitiu concluir que é de elevada eficiência. O modelo criado permitiu compreender as necessidades energéticas, determinar alguns custos associados ao processo e simular o funcionamento da unidade com diferentes temperaturas de ar ambiente (cenários de verão e inverno com temperaturas médias de 20ºC e 5ºC). Os resultados revelaram uma diminuição de 1,14 €/h no custo da electricidade e um aumento do consumo de gás natural de 62,47 €/h durante o período mais frio no inverno devido ao aumento das perdas provocadas pela diminuição da temperatura exterior. Com esta nova unidade de cogeração compacta a poupança total anual pode ser, em média, de 267 780 € admitindo um valor para a manutenção de 97 698 €/ano. Se assim for, o projeto apresenta um retorno do investimento ao fim de 5 anos, com um VAL de 1 030 430 € e uma taxa interna de rentabilidade (TIR) de 14% (positiva, se se considerar a taxa de atualização do investimento de 3% para 15 anos de vida). Apesar do custo inicial ser elevado, os parâmetros económicos mostram que o projeto tem viabilidade económica e dará lucro durante cerca de 9 anos.
Resumo:
Em Portugal existem muitos espaços comerciais e industriais em que as necessidades térmicas de arrefecimento são muito superiores às necessidades de aquecimento devido aos ganhos internos que advêm da existência de equipamentos e da iluminação dos edifícios, assim como, da presença das pessoas. A instalação de sistemas convencionais de ar condicionado para espaços comerciais e industriais de grande dimensão está geralmente associada ao transporte de grandes caudais de ar, e consequentemente, a elevados consumos de energia primária, e também, elevados custos de investimento, de manutenção e de operação. O arrefecedor evaporativo é uma solução de climatização com elevada eficiência energética, cujo princípio de funcionamento promove a redução do consumo de energia primária nos edifícios. A metodologia utilizada baseou-se na criação de uma ferramenta informática de simulação do funcionamento de um protótipo de um arrefecedor evaporativo. Foi efetuada a modelação matemática das variáveis dinâmicas envolvidas, dos processos de transferência de calor e de massa, assim como dos balanços de energia que ocorrem no arrefecedor evaporativo. A ferramenta informática desenvolvida permite o dimensionamento do protótipo do arrefecedor evaporativo, sendo determinadas as caraterísticas técnicas (potência térmica, caudal, eficiência energética, consumo energético e consumo e água) de acordo com o tipo de edifício e com as condições climatéricas do ar exterior. Foram selecionados três dimensionamentos de arrefecedores evaporativos, representativos de condições reais de uma gama baixa, média e elevada de caudais de ar. Os resultados obtidos nas simulações mostram que a potência de arrefecimento (5,6 kW, 16,0 kW e 32,8 kW) e o consumo de água (8 l/h, 23,9 l/h e 48,96 l/h) aumentam com o caudal de ar do arrefecedor, 5.000 m3/h, 15.000 m3/h e 30.000 m3/h, respetivamente. A eficácia de permuta destes arrefecedores evaporativos, foi de 69%, 66% e 67%, respetivamente. Verificou-se que a alteração de zona climática de V1 para V2 implicou um aumento de 39% na potência de arrefecimento e de 20% no consumo de água, e que, a alteração de zona climática de V2 para V3 implicou um aumento de 39% na potência de arrefecimento e de 39% no consumo de água. O arrefecedor evaporativo apresenta valores de consumo de energia elétrica entre 40% a 80% inferiores aos dos sistemas de arrefecimento convencionais, sendo este efeito mais intenso quando a zona climática de verão se torna mais severa.
Resumo:
Leishmania braziliensis is a causative agent of American Cutaneous Leishmaniasis (ACL). The 034-JCG strain, isolated from a patient from the northern region of Paraná State, Brazil, was cultivated in Blood Agar Base medium, lyophilized and submitted to phenol-water extraction. The extract was treated with RNase I. The carbohydrate containing-antigen (Ag-CHO) was immunogenic to rabbits and showed at least a fraction with some negative charge at pH 8.2. This antigen showed cross-reactivity with the phenol-water extract of the growth medium used for the culture of promastigotes and with the surface antigens of promastigotes. Its composition is: 24.3% of total sugars, from which 11.2% of galactose, 7.5% of mannose and 5.6% of ribose. Protein content was 5.4% and phosphate 18.5%. The antigenic activity was maintained after: repeated freezing-thawing; lyophilization; heating at 100ºC for 30 minutes; treatment with RNase, trichloroacetic acid and sodium metaperiodate. The precipitin line obtained is Periodic Acid Schiff positive. The application of the Ag-CHO in counterimmunoelectrophoresis reaction for the immunodiagnosis of ACL showed 60% sensitivity, and no cross-reaction with the five sera of Chagas' disease patients tested. The use of this antigen in a more sensitive technique, with more samples of sera, may improve these results.
Resumo:
A reabilitação é uma intervenção que confere ao edifício uma qualidade superior à que possuía aquando da sua construção. Desta forma, e com a entrada em vigor em final de 2013 da nova legislação referente à certificação energética dos edifícios, surge novamente o interesse na temática de reabilitar energeticamente o parque habitacional. Esta nova legislação aparece na sequencia das novas exigências da Comissão Europeia e do Parlamento Europeu face às alterações climáticas e consequentemente, em relação à eficiência energética. A reabilitação energética de edifícios, visa principalmente a melhoria das condições de conforto térmico, a redução dos consumos energéticos com aquecimento, arrefecimento e as águas quentes sanitárias. Tais melhorias são alcançáveis com intervenções que se foquem na envolvente dos edifícios, com a aplicação de sistemas de alta eficiência para o aquecimento, arrefecimento, iluminação e águas quentes sanitárias e com a integração de fontes de energias renováveis. Assim é possível alcançar edifícios com necessidades nulas ou quase nulas de energia, tal como exigem as metas impostas a nível europeu.
Resumo:
A eficiência energética e a preocupação com a sustentabilidade têm vindo a ganhar preponderância na sociedade moderna. Este trabalho é uma contribuição para esta tendência onde se pretendeu avaliar e sugerir alterações ao sistema de climatização do edifício Biorama do Parque Biológico de Vila Nova de Gaia (PBG). Procedeu-se em primeiro lugar a uma caracterização física, química e geográfica dos 5 biomas constituintes do Biorama. Para isso, recorreu-se a documentos fornecidos pelo próprio PBG, visitas ao local e registo de medições de alguns parâmetros (temperatura, humidade relativa, qualidade do ar). Posteriormente foi realizado o balanço térmico dos edifícios, de acordo com a legislação em vigor, recorrendo a expressões e conceitos teóricos. Foram determinados valores dos ganhos térmicos de aquecimento de 15811, 10694, 7939, 9233, e 6621 kWh/ano para Floresta tropical, Mesozoico, Dunas, Savana e Deserto, respetivamente. Foram igualmente determinados valores dos ganhos térmicos no verão de 7093, 4798, 3560, 4144 e 2971 kWh na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de aquecimento foram 149, 125, 47, 60 e 51 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de arrefecimento foram iguais a 59, 57, 47, 35 e 36 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. Algumas soluções são avançadas, bem como alternativas comportamentais de modo a corrigir alguns problemas identificados. Uma proposta é a da instalação de painéis solares e acumuladores de calor, com os quais se estima um ganho médio conjunto de 500 W em cada bioma, e representam um investimento de 1050 euros e terão um retorno de 1 ano. Em relação à humidade é sugerido a utilização mais eficaz dos aspersores existentes e a utilização de esponjas, para fazer subir a humidade relativa para valores superiores a 80%. Em sentido inverso, no inverno, propõem-se a utilização de material higroscópico para fazer baixar a humidade relativa em cerca de 5%. Os custos com os suportes e o material higroscópico rondam os 250 €. Por fim, é sugerido a instalação de um aparelho de ar condicionado de 16 000 BTU no corredor de ligação, pois é a única forma de garantir condições de conforto térmico. Esta proposta de arrefecimento com ar condicionado e ainda o recurso a uma cortina de lâminas de plástico, que servem para efetuar uma separação mais eficiente entre ar frio e ar quente, têm um custo aproximado de 350 €. É ainda sugerida a utilização de lonas ou de uma planta trepadeira com um custo por planta de 5€, nas coberturas dos telhados virados a sul, sendo que a zona do corredor deverá ser totalmente coberta, a fim de evitar a exposição solar direta.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Ambiente pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
Schistosomiasis mansoni in the Serrano village, municipality of Cururupu, state of Maranhão, Brazil, is a widely spread disease. The PECE (Program for the Control of Schistosomiasis), undertaken since 1979 has reduced the prevalence of S. mansoni infection and the hepatosplenic form of the disease. Nevertheless piped water is available in 84% of the households, prevalence remains above 20%. In order to identify other risk factors responsible for the persistence of high prevalence levels, a cross-sectional survey was carried out in a systematic sample of 294 people of varying ages. Socioeconomic, environmental and demographic variables, and water contact patterns were investigated. Fecal samples were collected and analyzed by the Kato-Katz technique. Prevalence of S. mansoni infection was 24.1%, higher among males (35.5%) and between 10-19 years of age (36.6%). The risk factors identified in the univariable analysis were water contacts for vegetable extraction (Risk Ratio - RR = 2.92), crossing streams (RR = 2.55), bathing (RR = 2.35), fishing (RR = 2.19), hunting (RR = 2.17), cattle breeding (RR = 2.04), manioc culture (RR = 1.90) and leisure (RR = 1.56). After controlling for confounding variables by proportional hazards model the risks remained higher for males, vegetable extraction, bathing in rivers and water contact in rivers or in periodically inundated parts of riverine woodland (swamplands)
Resumo:
Nesta dissertação pretendeu-se estudar a viabilidade do uso de eletrodiálise com membranas bipolares (BM) na recuperação de ácido clorídrico e de hidróxido de sódio a partir de um efluente industrial que contém 1.4 mol/L de cloreto de sódio. Estas membranas mostraram ser uma ferramenta eficiente para a produção de ácidos e bases a partir do respetivo sal. Foi feita uma seleção de diferentes membranas bipolares (Neosepta, Fumatech e PCA) e aniónicas (PC-SA e PC-ACID 60) na tentativa de encontrar a combinação mais adequada para o tratamento do efluente. Dependendo do critério, o melhor arranjo de membranas é o uso de PC-ACID 60 (membrana aniónica), PC-SK (membrana catiónica) e membranas bipolares do tipo Neosepta para maior pureza dos produtos; membranas bipolares Fumatech para maior eficiência de dessalinização e membranas bipolares PCA para um maior grau de dessalinização. Tecnologicamente foi possível obter uma dessalinização de 99.8% em quatro horas de funcionamento em modo batch com recirculação de todas as correntes. Independentemente da combinação usada é recomendável que o processo seja parado quando a densidade de corrente deixa de ser máxima, 781 A/m2. Assim é possível evitar o aumento de impurezas nos produtos, contra difusão, descida instantânea do pH e uma dessalinização pouco eficiente. A nível piloto o principal fornecedor de membranas e unidade de tratamento “stack” é a marca alemã PCA. Sendo assim realizaram-se ensaios de repetibilidade, contra difusão, avaliação económica e upscaling utilizando as membranas bipolares PCA. A nível económico estudou-se o uso de dois tipos de unidades de tratamento; EDQ 380 e EDQ 1600, para diferentes níveis de dessalinização (50, 75 e 80%). Tendo em conta a otimização económica, é recomendável uma dessalinização máxima de 80%, uma vez que a eficiência de processo a este ponto é de 40%. A aplicação do método com a unidade EDQ 1600 para uma dessalinização de 50% é a mais vantajosa economicamente, com custos de 16 €/m3 de efluente tratado ou 0,78 €/kg Cl- removido. O número de unidades necessárias é 4 posicionados em série.
Resumo:
The use of questionnaires has been recommended for identifying, at a lower cost, individuals at risk for schistosomiasis. In this study, validity of information obtained by questionnaire in the screening for Schistosoma mansoni infection was assessed in four communities in the State of Minas Gerais, Brazil. Explanatory variables were water contact activities, sociodemographic characteristics and previous treatment for schistosomiasis. From 677, 1474, 766 and 3290 individuals eligible for stool examination in the communities, 89 to 97% participated in the study. The estimated probability of individuals to be infected, if they have all characteristics identified as independently associated with S.mansoni infection, varied from 15% in Canabrava, to 42% in Belo Horizonte, 48% in Comercinho and 80% in São José do Acácio. Our results do not support the hypothesis that a same questionnaire on risk factors could be used in screening for S.mansoni infection in different communities.